inVENTer 3002-0270 Pulsar Basic Exhaust Fan Instruction Manual
- June 3, 2024
- inVENTer
Table of Contents
- 3002-0270 Pulsar Basic Exhaust Fan
- Disclaimer
- Company Information
- User and Safety instructions
- Intented use
- SYSTEM OVERVIEW
- Preparing for installation
- Electrical connection
- Installation
- Cleaning and care
- Technical Data
- Scope of supply
- Accesories
- Service
- Disposal
- Warranty and guarantee
- Documents / Resources
3002-0270 Pulsar Basic Exhaust Fan
Instruction Manual
3002-0270 Pulsar Basic Exhaust Fan
Trademarks, copyrights and industrial property rights
inVENTer® is a protected trademark of inVENTer GmbH.
The copyright to this document remains with the manufacturer.
Rights to all content and images:
©inVENTer GmbH 2022.
All trademarks used in this document are the property of
their respective manufacturers and are hereby acknowledged.
Disclaimer
This documentation represents a translation of the original German
installation and operating instructions. It must be passed on to the user
(tenant, owner, property management, etc.) after completion of the
installation.
The contents of this documentation have been checked for conformity with the
hardware and software described.
Nevertheless, deviations cannot be excluded, so that no guarantee can be given
for complete conformity.
This documentation describes the functionality of the standard range. For
reasons of clarity, the documentation does not contain all detailed
information on all types of the
product and cannot take into account every conceivable case of operation,
cleaning and maintenance.
The illustrations in this documentation may differ slightly from the design of
the product you have purchased. The function remains the same despite the
difference in detail.
This documentation is updated regularly. Necessary corrections and appropriate
supplements are always included in subsequent editions.
You can also find the latest version at:
www.inventer.eu/downloads.
Company Information
Publisher:
inVENTer GmbH
Ortsstraße 4a
D-07751 Löberschütz
Germany Web:| Telefon: +49 (0) 36427 211-0
Fax: +49 (0) 36427 211-113
E-Mail: info@inventer.de
www.inventer.eu
---|---
CEO: Annett Wettig
VAT ID number: DE 815494982
Jena District Court HRB 510380
User and Safety instructions
Thank you for purchasing this high quality product from inVENTer!
This section provides an overview of the basic safety precautions for safe and
proper operation of your ventilation system.
1.1 User information
Safety and warning instructions
The safety and warning instructions in these installation instructions have a
uniform structure and are marked with a symbol on the left side of the
instruction. The color of the symbol indicates the hazard level. A signalword
in front of the text also indicates the hazard level. If several hazard levels
occur, the safety note for the highest level is always used.
SIGNAL WORD
Type and origin of the hazard.
Possible consequences of the danger!
- Measures to avoid hazard.
The signal word indicates the severity of the potential hazard unless the
preventive measures are taken:
DANGER means: Imminent danger of serious injury or death.
Warning means: Possible danger of serious injury or death.
CAUTION means: Direct danger or minor/signifi- cant injury.
NOTICE means: Direct or possible risk of property damage due to an
adverse event/state.
Other symbols used in this documentation
A TIPsymbol indicates practical and useful tips for handing your exhaust fan.
Additional tools are required to perform task
► Action required: This prompts the user to perform a specific action.
Check results: Requires user to check results of the action performed.
All graphics represent the interior wall.
1.2 Safety instructions
**** The operating instructions are part of your ventilation unit and must
be available at all times (see
www.inventer.eu/downloads). When the
unit/system is handed over to a third party, the installation and operating
instructions must also be handed over. Before carrying out any work on the
system, read this documentation carefully and observe all the instructions for
installation, commissioning and maintenance given in this chapter. In
addition, observe the safety instructions that precede the instructions
described. Failure to observe the safety instructions may result in personal
injury and/or damage to property.
