AcuityBrands WL1 Watch Light NEMA Head Security Instruction Manual
- June 9, 2024
- AcuityBrands
Table of Contents
WL1 Watch Light NEMA Head Security
- To reduce the risk of death, personal injury or property damage from fire, electric shock, falling parts, cuts/abrasions, and other hazards please read all warnings and instructions included with and on the fixture box and all fixture labels.
- Before installing, servicing, or performing routine maintenance upon this equipment, follow these general precautions.
- Installation and service of luminaires should be performed by a qualified licensed electrician.
- Maintenance of the luminaires should be performed by person(s) familiar with the luminaires’ construction and operation and any hazards involved. Regular fixture maintenance programs are recommended.
- It will occasionally be necessary to clean the outside of the refractor/lens. Frequency of cleaning will depend on ambient dirt level and minimum light output which is acceptable to user. Refractor/lens should be washed in a solution of warm water and any mild, non-abrasive household detergent, rinsed with clean water and wiped dry. Should optical assembly become dirty on the inside, wipe refractor/lens and clean in above manner, replacing damaged gaskets as necessary.
- DO NOT INSTALL DAMAGED PRODUCT! This luminaire has been properly packed so that no parts should have been damaged during transit. Inspect to confirm. Any part damaged or broken during or after assembly should be replaced.
- Recycle: For information on how to recycle LED electronic products, please visit www.epa.gov.
- These instructions do not purport to cover all details or variations in equipment nor to provide every possible contingency to meet in connection with installation, operation, or maintenance. Should further information be desired or should particular problems arise which are not covered sufficiently for the purchaser’s or owner’s purposes, this matter should be referred to Acuity Brands Lighting, Inc.
WARNING
RISK OF ELECTRIC SHOCK
√ Disconnect or turn off power before installation or servicing.
√ Verify that supply voltage is correct by comparing it with the luminaire
label information.
√ Make all electrical and grounded connections in accordance with the National
Electrical Code (NEC) and any applicable local code requirements.
√ All wiring connections should be capped with UL approved recognized wire
connectors.
CAUTION
RISK OF INJURY
√ Wear gloves and safety glasses at all times when removing luminaire from
carton, installing, servicing or performing maintenance.
√ Avoid direct eye exposure to the light source while it is on.
WARNING
RISK OF BURN
√ Allow lamp/fixture to cool before handling.
Do not touch enclosure or light source.
√ Do not exceed maximum wattage marked on luminaire label.
√ Follow all manufacturer’s warnings, recommendations and restrictions for:
driver type, burning position, mounting locations/methods, replacement and
recycling.
CAUTION
RISK OF FIRE
√ Keep combustible and other materials that can burn, away from lamp/lens.
√ Do not operate in close proximity to persons, combustible materials or
substances affected by heat or drying.
LED IMPORTANT SAFETY INSTRUCTIONS
CAUTION: RISK OF PRODUCT DAMAGE
√ Never connect components under load.
√ Do not mount or support these fixtures in a manner that can cut the outer
jacket or damage wire insulation.
√ Unless individual product specifications deem otherwise: Never connect an
LED product directly to a dimmer packs, occupancy sensors, timing devices, or
other related control devices. LED fixtures must be powered directly off a
switched circuit.
√ Unless individual product specifications deem otherwise: Do not restrict
fixture ventilation. Allow for some volume of airspace around fixture. Avoid
covering LED fixtures with insulation, foam, or other material that will
prevent convection or conduction cooling.
√ Unless individual product specifications deem otherwise: Do not exceed
fixtures maximum ambient temperature.
√ Only use fixture in its intended location.
√ LED products are Polarity Sensitive. Ensure proper Polarity before
installation.
√ Electrostatic Discharge (ESD): ESD can damage LED fixtures. Personal
grounding equipment must be worn during all installation or servicing of the
unit.
√ Do not touch individual electrical components as this can cause ESD, shorten
lamp life, or alter performance.
√ Some components inside the fixture may not be serviceable. In the unlikely
event your unit may require service, stop using the unit immediately and
contact an ABL representative for assistance.
√ Always read the fixtures complete installation instructions prior to
installation for any additional fixture specific warnings.
Please see product specific installation instructions for additional warnings
or any applicable FCC or other regulatory statements.
Failure to follow any of these instructions could void product warranties. For
a complete listing of product Terms and Conditions, please visit
www.acuitybrands.com.
Our Brands| Indoor/Outdoor
Lithonia Lighting
Carandini
Holophane
RELOC| Indoor Lighting
Gotham
Mark Architectural Lighting
Peerless
Renaissance Lighting
Winona Lighting| Outdoor Lighting
American Electric Lighting
Antique Street Lamps
Hydrel
Tersen
Controls| DARK TO LIGHT
Lighting Control & Design
ROAM
Sensor Switch
Synergy
---|---|---|---|---
Please see product specific installation instructions for additional warnings
or any applicable FCC or other regulatory statements.
