inVENTer iV-Office Ventilation Device Installation Guide
- August 14, 2024
- inVENTer
Table of Contents
- inVENTer iV-Office Ventilation Device
- Specifications
- Installation Instructions
- User and Safety Instructions
- Technical Data
- Scope of Supply
- Troubleshooting
- Warranty and Guarantee
- Service
- FAQs
- Intended use
- SYSTEM OVERVIEW: IV-OFFICE VENTILATION DEVICE
- Components
- PREPARING FOR INSTALLATION
- WARRANTY AND GUARANTEE
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
inVENTer iV-Office Ventilation Device
Specifications
- Product Name: iV-Office Ventilation Device with Heat Recovery
- Manufacturer: Inventer
- Website: www.inventer.eu
Installation Instructions
Follow the detailed installation instructions provided in the manual to properly set up the iV-Office ventilation device with heat recovery.
User and Safety Instructions
- User Information: Refer to section 1.1 of the manual for user information.
- Safety Instructions: Section 1.2 of the manual contains important safety guidelines to follow during usage.
Technical Data
- General Specifications: Detailed technical specifications can be found in section 5 of the manual.
- iV-Office Energy Label: Check section 5.2 for energy label information according to ErP Directive, Regulation 1254/2014.
- Specifications According to ErP Directive: Refer to section 5.3 for specific details as per Regulation 1254/2014.
Scope of Supply
Section 6 of the manual outlines the components included in the package of the iV-Office ventilation device.
Troubleshooting
For any issues or problems encountered during usage, consult section 7 of the manual for troubleshooting steps.
Warranty and Guarantee
Information regarding warranty and guarantee policies can be found in section 8 of the manual.
Service
Section 9 provides details on service options available for the iV-Office ventilation device.
FAQs
Q: Where can I find the latest version of the documentation?
A: The latest version of the documentation can be accessed at
www.inventer.eu/downloads.
Trademarks, copyrights and property rights
inVENTer®, Xenion®, inVENTron®, Inventin and Clust-Air® are registered
trademarks of inVENTer GmbH.
The copyright to this document remains with the manufacturer. Rights to all
content and images: © inVENTer GmbH 2022.
All trademarks used in this document are the property of their respective
manufacturers and are hereby acknowledged.
Disclaimer
This documentation represents an translation of the original German
installation instructions. After completion of the installation the
information regarding access to these installation instructions must be handed
over to the user (tenant, owner, property management, etc.). The content of
this documentation has been checked for compliance with the described
components. Nevertheless deviations may still occur, therefore no guarantee of
compliance can be provided.
This documentation describes the functionality of the standard scope. For
reasons of clarity, the documentation does not purport to cover all details on
all types of the product and cannot cover every conceivable scenario for
installation and assembly.
The illustrations in this document may differ slightly from the design of the
product that you have purchased. The same functionality is ensured despite any
design deviations.
This documentation is updated regularly. Necessary corrections and appropriate
supplements are always included in subsequent editions. You can also find the
latest version at www.inventer.eu/downloads.
1 User and safety instructions
Thank you for purchasing this high quality product from inVENTer!
This section provides an overview of the basic safety precautions for safe and
proper operation of your ventilation device.
1.1 User information
Safety and warning instructions
The safety and warning instructions in these installation instructions have a uniform structure and are marked with a symbol on the left side of the instruction. A signal word in front of the text also indicates the hazard level. If several hazard levels exist, the highest level safety instruction is always used.
The safety and warning instructions contain the following information:
SIGNAL WORD: Type and origin of the hazard. Possible consequences of the hazard! Measures to avoid the hazard.
The signal word indicates the severity of the potential hazard unless the preventive measures are taken:
DANGER means: Imminent danger of serious injury or death.
WARNING means: Possible danger of serious injury or death.
CAUTION means: Direct danger of minor/significant injury.
NOTICE means: Direct or possible risk of property damage due to an adverse event/state.
If you see these signs, ensure you observe the described measures to prevent possible hazards and/or damage.
Other symbols used in this documentation
In addition to the safety instructions, the following symbols are used:
A TIP symbol indicates practical and useful tips for handling your ventilation system.
Before each step, any additional tools and materials required for the activity are listed.
Red bar over a graphic: graphic shows the interior wall.
Blue bar over a graphic: graphic shows the exterior wall. Action required:
This prompts the user to perform a specific action. Check the results requires
you to check the results of the action you have performed. Action focus: To be
taken into account in the corresponding assembly step.
Office ventilation device | Installation instructions
USER AND SAFETY INSTRUCTIONS
1.2 Safety instructions
The installation instructions are part of your iV-Office ventilation device
and must be available at all times (see www.inventer.eu/downloads). When
handing the system to a third party, the information regarding access to the
installation instructions must be handed over also. Before performing any work
on the device/system, read the installation instructions carefully and observe
all notices that refer to the installation process in this section. Also note
the safety instructions that precede the described handling instructions. Non-
observance of safety instructions could result in injury and/or property
damage.
These installation instructions only cover the standard variant (referred to
as the “Standard variant” in the following text) of the iV-Office ventilation
device. Information on the variants can be found in the separate installation
instructions for the respective components.
Intended use
The ventilation device is designed to ventilate dwellings and similar
residential spaces and other areas where people spend time e.g. living rooms
and bedrooms, offices, basements and attics. It is controlled via an inVENTer
system control device (hereinafter referred to as the “controller”).
General information
· Always observe the relevant standards, regulations and guidelines when
installing the equipment / system. In particular also applicable building
regulations, fire safety regulations and accident prevention regulations of
the employers’ liability insurance association.
· Use the device/system exclusively for the applications that are described in
this documentation and only in conjunction with components that are
recommended, authorised and described by inVENTer GmbH in this documentation.
Changes or modifications to the equipment/system are not permitted.
· Your ventilation system is exclusively designed for use in ambient
temperatures between -20 and 50°C.
· Trouble-free and safe operation of the equipment / system depends on proper
transportation, proper storage and installation, as well as careful operation
and cleaning / care.
· The ventilation device is based on the free movement of air between
individual pairs of ventilation devices. Therefore, internal doors must not
have air-tight seals. Provide suitable air transfer measures to create a room
network (cross ventilation).
Installation and assembly
· CAUTION: The system may only be installed by qualified personnel. · Before
starting work, you should have a project plan showing the number of
ventilation devices,
the location of the ventilation devices, the ventilation principle (cross
ventilation, single room ventilation, extract ventilation) and the associated
controllers. The exact positioning of the individual devices and control
devices must be checked at the installation site and, if necessary, adapted to
the local conditions with the involvement of the responsible planner or user.
For optimum functionality, it is recommended to install the device at an
appropriate place in the upper wall area. · WARNING: For joint operation with
fireplaces, safety measures must be taken to prevent a negative pressure from
developing in the building. The responsible chimney sweep and/or building
planner decides which measures need to be carried out.
iV-Office ventilation device | Installation instructions
5
USER AND SAFETY INSTRUCTIONS
· NOTICE: The ventilation device is not suitable for drying out buildings. Do
not put it into operation until the construction work has been completed.
· NOTICE: Contamination of components, e.g. by plaster residue, will damage
the components! Seal the ventilation device/air outlets of the ventilation
device so they are dust-tight throughout the construction work. Do not remove
the thread locks until final assembly.
· NOTICE: Do not install the device near indoor air thermostats or in the
immediate vicinity of/ above sensitive pictures or furniture.
· NOTICE: Observe the specified minimum clearances on both sides of the wall
and frontally to prevent unintentional mixing of different air flows and to
ensure access to the device and its components. A minimum distance of 1.2 m
must be maintained between adjacent air openings. (, page 14 f.).
· NOTICE: The wall sleeve must be integrated into the building envelope
(airtightness level) in accordance with the current state of the art, taking
into account construction-related and physical specifications (“RAL
installation”). Material for this is must be provided on site.
· NOTICE: When bringing the wall construction up to the wall sleeve, observe
the necessary blocking levels to avoid interrupting the composite thermal
insulation system. Consult your planner before installation if you are at all
uncertain!
· NOTICE: Install the wall sleeve with a slope of 1 – 2° to the exterior wall
to ensure the drainage of any condensate that may form.
· NOTICE: Do not install the ventilation device in places where direct contact
with water spray is possible. Observe the specifications of VDE 0100 when
choosing the installation location.
· NOTICE: Store components standing outside the wall sleeve and do not throw
them to avoid damage and breakage of the components, especially the thermal
accumulator.
· NOTICE: In order to avoid algae growth around the external terminations, the
instructions for installation must be followed exactly (apply all sealing
tapes!). We recommend a biocidal pretreatment/water-repellent pre-treatment of
the façade surface around the external terminations. Consult your planner
about this!
· NOTICE: When installing components in (exterior) walls with insulation, use
insulation wallplugs to ensure that the components are securely fastened.
Insulation wallplugs are not included in the scope of supply, they are
available as an option!
· NOTICE: Only use permanently elastic sealing compound suitable for outdoor
use to seal the joints at all external edges!
· NOTICE: The device has scratch-sensitive plastic surfaces. Do not touch the
components with oily and/or dirty hands. Avoid contact with sharp or pointed
objects, e.g. rings.
Cabling / connection of the reversible fan
· CAUTION: The system’s electrical connections may only be carried out by
qualified electricians.
· NOTICE: The reversible fan operates with protective extra-low voltage. It
must not be connected directly to the 230 V power grid.
· NOTICE: Laying cables whose sheathing is not resistant to plastering under
plaster leads to short circuits and cable fire! Lay cables without a plaster-
resistant cable sheath in the conduit.
· NOTICE: The use of too small a cable cross-section leads to too great a
voltage drop and/ or contact is not guaranteed! For the fan BUS, use a cable
cross-section of at least 0.75 mm² (stranded wire). Use wire ferrules with
collars to connect the strands.
· When using several ventilation devices controlled by several controllers,
you must ensure that the ventilation devices are synchronised with each other
(see installation instructions for controllers). You should connect all
controllers via a mains fuse in the house distribution board.
If your device has a fault, contact your nearest distributor or our technical
service. Any kind of use other than the intended use will exclude all
liability claims.
6
iV-Office ventilation device | Installation instructions
USER AND SAFETY INSTRUCTIONS
Improper use
Any use that is not mentioned in the intended use section, is considered to be
improper.
Especially do not install / operate the device in areas which the following
may occur:
· Environment containing strong oils or lubricants. · Flammable, aggressive
and corrosive gases, liquids or vapours. · Extreme dust exposure. · Ambient
temperatures outside the range of -20 to 50 °C.
The ventilation device is not to be used as an opening to the outside and/or
for the purpose of smoke removal/smoke extraction in basements without
windows. Prevent obstacles that hinder access to, or removal of, components of
the ventilation device.
Qualified personnel
The equipment/system may only be set up, operated and cleaned in conjunction
with this documentation and the documentation for the controllers.
Installation, electrical connection and commissioning of the equipment/system
may only be performed by qualified personnel. Qualified personnel within the
meaning of the safety notices in this documentation are persons who are
authorised to install, put it into operation and identify equipment, systems
and circuits in accordance with established safety procedures.
Conformity
The ventilation device complies with the technical safety requirements and
standards of electrical appliances for domestic use. It conforms to current
European Union and United Kingdom directives. The full text of the EU
declaration of conformity is available at the following Internet address:
https://www.inventer.eu/downloads/ .
iV-Office ventilation device | Installation instructions
7
SYSTEM OVERVIEW: IV-OFFICE VENTILATION DEVICE
2 System overview: iV-Office ventilation device
The iV-Office is a decentralised ventilation system with heat recovery and is
designed for increased air flow requirements (performance-plus device). The
iV-Office is suitable for installation in new buildings as well as for
retrofitting in older buildings and is particularly suitable for use in large
living spaces and similar commercial premises (e. g. offices, doctors’
surgeries, lounges, etc.). Installation is generally carried out in the
exterior wall.
The ventilation device consists of a wall sleeve in which the thermal
accumulator insert is mounted. A lockable inner cover conceals the iV-Office
discreetly from the interior. The filter integrated into the inner cover
ensures that no pollen or dust from outside enters the interior. Outside, a
driving rain-proof cover conceals the components of the ventilation device.
The sound insulation lining made of Inventin, a material specially developed
to reduce noise, is inserted into the wall sleeve. The insulated wall sleeve
incorporates the ceramic thermal accumulator and inVENTron, two guiding vane
elements and the Xenion EFP reversible fan. The guiding vanes on both sides of
the fan serve to straighten the air flow and ensure more efficient flow
through the thermal accumulator. The sound-absorbing Inventin lining and the
unique geometry of the Xenion EFP reversible fan effectively reduce the
passage of sound.
The standard length of the wall sleeve is 495 mm. For thicker walls, a wall
sleeve and insert with a length of 745 mm can be ordered as an alternative.
Both versions can be shortened on site.
The ventilation device is controlled via one of the following inVENTer system
controllers1): · sMove · MZ-Home
Components
· Inner cover incl. ISO Coarse 60 % filter · Thermal accumulator insert
(thermal
accumulator, inVENTron and sound insulation lining made of Inventin)
· Wall sleeve · External termination2) · Pollen and activated carbon filter
(optional) · Sound and wind protection accessories
(optional)
Models
The ventilation devices of the iV-Office product range differ in their
external terminations. Additional inner covers are also available. This
documentation only contains information on the standard version of the
ventilation device. For information on the variants of the exterior and
internal terminations, please refer to the separate installation instructions
for the respective component:
· Standard variant: iV-Office ventilation device with Flex Office driving rain-proof weather protection hood (white/grey/anthracite/custom colour).
- The installation and operating instructions for the controller are not part of this documentation. 2) All external terminations are available in stainless steel or optionally in aluminium [increased salt resistance].
8
iV-Office ventilation device | Installation instructions
SYSTEM OVERVIEW: IV-OFFICE VENTILATION DEVICE
2.1 Construction B
A C
4
D
5
6
18
8
7
13
9
10
11
3
Standard variant
1 2
12
17
14 15
Flex Office
16
Figure 1: Overview of the iV-Office ventilation device
Components
A External termination:
Flex Office weather protection hood
1 Weather protection hood base plate 2 Flex Office ring insert (pre-installed)
3 Weather protection hood cover
B Wall sleeve
4 R-D250 wall sleeve 5 Recess for controller connecting
cable
C Thermal accumulator insert
(Thermal accumulator, inVENTron, sound insulation lining made of Inventin)
6 Sound insulation lining (Inventin) 7 Thermal accumulator 8 Thermal
accumulator handle 9 R-D200 guiding vane (wide) 10 Xenion EFP reversible fan
11 Slim guiding vane (narrow) 12 BUS plug connection 13 Guiding vane knob
D Flair XL inner cover
14 Flair XL adapter 15 Inner cover base plate 16 ISO Coarse 60 % dust filter
17 Inner cover panel 18 Spacer (4 x)
iV-Office ventilation device | Installation instructions
9
SYSTEM OVERVIEW: IV-OFFICE VENTILATION DEVICE
2.2 Function Decentralised ventilation
Decentralised ventilation systems combine extract and supply air and are based
on free air movement between individual pairs of ventilation devices (cross-
ventilation). The cross-ventilation principle allows the air to circulate
through the entire residential device and also sufficiently ventilate interior
living spaces. Each ventilation device is mounted in its own air duct so as
not to obstruct other ventilation processes.
70 s
The decentralised iV ventilation systems with heat recovery consist of
ventilation devices arranged in pairs with simple air flow. They operate
according to the principle of heat recovery by changing the direction of the
fan. The integrated thermal accumulator is charged with the thermal energy of
the room air as it flows externally (extract air). After 70 seconds, the
reversing fan changes the direction of rotation each time. After the direction
of rotation has changed, the heat accumulator releases the stored heat energy
to the incoming fresh air (supply air).
For this principle to work correctly and to ensure pressure stability in the
room, the supply air volume must always correspond to the extract air volume,
i.e. at least two ventilation devices are required. These are operated in
pairs in push-pull mode: another ventilation device is assigned to the
ventilation device that delivers supply air and at the same time removes used
extract air from the interior to the outside.
You operate the iV ventilation systems intuitively with the matching inVENTer
controllers. Different operating modes or the air volume flows can be set
individually.
The most important components of the iV system are the ceramic thermal
accumulator, the reversing fan, air guiding vanes for straightening the air
volume flow, filters for different hygienic requirements, a closable inner
cover and an outer cover. A control device (controller) completes the system.
10
iV-Office ventilation device | Installation instructions
SYSTEM OVERVIEW: IV-OFFICE VENTILATION DEVICE
Ventilation device iV-Office with heat recovery
The iV-Office ventilation system is used to provide ventilation for living
spaces and living space-like commercial premises. The combination of
inVENTron, thermal accumulator and sound insulation lining ensures maximum
heat recovery with minimum sound emissions and maximum air flow.
It is a ventilation device with simple airflow and works according to the
principle of heat recovery by changing the direction of the fan.
The iV-Office features especially quiet operation. The patented sound
insulation concept is based on the combination of the sound insulation lining
made of Inventin with the Xenion EFP reversible fan. The sound insulation
lining effectively absorbs sound waves from outside and from the device itself
(sound transmission and inherent sound). The arrangement and design of the fan
blades additionally reduces the sound transmission from outside.
Thanks to a high pressure build-up and the active speed control of the motor
(integrated wind pressure stabiliser) in the Xenion EFP reversible fan, the
air flow in the system is kept almost constant even in the event of weather-
related pressure fluctuations. Thus, the sensitivity of the air flow to
pressure fluctuations corresponds to class S2 according to EN 13141-8 (max. 20
% air flow deviation at ± 20 Pa). In order to ensure the full functioning of
the ventilation device throughout the entire year, a temperature sensor is
integrated into the Xenion EFP reversible fan. This measures the temperature
of the air flow. If the temperature falls below +5 °C, the reversible fan is
automatically switched to extract air mode for 4 cycles. This allows the
thermal accumulator to heat up again and prevents cooling of the interior due
to cold supply air. During this phase, the operating mode that has been set on
the controller is ineffective. Subsequently, the controller switches the
ventilation device back to the originally selected mode.
As standard, a washable ISO Coarse 60 % class dust filter is integrated into
the inner cover. This filters coarse dust and allergenic particles (such as
coarse flower pollen) from the air before they can enter the interior. The
dust filters can be used regardless of the season. Optional pollen and
activated carbon filters are available for special requirements.
iV-Office ventilation device | Installation instructions
11
SYSTEM OVERVIEW: IV-OFFICE VENTILATION DEVICE
2.3 Control elements
The ventilation device is operated via an inVENTer system controller.
Depending on the controller, different operating modes and functions can be
set.
Basic controls
Designation
sMove
Number of controllable ventilation devices Multi-zone control
Operating concept
s4: Max. 2 s8: Max. 4 No
· Touch
Operating modes Functions
· Heat recovery · Unidirectional ventilation · OFF (standard version only)
· Pause-Function (1 … 8 h) · Boost-Function (1 h)
Fan speed
Device communication External interface
infinitely adjustable, 4 Output levels, predefined
Cable
1 potential-free switching contact per controller: · Pressure switch (NC) ·
Other sensors (NO)
12
iV-Office ventilation device | Installation instructions
SYSTEM OVERVIEW: IV-OFFICE VENTILATION DEVICE
Multi-zone control Designation
MZ-Home
ON 12
Number of controllable ventilation devices Multi-zone control Operating
concept
Operating modes
Functions
Operating Unit & Clust-Air module
Max. 8 (excl. sensors)
max. 4 zones with max. 2 devices [plus sensors] per zone
· Touch · Weekly timer
· Heat recovery · Through-ventilation · OFF
· Pause function (1… 8h) per zone
· Dehumidification with variable air volume flow
Fan speed Device communication
4 Output levels, freely selectable
Cable
External interface
1 potential-free switching contact per Clust-Air module (max. 4) · Pressure switch (NC/NO) · Other sensors (NO)
For detailed information, see the controller’s installation and operating instructions.
iV-Office ventilation device | Installation instructions
13
PREPARING FOR INSTALLATION
3 Preparing for installation
3.1 Installation position
· The installation location can be derived from the position suggested by the
ventilation planning. The exact positioning of the individual devices and
control devices must be checked on site and, if necessary, adjusted. Consult
the responsible planner about this! For optimum function, it is recommended
that the ventilation device is installed at the appropriate point in the upper
wall area (e.g. 1.80 m from the upper edge of the finished floor [UEFF]).
· Do not place the ventilation device near radiators, indoor air thermostats,
sensitive furniture or above pictures.
· Do not install the device in places where direct contact with water spray is
possible. Observe the specifications of VDE 0100 when choosing the
installation location.
Minimum distances of the wall opening for the ventilation device:
· Minimum distances to components / building elements on the interior and
exterior wall:
NOTICE: Malfunction due to incorrect positioning of the ventilation device. ·
Note insulation thickness and possibly shutters! · Do not install near
radiators! · Observe minimum distance of 1.2 m to adjacent air openings!
Termination component
Flex Office weather protection hood Flair XL inner cover
Distance from centre of hole on the
exterior wall [mm]
Internal wall [mm] frontal [mm]
450 (top) 250 (side, bottom)
250 circumferential 300
· between two ventilation devices (pair of devices) operating in push-pull mode in a room
A Horizontal or vertical on the same wall
C Installation with height offset
1,2 m 0,75 y
1,2 m y
B Installation over corner
1,0 m 1,4 m
1,0 m
14
iV-Office ventilation device | Installation instructions
PREPARING FOR INSTALLATION
3.2 Position of the wall opening
For the positioning of the wall sleeve of other variants of your ventilation
device ,see the installation instructions for your specific external
termination. Standard variant ventilation device:
Ø270
250 5
1 4
2
1
250
5
4
330
165
165
3 279
279
2
330
43
Position of wall opening
Position of Simplex wall sleeve system
Figure 2: Dimensional drawing of the iV-Office wall opening (interior view)
1 Wall opening (Fig. 2, left) Simplex wall installation system (Fig. 2, right)
2 Contour of weather protection hood3)
3 Reveal
4 Door/window frame 5 Bottom edge of lintel4)
-
Minimum distance to adjacent components on the interior wall
-
Recommendation: Attach the hood at lintel height
-
Ensure a minimum distance to adjoining components on the exterior wall 4) Note insulation thickness and any roller shutters
3.3 Dimensions
Designation Wall opening for wall sleeve R-D250 wall sleeve Flex Office
weather protection hood Flair-XL V-280×280 inner cover
Depth/length [mm]
Width [mm] Height [mm]
Wall thickness1)
495 (745)
23 88
279
280
Ø270 Ø250
313 280
-
with render, insulation, masonry and plaster
-
Open
iV-Office ventilation device | Installation instructions
15
PREPARING FOR INSTALLATION
3.4 Sectional drawing of the ventilation device
For sectional drawings of other variants of your ventilation device, see the
installation instructions for your specific external termination. Sectional
drawing of the iV-Office ventilation device, standard variant
8
9
1 1 2°
2 7
313 Ø250
280
6
88
D
265
5
4
Wandstärke 260
C
B
Figure 3: Sectional drawing of the iV-Office ventilation device
A Interior plaster/ interior structure B Masonry
C Insulation D Render
3
63
A
1 Inner cover base plate 2 Flair XL adapter 3 Inner cover panel with SDE sound
insulation insert 4 R-D250 wall sleeve 5 Sound insulation lining made of
Inventin
6 Flex Office weather protection hood 7 Flex Office ring insert (pre-
installed) 8 Thermal accumulator 9 inVENTron R-D200:
Xenion EFP reversible fan embedded in double guiding vane
16
iV-Office ventilation device | Installation instructions
PREPARING FOR INSTALLATION
21
3.5 Dimensional drawings of components
Flex Office weather protection hood
A A
A
5
23
30
4 x Ø4,8
313 148
5 1
1
7
2
Ø191
313
252
A 279
6
88
4
3
221
Weather protection hood cover
Weather protection hood base plate
Figure 4: Dimensional drawing of the Flex Office weather protection hood
1 Weather protection hood base plate 2 Flex Office insert (pre-assembled) 3 Exterior wall fixing hole
4 Protective grid 5 Weather protection hood cover 6 Drip rail
Flair XL inner cover
A
5
4
1
6
215 233
2
3 7
A
63
215
280
Figure 5: Dimensional drawing of the Flair XL V-280×280 inner cover incl. SDE
1 Inner cover panel 2 SDE sound insulation insert 3 Flair XL adapter 4 Spacer (4 x)
5 Interior wall fixing borehole 6 Inner cover base plate 7 Pass-through for
controller connecting
cable
iV-Office ventilation device | Installation instructions
17
INSTALLATION AND ASSEMBLY
4 Installation and assembly
i
Read the section carefully before installation to avoid installation errors. The installation and connection of the ventilation system must be carried out by qualified personnel.
4.1 Check the scope of supply
Check the delivery for completeness and transport damage upon receipt using
the delivery note. Report missing items immediately.
These assembly instructions describe the standard version of the product.
Details of the variants’ scope of supply can be found in the separately
available installation instructions for the respective system component.
1a 2
4x
11 External termination
1b
4x
1c
1 a: Flex Office WSH cover 1 b: Flex Office WSH base plate
4x
1 c: Exterior wall fixing elements 1 d: Sealing tape
1d 2a
The Flex-Office weather protection cover is available in different colours and
materials (stainless steel / aluminium [with increased salt resistance]) and
must be
ordered according to the desired colour
and texture.
22 R-D250 wall sleeve
2b
2 a: Styrofoam discs
2 b: Mounting wedges set
3f
4a
4b
18
3a
3b 3c 3d
33 Einschub Wärmespeicher iV-Office 3 a: Insulated thermal accumulator 3 b: R-D200 guiding vane 3 c: Xenion EFP reversible fan 3 d: Slim guiding vane (16 mm) 3 e: BUS plug connection 3 f: Sound insulation lining
3e
4x 4x 4c
44 Innenblende Flair XL
4 a: Flair XL insert (pre-installed)
4 b: Inner cover base plate
4d
4 c: ISO Coarse 60 % filter
4 d: Interior wall fixing material
WSH = Weather proteccion hood
iV-Office ventilation device | Installation instructions
INSTALLATION AND ASSEMBLY
4.2 Create wall opening
CAUTION Falling masonry when creating the wall opening can lead to physical injuries and /or damage to property! · Install protection against falling masonry on building exterior. · Remove objects from the immediate vicinity of the building’s exterior.
In new buildings, we recommend using the optional Simplex D250 wall installation system.
Observe the minimum distances and the installation position of the ventilation device. Consult your planner before installation if you are at all uncertain!
Create the wall opening through core drilling Power drill with core drilling attachment or milling drill Ø 270 mm
Ø 270
Requirements: · The masonry must be dry and in a load-bearing
condition. · No load-bearing elements in the position of the drill
hole.
Drill a wall opening, Ø 270 mm with a slope of 1° to 2° to the exterior wall.
! The wall sleeve must have a slope of 1 2° to the exterior wall side.
Alternatively the drilling can be carried through with a slope.
The wall opening for the ventilation device has been created.
iV-Office ventilation device | Installation instructions
19
INSTALLATION AND ASSEMBLY
4.3 Laying the cables to the wall opening of the ventilation device
CAUTION Exposed electrical components. Injury caused by live components (16 V
DC)! · Installation and connection must only be performed by qualified and
trained personnel.
Once the wall opening has been created, the cables necessary for operating the
ventilation system are laid to the wall opening for the ventilation device.
They connect the valve gate of the ventilation device with the control
components and thus establish signal transmission and/or voltage transmission
between the controller and the Xenion EFP reversible fan.
NOTICE: Cable to the wall opening of the ventilation device not
laid. No connection of the reversible fan possible!
Routing of the cables to the wall opening for the ventilation device
must be done in this installation step. The routing of the connecting
cables between the controllers and the Xenion EFP reversible fan
45°
is not part of this documentation. For more information, see the in-
stallation and operating instructions for the corresponding controller.
Cable to the wall opening of the ventilation device
The following cables, depending on the control device, are laid to the wall
opening for the ventilation device:
sMove MZ-Home
Use
Cable type
Operating voltage fan and device communication
Stranded cable 6 16 V DC,
e. g.: LiYY 3×0.75 mm²
Cable origin
sMove operating device
Clust-Air module CAM17 in the ventilation zone
20
iV-Office ventilation device | Installation instructions
INSTALLATION AND ASSEMBLY
Principle sketches for cable laying
The corresponding connection diagrams and assembly steps for installing the controller are not part of this documentation! They can be found in the installation and operating instructions for the respective control device.
sMove and MZ-Home controllers
6 16 V DC 230 V AC
One after the other:
Cable type LiYY, 3-wire, wire cross-section 0.75 mm2, length see controller
Switching power supply device
Control device:
sMove: Control device MZ-Home: Clust-Air module
Operated in pairs
Ventilation devices
Star-shaped:
Cable type LiYY, 3-wire, wire cross-section 0.75 mm², length max. 33 m
Switching power supply device
Control device:
sMove: Control device MZ-Home: Clust-Air module
Terminal blocks
Ventilation devices
Operated in pairs
iV-Office ventilation device | Installation instructions
21
INSTALLATION AND ASSEMBLY
4.4 Installing the wall sleeve
Measuring tape, angle grinder, spirit level, non-pressing 2K polyurethane foam, cutter, mounting wedge set and styrofoam discs
DC B
X = ?
Requirements: · The wall opening Ø 270 mm is finished. · The cables to the
wall opening of the ventilation
device has been laid.
A
Determine the exact wall thickness X:
D = Exterior rendering, incl. other superstructures
if applicable.
C = Insulation, if applicable incl. air gap
B = Masonry, incl. relining if applicable
A = Interior plaster
X = A+B+C+D
X Cut the wall sleeve to the determined dimension X.
! Be careful not to cut away the cut-out for the fan connecting cable.
Remove the styrofoam discs from the wall sleeve.
Insert the wall sleeve into the wall opening so it is flush with the interior
wall. Note the thickness of the plaster.
! The recess for the connecting cables is located on the interior wall side
and near the cables laid to the wall opening.
Guide all connecting cables through the cut-out in the wall sleeve.
22
iV-Office ventilation device | Installation instructions
1 2°
INSTALLATION AND ASSEMBLY
NOTICE: Accumulation of condensation water in thewall sleeve. Damage to
exterior wall and masonry and the building structure! · Attach the wall sleeve
with a slope of
1° to 2° to the exterior wall.
Attach the wall sleeve inside and outside with the mounting wedges so that
there is a slope of 1 2° to the exterior wall.
Check the angle of the wall sleeve using a spirit level.
NOTICE: Contamination of the wall sleeve, e. g. by plaster residues, leads to
damage to the sound insulation lining made of Inventin! · Before foaming the
free space between the
wall sleeve and masonry, insert styrofoam discs.
Insert the styrofoam discs into the wall sleeve from the inside and outside.
24 h
NOTICE: Interruption of the thermal insulation composite system. Damage to the
building structure! · During installation, replace the wall
structure as far as the wall sleeve. · Observe the necessary barrier levels.
Foam-seal the gap between the wall sleeve and masonry all the way around with
non-pressing 2K polyurethane foam.
Cut off the excess, hardened 2K polyurethane foam and protruding mounting
wedges so they are flush with the exterior and interior wall.
! Take care not to damage the connecting cable on the interior wall.
If necessary, trim the wall sleeve so it is flush with the render.
Deburr the edges.
The wall sleeve is installed.
iV-Office ventilation device | Installation instructions
23
INSTALLATION AND ASSEMBLY
4.5 Installing the ventilation device’s external termination
The installation of the external termination variants is not part of this documentation! It can be found in the installation instructions for the respective external termination.
NOTICE
Installing on an unfinished exterior wall leads to damage to the exterior
wall! · Only install the external termination once the exterior wall is
finished and has fully dried.
NOTICE Penetration of condensation water and/or algae accumulation around the
external termination leads to damage to the masonry/exterior wall and/or
discolouration of the façade! · Secure sealing tape all the way around the
weather protection hood before installing the
external termination. · Before installation, carry out a biocidal pre-
treatment/water-repellent pre-treatment of the
surface around the weather protection hood (consult your planner regarding
this!).
Installing the Flex Office weather protection hood
Spirit level, pen, power drill with Ø 8mm drill bit, cordless screwdriver, rawl plugs (wallplugs for insulation for insulated exterior walls), permanently elastic external sealant, sealing tape, screws
Requirements: · The exterior wall is completed and even. · The wall sleeve is installed.
