ZigBee TRV601 Smart Thermostatic Radiator Valve User Guide

August 9, 2024
zigbee

ZigBee TRV601 Smart Thermostatic Radiator Valve

ZigBee TRV601 Smart Thermostatic Radiator Valve

Product Introduction

Standard accessories

|
---|---
TRV| User Manual
| | | | Standard accessories|
For Danfoss RA valves| For Danfoss RAV valves| For Danfoss RAVL valves| For Caleffi valves| For Giacomini valves| For M28 valves
Adapters

Technical specifications

Power Supply: 3 x 1.5 V alkaline AA batteries (not included)
Current Consumption: 100mA Max
Protection Degree: IP20
Ambient Temperature: 0~50℃
Surface Temperature: 90℃ Max (at the radiator)
Connection: M30 x 1.5mm
Linear Travel: 4.3mm
Dimensions(W x H x D): 58.4mm x 97mm x 58.4mm
Weight: 117.7 g
  1. interface and buttons
    Standard accessories

  2. Dimentions
    Standard accessories

Installation

  1. Press the battery compartment lock, remove the cover, and insert the batteries.
    Installation

  2. Initialize, the mandrel pull back, then “ ” is displayed and blinking on the screen.

  3. When” ” stop blinking, install the TRV union nut with M30*1.5 thread for heating valve, and then tighten the nut.
    Installation
    *Attention:
    While 1nsert1ng the batteries, please make sure the polarity of battery(+/-) is aligned.

  4. Press the middle button and then “ ” start blinking, the device enter valve-adjusting process. After several minutes, the process is completed when initialized screen is displayed.
    Installation

How to install the adapter correctly

For Danfoss RA valves For Danfoss RAV valves For Danfoss RAVL valves
For Caleffi valves For Giacomini valves For M28 valves
![How to install the adapter correctly](https://manuals.plus/wp-

content/uploads/2024/08/ZigBee-TRV601-Smart-Thermostatic-Radiator-Valve-User- Guide-25.png)

Function Introduction

Tempe. control mode

Press the middle button to switch between Auto mode and Manual mode.

  • Attention: Only Manual mode is available when the device is not connected to Internet.

    • Auto mode
      When “ ” is displayed on the screen, it is under Auto mode.
      Four time periods and setting temperature could be programmed per day, one week as a cycle, based on customized needs.

    • Manual mode
      When “ ” is not displayed on the screen, it is under Manual mode.
      The device will work according to current setting temperature, without controlled by the time period program.
      Tempe. control mode

    • Temporary mode
      Under Auto mode,” ” will be blinking after setting temperature, and then it will enter Temporary mode. The device is switched to Manual mode temporarily, without controlled by the time period program. It will return to Auto mode by next time period.

Stop heating and pause heating

  • ON: In summer, rotate the knob clockwise until “ ” is displayed under manual mode to stop heating. At this time, the heating valve is fully open. This can extend the use life of valve.

  • OFF: In winter, rotate the knob counterclockwise until “ ” is displayed under manual mode to pause heating temporarily. At this time, the heating valve is closed and the frost protection is activated.

*Attention: After the antifreeze function is activated, the valve will open when the room temperature is lower than 5°C, and the valve will be closed when the room temperature exceeds 7°C to prevent damage to the radiator thermostatic valve due to freezing.

  • Adjust setting temperature : Rotate the knob to adjust setting temperature, stepping by 0.5°C.

  • Screen rotation: Long press the Set Button for 3 seconds to switch the screen display direction.
    Stop heating and pause heating

  • Open-window function : First, enter the APP home page to tum on the window detection function, the device will automatically identify whether the window is open. When it is detected that there is cold wind, and the temperature drops by more than 1.5°C within 4.5 min, the open-window function will be activated.
    At this time, the screen displays “ ” and the temperature is set to 12 °C.

  • Anti-scale : TRV executes routine decalcification every Monday at 12:00 to protect the valve from calcification. “ ” will be displayed on the screen during decalcification.

  • Child lock function : Long press the middle button for 3 seconds until “ ” is displayed on the screen to activate the child lock. While the device is locked, long press middle button for 3 seconds until “ ” disappear to deactivate the child lock.
    Child lock function:

  • Restore factory settings Long press the middle button and insert the battery at the same time until “ ” is displayed on the screen and blinking for 3 seconds, the device will be restored to factory settings and restarted.

*Attention: Once the device is restored to factory settings, all previous settings can not be recovered.

APP remote control and voice control

APP remote control and voice control

Network Configuration

Download Smart Life APP

| QR Code|
---|---|---

Scan the QR code above or search “Smart Life” on App Store and Google Play to download the Smart Life APP.

Add gateway

  1. When the gateway is powered on, hold button for 5 seconds until the red light blinks rapidly.

  2. Enter the Home page, click “ ” in the upper right corner, select Gateway Control – Wireless Gateway (Zigbee).
    Add gateway

  3. Select 2.4GHz Wi-Fi network and enter password, click “Next” , confirm the indicator is blinking rapidly, and then click “Next”.
    Add gateway

  4. Wait a moment until the device is found and initialized, then click “Done” to finish.
    Add gateway

Add device

  1. Under manual mode, rotate the knob counterclockwise until “ ” is displayed. Then long press the middle button for 3 seconds until “ ” is blinking.
    Add device
    *Attention: Network configuration can only be done under manual mode.
    The gateway must be added before adding TRV.
    The TRV must be added in the page of gateway.

  2. In the page of gateway, click “Add sub device”, click “LED already blink”, wait a moment until the icon of TRV appears, then click “Done”.
    Add device

  3. Set the device name, and click “Done” to finish. The device has been added successfully.
    Add device

APP Features

Mode selection

  • Click “ ” to select mode.
    Mode selection

*Attention: Click ” + ” or ” ” to adjust the setting temperature.

Auto mode: Four time periods and setting temp. could be programmed per day, one week as a cycle, based on customized needs.

Manual mode: The device will work according to current setting temp.
without controlled by the time period program.

Off mode: The valve will be closed to stop heating.

Week program setting

  1. Click “ ” to enter the week program setting page.
    Week program setting

  2. Set four time periods and setting temperature based on customized needs.
    Week program setting

Advanced setting

  • Click “ ” to enter the advanced setting page.
    Advanced setting

Device sharing function

  • Share the device to other family members, allowing them to remotely control the TRV device.
  1. Click the Menu button, then click “Share Device”
    Device sharing function

  2. Click “Add home member”.
    Device sharing function

  3. Fill in account information of home member.
    Device sharing function

  4. Choose an invitation method.
    Device sharing function

Voice control

  • After waking up the speaker, you can say:

Amazon Alexa: Alexa,

  • Set the living room to 26 degree
  • Drop the living room by 1 degree
  • Raise the living room by 1 degree
  • Make the living room warmer
  • Turn on the living room child lock
  • Turnoff the living room child lock
  • What temperature is the living room set to
  • What is battery on the living room

Google Assistant : OK google,

  • Set the living room to 23 degree
  • Turn on the living room child lock
  • Turnoff the living room child lock
  • IS my living room child lock on?
  • Turn on child lock for the living room
  • Turnoff child lock for the living room
  • Set the living room to auto
  • Set the living room to manual

*Attention ” living room ” is the device name, you can also name it yourself.
The temperature unit of TRV and smart speaker must be identical.

Error code

Troubleshooting and maintenance

Error code Problem Solution
FD Temperature sensor abnormality Contact after-sales staff
F1 Slow valve operation Check the installation and heating valve
F2 The stroke is too long Check the fastening of TRV
F3 The stroke is too short Check the heating valve
F4 Running out of battery Replace batteries immediately
Battery symbol ( ) Low battery Replace batteries within 4 weeks

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals