inventer MFVI32-09WFI Air Conditioning System User Manual
- June 6, 2024
- inVENTer
Table of Contents
- Parts and Functions
- Outdoor Unit
- Remote controller
- COPILOT Operation
- HEALTH AIRFLOW Operation
- ON/OFF operation and test operation
- UV-C Lamp
- Pair the Air Conditioner
- Troubleshooting:
- Indoor Unit Installation
- Indoor Unit Installation
- Unloading of indoor unit body
- Removing the wiring cover
- When connecting the cable before installing the indoor unit
- Maintenance
- Replacement of Air Purifying Filter
- Troubleshooting
- Specifications
- Documents / Resources
AIR CONDITIONING SYSTEMS
WALL-MOUNTED UNIT
• USER’S MANUAL
MODELS:
MFVI32-09WFI/MFVO32-09
MFVI32-12WFI/MFVO32-12
MFVI32-18WFI/MFVO32-18
MFVI32-24WFI/MFVO32-24
Read the precautions in this manual carefully before operating the unit.
This appliance is filled with R32.
Keep this manual where the user can easily nd it.
WARNING:
- Do not use means to accelerate the defrosting process or to clean, other than those recommended by the manufacturer.
- The appliance must be stored in a room without continuously operating ignition sources (for example open flames, an operating gas appliance or an operating electric heater).
- Do not pierce or burn.
- Be aware that refrigerants may not contain an odor.
- The appliance must be installed, operated, and stored in a room with a floor area larger than 3
- If the supply cord is damaged, it must be replaced by the manufacturer,its service agent or similarly qualified persons in order to avoid a hazard.
- This appliance can be used by children aged 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision.
- The wiring method should be in line with the local wiring standard.
- All the cables shall have got the European authentication certificate. During installation, when the ·connecting cables break off, it must be assured that the grounding wire is the last one to be broken off. The explosion-proof breaker of the air conditioner should be an all-pole switch. The distance between its two
- contacts should not be any less than 3mm. Such means for disconnection must be incorporated in the wiring.
- Make sure installation is done according to local wiring regulations by professional persons.
- Make sure the ground connection is correct and reliable. A leakage explosion-proof breaker must be installed.
- Do not use a refrigerant other than the one indicated on the outdoor unit(R32) when installing, moving or repairing. Using other refrigerants may cause trouble or damage to the unit, and personal injury.
Parts and Functions
Indoor Unit
Display board ****
- Signal receiver hole
- HEAT display
- DRY display
- HEALTH display
- COOL display
- Ambient temp. display When receiving the remote control signal, display the set temperature.
- WIFI display
- SENSOR display
Display board
- Remote signal receiver (A beeping sound is generated when a signal from the remote controller is received.)
- Power indicator (Lights up when the unit starts.)
- Timer mode indicator (Lights up when timer operation is selected.)
- Operation mode indicator (lights up when the compressor is on.)
- WIFI
Outdoor Unit
- OUTLET
- INLET
- CONNECTING PIPING AND ELECTRICAL WIRING
- DRAIN HOSE
Remote controller
The outer side of the controller
1. ECOPILOT button
2. DRY button Used to set DRY operation.
3. COOL button Used to set COOL operation.
4. TEMP button used to change setting temperature
5. ON / OFF button
.6 Display of each function status
7. Operation mode display
8. WIFI and CLOCK display | 9. TEMP display
10. Humidity display
11. FAN SPEED display
12. SWING display Swing up/down display swing left/right display
13. TIMER ON display
TIMER OFF display
CLOCK display
14. FAN button
15. QUIET button
16. HEAT button
17. ECO button power-saving
function
---|---
NOTE:
a. Humidity display is unavailable on some models
b. If the model you buy has a WIFI function, press the“ON/OFF” button for 5s
to emit the WIFI binding signal. Once in the binding mode, the APP will show
how to bind.
Operation
18. TIMER button
19. CLOCK button
20. 10 ºC button special heating set function: 10 degree heating maintaining
(valuable for RS)
21. HEALTH button
22. SMART button Used to set SMART operation. (This function is unavailable
on some models.)
23. SWING up/down button
24. SWING left/right button
25. SLEEP button
26. HEALTH AIRFLOW button
27. LIGHT button
Control the lightening and extinguishing of the indoor LED display board.
28. CODE button A-b yard
29. APPLY button
30. °F/°C button
Note:
1. SMART+SLEEP: When the light-sensing function is enabled, the appliance
will be in the mode. If the appliance detects that indoor light is low for
several minutes, the light-sensing function starts automatically. If the
appliance detects no movements of people for 20 minutes, and the detected
light is low, it will enter the “SMART+SLEEP” mode automatically. The
appliance will operate as per the sleep curve.(See the“SLEEP” function in Page
7). Conditions to exit:
- The appliance detects that the indoor light is stronger than the setting value for 20 minutes.
