EVAstream USER MANUAL
A step-by-step user’s guide to getting started
EVAstream Series Counter Current Swimming Machine
IMPORTANT SAFETY INSTRUCTIONS
Important safety instructions: rotating parts
The EVAstream Move is a powerful machine with rotating parts. Safety measures
have been taken to ensure the safety of fingers, toes and also to prevent hair
entanglement.
Nevertheless, you should always maintain a safe distance from the machine.
Despite the safety measures implemented to prevent hair entanglement, every
EVAstream user is advised to wear a swim cap. EVAstream complies with the
following safety standards: DIN EN16582-1/2/3, EN16713-2 (residential pools)
and EN13451-1/3
(commercial pools).
Important safety instructions: child supervision and safety
The EVAstream should not be used by children under 8 years old. Children under
16 years of age should never use EVAstream without adult supervision. The
EVAstream Move may only be placed in the pool by an adult.
The EVAstream Move is not a toy. Keep your distance from the machine and
absolutely do not hang from, pull on or sit on top of the turbine.
Never use or store the EVAstream in a room/area where the temperature is below
the freezing point.
OVERVIEW EVASTREAM INSTALLATION
Overview
2.1 EVAstream Turbine The EVAstream is a counter-current machine. Water
suction takes place through the grids around the machine. Always make sure
that the suction parts are completely free of obstacles. These parts of the
machine must not be closed or blocked in any way.
General specifications
Power input | 230 VAC; 11A |
---|---|
Cable motor | 5 m, 16 mm 2 |
• Extend with max 20m using 25mm2 cable
• Extend with max 25m using 35mm2 cable (Flexible cable of fine copper wire
strands)
Electrical specifications – AC/DC Power Supply / INPUT
Voltage range | 180-264 Vac |
---|---|
Frequency range | 254-370VDC |
AC current (230VAC) | 47-63Hz |
Nominal power | FIT: 5.5A FIT: 1200VA |
Power factor (type) | >0.9 |
Electrical specifications – AC/DC Power Supply / OUTPUT
DC bus voltage (stabilized) | FIT: 26Vdc | PRO: 28Vdc | MAX: 28Vdc |
---|---|---|---|
DC current | FIT: 46A | PRO: 71A | MAX: 86A |
Protections
Short circuit, overload, over voltage, over temperature.
Safety standards
SELV, UL62368-1, CSA C22.2 No. 62368-1, TUV EN62368-1 + A11, EAC TP TC 004,
BSMI CNS14336-1 approved, EN55032 (CISPR32) Class A/B, EN61000-3-2/3,
EN61000-4-2/3/4/5/6/8/11, EN55024, EN61204-3, EN61000-6-2, BSMI CNS13438.
2.2 Motor Control Unit (MCU)
The motor control unit (MCU) of the EVAstream is placed in the technical area
near the pool (a dry and condensation-free environment, zone 2). Image:
Motor Control Unit (MCU) >
Connections MCU
- Control print (32 pins)
- Remote reciever
- EVAstream turbine connection
- UTP connector
- Power connection
Electrical specifications – MCU
Control input | DMX512 |
---|---|
Motor PMSM 3xDC Output | RPM range – 10-100% |
IP rating EVAstream | IP20 |
Max dimensions | 660x224x116 mm (cable gland on bottom) |
EVAstream Pro/Fit dimensions | 660x186x116 mm (cable gland on bottom) |
Working temperature
Max. 32°C, mount in a dry and condensation-free area. Provide space around the
MCU for efficient heat management. Sides at least 5 cm and top bottom at least
10 cm.
Safety measures
EVA Torque control, Voltage/current control and Mosfet temperature control.
2.3 On/off switch
If the EVAStream is permanently connected to 230V mains the installation must
additionally be equipped with an on/off switch mounted near the swimming pool
where the EVAstream is located.
After use, the power has to be switched off.
2.4 Remote control
Electrical specifications – Receiver
Radio frequency band | 433.92 MHz |
---|---|
Antenna | BNC connector, external antenna in option (preferably dipole antenna |
for DIN-receivers and 1/2 – or 1/4 antenna for wall mounting The antenna is supplied as standard with a 10 m. cable.
Electrical specifications – Remote control
Radio frequency band | 433.92 MHz |
---|---|
On/off switch | included |
IP-rating | IP67 |
Environmental conditions | -20°C to +55°C / -4°F to +130°F (humidity 10–90%) |
Moisture | 10-90% |
Dimensions | 65x 112 x 35 mm / 2.6 x 4.4 x 1.4 inch |
OPTIONAL PRODUCTS
2.5 Antenna
If the remote control has insufficient range, the supplied antenna can be
installed.
General specifications
Frequency | 433.92 MHz |
---|---|
Weight | 426 grams |
Dimensions | 33x195x33 mm |
Range | 50 m, in open field |
2.6 EVA Experience web app
Use the EVA Experience web app to manage the EVAstream.
For instructions on how to set up the tablet environment, please refer to
chapter 6.
2.7 EVA LED underwater lighting
The EVA RGBW LED underwater pool lighting complete the counter current pool
experience.
The underwater lighting guides you through the training.
CREATE THE BEST SWIMMING ZONE
-
Determine swimming zone
You start by determining your swimming zone, see the image below: *Measurements based on an adult professional swimmer.
Body size and mass affect swim speed. -
Turbine placement EVAstream 250 mm
For the positioning of the turbine we advise 250 milimeters (centre of the turbine) below water level. Mount the EVAstream horizontally in the wall, in the middle of the wall. -
Check the swimming zone
The flow is directed at the torso and not at the head, so that there is free breathing space while swimming. The current is also wide and stable enough to encompass the entire body. When you swim over the water flow, or you get water in your face, the turbine has to be adjusted. **** -
Adjust the turbine if necessary
You can adjust the turbine a little higher or lower with the adjustment jig at the customer’s request. The turbine can be adjusted a maximum of 2 degrees downwards or 3 degrees upwards using adjusting bolts on the side. This way you ensure that every customer has an optimal swimming experience.
CLEANING AND MAINTENANCE
4.1 Read before cleaning
WARNING
You should first make sure that the installation completely voltage-free by
removing the plug from the socket. If the installation is permanently
connected to 230V mains, switch off the main switch/isolation switch (mounted
in the technical space near the Motor Control Unit) before you start working.
It is not enough to use the on/off switch, as this does not make the
installation completely voltage-free. You must use the isolation switch to de-
energise the entire installation!
4.2 Cleaning after use, winter storage and maintenance
NOTICE
- The EVAstream comes equipped with a connection cable with a power plug. Before carrying out any maintenance, you must remove the plug from the socket, disconnecting the installation from the power supply.
- The flexible surface-mounted version (mounted with EVA-SM-A00/A01/A02/A03) of the EVAstream can easily attached to the pool wall before use and remove it again after use. We advise you to remove the machine from the pool when you are not using it.
- If you do not heat the pool during the autumn/winter period, remove the EVAstream (turbine) from the pool. The EVAstream turbine must remain frost-free. If the EVAstream or parts of it are frozen, it can causeirreparable damage to the machine.
- Using the EVAstream if the power cable is damaged is not permitted. Always ensure the safety of yourself and other users, especially when using electrical devices in and near water.
- Never clean the machine with concentrated cleaning agents.
- At the end of the life cycle of the EVAstream, the device/parts must be returned, in accordance with your local guidelines, to the appropriate collection points.
REMOTE CONTROL
The Remote control is automatically connected to the EVAstream.
If you also want to control the lighting with the remote control, this group
must be switched on manually. You can enable this in the EVA Experience web
app (chapter 6).
The Remote control has the following control options:
1. EVA Remote control options
ON/OFF button | EVAstream ON/OFF |
---|---|
Button + | |
Short press: | increase intensity 5% |
Long press: | increase intensity as long as you press for a stepless increase |
in speed
Button –|
Short press:| decrease intensity 5%
Long press:| decrease intensity as long as you press for a stepless decrease
in speed
2. On/off Switch
The remote control has an on/off switch on the back. The on/off switch disconnects power from the battery. In the 0/off position, the remote control will not function. 3. Replacing the batteries
- Remove the back piece (3 screws).
- Remove the batteries.
- Insert the new batteries.
- Replace the back piece (3 screws).
EVA EXPERIENCE WEB APP
By default, the EVAstream is controlled with the included remote control. In
addition, the EVA Experience web app can be added for an enhanced swimming
experience.
We have developed a complete training program for swimmers of every age and
every skill level. The workouts consist of interval, sprint and endurance
elements and increase in duration and intensity. Use the EVA Experience web
app as your very own personal swimming trainer!