Intented use
The Pulsar Basic exhaust air fan (hereinafter referred to as “Pulsar Basic”)
is used for ventilating rooms with external windows, taking into account the
technical data specified in this manual, described applications and only in
conjunction with the components recommended and approved by inVENTer GmbH and
specified in this documentation. Modifications or conversions to the device
are not permitted.
The Pulsar Basic complies with the technical safety requirements and standards
of electrical appliances for domestic use. It may only be set up and operated
in conjunction with this documentation.
Faultless and safe operation of the device requires proper operation and
maintenance.
- Observe the applicable standards, regulations and directives when carrying out work.
- The Pulsar Basic is designed for permanent installation with permanent wiring.
- DANGER: The device may only be installed by qualified personel.
- Observe the specifications of protection class II when laying the power supply cable.
- Run all devices of a ventilation system on the same circuit breaker.
- Lay and connect the cable only when it is disconnect ed from the power supply!
- It must be ensured that the mains power supply (voltage, frequency) corresponds to the specifications on the type plate.
- Before working on electrical equipment, disconnect all affected equipment from the power supply (switch at the bottom left of the control unit).
- Before drilling, check whether there are any lines in the drilling area.
- DANGER: Observe the installation regulations according to VDE 0100 when connecting in damp areas.
- Mount Pulsar Basic exclusively outside Protected area 0. ( ****Chapter 3.1, page 8).
- Do not use the Pulsar Basic in locations where direct contact with splash water is possible over a long period of time and/or the device is exposed to direct jets of water.
- WARNING: For the joint operation of a ventilation unit with fireplaces, securing measures must be taken to prevent the occurrence of negative pressure in the building. The decision as to which measures should be carried out is made by the responsible chimney sweep and/or building planner.
- CAUTION: The Pulsar Basic must not be operated and cleaned by children and/or persons who, due to their physical, sensory or mental capabilities, inexperience or lack of knowledge, are not safely able to do so, unless they are supervised by a person responsible for their safety or have been instructed by him/her on how to operate the ventilation unit. Small children must be supervised so that they do not play with the device.
- NOTICE The use of a too small cable cross-section leads to a too high voltage drop and/or the contacting is not guaranteed!
- NOTICE Ensure sufficient contacting of the lines when connecting the Pulsar Basic.
- NOTICE Laying cables whose sheathing under plaster is not plaster-resistant leads to short circuits and cable fires! Lay cables without a plaster-resistant cable sheath in the empty conduit.
- NOTICE The device has plastic surfaces that are sensitive to scratches. Do not touch components with oily and/or dirty hands. Avoid contact with sharp or pointed objects.
- Ensure that there is sufficient air supply in the room.
SYSTEM OVERVIEW
- The exhaust fan must not be put into operation until the construction work has been completed.
Use contrary to the intended purpose leads to the exclusion of any liability
claims.
Improper use
Do not operate the equipment in areas where the following may enter or occur:
- Environment with high oil or grease content.
- Flammable gases, liquids or vapours.
- Enviroment temperatures outside 5 – 50 °C
- Possible obstacles to access the fan or the removal of the fan.
Qualified personnel
Mounting and electrical connection of the device may only be carried out by
qualified personnel.
Qualified personnel in the sense of the safety instructions in this
documentation are persons who are authorized to install, commission and label
devices, systems and circuits
in accordance with safety engineering standards.
Conformity
The Pulsar Basic meets the requirement for mechanical safety (DIN EN
60335-2-80).
The full text of the EU Declaration of Conformity is available at the
following Internet address: https://www.inventer.eu/downloads/
The Pulsar Basic is an innovative exhaust fan with a contemporary design. It
improves the basic ventilation in your rooms and enables continuous
ventilation to reduce humidity and odours in wet rooms (WC/bath/shower room/
laundryroom).
The Pulsar Basic can be used in conjunction with the aV100 wall mounting set,
or in another wall mounting sleeve with diameter 100… 140 mm can be installed
(check valve must be retrofitted on site in this case). Installation is
possible in ceilings and exterior walls. The Pulsar Basic allows connection
directly to the 230 V mains or via a power supply unit.