- The appliance is in the 8h “SMART + SLEEP” mode.
- The “LIGHT SENSING” function is disabled.
When any of the above conditions is met, the appliance will exit from the “SMART+SLEEP” mode. Once out of the “SMART+SLEEP” mode, the appliance will operate under the operation status initially set on the remote controller.
Note:1) This function is not available in the “FAN” mode. 2) This function is not available in the “SLEEP” mode. - When it is in the “REMOTE SLEEP” mode or the “TIMER”is on, the appliance will exit from this function.
- Light sources like indoor lamps and TV’s LED light,and frequent movement s
of pets will affect this function.
2. Press “HEALTH”+“HEALTH AIRFLOW” simultaneously can set and cancel the “LOCK” function ( )
Clock set
Note: The distance between the signal transmission head and the receiver
hole should be up to 7m without obstacles. When an electronic-started type
fluorescent lamp or change-over wireless telephone is installed in the room,
the receiver is apt to be disturbed in receiving the signals, so the distance
to the indoor unit should be shorter. Full display or unclear display during
operation indicates the batteries have been used up. Please change the
batteries. If the remote controller can’t run normally during operation,
please remove the batteries and reload several minutes later
Hint: Remove the batteries in case the unit won’t be in usage for a long
period.
QUIET Operation
You can use this function when silence is needed for rest or reading.
Press once is displayed, and the Air Conditioner starts the QUIET function
operation. In QUIET operation mode, fan speed automatically takes low speed of
AUTO fan mode.
Press the QUIET button again, disappears, and the QUIET the operation
stops
COOL, HEAT and DRY Operation
Press the HEAT button on the remote control.
Press the DRY button on the remote control.
- In DRY mode, when room temperature becomes lower than temp. setting +2 ºC, unit will run intermittently at LOW speed regardless of FAN setting.
- The remote controller can memorize each operation status. When starting it next time, just press ON/ OFF button and unit will return to the previous status.
Press the FAN SPEED button. For each press, fan speed changes as follows:
Unit will run at the selected fan speed.
Press the COPILOT button. For each press, changes as follows:
People could choose the airflow to follow or avoid their movements
NOTE:
A sensor is used to detect changes in the infrared radiation emitted by human
bodies. In case of the following conditions, the detection may not be
accurate:
- High room temperature, where the ambient temperature is close to body temperature.
- People wear a lot or lie on their stomach or back.
- Frequent movements of pets, or frequent swings of curtains or other indoor objects due to the wind.
- The left and right deflectors deviate to right.
- The left and right ends of the indoor unit are installed too close to the wall.
- There is direct sunlight inside the room. The air conditioner operates in a room where the ambient temperature fluctuates sharply.
If a person is at the border of more than one area, the following air will be sent to these areas respeCtively or be swept automatically. The avoiding air will avoid these areas or be swept automatically.
COPILOT Operation
Human Sensing Function
1. “Follow” function: It can detect where a person is and adjust the swing
flap accordingly and send air to the location of this person. If it detects
people in two locations, the swing flap will blow alternatively between these
two locations and stay at each location for 15s. If the appliance detects
people in three or more locations, the left and right swing flaps will swing
automatically. “Avoid” function: When the appliance detects a person in a
location, it will adjust the swing flap to avoid such a location. If it
detects people in three or more locations, the left and right swing flaps will
swing automatically.
Note:
-
When there are people in several locations or a person frequently moves between several locations,if this person is in the in-between location or the crossing location, whether the appliance is in a “Follow” mode or an“Avoid” mode, the swing flap will swing automatically to send air to these locations.
-
Whether the setting is “Follow” or “Avoid”, it takes some time to adjust their direction after the appliance identifies the location of the people and the air direction will not change immediately.
-
If the actual airflow cannot reach (or avoid) the location where a person is due to such factors as fan speed setting, temperature setting, ambient temperature difference and
the layout of the room, pressing the left and right swing flaps can adjust the air direction and set the airflow direction manually. -
Setting the health airflow when the human sensing (including follow/avoid) function is enabled will force exit from the human sensing (including follow/avoid) function.
-
Upper and lower swing flaps are not operational when the human sensing (including follow/avoid) function is enabled.
-
When the human sensing function is enabled, if the appliance cannot detect people for a long time (at least 20 minutes), it will automatically enter the power-saving mode. In the power-saving mode, the operating frequency will be reduced and the fan speed set at low. Once a person is detected, the appliance will exit from the power-saving mode.
-
When the human sensing function is enabled, the appliance will have a real-time detection of human movements and adjust the frequency and fan speed according to the movements. In the heating mode, if the movements are frequent, the frequency and fan speed will lower down; when the movements become less, the frequency and fan speed will rise but cannot exceed the setting values set by the remote controller. The cooling mode is the opposite of the heating mode.
HEALTH AIRFLOW Operation
Press the button of health airflow again, both the inlet and outlet grills of
the air conditioner are opened, and the unit goes on working under the
condition before the setting of health airflow function. After stopping, the
outlet grille will close automatically.
Notice: Do not adjust the outlet grille by hand. Otherwise, the grille
will run incorrectly. If the grille does not move correctly, stop for a minute
and then start, adjusting by remote controller. Remote controller can memorize
each operation status. when starting it next time, just press ON/OFF button
and unit will run in previous status.
Note:
- After setting the health airflow function, the position of inlet and outlet grills is fixed.
- In heating, it is better to select the IT mode.
- In cooling, it is better to select the 7 mode.
- In cooling and dry, using the air conditioner for a long time under the high air humidity, a phenomenon falling drips of water occurs at the outlet grille.
- Select the appropriate fan direction according to the actual conditions.
SWING Operation
Left and right airflow direction
For each press of “ ” button, the remote controller displays as follows: remote controller:
Initial state
- When humidity is high, condensate water might occur at air outlet if all vertical louvers are adjusted to left or right.
- It is advisable not to keep the horizontal flap at the downward position for a long time in COOL or DRY mode, otherwise, condensate water might occur.
- As cold air flows downward in COOL mode, adjusting airflow horizontally will be much more helpful for a better air circulation
TIMER Operation
Set Clock correctly before starting Timer operation. You can let the unit start or stop automatically at set times, like before you wake up in the morning or get back from outside or after you fall asleep at night.
After setting the correct time, press APPLY button to confirm “nM” or “OFF” on
the remote controller stop flashing.
To cancel TIMER mode Just press the TIMER button several times until the TIMER
display disappears.
Comfortable SLEEP
Before going to bed, you can simply press the SLEEP button, and the unit will operate in SLEEP mode and bring you a sound sleep.
Operation Mode
1. In COOL, DRY mode
1 hour after SLEEP mode starts, temp. will become 1°C higher than temp.
setting. After another
1 hour, temp. rises by 1°C again. The unit will run for another 6 hours then
stop.
Temp. under sleep mode is higher than temp. setting so that room temperature
won’t be too low for sleep.after SLEEP mode ****
2. In HEAT mode
1 hour after SLEEP mode starts, temp will become 2°C lower than temp. setting.
After another 1 hour, temp decreased by 2°C again. After another 3 hours,
temp. rises by 1°C. The unit will run for another 3 hours and then stop.
Temp. under SLEEP mode is lower than temp. setting so that the room
temperature won’t be too high for sleep.
3. In SMART mode
The unit operates in the corresponding sleep mode, which is adapted to the
automatically selected operation mode.
4. When SLEEP mode is set to 8 hours the time can not be adjusted.
When the TIMER function is set, the SLEEP mode can’t be set up. After the
SLEEP mode is set up, if the user resets the TIMER function, the SLEEP mode
will be canceled; the machine will be in the state of timing-on, if the two
modes are set up at the same time, either of their operation time is ended
first, the unit will stop automatically, and the other mode will be canceled.
Power Failure Resume Function
If the unit is started for the first time, the compressor will not start
running unless 3 minutes have passed . When the power resumes after power
failure, the unit will run automatically, and 3 minutes later the compressor
starts running.
Note to the power failure resume:
press the sleep button ten times in five seconds and enter function after
hearing four sounds. And press the sleep button ten times within five seconds
and leave this function after hearing two sounds.
SMART Operation
(This function is unavailable on some models)
One press can provide a more comfortable room.
The Air Conditioning unit can read the indoor temperature and humidity and
make adjustments accordingly
- SMART FRESH
- SMART Defrost
- SMART FAN SPEED
- SMART FAN HEALTH
- SMART DRY
- SMART SOFT
- SMART Control temperature
Under the cooling, heating and dehumidifying mode, press the smart key to
enter the smart function. Under the smart running mode, the air conditioner
will automatically select between cooling, heating, dehumidifying or fan mode.
When the smart function is running, press the “cooling”, “heating” or “dry”
key to switch to that mode, and exit from the smart function.
ECO Operation
Automatic adjustment of the unit’s operation according to the environmental temperature, while operating with power saving
- The ECO function only works under undercooling, heating or dehumidifying mode. After the ECO function is set, press mute, sleep or smart key to exit the ECO function.
- After the ECO function is set, the air conditioner will automatically adjust the set temperature and automatically control the power of the unit.
- The ECO function is more effective after the air conditioning has been running for over 2 hours.
HEALTH Operation
The Ionizer generates ions in the air, and helps provide better air quality by killing bacteria and speeding up the dust sediment in the room.
Pressing the HEALTH button once, is displayed on the remote controller and the
ionizer operation starts
Pressing the HEALTH button again will deactivate the ionizer operation.
The ionizer function can operate only when the indoor fan is running
(available under any mode). When the fan in the indoor unit does not work, the
HEALTH icon appears, but the Ionizer does not operate until the fan starts
running.
****Remove the battery cover;
Load the batteries as illustrated. 2 R-03 batteries, resetting key (cylinder); Be sure that the loading is in line with the “+”/“-”;
Load the battery, then put on the cover again.
ON/OFF operation and test operation
ON/OFF Operation:
- Use this operation only when the remote controller is defective or lost. For the Emergency Operation, use only for a limited time.
- When the emergency operation switch is pressed, a sound is heard once, which means the start of this
- When power switch is turning on for the first time and emergency operation starts, the unit will run automatically in the following mode:
Room
temperature| Designated
temperature| Timer
mode| Fan
speed| Operation
mode
---|---|---|---|---
Above 24 °C| 24 °C| No| AUTO| COOL
Below 24 °C| 24 °C| No| AUTO| HEAT
- It is impossible to change the settings of temp. and fan speed, It is also not possible to operate in timer or dry mode
Test operation:
The test operation switch is the same as an emergency switch.
- Use this switch in the test operation when the room temperature is below 16 °C, do not use it in the normal
- Continue to press the test operation switch for more than 5 seconds. After you hear a beep sound twice, release your finger from the switch: the cooling operation starts with the airflow speed “1-11”.
UV-C Lamp
- This appliance contains a UV-C lamp. l Refer to the maintenance instructions prior to opening the appliance.
- Eye or skin irritation may result from direct exposure to the UV-C lamp, do not look and/or touch the UV-C lamp directly. Be certain that there is no power supply to the unit before removing the air filter and/or installing it for cleaning and/or maintenance.
- UV-C barriers with the ultraviolet radiation hazard symbol should not be removed.
- Appliances that have any signs of damage should not be operated.
- Do not operate UV-C lamps outside of this appliance.
- The appliance must be disconnected from the power supply before replacing, cleaning or performing other maintenance of the UV-C lamp.
- Front panels bearing the ultraviolet radiation hazard symbol which have UV-C radiation are provided with a hall switch to interrupt the power to the UV-C lamps for your safety. Do not override the hall switch by magnet or other material.
- Prior to conducting user maintenance involving opening the front panels bearing the ultraviolet radiation hazard symbol, be certain that there is no power supply to the unit.
- If the UV-C lamp is damaged, it should only be replaced by the manufacturer, its service agent or similarly qualified persons, to avoid possible hazards.
- Unintended use of the appliance or damage to the housing may result in dangerous UV-C radiation. UV-C radiation may, even in small doses, cause harm to the eyes and skin.
UV Sterilization:
UV sterilization function uses the c-band of the UV spectrum which is
recommended for effective sterilization, in order to remove harmful
microorganisms such as bacteria in the air, providing you with healthy air.
Reminder:
- It is recommended to activate the UV sterilization function for 1-2 hours a day. The lifespan of the UV lamp is approximately 15000 hours of operation.
- Do not look directly at the UV lamp or come in contact with it when the sterilizing function is activated. Turn off the sterilizing function before opening the panel.
- A light-blue light may appear near the air conditioning inlet when the sterilizing function is on.
- The UV lamp will be activated when the health function is activated, and the indoor fan is operating.
56°C Sterilization
The 56°C Sterilization function can only be activated through the mobile
application Inventor Control.
When 56°C Sterilization function is activated, the air conditioner will
operate as below:
1st Stage: The air conditioner will start with the Self Clean function in
order to remove the dirt.
During the Self Clean function, the evaporator will operate under cooling
mode, freezing the evaporator of the indoor unit, then operate under heating
mode to melt the frost and remove the dust and dirt that has accumulated on
the evaporator. The unit will proceed with operation under fan mode to quickly
dry the evaporator. The hydrophilic aluminum coating with small angle (α≈5°)
increases the water drainage efficiency.
2nd Stage: Through smart temperature monitoring and frequency control
technology, the unit will enter the 56°C Sterilization phase, maintaining the
evaporator’s high temperature for over 30m in order to exterminate possible
bacteria and viruses inside the air conditioner. 3rd Stage: The air
conditioner will enter a rapid cooling process to enhance the sterilization
performance. The evaporator surface is coated with silver nanoparticles whose
anti-bacterial efficiency is up to 99%.
Important Notice:
The 56°C Sterilization function
- lasts approximately 60-80 minutes. Hot air may come out during this function.
- may result in the changes of room air temperature. This is normal.
When outdoor ambient temperature is above 36°C, only the 1st Stage (Self Clean function) will be activated.
Pair the Air Conditioner
with the Inventor Control application
Before you start:
-
Verify that the router is broadcasting at 2.4GHz.
-
If the router has dual band broadcasting, verify that the network names (SSIDs) are different.