For installing and setting up the web app, scan the QR codes below: If you are
unable to connect to the EVAstream Wi-Fi network (step 1), please visit the
step-by-step overview on our website for alternate connection options:
SAFETY STANDARDS
The EVAstream swimming machine is an extra low voltage (ELV) system. Due to
the very low voltage, the machine is suitable for use in both private and
public swimming pools. Due to the very low voltage, the EVAstream swimming
machines fall well outside
of the scope of both the Machinery Directive 2006/42/EC (1000Vac/1500Vdc or
higher) and the Low Voltage Directive 2014/35/EU (50Vac/75Vdc –
1000Vac/1500Vdc). Although the EVAstream (with a maximum of 30Vdc) falls well
outside of the scope of these standards, all EVAstream models meet the
relevant safety requirements as stated in both guidelines.
Specific safety standards for swimming pool products and installations All
EVAstream models comply with the following specific standards and guidelines
for use in swimming pools. These standards focus, among other things, on
electrical safety, electromagnetic interference and protection against hair
entanglement (hair safety).
NEN-EN 16582-1/2/3:2015+A1:2021
Swimming pools for private use –
Part 1: General requirements, including safety requirements and test methods
Part 2: Specific requirements, including safety requirements and test methods
for inground swimming pools
Part 3: Specific requirements, including safety requirements and test methods,
for above-ground swimming pools
NEN-EN 16713-2:2016
Swimming pools for private use – Water systems –
Part 2: Circulation systems – Requirements and test methods NEN-EN
13451-1:2020
Swimming pool equipment –
Part 1: General safety requirements and test methods for swimming pool
equipment installed in public swimming pools
NEN-EN 13451-3:2022
Swimming pool equipment –
Part 3: Additional specific safety requirements and test methods for swimming
water inlets and outlets and for water/air based water attractions
EN 60364-7-702/ DIN VDE 0100-702:2012-03
Low-voltage electrical installations –
Part 7-702: Requirements for special installations, rooms and areas – Swimming
pools and fountains
Directive 2014/30/EU
Electromagnetic Compatibility (EMC)
Battery charging system
IEC EN 60950-1:2006+A11:2009+A1:2010+A12:2011+A2: 2013
IEC EN 55022:2010+AC:2011
IEC EN 55024:2010+A1:2015
IEC EN 61000-3-2:2019
IEC EN 61000-3-3:2013+A1:2019
IEC EN 61000-4-2/3/4/5/6/11
IEC EN 55032:2015
IEC EN 55035:2017
UN 38.3
UN 3481
IEC EN 62133
GENERAL SAFETY INSTRUCTIONS
8.1 Read before use
- Follow the directions for electrical installation and use carefully.
- Failure to comply or inadequate compliance with these important instructions can result in serious personal injury or property damage.
- We do not accept any claim under warranty and/or liability for material and/or intangible damage as a result of failure to comply with these regulations regarding installation, mounting, and use.
- The general terms and conditions of EVA Tech B.V. apply to all our offers and agreements. EVA Tech B.V. expressly rejects the applicability of the general (purchasing) conditions of counterparties. The warranty provisions of the EVAstream and the general terms and of EVA Tech B.V. apply to all our offers and agreements.
8.2 Important general information
- EVAstream is a powerful machine. The machine includes a very powerful motor with rotating parts. As with any machine, always consider your safety and the safety of others when using it.
- The EVAstream Move is a powerful machine with rotating parts. Safety measures have been taken to ensure the safety of fingers, toes and also to prevent hair entanglement. Nevertheless, you should always maintain a safe distance from the machine.
- Despite the safety measures implemented to prevent hair entanglement, every EVAstream user is advised to wear a swim cap. EVAstream complies with the following safety standards: DIN EN16582-1/2/3, EN16713-2 (residential pools) and EN13451-1/3 (commercial pools).
WHEN SHOULD THE EVASTREAM NOT BE USED
People who do not have an official certificate of swimming proficiency (swimming diploma) may under no circumstances use the EVAstream.
- The EVAstream should not be used by children under 8 years old.
- Children under 16 years of age should never use EVAstream without adult supervision.
- Never leave children alone when the EVAstream is on or can be easily turned on.
- Always keep your attention on the swimmer.
- The EVAstream should not be used by persons with limited physical and/or sensory, or mental capabilities unless they are under the supervision of a qualified person responsible for their safety.
- Using the EVAstream if you have consumed alcohol, drugs, or medication that affects your ability to react is not permitted.
- Not for use in potentially explosive areas.
- Not for use in any aggressive environments (in the presence of gases, acids, vapours, substances, oils).
- Not for use in dirty water.
- The turbine should never be used outside of the water. Doing so will void the warranty.
USING THE EVASTREAM SAFELY
10.1 Read before use
- Every user and operator of the EVAstream must read the operating instructions in full, in advance. The regulations must be followed carefully at all times.
- Make sure that there are no people near the suction and outflow area of the turbine before turning on the EVAstream.
- The machine may only be operated under water. The machine must always be fully submerged before use. Serious and permanent damage to the machine can occur if the EVAstream is not submerged during use.
- The water (water values) and surroundings must meet the requirements for environmental conditions.
- Installation depth: the EVAstream can be placed at a maximum of 50 cm below water level.
- The machine and the pool in which it is placed must be free of obstacles before turning on the machine. Small objects and toys must be removed from the water and from the bottom to avoid damage to the machine.
- The EVAstream is only intended to be used as a counter-current swimming machine.
- Use for any other purpose must be discussed with the manufacturer in advance and must be documented in writing.
- Make sure that EVAstream users always read these instructions before use.
- Store these operating instructions in an easily accessible place near the machine.
10.2 Rules for a safe use
- Despite the safety measures implemented to prevent hair entanglement, every EVAstream user is advised to wear a swim cap. Wearing a swim cap enhances your safety and swimming experience.
- Make sure that there are no people near the suction and outflow area of the turbine before turning on the EVAstream.
- The suction of water takes place around the machine.
- Always make sure that the suction parts are completely free of obstacles.
- These parts of the machine must never be closed or blocked in any way.
- This not only provides an adequate supply of water, but it also ensures that the suction power always remains within the required levels (EN 13451-1/3).
- When operating the EVAstream, always ensure that the machine and pool in which it is located are in sight.
- Make sure that toys and small parts have been removed from the water and the bottom of the pool before switching on the EVAstream.
- Always maintain a sufficient distance from the EVAstream for your safety. Sufficient distance is at least 50 cm on both the front and the sides.
- Consider the force of the flow when using the EVAstream. Adjust the speed to the strength and skill of the user.
- Ensure that no people stand, sit, or otherwise place weight on the machine.
- Never submerge the battery control unit of the EVAstream. The battery control unit should always be kept dry.
WATER VALUES
The user of the EVAstream is responsible for providing the right conditions for an optimal product life cycle. To fulfil the warranty conditions, the EVAstream should only be used in pools with a water composition within the following limits:
-
Water temperature: +1ºC to +35ºC
-
pH value: 6.8 – 7.8
-
Maximum chlorine levels for water:
– Indoor swimming pool – Free available chlorine (FAC): 0.5 ≤ VBC ≤ 1.5 mg/l
– Open-air swimming pool >= 20 m2
– Free available chlorine (FAC): 0.5 ≤ VBC ≤ 3.0 mg/l
– Open-air swimming pool < 20 m2
– Free available chlorine (FAC): 0.5 ≤ VBC ≤ 5.0 mg/L
– All basins – Bound available chlorine: < 0.6 mg/l -
The basin and the available accessories must be free of electrolysis.
-
Installation housing must be properly earthed to prevent electrolysis.
-
Cyanuric acid: ≤ 100 mg/l
-
Metals: ≈ 0 mg/l
-
Carbonate hardness: ≥ 2ºdH (ºdH = mmol/l x 2.8); (ºeH =mmol/l x 3.5); (ºfH = mmol/l x 5.0)
-
Ozone: 0 mg/l
-
Chlorite + chlorate: ≤ 30 mg/l
-
Redox potential: ≥ 700 mV
ENVIRONMENTAL CONDITIONS USE EVASTREAM
12.1 Ambient temperature of power supply box
(mounting in a dry condensation-free room)
0ºC to 32ºC
12.2 Water temperature
+1ºC to +35ºC
EVA Tech B.V.
de Velde 1
8064 PH Zwartsluis
The Netherlands
+31 (0)38 – 33 75 067
info@evaoptic.com
evaoptic.com
Documents / Resources
| EVA
EVAstream Series Counter Current Swimming
Machine
[pdf] User Manual
EVAstream Series Counter Current Swimming Machine, EVAstream Series, Counter
Current Swimming Machine, Current Swimming Machine, Swimming Machine, Machine
---|---