legrand EC770 Series Wp3 Weatherproof LED Battens
Specifications
- Supply Voltage: 230 – 240V a.c. 50Hz
- IP Rating: IP65
Product Usage Instructions
Installation
The WP3 Weatherproof LED Batten can be installed in three ways:
Using Installation Screws:
- Drill 2 holes at the back of the body in the provided locations.
- Install the body to the ceiling or wall using the screws provided.
- Use the supplied washer to ensure IP65 is maintained.
Using Installation Brackets:
- Attach 2 stainless steel installation brackets to the ceiling or wall using the provided screws.
- Clip the body onto the brackets.
Using Suspension Brackets:
- Attach the suspension bracket to the stainless steel brackets for suspension with wires.
- Clip the body onto the installation brackets.
Wiring
Use 1.0mm² or 1.50 mm² flexible cord for wiring. Connect the power cable to
the terminal block (A – Active, N – Neutral, E – Earth).
Colour Temperature Setting
The 3-position switch on the gear tray can adjust the colour temperature to
WARM WHITE, COOL WHITE, or NATURAL WHITE. Default setting is COOL WHITE.
Lumen Select Setting
The brightness of the luminaire can be adjusted by setting the output current
of the LED driver. The settings and corresponding lumen output levels are
provided in the manual for different models.
FAQ
Q: What is the default color temperature setting?
A: The default color temperature setting is COOL WHITE.
Q: How can I adjust the brightness of the luminaire?
A: The brightness can be adjusted by setting the output current of the
LED driver using the switches provided on the driver. Refer to the manual for
specific settings based on your model.
Specifications
All Models
- Supply Voltage 230 – 240V a.c. 50Hz
- IP Rating IP65
Installation
The WP3 Weatherproof LED Batten can be installed in 3 ways with the help of installation brackets, suspension brackets and installation screws provided.
Using installation screws:
- Drill 2 holes at the back of the body in the locations provided. Install the body to the ceiling or wall using the screws provided. Use the supplied washer to ensure that IP65 is maintained. The installation centres are shown in the table below.
Using installation brackets:
- Attach 2 stainless steel installation brackets to the ceiling or wall using the screws provided. Clip the body on to the brackets. The range of installation centres are shown in the table below.
Using suspension brackets:
- The batten can also be suspended with wires by attaching the suspension bracket to the stainless steel brackets as shown. Once attached, clip the body to the installation brackets.
Batten length (mm) | Installation Centres (mm) |
---|---|
Using Screws | Using installation brackets |
600 | 500 |
1200 | 1060 |
1500 | 1350 |
Installation positions to maintain IP rating
Wiring
- Disconnect mains supply before installing, servicing or maintaining the luminaire.
- Unlock the diffuser clips and remove the diffuser. Note that 2 of the clips are designed to stay attached to the diffuser so that it can hang from the body during installation.
- Remove the gear tray by twisting the quarter-turn fasteners. Clip the lanyards to the gear tray.
- Fit the power cable through the supplied IP65 gland. Cable glands are compatible with circular cable 8-10 mm in diameter. e.g. 3 – core heavy duty (H07VV-F) 1.0mm2 or 1.50 mm2 flexible cord.
- Connect the power cable to the terminal block (A -Active, N- Neutral, E- Earth).
- For DALI models, connect the DALI cable to the two terminals marked “DA”. If the DALI cable is separate from the power cable, an additional cable gland will be required.
- For emergency models, an additional Switched Active terminal is provided to allow the luminaire to be switched on and off in mains mode. For non-maintained operation, do not connect the Switched Active terminal.
- Secure the gear tray to the body by twisting the quarter-turn fasteners.
- IMPORTANT: For wireless emergency versions that are wall-mounted, bend the part of the gear tray where the antenna is mounted so that it is as close as possible to a vertical position. Failure to do this may result in poor communication.
- Close the diffuser and ensure all diffuser clips are locked in place.
Colour temperature setting
The 3-position switch located on the gear tray can adjust the colour
temperature to WARM WHITE, COOL WHITE OR NATURAL WHITE. The default setting is
COOL WHITE.
Lumen select setting (not applicable for Auto Occupancy or DALI models)
The brightness of the luminaire in mains mode can be adjusted by setting the
output current of the LED driver to one of 4 possible levels. This is done by
setting the 2 switches on the LED driver as shown:
Each setting corresponds to the following lumen output levels:
600mm Models
Switch position|
LED driver output current (mA)
| Lumen output (lm)
---|---|---
1| 2| Warm white| Cool white| Natural white
OFF| OFF| 400 (factory default)| 1900| 1940| 1960
ON| OFF| 500| 2330| 2400| 2410
OFF| ON| 600| 2750| 2850| 2850
ON| ON| 700| 3140| 3310| 3260
1200mm Models
Switch position|
LED driver output current (mA)
| Lumen output (lm)
---|---|---
1| 2| Warm white| Cool white| Natural white
OFF| OFF| 700| 3480| 3560| 3600
ON| OFF| 850 (factory default)| 4220| 4370| 4390
OFF| ON| 900| 4430| 4580| 4600
ON| ON| 1050| 5140| 5360| 5350
1500mm Models
Switch position|
LED driver output current (mA)
| Lumen output (lm)
---|---|---
1| 2| Warm white| Cool white| Natural white
OFF| OFF| 700| 4450| 4540| 4580
ON| OFF| 850 (factory default)| 5410| 5590| 5610
OFF| ON| 900| 5690| 5910| 5920
ON| ON| 1050| 6610| 6890| 6870
Note:
- The lumen output of Auto Occupancy models is fixed at the factory default setting and cannot be changed.
- The lumen output of DALI models is factory set at the highest setting and can be changed by DALI commands.
For movement sensor models only
There are two types of movement sensor models:
ON/OFF Model| These units turn ON when movement is detected and turn OFF after
a certain time period has elapsed with no movement.
---|---
Auto Occupancy Model| These units turn ON when movement is detected and dim
down to 10% brightness after a certain time period has elapsed with no
movement.
For all of these models, the user can change the following settings by turning the 3 selector switches with a small flat-head screwdriver.
Detection Range Setting
When installed at a height of 2.5m, turning the selector switch to the minimum setting will give a circular detection range of 1m radius. Turning the selector switch to the maximum setting will give a circular detection range of 8m radius.
Default factory setting = maximum range
Time Setting
The light can be set to stay ON for any period of time between approximately 10 seconds (selector switch turned fully anticlockwise) and 30 minutes (selector switch turned fully clockwise). When adjusting the time setting selector switch with the power ON, the LED indicator next to the selector switch will flash as follows:
Number of flashes | Time setting |
---|---|
1 | 10 Seconds |
2 | 1 minute |
3 | 2 minutes |
4 | 5 minutes |
5 | 8 minutes |
6 | 10 minutes |
--- | --- |
7 | 15 minutes |
8 | 20 minutes |
9 | 25 minutes |
10 | 30 minutes |
Any movement detected during the ‘ON’ time will restart the timer. When the timer expires the light will turn OFF, or dim to 10% brightness (depending on the model) and there is a delay of approximately 4 seconds before the sensor will start detecting movement again.
Default factory setting:
- 30 minutes (ON/OFF models)
- 5 minutes (Auto occupancy models)
Light level setting
This setting determines the ambient light level below which the movement
sensor will operate. The minimum setting is approximately 10 lux (selector
switch turned fully anticlockwise) and the maximum setting is approximately
2000 lux (selector switch turned fully clockwise). To enable the sensor to
operate during the day, select the maximum setting. When the minimum setting
is selected, the sensor will operate at night only, and the light will remain
OFF during the day.
Default factory setting = maximum light level (day operation)
Test switch (Emergency models only)
Test switch is located on the gear tray behind the diffuser. After installation, press test switch for local test of Emergency Mode operation.
Replacement Batteries (Emergency models only)
- 659210 (2-foot models)
- 659204 (4-foot and 5-foot models)
Status Indication
Battery Charging LED (all models except DALI)
LED ON | Battery is in good condition and is being charged when necessary. |
---|---|
LED OFF | Loss of mains power, OR Battery disconnection, OR Unit is under test. |
LED single flash every 2 sec | Battery is faulty and should be replaced. |
Communications LED – Galaxy (Blue)
LED ON | New SPU to be commissioned |
---|---|
LED flashing slowly (1 sec ON, 1 sec OFF) | SPU has been commisioned and ready |
to join the network or SPU has become offline.
LED OFF| SPU is online and ready
The LED also flashes momentarily whenever a communications message is
received.
Communications LED – Axiom (Yellow or Green)
LED continuous rapid flashing| Self-testing has found a fault within the unit
(the battery charging LED also flashes rapidly)
---|---
LED flashing slowly (1 sec ON, 1 sec OFF)| Unit is yet to be commissioned.
LED OFF| Communications are good.
The LED also flashes momentarily whenever a communications message is
received.
DALI Range – Red and Green LEDs
Green ON| Mains mode – system OK| Red ON| Load failure (open circuit or short
circuit)
---|---|---|---
Rapidly flashing Green| Function test underway| Rapidly flashing Red|
Incorrect charging current
Slow flashing Green (1 sec ON, 1 sec OFF)| Duration test underway| Slow
flashing Red
(1 sec ON, 1 sec OFF)
| Battery is defective, OR battery voltage is incorrect, OR battery failed the
duration test or function test.
Double pulsing Green| Switching into inhibit mode via controller| Green and
Red OFF| Battery operation (emergency mode)
During address identification mode, the Red and Green LEDs will pulse to
indicate the address of the unit in binary format.
iSmart™ Temperature Sensing
- Charging Lithium-Ion batteries at extremely high or low temperatures can result in a hazardous situation. Therefore, all Legrand Lithium-Ion emergency lighting products contain iSmart™ Temperature Sensing which temporarily turns off the battery charger when the ambient temperature is outside the battery specifications.
- When the battery charger is turned off due to iSmart Temperature Sensing, the battery charging LED will remain on to indicate that the product is still able to operate correctly.
- Charging will automatically resume when the ambient temperature returns to a level within the battery specifications.
Installation
- This product must be installed by a licensed electrician, and must be installed and used as per these instructions. After installation this product must be commissioned, tested and maintained as required by the appropriate government and/or statutory regulations.
- This product must be securely attached to a suitable structural member of the installation.In all Galaxy fittings, the antenna must be oriented in the vertical position wherever possible to ensure good RF communication.
- With the battery connected and the product connected to the unswitched mains supply, check that the charge LED is illuminated according to the tables above. If not illuminated, check that the supply is on and the battery leads are correctly connected.
- The product must be powered up for a minimum of 16 hours before a full discharge test is performed. However, checking of the emergency lamp function may be performed immediately by momentarily pressing the test switch on the product.
- Where a test switch is not visible, the product has a magnetic test switch that may be activated by holding a magnet near the label marked “Magnetic Test Switch”.
- Interrupting the mains supply will discharge the battery. If the supply remains interrupted for a long period, permanent damage to the battery may result due to excessive discharge. For Lithium-ion batteries, leaving the batteries discharged for more than 12 months will void the battery warranty. Do not subject the battery to a high number of charge/discharge cycles as can occur on a temporary supply (e.g. construction site).
Important Notes
- This product must be installed and used as per these instructions.
- This product must be installed by a licensed electrician.
- An IP rating of IP65 is completely protected against dust and generally considered suitable for fully exposed external installations, but not for high pressure hoses.
- The IP rating of this product is only valid when all applicable seals, glands and their appropriate cables are installed correctly.
- This product must be securely attached to a suitable structural member of the installation.
- This product is not suitable for marine environments such as areas subject to salt spray and/or mist.
- This product should only be cleaned with a damp cloth. Cleaning agents and solvents should not be used.
- This product is not suitable for installation in hazardous and/or corrosive areas.
- This product has been designed to operate in ambient temperatures 0°C to 40°C.
- Any antenna in this product must be orientated in the vertical position to ensure good RF communication.
- The rechargeable battery in this product MUST be replaced when the unit no longer meets rated operating life. If this product is to be stored for more than 3 months then the battery must be disconnected prior to storage. At the end of its life the battery should be recycled.
- Severe electromagnetic interference may cause malfunction of this product. Emergency lighting should be installed on dedicated circuits to ensure that interference from other luminaires does not affect its operation. Performance may also be affected if installed near RF transmitters such as mobile phone services, or installed in or around substantially metal enclosures or structures.
- The material in this product may vary in colour from batch to batch. Colour matching from one batch to another cannot be guaranteed. Extended exposure to UV rays (such as exposure to direct sunlight) may cause discolouration of this product.
- The light source of the emergency fitting is not replaceable; when the light source reaches its end of life the fitting must be replaced.
- For full technical or photometric data please contact Legrand.
- This product has no user serviceable parts and no attempt should be made to repair this product. For repair or replacement please contact Legrand or our service agent.
- This product utilizes intellectual property in the form of registered designs, trademarks and/or patents. Such intellectual property remains the property of Legrand in all cases.
- Legrand reserves the right to modify the specifications of this product at any time.
Warranty
Legrand guarantees this product for a period of 5 years (Lithium-ion battery models) or 1 year (Other battery models) from date of despatch, solely against failure arising from faulty materials or workmanship, and provided that the unit has been stored, shipped, installed, used and maintained in accordance with the manufacturer’s instructions and relevant standards. Misuse, negligence or modification of the unit voids all warranties. Consult Legrand Conditions of Sale for details on warranty liability. If this product is faulty, return the unit freight pre-paid to your point of purchase, or contact Legrand.
Customer Service
For all Customer Service and Technical Support enquires please call Monday to
Friday during business hours.
Legrand New Zealand 0800 476 009
www.legrand.co.nz ABN: 31 000 102 661
Legrand Australia 1300 369 777
www.legrand.com.au
Legrand (S) Pte Ltd Phone: +(65) 6416 1550 www.legrand.com.sg
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>