For additional help, contact your router/internet provider. -
Verify that the Wi-Fi password is WPA2-PSK encrypted, and the authorization type is set to AES.
-
Make sure that the router is close to the air conditioner for unhindered pairing prossess and wireless operation.
Step 1: Download and install the “Inventor Control” application from the Google Play Store or IOS App Store.
Step 2: Select “Register” to create a new account or “Log in with Existing
Account”
Notes:
Carefully read the Privacy Policy and select “Agree” to continue.
To create an account, an email or a mobile number are required. Enter the code
that you received in your registered email or phone number, in the “Enter
Verification Code” field to proceed with the pairing process.
Step 3: To add the device, select “My appliances” and press “+” on the top right corner, or “Add Device”. Select on the left side the “Air Conditioner” option, and select the model of the air conditioner you want to pair.
Step 4: Select the Wi-Fi Network and enter the password. Press Confirm to
proceed. The pairing process may take some time.
Note: The pairing indication on the display of the air conditioner, may
disappear during this step.
Step 5: Plug in the air conditioner to the power supply and turn it on. Set
theair conditioner to Cooling Mode, Low Fan Speed and 30°C Temperature. The
indication on the display of the air conditioner will start blinking. Press
Confirm to proceed.
Step 6: Press “Go to Connect” to enter your mobile device settings. Connect to
the WiFi with name (SSID) “U-AC-XXXX”. Return to Inventor Control once
connected.
Step 7: Press “Confirm hot spot connection, next” as marked in the image above to start the pairing process.
Troubleshooting:
If the pairing process is not successful:
- Verify that the router is broadcasting at 2.4GHz.
- If the router has dual-band broadcasting, verify that the network names (SSIDs) are different. For additional help, contact your router/internet provider.
- Verify that the Wi-Fi password is WPA2-PSK encrypted, and the authorization type is set to AES.
- Make sure that the router is within the WLAN range of the air conditioner and no repeaters are installed.
- Power off the router, the air conditioner, and the device (tablet or mobile) and allow 5 minutes.
- Restart the pairing process from Step 2.
- If the pairing is not successful, repeat the process with a different smart device (tablet or mobile).
- Contact Inventor’s After Sales Dept.
IMPORTANT INFORMATION REGARDING
THE REFRIGERANT USED
This product contains fluorinated greenhouse gases covered by the Kyoto Protocol. Do not vent into the atmosphere. Refrigerant type: R32 GWP* value:675 GWP=global warming potential Please fill in with indelible ink,
- 1 the factory refrigerant charge of the product
- 2 the additional refrigerant amount charged in the field and
- 1+2 the total refrigerant charge on the refrigerant charge label supplied with the product. The filled-out label must adhere in the proximity of the product charging port (e.g. onto the inside of the stop value cover). A contains fluorinated greenhouse gases covered by the Kyoto Protocol B factory refrigerant charge of the product: see unit nameplate C additional refrigerant amount charged in the field D total refrigerant charge E outdoor unit F refrigerant cylinder and manifold for charging
EUROPEAN REGULATIONS
CONFORMITY FOR THE MODELS
Climate:T1
Voltage:230V
CE
All the products are in conformity with the following
European provision:
– 2014/53/EU(RED)
– 2014/517/EU(F-GAS)
– 2009/125/EC(ENERGY)
– 2010/30/EU(ENERGY)
– 2006/1907/EC(REACH)
ROHS
The products are fulfilled with the requirements in the directive 2011/65/EU
of the European Parliament and of the council on the Restriction of the use of
Certain Hazardous
Substances in Electrical and Electronic Equipment (EU RoHS Directive) WEEE
In accordance with the directive of the European
parliament, herewith we inform the consumer about the disposal requirements of
the electrical and electronic products.
DISPOSAL REQUIREMENTS:
Your air conditioning product is marked with this symbol. This means that electrical and electronic products shall not be mixed with unsorted household waste. Do not try to dismantle the system yourself: the dismantling of the air conditioning system, treatment of the refrigerant, of oil and of another part must be done by a qualified installer in accordance with relevant local and national legislation. Air conditioners must be treated at a specialized treatment facility for reuse, recycling and recovery. By ensuring this product is disposed of correctly, you will help to prevent potential negative consequences for the environment and human health. Please contact the installer or local authority for more information. The battery must be removed from the remote controller and disposed of separately in accordance with relevant local and national legislation.
WIFI
-Wireless maximum transmit power (20dBm)
-Wireless operating frequency range (2400~2483.5MHz)
Indoor Unit Installation
Necessary Tools for Installation
- Driver
- Nipper
- Hacksaw
- Hole core drill
- Spanner(17,19 and 26mm)
- Gas leakage detector or
- soap-and-water solution
- Torque wrench 17mm,22mm,26mm)
- Pipe cutter
- Flaring tool
- Knife
- Measuring tape
- Reamer
Selection of Installation Place
- Place, robust not causing vibration, where the body can be supported sufficiently.