+ Simplex
Remove the styrofoam disc from the wall sleeve on the exterior wall side.
Slide the base plate with the pre-assembled insert
onto the projecting wall sleeve.
! The protective grid is directed towards the floor.
Level the base plate using a spirit level.
ø 8 mm
Mark the four drill holes (blue arrow).
Drill the four holes with Ø 8 mm, min. 50 mm deep.
24
iV-Office ventilation device | Installation instructions
INSTALLATION AND ASSEMBLY
i
TIP: Do not apply the sealing tape until immediately before installing the base plate.
This prevents the sealing tape from swelling
too much and makes installation easier.
From the exterior wall side, attach the 9-mm sealing tape circumferentially
flush with the guide on the base plate.
! Do not seal the fixing holes!
Insert the rawl plugs into the boreholes.
4 x
Screw the base plate into the rawl plugs using 4
screws and washers.
i
TIP: When attaching the base plate to exterior walls with insulation or when using the
Simplex wall installation system, use wallplugs
for insulation for fixing purposes. These are
not included in the scope of supply, they are
available as an option.
NOTICE: If the joint between the base plate and the exterior wall is
incorrectly sealed, the cover cannot be fitted. · Seal only the upper joint
between the base
plate and the exterior wall.
Seal the upper joint between the base plate and the exterior wall with a
permanently elastic exterior sealant.
Place the cover onto the base plate from the top.
Slide the cover downwards as far as the stop.
! The guides on the cover hook in behind the base plate.
The Flex Office weather protection hood is installed.
iV-Office ventilation device | Installation instructions
25
INSTALLATION AND ASSEMBLY
4.6 Inserting the thermal accumulator insert
Inserting the sound insulation lining
NOTICE: The sound insulation lining is made from Inventin, a high-performing,
patented material for use in decentralised ventilation devices. It absorbs
sound waves from outside and from the device itself (sound transmission and
inherent sound). Inventin is a sensitive material. · To safeguard its sound-
insulating function, handle the lining with care.
Cutter
500 / 750 mm
Requirements: · The external termination is fitted.
Remove the styrofoam disc from the wall sleeve.
Position the front surfaces of the sound insulation lining together.
Push the sound insulation lining with light tension into the wall sleeve until
it stops.
! Position the abutting surfaces (red arrow) in the upper section of the wall
sleeve (approx. 12 o’clock).
Make sure that the sound insulation lining made of Inventin is pushed into the ring insert on the weather protection hood.
26
iV-Office ventilation device | Installation instructions
INSTALLATION AND ASSEMBLY Shorten the sound insulation lining on the inner
wall
side with a cutter so it is flush with the wall sleeve.
! Do not damage the connecting cable on the interior wall.
The sound insulation lining is inserted.
iV-Office ventilation device | Installation instructions
27
INSTALLATION AND ASSEMBLY
Inserting the thermal accumulator
NOTICE Do not store/stack the thermal accumulator insert outside the wall
sleeve as doing so will damage the thermal accumulator’s ceramic. · Insert the
thermal accumulator immediately after removing it from the packaging.
Requirements: · The external termination is fitted. · The sound insulation
lining is inserted.
Insert the thermal accumulator from the interior into the lined wall sleeve.
! · The handle points towards the interior. · The connecting cables protrude
into the interior.
Slim 28
Carefully push the thermal accumulator towards the external termination until
it stops.
! Do not damage the sound insulation lining made from Inventin.
Insert the inVENTron from the interior into the wall sleeve so that you can
reach the BUS plug connection.
! The narrow Slim guiding vane [16 mm] is aligned towards the interior.
The thermal accumulator insert has been inserted.
iV-Office ventilation device | Installation instructions
INSTALLATION AND ASSEMBLY
4.7 Installing the inner cover base plate
The assembly of any interior termination variants is not part of this documentation! It can be found in the separate installation instructions for the respective component.
Preparing for installation:
i
The correct installation of the inner cover requires that the installation position of the base plate (installation position arrow pointing upwards) is not changed.
To ensure that, even in the event of a different cable routing, correct connection of the reversible fan is possible, the orientation of the adapter can be modified (e. g. top right cable connection). The adapter for the Flair XL inner cover is pre-assembled at the factory so that the cable entry is located at the bottom left when it is being attached. If the cable is long enough, it can optionally be laid between the ring insert and the sound insulation lining to the cable entry.
Before installation, check whether any adjustment of the inner cover adapter needs to be made. If necessary, change the position of the cable entry so that it matches the conditions of the installation location:
Remove the base plate from the adapter by unhooking it on all 4 sides.
TIP: Once the base plate has been removed from the adapter, you can make the
drill hole
i markings for attaching the inner cover to the interior wall.
4 X 90°
Rotate the adapter by 90° in each case until the positions of the cable entry and connecting cable match. Bottom left cable entry = position ex works
Clip the adapter into the base plate so that · The position arrow on the base plate is pointing upwards, and · The positions of the cable entry and connecting cable match.
The inner cover base plate is prepared.
iV-Office ventilation device | Installation instructions
29
INSTALLATION AND ASSEMBLY
Spirit level, pencil, power drill, cordless screwdriver / Phillips
screwdriver, rawl plugs, screws
Requirements: · The thermal accumulator insert has been installed.
Position the inner cover adapter with the base plate inserted centrally to the
wall sleeve on the interior wall.
Align the inner cover adapter including the inserted base plate with a spirit
level.
Mark the four corner drill holes.
ø = 6 mm
Drill the four holes with Ø 6 mm, min. 40 mm deep. Insert the rawl plugs.
4 x 30
40 mm
Route the fan BUS from behind through the cable entry of the prepared base plate.
NOTICE: If the base plate of the inner cover is twisted, the inner cover panel
cannot be fitted correctly! · The position arrow on the inner cover base
plate must always point upwards.
Screw the base plate into the rawl plugs with the screws.
! The position arrow on the base plate points upwards.
The inner cover base plate is fitted.
iV-Office ventilation device | Installation instructions
INSTALLATION AND ASSEMBLY
4.8 Electrical connection of the reversible fan
The function of the iV-Office ventilation system requires the simultaneous
operation of two iV-Office ventilation devices in push-pull mode. This section
therefore describes the connection of a pair of devices, not a single device.
NOTICE Incorrect electrical connection will damage the fan motor! · Always connect the ventilation device to the mains supply via a controller. · Ensure the correct sequence of the wire colours so that the fans start.
Stripping tool, screwdriver, blade, wire end ferrules (3 x 0.75 mm²)
3 x 0.75 mm²
Requirements: · The reversible fan is inserted into the wall sleeve. · The
base plate or inner cover holding plate is fitted.
Shorten the fan BUS, 3-wire, to your determined wall thickness minus 200 mm.
