Safety & Warranty Warnings
READ THE FOLLOWING INFORMATION CAREFULLY BEFORE USING THIS PRODUCT
If unable to understand warnings, cautions, and/or instructions, contact the
dealer or technical personnel if applicable, before attempting to use the
equipment. Otherwise, injury or damage may result.
SAFETY WARNINGS:
- Do not use a bed outdoors.
- Do not use a bed near explosives.
- Using a bed with oxygen-administering equipment other than the nasal-masked type creates a possible fire hazard.
- When using nasal or masked type administering equipment, route and secure oxygen or air tubing properly to ensure that tubing does not become entangled or damaged during normal operation of the bed.
- Use caution when having liquids in or around the bed to ensure no spilling occurs. In case of spillage, stand in a dry, clean area of the floor and unplug the bed immediately. Clean up the spill and allow the area around the bed to dry thoroughly before using the electric controls again. Do not eat or drink hot liquids while operating the bed.
- This appliance is not intended for use by persons (including children) with reduced physical, sensory, or mental capabilities, or lack of experience and knowledge unless they have been given supervision or instructions concerning the use of the appliance by a person responsible for their safety.
- Do not allow children or individuals with disabilities to operate the bed without adult supervision.
- Do not allow any person or pet under the bed at any time.
- During bed operation, make sure the body is positioned within the confines of the bed. Do not place extremities over the sides of the bed when operating bed functions.
WARRANTY WARNINGS:
Do not open or tamper with the control box, motors, or remote (except battery
compartments). The warranty will be void if the internal workings of these
components are tampered with.
RADIO FREQUENCY: 2.4 GHz
Product Rating:
The motors are not designed to operate continuously for more than [2] minutes
in an (18-minute time period or approximately 10% duty cycle. Attempting to
circumvent or exceed this rating will shorten the life expectancy of the
foundation and may void the warranty.
Operating Information:
- After the power foundation assembly is completed, operate the remote control to ensure proper functions.
- Keep moving parts free of obstruction during bed operation (including sheets, clothing, tubing, wiring, and products using electric power cords).
- Distribute body weight evenly over the bed surface. Do not place entire weight on the head or foot sections of the bed, during repositioning and entering or exiting the bed.
Hospital Use Disclaimer:
This power foundation is designed for residential use only. It is not approved
for hospital use and does not comply with hospital standards.
Weight Limits:
This product is not rated to support weights over 750 pounds inclusive of the
mattress and bedding. The bed will structurally support this weight, provided
it is evenly distributed across the foundation. The power foundation is not
designed to support or lift this amount in the head or foot sections alone.
Exceeding this weight restriction could damage the bed and/or cause injury and
will void the warranty.
A WARNING
DO NOT USE THIS BED IF THE WEIGHT LIMITATION IS EXCEEDED.
FCC COMPLIANCE:
This device complies with Part 15 of the FCC Rules.
Operation is subject to the following two conditions:
- This device may not cause harmful interference, and
- this device must accept any interference received, including interference that may cause undesired operation.
To comply with the FCC RF exposure requirements, no change to the antenna or the device is permitted. Any change to the antenna or the device could result in the device exceeding the RF exposure requirement and vtheuthe ser’s right to operate the device.
Parts List
All electronics and components that need to be installed are located in boxes
under the foundation or attached to the frame. Before discarding the packing
materials, ensure that all the parts are accounted for.
ESHINE ADJUSTABLE POWER BASE ELECTRONICS QUICK REFERENCE GUIDE
ESHINE WIRELESS OVERVIEW
Installation Guide
OPEN THE PACKAGE
For safety reasons, lifting of the adjustable bed frame must be performed
by two (2) people; and the unit should always be in a flat position before
opening
ATTACHING THE BED LEGS
Remove the six (6) bed legs from the accessory box.Hand-tightenn the legs
by threading them clockwise into the pre-threaded holes on the bed frame.
INSTALLING THE RETAINER BAR
-
STEP 1
Turn the bed frame over carefully, top side up. -
STEP2
Insert the ends of the retainer bar into the quick-connect brackets located at the foot of the bed.
Setting up the electronics
-
STEP 1
Take out the power supply and the power cord from the accessory box. -
STEP2
Connect the power supply lead from the control box to the power supply. -
STEP3
Connect the power cord that was packaged with the power supply to the power supply. -
STEP4
Plug the power cord into a working electrical outlet. The LED lights under the base will flash for 10 seconds. -
STEPS
Install the two (2) AAA batteries into the remote control. -
STEP6
Confirm the remote control works by pressing the lift buttons. Installation for single or independent operation of the bed frame is now complete.
SHINE Remote Control Instructions
I ESHINE WIRELESS REMOTE
Setting Programmable Positions and Pairing Remote
SETTING PROGRAMMABLE POSITIONS
The wireless power bed has a programmable feature that allows you to save
custom positions. Please read all the instructions below before setting your
custom presets on the remote.
STEP 1
Adjust the head and foot to your desired position.
STEP2
Press and hold the flat button first. Next, Choose your favorite sleep
position. Then press and hold the memory button ? for 5 seconds until the
buttons’ lights are flashing. The position is then saved
STEP3
To adjust the saved position, repeat steps 1 and 2 and the new position will
be saved.
PAIRING REMOTE
The original remote that comes in the box is already paired with the
foundation. No further action is required. If the remote is not paired with
the foundation, follow the steps below.
STEP 1
Make sure the batteries work fine. Replace them when needed.
STEP2
Plug the power cord to the power source.
STEP3
Unplug and plug the power cord into a power source. Immediately press and hold
the “PAIR’ button for 5 seconds – lights will flash and then stop. Remote is
now paired.
Special Function
EMERGENCY POWER DOWN
Your adjustable bed frame comes with a power supply that, when powered with
two new 9V batteries, supports the emergency ppower-downfeature.
If a power failure occurs while the head and/or foot sections are raised, do the following:
-
STEP 1
Install two (2) new 9V batteries in the battery compartment of the power supply. -
STEP2
Press the flat position on the remote if there is no power from the electrical outlet. -
STEP3
Replace the two (2) 9V batteries after this procedure. The 9V batteries (not included in the box) are for single use only.
SYNCHRONIZING TWO BED (OPTION)
If simultaneous operation of two foundations is desired, please read the
instructions.
-
STEP 1
Plug A and B bases into a power source. -
STEP2
Plug the synchronizing cable into 2 control boxes of 2 bases. -
STEP3
Then base A and B can be simultaneously operated by Remote A.
Remark: If you don’t need Synchronizing just remove the Synchronizing
cable.
Note: Synch cord is included with Twin Long Bases only.
Troubleshooting
In the event that the power foundation fails to operate, assess the symptoms and possible solutions provided in the chart below.
BY ESHINE SLEEP
POWER ADJUSTABLE BASE
If you have had any issues with the assembly process.you can contact our
Customer Service Email sales 1 @eshinesleep.com.