- Place, not affected by heat or steam generated in the vicinity, where the inlet and outlet of the unit are not disturbed.
- Place, possible to drain easily, where piping can be connected with the outdoor unit.
- Place, where cold air can be spread in a room entirely.
- Place, nearby a power receptacle, with enough space around.
- Place where the distance of more than Im from televisions, radios, wireless apparatuses and fluorescent lamps can be left.
- In the case of fixing the remote controller on a wall, place where the indoor unit can receive signals when the fluorescent lamps in the room are lightened.
Power Source
- Before inserting power into receptacle, check the voltage without fail.
- The power supply is the same as the corresponding nameplate.
- Install an exclusive branch circuit of the power.
- A receptacle shall be set up in a distance where the power cable can be reached.Do not extend the cable by cutting it.
Selection of Pipe
FOR 09K 12K | Liquid pipe | 4, 6.35×0.8mm |
---|---|---|
Gas pipe | cp9.52×0.8mm | |
FOR 18K | Liquid pipe | (1) 6.35×0.8mm |
Gas pipe | it. 12.7×0.8mm | |
FOR 24K | Liquid pipe | (1) 9.52×0.8mm |
Gas pipe | 1 15.88×1.0mm |
Drawing for the installation of indoor units
The models adopt HFC free refrigerant R32
If using the left side drain pipe, make sure the hole is got through.
The distance between the indoor unit and the floor should be more than 2m.
Please be subject to the actual product purchased,the above picture is just
for your reference.
Indoor Unit Installation
Fitting of the Mounting Plate and Positioning of the wall Hole When the mounting plate is first fixed
- Carry out, based on the neighboring pillars or lintels, a to be fixed against the wall, then temporarily fasten the plate proper leveling for the plate with one steel nail.
- Make sure once more the proper level of the plate, by hanging a thread with a weight from the central top of the plate, then fasten securely the plate with the attachment steel nail.
- Find the wall hole location A/C using a measuring tape
When the mounting plate is fixed sidebar and lintel
- Fix to sidebar and lintel a mounting bar, Which is separately sold, and then fasten the plate to the fixed mounting bar.
- Refer to the previous article, ” When the mounting plate is first fixed “, for the position of the wall hole.
Making a Hole on the Wall and Fitting the Piping Hole Cover
- Make a hole of 60 mm in diameter, slightly descending to outside the wall
- Install piping hole cover and seal it off with putty after installation
Installation of the Indoor Unit
Drawing of pipe
[ Rear piping ]
- Draw pipes and the drain hose, then fasten them with the adhesive tape
- [ Left Left-rear piping ]
- In case of left side piping, cutaway, with a nipper, the lid for left piping.
In the case of left-rear piping, bend the pipes according to the piping direction to the mark of the hole for left-rear piping which is marked on heat insulation materials.
1. Insert the drain hose into the dent of heat insulation materials of the indoor unit.
2. Insert the indoor/outdoor electric cable from the backside of the indoor unit, and pull it out on the front side, then connect them.
3. Coat the flaring seal face with refrigerant oil and connect pipes. Cover the connection part with heat insulation materials closely, and make sure fixing with adhesive tape
-
Indoor/outdoor electric cable and drain hose must be bound with refrigerant piping by protecting tape.
[ Other direction piping ] -
Cut away, with a nipper, the lid for piping according to the piping direction, and then bend the pipe according to the position of the wall hole. When bending, be careful not to crash pipes.
-
Connect beforehand the indoor/outdoor electric cable, and then pull out the connection to the heat insulation of connecting part especially.
Fixing the indoor unit body
- Hang surely the unit body onto the upper notches of the mounting plate. Move the body from side to side to verify its secure fixing.
- In order to fix the body onto the mounting plate,hold up the body aslant from the underside and then put it down perpendicularly. ****
Unloading of indoor unit body
- When you unload the indoor unit,please use your hand to arise the body to leave agraffe,then lift the bottom of the body outward slightly and lift the unit aslant until it leaves the mounting plate.
Connecting the indoor/outdoor Electric Cable
Removing the wiring cover
Remove the terminal cover at right bottom corner of the indoor unit, then take off wiring cover by removing its screws.
When connecting the cable after installing the indoor unit
- Insert from outside the room cable into left side of the wall hole, in which the pipe has already existed.
- Pull out the cable on the front side, and connect the cable making a loop.
When connecting the cable before installing the indoor unit
- Insert the cable from the backside of the unit, then pull it out on the front side.
- Loosen the screws and insert the cable ends fully into the terminal block, then tighten the screws.
- Pull the cable slightly to make sure the cables have been properly inserted and tightened.
- After the cable connection, never fail to fasten the connection cable with the wiring cover.
Note: When connecting the cable, confirm the terminal number of indoor
and outdoor units carefully. If wiring is not correct, proper operation can
not be carried out and will cause a defect.
Connecting wiring: 4G1.0mm 2
- If the supply cord is damaged, it must be replaced by the manufacturer or its service agent or a similarly qualified person. The type of connecting wire is HO5RN-F or HO7RN-F.
- If the fuse on the PC board is broken please change it with the type of T.
- 15A/250VAC (Indoor). 3. The wiring method should be in line with the local wiring standard.
- After installation, the power plug should be easily reached.
- A breaker should be incorporated into fixed wiring. The breaker should be all-pole switch and the distance between its two contacts should be not less than 3mm.
0 Power Source Installation
- The power source must be exclusively used for air conditioner.
- In the case of installing an air conditioner in a moist place, please instal an earth leakage breaker.
- For installation in other places, use a circuit breaker as far as possible.
Cutting and Flaring Work of Piping
- Pipe cutting is carried out with a pipe cutter and burs must be removed.
- After inserting the flare nut, flaring work is carried out.
| Flare tool for R410A| Conventional flare tool
---|---|---
Clutch-type| clutch-type(Rigid-type)| Wing-nut type (Imperial-type)
<A| 0-0.5mm| 1.0-1.5mm| 1.5-2.0mm
On Drainage
Please install the drain hose so as to be downward slope without fail.
Please don’t do the drainage as shown below.
- Please pour water in the drain pan of the indoor unit, and is carried out surely to outdoor.
- In case the attached drain hose is in a room, please apply heat insulation to drainage it without fail.
On Drainage
Code indication | Trouble description | Analyze and diagnose |
---|---|---|
El | Room temperature sensor failure | Faulty connector connection; Faulty |
thermistor;
Faulty PCB;
E2| Heat-exchange sensor failure
E4| Indoor EEPROM error| Faulty EEPROM data; Faulty EEPROM;
Faulty PCB;
E7| Communication
fault between indoor and outdoor units
| Indoor unit- outdoor unit signal transmission error due to wiring error;
Faulty PCB;
E14| Indoor fan motor malfunction| Operation halt due to breaking of wire inside the fan motor; Operation halt due to breaking of the fan motor lead wires; Detection error due to faulty indoor unit PCB;
9 Check for Installation and Test Run
■ Please kindly explain to our customers how to operate through the
instruction manual.
Check Items for Test Run
Put checkmark V inboxes
- Gas leak from the pipe connecting?
- Heat insulation of pipe connecting?
- Are the connecting wirings of indoor and outdoor firmly inserted to the terminal block?
- Is the connecting wiring of indoor and outdoor firmly fixed?
- Is drainage securely carried out?
- Is the earth line securely connected?
- Is the indoor unit securely fixed?
- Is the power source voltage abided by the code?
- Is there any noise?
- Is the lamp normally lit?
- Are cooling and heating (when in heat pump)
- performed normally?
- Ils the operation of room temperature regulator normal?
Maintenance
For Smart Use of The Air Conditioner
Remote Controller
Do not use water,wipe the controller with a dry cloth.Do not use glass cleaner or chemical cloth.
Indoor Body
wipe the air conditioner by using a soft and dry cloth.For serious stains, use a neutral detergent diluted with water.Wring the water out of the cloth before wiping,then wipe off the detergent completely.
Air Filter cleaning
- Press the “SMART” button for 5s to partially raise the panel.
- Open the panel by hand and support the panel with a holder
- Remove the filter
- Clean the filter
- Fit the filter
- Remove the holder and close the panel
- Long press the “SMART” button and the panel will automatically lower down and become closed
Replacement of Air Purifying Filter
-
.Open the lnlet Grille Press the “SMART” button for 5s to partially raise the panel.
-
Detach the standard air filter Slide the knob slightly upward to release the filter, then withdraw it.
-
Attach Air Purifying Filter
Put air purifying filter appliances into the right and left filter frames. -
Attach the standard air filter
(Necessary installation)
ATTENTION:
The white side of the photocatalyst air purifying filter face outside,and the
black side face the unit The green side of the bacteria-killing medium air
purifying filter face
outside, and the white side face the unit.
- Close the Inlet Grille
Long press the “START” button and the panel will automatically lower down and become closed.
NOTE:
The photocatalyst air purifying filter will be solarized in a fixed time. In a
normal family, it will be solarized every 6 months.
The bacteria-killing medium air purifying filter will be used for a long
time,no need for replacement. But in the period of using them,you should
remove the dust frequently by using a vacuum cleaner or flapping them lightly,
otherwise, its performance will be affected.
Please keep the bacteria-killing medium air purifying filter in avoiding a
long time of directly sunshine
when you stop using it,or its ability of sterilization will be the cool and
dry conditions reduced.
Cautions
WARNING
Please call Sales/Service Shop for the Installation.
Do not attempt to install the air conditioner by yourself because improper
works may cause electric shock, fire, water leakage.
Troubleshooting
Before asking for service, check the following first.
| Phenomenon| Cause or checkpoints
---|---|---
Normal Performance inspection| The system does not restart immediately.
| · When unit is stopped, it won’t restart immediately until 3 minutes
have elapsed to protect the system. · When the electric plug is pulled out
and reinserted, the protection circuit will work for 3 minutes to protect the
air conditioner.
Noise is heard| · During unit operation or at stop, a swishing or gurgling
noise may be heard.At first 2-3 minutes after unit start, this noise is more
noticeable. (This noise is generated by refrigerant flowing in the system.) ·
Dunng unit operation, a cracking noise may be heard.This noise is generated by
the casing expanding or shrinking because of temperature changes. · Should
there be a big noise from air flow in unit operation, air filter may be too
dirty.
Smells are
generated.| · This is because the system circulates smells from the interior
air such as the smell of furniture, paint. cigarettes.
Mist or steam are blown out.| · During COOL or DRY operation, indoor unit
may blow out mist. This is due to the sudden cooling of indoor air.
In dry mode,fan speed can’t be changed.| · In DRY mode, when room
temperature becomes lower than temp. setting+2 °C,unit will run intermittently
at LOW speed regardless of the FAN setting.
Multiple
check| | · Is the power plug inserted?
· Is there a power failure?
· Is fuse blown out?
Poor cooling
| · Is the air filter dirty?
Normally it should be cleaned every 15 days.
· Are there any obstacles before the inlet and outlet?
· Is the temperature set correctly?
·Are there some doors or
windows left open?
· Is there any direct sunlight through the window during the cooling
operation?(Use curtain)
·Are there too many heat sources or too many people in the room during cooling
operation? -I
Cautions
- Do not obstruct or cover the ventilation conditioner.Do not put fingers inlet/outlet and swing louver. grille of the air or any other things into the
- This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not
play with the appliance.
Specifications
The refrigerating circuit is leak-proof.
The machine is adaptive in the following situation
- Applicable ambient temperature range:
Cooling| Indoor| Maximum:D.B/W.B 35°C/24°C
Minimum:D.BNV.B 21°C/15°C
---|---|---
Outdoor| Maximum:D.B/W.B 43°C/26°C Minimum: D.B -20°C
Heating| Indoor| Maximum:D.B 27°C
Minimum: D.B 10°C
Outdoor| Maximum:D.B/W.B 24°C/18°C Minimum:D.B -15°C
Outdoor
(INVERTER)
| Maximum:D.B/W.B 24°C/18°C Minimum:D.B -20°C
2. If the power supply cord is damaged, it must be replaced manufacturer by a qualified person.
3. If the fuse of the indoor unit on PC board is it with the type of T. 3.15A/ 250V outdoor or its service agent or a similar broken,please. If the fuse of change unit is
broken, change it with the type of T.25A/250V
- The wiring method should be in line with the local wiring
- After installation, the power plug should be easily reached.
- The waste battery should be disposed of properly.
- The appliance is not intended for use by persons without supervision.
- Young children should be supervised with the appliance.
- Please employ the proper power plug, and cord. standard. by young children or infirm to ensure that they do not play which fit into the power supply The power plug and connecting cable
- must have acquired the local
- n order to protect the units, please turn off the A/C first, attestation. and at least 30 seconds later, cutting off the power.
All the pictures in the manual are for explanatory purposes only. The actual
shape of the unit you purchased may be slightly different, but the operations
and functions are the same. The company may not be held responsible for any
misprinted information. The design and the specifications of the product for
reasons, such as product improvement, are subject to change without any prior
notice.
Please consult with the manufacturer at +30 211 300 3300 or with the Local
Distributor for further details.
Scan here to download the latest version of this manual.
www.inventorairconditioner.com/media- library
Activate your Warranty
Follow the next quick steps to activate your warranty:
STEP 1 Visit our website via the link:
https://www.inventorairconditioner.com/warranty-inventor
or by scanning the QR code, as follows:
https://www.inventorairconditioner.com/media-library
AIR CONDITIONING SYSTEMS
WALL MOUNTED UNIT
V:1.1 082021 ****
Documents / Resources
|
inventer MFVI32-09WFI Air Conditioning
System
[pdf] User Manual
MFVI32-09WFI, Air Conditioning System, MFVI32-09WFI Air Conditioning System,
Conditioning System
---|---
References
- heard.at is available for purchase - Sedo.com
- Biblioteca media - Inventor
- Media Library & Support - Inventor
- 10 χρόνια εγγύηση κλιματιστικών Inventor - Inventor
- Inventor
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>