To ensure that the Pulsar Basic does not interfere with other ventilation and
that its function is not interfered with by other ventilation processes, it
must always be installed in its own wall sleeve. There must be no obstacles or
other objects in it that could interfere with the airflow. To avoid any
condensation that may occur in wall sleeves (in winter), they must be
insulated at the points where they pass through unheated areas, such as cold
attics.
Abbildung 1: Exhaust fan Pulsar Basic
2.1 Functions
Depending on the electrical connection, the Pulsar Basic can ventilate the
room either continuously (continuous ventilation at 30 m³/h and via sensors)
or on demand (exclusively via sensors, no continuous ventilation). The
integrated sensors enable the following functions:
-
Controlled by light incidence:
When the lighting conditions change, when light is switched on, the shadows change or when a person enters the room, the fan starts with an air flow rate of about 60 m³/h. The fan is then switched on again. In addition, a time overrun is activated. After being switched on, the Pulsar Basic continues to run until the end of the overrun time and then, depending on the connection, switches back to an air flow rate of 30 m³/h or off. The time lag is preset to 15 minutes and cannot be changed. -
Controlled by humidity sensor (automatic humidity monitoring):
If the humidity in the interior increases very sharply within a short period of time, for example when the shower is in use (peak humidity loads), the air flow rate rises to a maximum of 110 m³/h.
Preparing for installation
3.1 Installation conditions
Electrical protection areas according to VDE 0100
DANGER:
Ingress of water into the Pulsar Basic exhaust fan or its power source.
Electric shock and overheating due to short circuit (230V, 50 Hz)!
- Mount the Pulsar Basic outside the protected area 0.
- Only install the Pulsar Basic in areas of protection zone 1 in which no direct contact with splash water is possible over a longer period of time and/or the unit is not exposed to direct jets of water.
- Install light switches/switches/pushbuttons outside the protected area 0 to 2.
Abbildung 2: Overview electrical protection areas in the bathroom
Positioning of the Pulsar Basic
• Install the Pulsar Basic exhaust fan in the air volume flow of the room to ensure optimum humidity discharge and reliable readings from the humidity sensor.
Abbildung 3: Correct/Incorrect positioning
- Do not place the ventilation unit above radiators, room thermostats and/or sensitive furniture.
- Ensure that there is sufficient air supply in the room.
Cable cross sections
- Supply line, AC 230 V, 50 Hz: Cable cross-section 1.5 mm²
- Operating voltage to exhaust air unit, DC 12 V, Cable cross-section max. 1.5 mm²
- Capacity of connection terminals on exhaust air unit: max. 1.5 mm²
3.2 Dimensions
Keep a minimum distance of 250 mm from components at the front and all around.
Designation | Depth/ Lenght [mm] | Ø [mm] |
---|
Wall openings (drill holes):
Masonry (wall sleeve1)| Wall thickness| 115
Intermediate ceiling| Wall thickness| 105
Flush-mounting box power supply unit1)| 66| 68
Cavity wall box power supply unit1)| 61| 68
Mounting elements:
Exhaust fan Pulsar Basic| 81| 177
Wall mounting sleeve DN 1001)| Wall thickness| 100
Power supply unit1) (12V DC)| 32| 54
- aV100 wall mounting set (wall sleeve incl. weather protection hood), power supply unit and mounting boxes are available from inVENTer GmbH.
Electrical connection
The Pulsar Basic exhaust fan can be connected directly to the AC 230 V mains
or operated with protective extra-low voltage 12 V DC (SELV). A power supply
unit is optionally available.
NOTICE With simultaneous connection of 230 V AC and 12 V DC,
Damage to the Pulsar Basic exhaust fan!
- Never connect the Pulsar Basic exhaust fan to 230 V AC and 12 V DC at the same time.
NOTICE Laying the power supply cable over the cover of the circuit board will damage the circuit board and impair the function of the Pulsar Basic!
- Do not lay the AC 230 V mains connection cable over the circuit board.
3.3 Dimensional drawings
Abbildung 4: Positioning of the Pulsar Basic
4.1 Electrical connection 230 V AC (Alternating Current) Connection
terminal Mains connection cable
Terminal assignment
- Cable input Mains connection cable
- Cable bushing Mains connection cable
- Connection terminal Mains connection cable, 230 V AC, 3-pole
Abbildung 5: Circuit board – Connection terminal Mains connection cable
230 V AC
Wiring diagrams 230 V connection
The connection of the exhaust fan depends on the desired functions. Make sure
you connect the exhaust fan properly and select the correct presets for your
functions during start-up.
Sensor controlled functions
Sensor controlled, with continuous ventilation:
- Continuous ventilation with an air flow rate of 30 m³/h.
- Sensors are enabled.
- Increase fan power in case of increased humidity (110 m3 /h, no overrun) or under the influence of light changes (60 m3 /h, overrun).
Abbildung 6: Pulsar Basic 230 V AC with overrun function
Sensor controlled, with out continuous ventilation:
- Controlled ventilation required.
- Sensors are enabled.
- Increase fan power in case of increased humidity (110 m 3 /h, no overrun) or under the influence of light changes (60 m 3 /h, overrun).
Abbildung 7: Pulsar Basic 230 V AC without overrun function
Switch controlled functions
Sensor controlled, with additional external on/off switch:
- Controlled ventilation required.
- Sensors are enabled.
- Increase fan power in case of increased humidity (110 m 3 /h, no overrun) or under the influence of light changes (60 m 3 /h, overrun).
- It is possible to switch the Pulsar Basic on or off manually at the external switch S. The external switching element must have an NC contact.
Abbildung 8: Pulsar Basic 230 V AC with external swichting element S (NC
contact)
4.2 Electrical connection 12 V DC (Direct current)
Connection terminal Operating voltage
Terminal assignment
Abbildung 9: Circuit board – Connection terminal 12 V DC
- Cable input Connection cable
- Cable bushing Mains connection cable
- Connection cable, 12 V DC, 2-wire
- Terminal connecting cable
- Circuit board
Wiring diagrams 12 V connection
The connection of the exhaust fan depends on the desired functions. Make sure
you connect the exhaust fan properly and select the correct presets for your
functions during start-up.
The switch S1 integrated on the exhaust air fan Pulsar Basic has no function
when connecting 12 V DC.
Functions
Sensor controlled, with continuous ventilation (Fig. 10):
- Continuous ventilation with an air flow rate of 30 m³/h.
- Increase fan power in case of increased humidity (110 m³/h, no overrun) or under the influence of light changes (60 m³/h, overrun).
optional: with additional external on/off switch (Fig. 11)
- The exhaust fan is switched on and off via a manual, external switch S.
- For further functions see description on the left (sen- sor-controlled, with continuous ventilation)
Abbildung 10: Wiring diagram Flush-mounted power supply unit NT16 and exhaust fan Pulsar Basic 12 V DC (sensor-controlled)
Abbildung 11: Wiring diagram Flush-mounted power supply unit NT16 and exhaust fan Pulsar Basic 12 V DC (with optional external switching element)
Installation
DANGER:
Exposed electrical components.
Electric shock and overheating due to short circuit (230V, 50 Hz)!
- Connection exclusively by qualified personnel.
- Observe the safety rules for preventing electrical accidents before and during installation.
DANGER:
Ingress of water into the Pulsar Basic exhaust fan or its power source.
Electric shock and overheating due to short circuit (230V, 50 Hz)!
- Mount the Pulsar Basic outside the protected area 0.
- Only install the Pulsar Basic in areas of protection zone 1 in which no direct contact with splash water is possible over a longer period of time and/or the unit is not exposed to direct jets of water.
- Install light switches/switches/pushbuttons outside the protected area 0 to 2.
5.1 Mounting the wall sleeve and Laying the lines
Milling drill ø 115 mm, wall mounting sleeve (e.g. aV100 wall mounting set)
Prerequisites:
- The masonry is dry and load-bearing.
- There are no load-bearing elements in the position of the planned drill hole/plaster or masonry slot.
► Create a Wall opening, Ø 115 mm, at the mounting location of the Pulsar
Basic.
► Mill the plaster/wall slot between power source/switch and mounting location
of the Pulsar Basic.
For options for positioning the cable bushing, see Figure 12.The cable bushing
should be located near the respective connection terminal.
NOTICE Accumulation of condensation water in the wall mounting sleeve
leads to damage to the outer wall and masonry!
- Insert wall sleeve with a slope of 1 – 2° to the outer wall.
► Install the aV100 wall mounting set ( Installation instructions aV100 wall
mounting set). OR
► Place a wall mounting sleeve DN100 in the wall opening.
- The wall sleeve does not end flush with the plaster on the inside wall. It is installed with a distance of 5 mm to the inside (into the wall).
- An appropriate non-return valve must be provided and installed by the customer.
The aV100 wall installation set (wall installation sleeve incl. non-return damper and external termination), which serves as a receptacle for the Pulsar Basic exhaust air fan, is optionally available from inVENTer GmbH.
Laying cables
► Lay the mains connection cable, 3-wire:
- from the control panel to the installation location of the Pulsar Basic, or.
- in between the external switch/button and the installation place of the Pulsar Basic.
The cable end protrudes approx. 300 mm from the wall.
► Install the power supply unit ( ****5.2, optional)
The wall mouting set is installed
5.2 Mounting the power supply unit (optional)
The installation of the additional power supply unit is ca- rried out only
with the 12 V DC electrical connection. A power supply unit and a mounting box
can be ordered as
optional accessories.
Milling drill ø 68 mm, connecting clamps, filling material for plastering in
the box
► Create a wall opening for the mounting box at the power supply mounting
location.
► Lay the required cables to connect the power supply unit to the mounting
location:
- Supply line between control cabinet and mounting location power supply unit: AC 230 V, 50 Hz:
- Operating voltage to the exhaust air unit: DC 12 V
► Lay the cables at the mounting location of the power supply unit in the
mounting box.
► Install the mounting box in the inside wall.
5.3 Inserting and connecting the Pulsar Basic
Screwdriver, drill, dowels, screws, spirit level, stripping tool
Requirements:
- The wall mouting set is installed. Styrofoam panes have been removed.
- The connection cable (AC 230 V, 50 Hz/ DC 12 V) has been laid.
► Reach behind the fan unit with both hands.
► Pull the fan unit forward off the fan housing.
Hold the fan unit firmily so tha it does not fall to the floor when removed.
► Use a screwdriver to press in the locking button (red arrow) on the fan
housing.
► Loosen the cover of the fan housing.
► Lift the cover of the fan housing from the top to the front.
► Fit the rubber seal (from the accesory pack) to the back of the fan housing.
First carefully place the switch (red arrow) in the opening provided.
► Press the rubber seal firmly onto the base plate of the fan housing.
Press firmly on the side of the integrated switch beginning and end on the
opposite side.
► Create a lead-through for the connection cable in the rubber seal at one of
the 5 cable inlets using a suitable tool.
Near the respective connection terminal.
► Insert the fan housing into the wall sleeve from the inside.
The lettering “TOP” is directed upwards.
► Aling the fan housing straight using a spirit level. To do this, place the
spirit level at the support points of the fan housing (red arrows).
► Mark the 3 fixing holes (blue areas)
► Remove the housing from the wall sleeve again and drill the holes.
► Lead the connection cable, AC 230 V, 50 Hz or DC 12 V, through the cable gland created in the rubber seal.
► Place the base plate, including the rubber seal, congruent with the fixing
holes in the wall sleeve.
The lettering “TOP” is legible and directed upwards.
► Screw the base plate of the fan housing to the inner wall.
The rubber seal completely seals the exhaust fan to the inner wall.
NOTICE Laying the power supply cable over the cover of the circuit board
will damage the circuit board and impair the function of the Pulsar Basic!
- Do not lay the AC 230 V mains connection cable over the circuit board.
NOTICE Simultaneous connection of AC 230V and DC 12 V will damage the Pulsar Basic!
- The Pulsar Basic cannot be connected to AC 230 V and DC 12 V simultaneously.
► Shorten the connection cable so that you can reach the connection terminal
(red arrows).
AC 230 V: 3-pole Connection terminal.
DC 12 V: 2-pole Connection terminal.
Route the connection cable through the cable gland in the upper area to ensure
the correct installation of the fan unit.
► Attach the shortened connection cable, according to the connection diagram,
in the connection terminal of the base plate.
****4: Terminal assignment, connection diagrams.
Exhaust fan Pulsar Basic is inserted and connected.
► Engage the hook on the lower side of the base plate in the hole (red arrow)
on the lower side of the fan housing cover.
The guides for the fan unit are located in the upper area.
► Press the cover of the fan housing in the upper area onto the holder (green
arrow) on the base plate of the fan housing.
The locking button (red arrow) audibly engages between the guides for the fan
unit.
► Carefully place the fan unit into the guides (red arrow) of the fan housing.
Do not tilt the fan when inserting it so as not to damage the contacts.
An audible click confirms that the fan unit is correctly inserted.
► Make sure that the fan is able to roate freely once switched on.
► Switch on the power supply.
- DC 12 V: When the power supply is switched on, the fan runs (with switch control, the external switch is used to switch on and off).
- AC 230 V: Switch the Pulsar Basic on. The switch is located in the left side of the fan housing. Push it to position 1.
Cleaning and care
CAUTION: Rotating parts on the fan lead to injuries.
- Before working on electrical equipment, disconnect all affected equipment from the power supply (switch at the bottom left of the control unit).
CAUTION:
Cleaning by children and persons with limited abilities may result in injury
to parts of the body and/or malfunction of the ventilation system!
- The Pulsar Basic must not be operated and cleaned by children and/or persons who, due to their physical, sensory or mental capabilities, inexperience or lack of knowledge, are not safely able to do so, unless they are supervised by a person responsible for their safety or have been instructed by him/her on how to operate the ventilation unit.
The Pulsar Basic is virtually maintenance-free. The necessary cleaning and
maintenance work can be carried out by the user after a short instruction.
The measures and intervals listed here are recommendations by inVENTer GmbH to
maintain the functional and performance capability of your Pulsar Basic.
Depending on your needs and/or air quality, your personal cleaning schedule
may vary from these recommendations.
Time span | Assembly | Maintenance measure |
---|---|---|
Monthly | Fan housing | Clean the surface with a damp cloth. |
Semiannual | Fan unit | **** 22 |
Cleaning agents:
The Pulsar Basic exhaust fan has a plastic surface that is sensitive to
scratches. Do not use cleaning agents containing sand, soda, acid or chlorine
to avoid damaging the surface.
A commercial detergent in warm water can be used to clean the surfaces.
Procedure:
► Switch on the power supply.
- AC 230 V: Disconnect the exhaust fan Pulsar Basic at the switch. The switch is located in the left side of the fan housing. Push it to position 0.
- DC 12 V: Interrupt the power supply at the mains fuse or at the external switch.
► Reach behind the fan unit with both hands.
► Pull the fan unit forward off the fan housing.
Hold the fan unit firmily so it does not fall to the floor when removed.
NOTICE The fan of the ventilation unit must not be immersed or sprayed
directly with water.
► Clean the wall sleeve, the fan housing and the fan unit with a damp cloth.
The fan is cleaned directly at the fan unit, it must not be dismantled.
► Carefully place the fan unit into the guides (red arrow) of the fan housing.
Do not tilt the fan when inserting it so as not to damage the contacts.
An audible click confirms that the fan unit is correctly inserted.
Technical Data
Exhaust fan Pulsar Basic
Feature | Value |
---|---|
Protection class | II |
Protection type | IP44 |
Input voltage | AC 230 V oder |
DC 12 V
Exhaust air volume flow (free-blowing) [m3/h]| 110
Power consumption| 4
Sound emmision (evaluated) [dB(A)]| 17 — 20
Ambient temperature [°C]| 5 — 50
Output| Without aggresive gases, dust and oils
Diameter x Deep [mm] AC 177 V, 81| Hz:
Weight [g]| 400
Flush-mounted power supply unit NT16
Feature | Value |
---|---|
Protection class | II |
Protection type | IP20 |
Input voltage [V AC, Hz] | 230 – 50 |
Input voltage [V DC, Hz] | 12 |
Power consumption | 12 |
Ambient temperature [°C] | 5 – 50 |
Diameter x Deep [mm] | 54 x 32 |
Weight [g] | 47 |
Air flow characteristic exhaust fan Pulsar Basic
Scope of supply
Component | Oder number |
---|---|
Pulsar Basic icl. Rubber seal (separately in packing box) | 3002-0299 |
Accesories
Component | Oder number |
---|---|
aV100 Wall mounting set | 1001-0159 |
Power supply unit – UP NT16 | 1003-0094 |
Flush-mounted box 60×66 | 3002-0244 |
Box Cavity Wall 61×68 | 1003-0084 |
Service
Complaints
Check the delivery for completeness and transport damage upon receipt, using
the delivery note. Complain about missing items immediately, at the latest
within 14 days, to
your supplier, dealer or factory representative.
Accesories and spare parts
To order components for your ventilation unit, contact your factory
representative or our service staff.
Technical customer service:
For technical advice, please contact our service staff:
+49 (0) 36427 211-0
+49 (0) 36427 211-13
info@inventer.de
**** www.inventer.eu
Disposal
Dispose of the product in accordance with the applicable national regulations.
The products described in this documentation are largely recyclable due to
their low-pollutant processing.
Contact a disposal company for electronic equipment for enviromentally frendly
recycling and disposal of your old system.
The disassembly required for disposal is performed in reverse order of
assembly.
Warranty and guarantee
Warranty
Outside Germany, the national warranty regulations of the country in which the
system is sold apply. Contact the dealer of your home country.
The warranty covers all defects that were present at the time of purchase.
Observe the intended use in order to maintain the warranty claim.
Manufacturer´s guarantee
The manufacturer provides a five-year warranty for the Pulsar Basic exhaust
fan. This covers premature product wear.
For information on the guarantee provisions, see
www.inventer.de/guarantee.
Warranty and guarantee claim
In the event of a warranty or guarantee claim, contact the dealer or factory
representative responsible for you.
In any case, send the complete unit back to the manufacturer. The warranty
claim is an additional offer by the manufacturer and does not affect
applicable law in any
way.
inVENTer GmbH
Ortsstraße 4a
D-07751 Löberschütz
www.inventer.eu
Subject to modifications.
No liability for printing errors.
Product Number: 5010-0016
009-500029-C
Version: 3.0 – 11/2022
Documents / Resources
|
inVENTer 3002-0270 Pulsar Basic Exhaust
Fan
[pdf] Instruction Manual
3002-0270, Pulsar Basic, Exhaust Fan, Pulsar Basic Exhaust Fan, 3002-0270
Pulsar Basic Exhaust Fan, Fan
---|---
References
- inVENTer-Herstellergarantie - Vertrauen Sie auf Qualität
- Decentralized ventilation systems - invisible, energy-efficient, silent
- Downloads - inVENTer