Remove the cable sheath from the fan BUS.
NOTICE: Using the wrong wire end ferrules to connect the cables in the plug-in
connector will lead to a short circuit in the fan BUS! · Use wire ferrules
with collars to connect
the wire strands.
Press wire end ferrules onto the cables, cable cross-section 0.75 mm².
Loosen the plug connections on the reversible fans of the two ventilation devices.
Align the plug connectors on the ventilation devices so that the clamping screws on both are facing in the same direction (e.g. upwards).
iV-Office ventilation device | Installation instructions
31
INSTALLATION AND ASSEMBLY
DIR1 (III) VOUT+ (IV) DIR2 (V)
ETA
(Exhaust air)
In paired operation, one reversible fan starts in extract air mode, the other
in supply air mode. This start direction is determined by the different
connection sequence of the three fan BUS cables in the plug-in connector.
Secure the three fan BUS cables in the plug-in connector.
! Pair one with starting direction with exhaust air and the other with
starting direction supply air.
DIR2 (V) VOUT+ (IV)
DIR1 (III)
Exhaust air mode: · (White) cable DIR (III) in the left pole. · (Green) cable VOUT+ (IV) in the middle pole. · (Brown) cable DIR2 (V) in the right pole.
SUP
(Supply air)
Supply air mode: · (Brown) cable DIR2 (V) in the left pole. · (Green) cable VOUT+ (IV) in the middle pole. · (White) cable DIR1 (III) in the right pole.
Reconnect the connected plug-in connector to the plug-in connector on the reversible fan.
Start direction extract air mode:
Start direction supply air mode:
6 5
1
CW VIN+ CCW
6 5
1
CW VIN+ CCW
DIR1 (III) VOUT+ (IV)
DIR2 (V)
2 3
DIR2 (V) VOUT+ (IV) DIR1 (III)
2 3
4
4
· The clamping screws of the plug connection are directed to the same side. · The connections of the white and brown cable are swapped.
1 Fan cable [to the fan] 2 Plug-in connector on the fan cable 3 Plug-in connector on the controller cable 4 Fan BUS [to controller]
5 Clamping screws on the controller plug-in connector
6 Clamping screws on the fan plug-in connector
32
iV-Office ventilation device | Installation instructions
INSTALLATION AND ASSEMBLY
Plug-in connector Plug-in connector (cable coming from controller)
on the fan cable Start direction extract air
Start direction supply air
Terminal block
Colour
Terminal block
Meaning
Colour
Terminal block
Meaning
Colour
CW
Blue DIR1 (III) Signal direction 1 White DIR2 (V) Signal direction 2 Brown
VIN+
Red
VOUT+ (IV) Operating voltage Green VOUT+ (IV) Operating voltage Green
CCW
Black DIR2 (V) Signal direction 2 Brown DIR1 (III) Signal direction 1 White
The reversible fan is connected to the controller.
4.9 Check function and complete fan installation
Set unidirectional ventilation operating mode (DL – through ventilation) on the connected controller (see the controller’s installation and operating instructions).
Make sure that all reversible fans rotate in the direction appropriate to their connections.
Start direction extract air mode:
Start direction supply air mode:
Direction of fan clockwise inVENTron is connected and installed.
Direction of fan counter clockwise
iV-Office ventilation device | Installation instructions
33
INSTALLATION AND ASSEMBLY
4.10 Installing the inner cover panel
The assembly of any internal termination variants is not part of this
documentation! It can be found in the separate installation instructions for
the respective component.
Requirements: · The thermal accumulator insert has been installed.
Ensure you install the dust filter properly to avoid a malfunction of the
ventilation device.
4 x CLICK
Insert the dust filter into the base plate.
! · Push the filter ring firmly between the fixing tabs and the inner edge of
the base plate.
! · The tab on the filter ring faces the inside and is located in the cut-out
provided in the base plate.
Place the panel on the four spacers.
! The position arrows on the back of the inner cover panel point upwards.
Check: The inVENTer logo is located at the bottom right
Press the locking lugs inwards on the spacers.
Slide the inner cover panel onto the spacers. All spacers noticeably snap in.
The inner cover panel is fitted.
34
iV-Office ventilation device | Installation instructions
TECHNICAL DATA
5 Technical data
5.1 General specifications
Feature Operating range [°C] Minimum wall thickness [mm] Extract air/outdoor
air
Flow rate in reversed mode [m³/h] Extract airflow [m³/h] (EN 13141-8) Sound
pressure level, distance 2 m [dB (A)] Standard sound level difference [dB]
Thermal efficiency of heat recovery (‘w) Input voltage [V DC] Power
consumption [W] Specific fan power input [W/(m³/h)] Protection class (EN
61140) Type of protection (EN 60529) Standard filter filter class
ISO 16890 EN 779:2012 Sensitivity of the air flow at ± 20 Pa (EN 13141-8)
Electrical protection area (in accordance with VDE 0100)
Frost protection
Value -20 50 260 Free from aggressive gases, dust and oils 10 45 20 90
14 41 43 52 0.88 6 16 1 5 0.14 III IP20
ISO Coarse 60 % G4 S2
Outside protection areas 0 2
Automatic by reversing operation (down to -20 °C)
Conformity
iV-Office ventilation device | Installation instructions
35
TECHNICAL DATA
5.2 iV-Office energy label according to ErP Directive, Regulation 1254/2014
On the energy label you will find the following information from the product
data sheet: · Energy efficiency class (SEC class) · Sound power level Lwa ·
Maximum air flow (supply air)
iV-Office
Demand-controlled Manually controlled
sMove with sensors Easy Connect e16
MZ-Home
sMove without sensor
A+
A+
A
A
B
C
D
E
F
G
49
90 m3/h
dB (A)
ENERGIA · · · ENERGIJA · ENERGY · ENERGIE · ENERGI
2016
1254/2014
36
iV-Office ventilation device | Installation instructions
TECHNICAL DATA
5.3 Specifications according to ErP Directive, Regulation 1254/2014
iV-Office ventilation device, demand-controlled:
iV-Office product data sheet according to EU Ordinance 1254/2014 dated 11 July 2014
Pt Description
Values
a Supplier
inVENTer GmbH
b Model identifier
iV-Office
Cold
c
SEC class / Specific Energy Consumption (SEC) [kWh/(m²a)]
Average
Warm
-88.481
A+
-44.234
-18.886
d Ventilation type
BVU
e Type of drive
2
f Type of heat recovery system
Regenerative
g Degree of temperature change t [%]
88
h Maximum air flow rate [m³/h]
90
i
Electrical input power (incl. control) [W]
9
j
Sound power level Lwa [dB (A)]
49
k Reference air flow [m³/h]
63
l
Reference pressure difference [Pa]
0
m SEL [W/m³/h]
0.14
n Control factor
0.65
o Internal and external transfer [%]
n. a.
p Mixing quota [%]
n. a.
q
Position and description of the indicator for filter change
Control device
Instructions regarding controllable supply and extract
r air grilles on the façade (unidirectional ventilation
None
devices only)
s Internet address
www.inventer.de
t Sensitivity to pressure changes [%]
17.8
u Airtightness between interior and exterior [m3/h]
6.3
v Annual power consumption [kWh/(m²a)]
0.82
Cold
w
Annual savings Heating energy [kWh/(m²a)]
Average
Warm
90.61 46.32 20.94
iV-Office ventilation device | Installation instructions
37
TECHNICAL DATA
iV-Office ventilation device, manually controlled:
iV-Office product data sheet according to EU Ordinance 1254/2014 dated 11 July 2014
Pt Description
Values
a Supplier
inVENTer GmbH
b Model identifier
iV-Office
Cold
c
SEC class / Specific Energy Consumption (SEC) [kWh/(m²a)]
Average
Warm
-82.817
A
-39.977
-15.435
d Ventilation type
BVU
e Type of drive
2
f Type of heat recovery system
Regenerative
g Degree of temperature change t [%]
88
h Maximum air flow rate [m³/h]
90
i
Electrical input power (incl. control) [W]
9
j
Sound power level Lwa [dB (A)]
49
k Reference air flow [m³/h]
63
l
Reference pressure difference [Pa]
0
m SEL [W/m³/h]
0.14
n Control factor
1
o Internal and external transfer [%]
n. a.
p Mixing quota [%]
n. a.
q
Position and description of the indicator for filter change
Control device
Instructions regarding controllable supply and extract
r air grilles on the façade (unidirectional ventilation
None
devices only)
s Internet address
www.inventer.de
t Sensitivity to pressure changes [%]
17.8
u Airtightness between interior and exterior [m3/h]
6.3
v Annual power consumption [kWh/(m²a)]
1.93
Cold
w
Annual savings Heating energy [kWh/(m²a)]
Average
Warm
87.78 44.87 20.29
38
iV-Office ventilation device | Installation instructions
SCOPE OF SUPPLY
6 Scope of supply
Standard components
All standard components are also available as spare parts. Further accessories
and spare parts can be found in the separate accessories overview. Contact
your local distributor to order accessories for your ventilation system
Component
Item number
iV-Office
1001-0213
Standard variant external termination2): Weather protection hood including sealing tapes
Flex-Office weather protection hood, white RAL 9016
1508-0181 | 1508-01851)
Flex-Office weather protection hood, grey RAL 9006
1508-0182 | 1508-01861)
Flex-Office weather protection hood, Nord RAL 7011
1508-0184
Flex-Office weather protection hood, anthracite RAL 7016 1508-0183 | 1508-01871)
Flex-Office weather protection hood, custom colour
1508-0190 | 1508-01881)
Wall sleeve with styrofoam discs and mounting wedges
Wall sleeve R-D250x495
1506-0072
Wall sleeve R-D250x745
1506-0073
Thermal accumulator insert
iV-Office thermal accumulator insert [incl. Inventin 495 mm] 1507-0028
iV-Office thermal accumulator insert [incl. Inventin 745 mm] 1507-0029
Inner cover
Flair XL V-280×280 inner cover, white, incl. SDE
1505-0050
- Special variant: consisting of aluminium, with increased salt resistance 2) Item numbers of any external termination variants in the separate installation instructions of the respective external termination.
iV-Office ventilation device | Installation instructions
39
TROUBLESHOOTING
7 Troubleshooting
Troubleshooting
Fault
Possible cause
Remedy
Fan failure Fan does not switch off. Low flow rate
Noises
Supply air is cold
No electrical power.
Installation error.
Fan defective. Controller/power supply defective. Faulty controller. Panel
closed. Fans are not operating in paired mode. The rotational speed of the fan
is too low. Foreign body in the fan.
Thermal accumulator is not correctly positioned in the wall sleeve. The
rotational speed of the fan is very high.
Installation error.
The controller is operating in ventilation mode.
Check fuse. Check wiring for correct polarity. Check all connectors for
correct fit. Check the use of wire ferrules. Replace fan.
Switching controller/power supply.
Replace controller.
Open panel. Connect the first fan in extract air mode and the second fan in
supply air mode.
Increase the output level.
Remove foreign body from the fan. Clean the ventilation system. Slide the
thermal accumulator out of the wall sleeve. Insert it again. Slide the thermal
accumulator into the wall sleeve as far as the end-stop tape. Set a lower
output level on the controller. Make sure that the device label on the Xenion
EFP fan is directed towards the thermal accumulator. Check the connector plug
on the controller. The connector plug must be sitting firmly in the connector
housing. Select heat recovery mode on the controller.
40
iV-Office ventilation device | Installation instructions
WARRANTY AND GUARANTEE
8 Warranty and guarantee
Warranty
Outside Germany, the national warranty provisions of the country in which the
system is sold apply. Please contact the distributor for your country.
The warranty covers all defects that were present at the time of purchase.
Failure to observe the intended use will invalidate all warranty claims.
Manufacturer guarantee
inVENTer GmbH provides a five-year guarantee for all electrical components and
the wall sleeve, as well as a thirty-year guarantee on the ceramic component
of the thermal accumulator. This covers premature product wear.
Further information about the warranty is available at
www.inventer.eu/guarantee
9 Service
Claims
Check the delivery for completeness and transport damage upon receipt using
the delivery note. Report missing items immediately, and at the latest within
14 days to your supplier, distributor or factory representative.
Warranty and guarantee claims
In the case of a warranty or guarantee claim, contact your local distributor
or factory representative.
In all cases, please return the complete device to the manufacturer. The
warranty is an additional offering by the manufacturer and in no way affects
the applicable law.
Accessories and spare parts
To order components for your ventilation device, contact your nearest
distributor or our service staff.
Technical customer service
For technical support contact our service staff:
+49 (0) 36427 211-0 +49 (0) 36427 211-113 info@inventer.de www.inventer.eu
iV-Office ventilation device | Installation instructions
41
inVENTer GmbH Ortsstraße 4a D-07751 Löberschütz Germany www.inventer.eu
Subject to modifications. We accept no liability for printing errors.
Item number: 5001-0043 Version: 2.1 01/2024
References
- Dezentrale Lüftungsanlagen - unsichtbar, energieeffizient, lautlos
- Decentralized ventilation systems - invisible, energy-efficient, silent
- inVENTer manufacturer guarantee - trust in quality
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>