ESHINE E3100 Adjustable Bed Frame Owner’s Manual

August 10, 2024
ESHINE

ESHINE E3100 Adjustable Bed Frame

Specifications

  • Model: E3100
  • Features: Remote-controlled bed frame with various adjustment functions

Product Usage Instructions

  • Installation of Bed Legs
    • Attention: Install the bed legs after the bed frame is laid flat/leveled.
  • Troubleshooting Self-Check
    • Step 1: Check Contents
    • 1. Remote Control
    • After installing the batteries, press the remote control to check if the light is on.
    • Normal Situation: The light is on.
    • Abnormal Situation and Treatment: If the light is off, contact customer service for a replacement of the remote control.
    • Step 2: Pairing
    • Press PAIR buttons simultaneously for 5 seconds for pairing.
    • The backlight of the remote will flash, and then the remote control can activate the bed.
    • If pairing fails, unplug the power cord, wait for the green light to turn off for 1 minute, then plug it in while pressing the PAIR button on the remote control for 5 seconds.
    • If it still fails to pair, contact customer service for a replacement of the remote control.
    • Step 3: Child Lock
    • To ACTIVATE or DEACTIVATE the Child Lock Button on the remote.
    • If the remote control is working properly but cannot control the bed, press and hold the CHILDLOCK for 5 seconds to restore.
    • Step 4: Power Supply & Control Box
    • Plug in the power supply to check if the green lights of the power supply and the control box are on.
    • Normal Situation: The lights are on.
    • Abnormal Situation and Treatment: If not on, contact customer service for corresponding replacements.
  • Spare Space between Headboard Bracket and Mattress
    • Raise and lower the head and foot to ensure smooth adjustment. Verify there is enough space between the headboard brackets and mattress if needed.
  • Emergency Power Down
    • If the bed is stuck in a position, follow these steps to return it to the flat position for normal use:
    • Locate the control box under the bed.
    • Press and hold the ‘PAIR’ button until the bed is flat (refer to Figure 3).

FAQs

Safety & Warranty Warnings

READ THE FOLLOWING INFORMATION CAREFULLY BEFORE USING THIS PRODUCT If unable to understand warnings, cautions, and/or instructions, contact the dealer or technical personnel if applicable, before attempting to use the equipment. Otherwise, injury or damage may result.

SAFETY WARNINGS:

  • Do not use bed outdoors.
  • Do not use bed near explosives.
  • Using bed with oxygen administering equipment other than the nasal masked type creates a possible fire hazard.
  • When using nasal or masked type administering equipment, route and secure oxygen or air tubing properly to ensure that tubing does not become entangled or damaged during normal operation of the bed.
  • Use caution when having liquids in or around the bed to ensure no spilling occurs. In case of spillage, stand in a dry, clean area of the floor and unplug the bed immediately. Clean up spill and allow the area around bed to dry thoroughly before using the electric controls again. Do not eat or drink hot liquids while operating the bed.
  • This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instructions concerning use of the appliance by a person responsible for their safety.
  • Do not allow children or individuals with disabilities to operate the bed without adult supervision.
  • Do not allow any person or pet under the bed at any time.
  • During bed operation, make sure body is positioned within the confines of the bed. Do not place extremities over the sides of the bed when operating bed functions.

WARRANTY WARNINGS:

  • Do not open or tamper with control box, motors, or remote (with the exception of battery compartments). The warranty will be void if the internal workings of these components are tampered with.

RADIO FREQUENCY: 2.4 GHz

Product Rating:

  • The motors are not designed to operate continuously for more than [2] minutes in an [18] minute time period or approximately 10% duty cycle.
  • Attempting to circumvent or exceed this rating will shorten the life expectancy of the foundation and may void the warranty.

Operating Information

  • After power foundation assembly is completed, operate remote control to ensure proper functions.
  • Keep moving parts free of obstruction during bed operation (including sheets, clothing, tubing, wiring, and products using electric power cords).
  • Distribute body weight evenly over bed surface. Do not place entire weight on head or foot sections of the bed, during repositioning and entering or exiting bed.

Hospital Use Disclaimer:

  • This power foundation is designed for residential use only. It is not approved for hospital use and does not comply with hospital standards.