Failure to follow any of these instructions could void product warranties. For
a complete listing of product Terms and Conditions, please visit
www.acuitybrands.com.
WATCHLIGHT SERIES
Drop Refractor and
Refractor with Trespass Shield
Installation and Maintenance Manual
INTRODUCTION
Product Description
The Drop Refractor is intended to increase light thrownupwards by the
luminaire. The light trespass Shield is intended to prevent any light from
being emitted in a particular direction based on where the shield is
installed. Each refractor kit consists of a refractor and #8 Hex head thread
rolling screws (x3). Each Trespass Shield kit consists of one shield.
INSTALLATION
Tools and Materials Required
Description | Use |
---|---|
¼” Socket or Nut Driver | Screws |
Drop Refractor:
Pre-install provided (3) #8 Hex head screws in holes surrounding luminaire
optical area. Do not fully tighten. Before installing the refractor, open the
door of luminaire and break off the tab that covers the wires leading into the
optics chamber. The tab has a score line and can be easily broken off by hand
along this line. Align keyhole slots in refractor base to screws. Rotate
refractor slightly to engage keyholes slots onto screw heads. Tighten screws
until snug.
Drop Refractor with Light Trespass Shield: These instructions are meant for
installation of a Light Trespass Shield for use in combination with a drop
refractor only
If a Drop Refractor is already installed, loosen #8 hex head screws and rotate
refractor to engage keyhole slots and remove from luminaire.
Place the Light Trespass Shield snug against the outside of the refractor.
Bend the legs at the bottom and the top of the Trespass Shield so that they
hook around the refractor. See previous section for Drop Refractor
Installation.
Note: The shield installation can be done without entirely removing the
refractor by only loosening the refractor screws and pre-bending the bottom
refractor tabs to slide them under the shield. However, complete removal of
the refractor is the generally the easiest method of installation.
INTRODUCTION
Product Description The Light Trespass Shield is intended to limit the light
directed to the sides and above/below the luminaire. There is a standard kit
consisting of a shield and #8 Hex head thread rolling screws (x2) and a street
side kit consisting of a shield and #8 Hex head thread rolling screws (x3)
INSTALLATION
Tools and Materials Required
Description
‘¼” Socket or Nut Driver
Use
Screws
Light Trespass Shield:
If luminaire has pre-installed Zero Uplight Shield, loosen the #8 Hex head
screws (3). The Trespass Shield will share two #8 Hex head screws with the
Uplight Shield.
For each Trespass Shield kit there are three possible alignments (house side,
right, left) for installation of the trespass shield with mounting locations
surrounding the optical area. Align screw hole locations on the shield to
desired orientation. Install provided (2) #8 Hex head screws in holes
surrounding luminaire optical area. If zero-uplight shield is already
installed, loosen existing screws enough to slide street side shield into
place and tighten screws back into place.
Light Trespass Shield – Street Side:
The Street Side Trespass Shield kit is intended to be installed on the street
side of the fixture. Align screw hole locations on the shield to street side
orientation. Install provided (3) #8 Hex head screws in holes surrounding
luminaire optical area. If zero-uplight shield is already installed, loosen
existing screws enough to slide street side shield into place and tighten
screws back into place.
INTRODUCTION
Product Description The Zero Uplight Shield is intended to limit the light
directed above the luminaire. Each Zero-uplight Shield kit consists of a
shield and #8 Hex head thread rolling screws (x3).
INSTALLATION
Tools and Materials Required
Description
‘¼” Socket or Nut Driver
Use
Screws
Zero Uplight Shield:
Pre-install provided (3) #8 Hex head screws in holes surrounding luminaire
optical area. Do not fully tighten. Before installing the shield, open the
door of luminaire and break off the tab that covers the wires leading into the
optics chamber. The tab has a score line and can be easily broken off by hand
along this line. Align keyhole slots in Uplight Shield base to screws. Rotate
uplight shield slightly to engage keyholes slots onto screw heads. Tighten
screws until snug.
©2014 Acuity Lighting Group, Inc.
Acuity Brands Lighting, Inc. assumes no responsibility for claims arising out
of improper or careless installation or handling of its products.
ABL LED General Warnings, Form No. 503.203
© 2013 Acuity Brands Lighting, Inc. All rights reserved. 6/12/13
IN-352
IM426C
Documents / Resources
|
AcuityBrands WL1 Watch Light NEMA Head
Security
[pdf] Instruction Manual
WL1 Watch Light NEMA Head Security, WL1, Watch Light NEMA Head Security, NEMA
Head Security, Head Security
---|---
References
- Acuity Brands | Lighting, Controls, and Building Management Solutions
- U.S. Environmental Protection Agency | US EPA
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>