Weight Limits:

This product is not rated to support weights in excess of 750 pounds inclusive of the mattress and bedding. The bed will structurally support this weight, provided it is evenly distributed across thefoundation. The power foundation is not designed to support or lift this amount in the head or foot sections alone. Exceeding this weight restriction could damage the bed and/or cause injury and will void the warranty.
WARNING: DO NOT USE THIS BED IF WEIGHT LIMITATION IS EXCEEDED.

RADIO FREQUENCY: 2.4 GHz

FCC COMPLIANCE:

This device complies with Part 15 of the FCC Rules.

Operation is subject to the following two conditions:

  1. This device may not cause harmful interference, and
  2. this device must accept any interference received, including interference that may cause undesired operation.

To comply with the FCC RF exposure requirements, no change to the antenna or the device is permitted. Any change to the antenna or the device could result in the device exceeding the RF exposure requirement and void user’s right to operate the device.

PARTS LIST

All electronics and components that need to be installed are located in boxes under the foundation or attached to the frame. Before discarding the packing materials, ensure that all the parts are accounted for.

ESHINE ADJUSTABLE POWER BASE ELECTRONICS QUICK REFERENCE GUIDE ESHINE WIRELESS OVERVIEW

INSTALLATION

OPEN THE PACKAGE
For safety reasons, lifting of the adjustable bed frame must be performed by two (2) people; and the unit should always be in flat position before opening.

ATTACHING THE BED LEGS
Remove the six (6) bed legs from the accessory box. Hand tighten the legs by threading them clockwise into the pre-threaded holes on the bed frame.

Attention: install the bed legs after the bed frame is laid flat/ leveled.

INSTALLING THE RETAINER BAR

  • STEP 1 Turn the bed frame over carefully, top side up.
  • STEP 2 Insert the ends of the retainer bar into the quick connect brackets located at the foot of the bed.

Setting up the electronics

  • STEP 1
    • Take out the power supply and the power cord from the accessory box.
  • STEP 2
    • Connect the power supply lead from the control box to the power supply.
  • STEP 3
    • Connect the power cord that was packaged with the power supply to the power supply.
  • STEP 4
    • Plug the power cord into a working electrical outlet.
    • The LED lights under the base will flash for 10 seconds.
  • STEP 5
    • Install the two (2) AAA batteries into the remote control.
  • STEP 6
    • Confirm the remote control works by pressing the lift buttons. Installation for single or independent operation of the bed frame is now complete.

ESHINE Remote Control Instuctions

ESHINE WIRELESS REMOTE

ADJUST

ONE TOUCH BUTTONS

MASSAGE FEATURE

Setting Programmable Positions and Pairing Remote SETTING PROGRAMMABLE POSITIONS

The wireless power bed has a programmable feature that allows you to save custom positions. Please read all the instructions below before setting your custom presets on the remote.

  • STEP 1 Adjust the head and foot to your desired position.
  • STEP 2 Press and hold the flat button first. Next, Choose your favorite sleep positon. Then press and hold memory button for 5 seconds until the buttons’ lights are flashing. The position is then saved.
  • STEP 3 To adjust the saved position, repeat steps 1 and 2 and the new position will be saved.

PAIRING REMOTE
The original remote that comes in the box is already paired to the foundation. No further action is required. In the event that the remote is not paired with the foundation, follow the steps below.

  • STEP 1 Make sure the batteries work fine. Replace them when needed.
  • STEP 2 Plug the power cord to the power source.
  • STEP 3 Unplug and plug power cord into power source. Immediately press and hold the “PAIR’ button for 5 seconds – lights will flash then stop. Remote is now paired.

Special Function

EMERGENCY POWER DOWN
Your adjustable bed frame comes with a power supply that, when powered with two new 9V batteries, supports the emergency power down feature. If a power failure occurs while the head and/or foot sections are raised, do the following:

  • STEP 1
    • Install two (2) new 9V batteries in the battery compartment of the power supply.
  • STEP 2
    • Press the flat position on the remote if there is no power from the electrical outlet.
  • STEP 3
    • Replace the two (2) 9V batteries after this procedure. The 9V batteries (not included in the box) are for single use only.

SYNCHRONIZING TWO BED (OPTION)
If simultaneous operation of two foundations is desired, please read the instructions.

  • STEP 1 Plug A and B bases to power source.
  • STEP 2 Plug the synchronizing cable into 2 control boxes of 2 bases.
  • STEP 3 Then base A and B can be simultaneous operated by Remote A.

Troubleshooting

Troubleshooting Self-Check

CONTACT INFORMATION

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals