eva Meter Reader Smart User Manual
- May 15, 2024
- EVA
Table of Contents
Eva Meter Reader
Introduction
This Meter Reader for Norway connects to your AMS electricity meter through
the HAN port and read your electricity consumption in real time.
Connected to your Smart home app, it gives you an updated overview of your
power consumption in real time.
The Meter Reader supports AMS electricity meters as Aidon, Kamstrup and Kaifa.
Open the HAN Port
The HAN port on your AMS meter is by default switched off, and you must inform your electricity company that you want it opened. You can do this on their website or by calling the customer service.
Installation
- Open the Eva Smart Home App
- Select “add new device” and choose Eva Meter Reader
- Follow the in-app instructions to complete the setup process.
Connect the Meter Reader to the AMS Meter
The Meter Reader is connected to the HAN port on your modern AMS electricity
meter, which you can find in the fuse box.
With the Eva Meter Reader, you can retrieve real-time data and monitor your
consumption directly on your smart home system.
- Turn on the antenna
- Pull out the plastic tab
- Connect the network cable to the meter reader and the electricity meter.
Every time the meter
reader receives data from the power meter, the LED light will indicate this
with a short blue flash.
If the meter reader is not in pairing mode
- Remove the meter reader cover as described above to gain access to the push button.
- Press and hold the push button for more than 10 seconds to activate connection mode on the meter reader. When the button is released, the connection mode is indicated by the diode flashing blue rapidly three times followed by a 1 second pause).
- Put your hub in connect mode and wait for the meter reader to pair with the hub.
Factory reset
- Open the cover of the Meter Reader as described above to get access to the push button.
- Hold the push-button on the Meter Reader for more than 10 seconds to reset the Meter Reader and start pairing mode.
Pairing mode is indicated by the LED with 3 short blue flashes every second.
LED Indications
COLOR | PATTERN | EXPLANATION | NORMAL |
---|---|---|---|
**** Blue | **** Short flash | **** Message from electricity meter received |
OFF
Blue| Repeating: 3 short flashes, 1 second off| Pairing
mode| OFF
Blue| 1 second on/off toggle| Zigbee identify| OFF
Blue| Up to 10 medium flashes| Leave network: Meter Reader
has been removed from the Zigbee network. Pattern will change to pairing mode
pattern| OFF
Red| Flashing| Zigbee connection lost| OFF
Red| 2 fast flashes| Does not recognize message from meter
(Applies to software version 0.5 and up)| OFF
Red| Flashing every 3 seconds| Lost Zigbee contact (Applies to version 0.5 and
up in software)| OFF
Using the button
ACTION | DESCRIPTION | EXPLANATION |
---|---|---|
**** Press for more than 10 seconds | **** Factory reset | Resets Meter Reader |
to factory default and starts pairing mode
Note: A factory reset unpairs the Meter Reader from your gateway
Eva Meter Reader supports
- Eva Hub
- Homey
- Home Assistant (Zigbee2MQTT)
- Futurehome
Changing the batteries
-
Remove the cover.
-
Remove the old battery and insert a new one (CR123).
Note: The LED light will indicate a startup by alternating between flashing red and blue. The LED light will then flash red until the meter reader has restored communication with the hub. -
Put the cover back on the meter reader.
Debug
DESCRIPTION | POTENTIAL CAUSES | SUGGESTIONS |
---|---|---|
No data from meter reader available | Cabling | Ensure that the cables are |
properly attached
No data from meter reader available| HAN port is not opened for traffic|
Contact your power supplier to open the HAN port traffic
No data from meter reader available, meter reader is offline in app| Lost
contact with the Zigbee network (may be due to the fuse box blocking signals
from the meter reader)| 1. Add powered devices like a smart plug that acts as
a repeater
2.Attach the meter reader on the outside of the fuse box
3. Use an external antenna (WLAN/WIFII antenna that supports 2.4GHz and RP-
SMA connector, can be purchased separately).
---|---|---
The meter reader displays incorrect values| The electricity meter is not
supported| **** Contact your electricity provider and ensure that your
electricity meter follows the OBIS list.
In the box
- Eva Meter Reader
- HAN port connection cable (standard LAN cable with RJ45 connectors)
- 1 CR123A battery
- Security instructions
Important safety information
For indoor use in dry environments only.
- Can be used in temperatures from 0º to 40º C.
- This product is not a toy. Keep out of reach of children.
- The product should not be placed near heat sources or directly in sunlight, as this can cause overheating.
- Use the correct battery type. Using the wrong battery entails a risk of fire and explosion.
- Do not use the device if it has visible damage.
- Dispose of the batteries according to the instructions.
- Failure to follow the recommendations in this manual may be dangerous or cause legal offences. The manufacturer will not be held responsible for any loss or damage.
Appendix
Information on disposal for users of waste electrical & electronic equipment
This symbol on the product and accompanying documents means that used
electrical and electronic equipment (WEEE) should not be mixed with general
household waste. For proper treatment, recovery and recycling, please take
this product to designated collection points where it will be accepted free of
charge. Alternatively, in some countries, you may be able to return your
products to your local retailer upon purchase of an equivalent new product.
Disposing of this product correctly will help save valuable resources and
prevent any potential negative effects on human health and the environment,
which could otherwise arise from inappropriate waste handling. Please contact
your local authority for further details of your nearest designated collection
point. Penalties may be applicable for incorrect disposal of this waste, in
accordance with your national legislation.
Software updates
Software updates can be released by the manufacturer to fix bugs or enhance functionality after the product has been released. Updated software versions released will not impact continued compliance with applicable rules.
Technical specifications
General| IP Class: IP 20 (indoor)
OTA upgradable
---|---
Local Communication| Radio protocol: Zigbee 3.0, HA 2.1
Frequency: 2400-2483,5 MHz (IEEE 802.15.4)
Transmission power: 9dBm
Ratings| Operating temperature: 0 to +55 C
Storage temperature: 0 to +55 C
Operating voltage: DC 3V/42V
Declaration of Conformity
Datek Smart Home AS declares that the equipment described in this document, is in compliance with the essential requirements and other relevant provisions of EU Directive 2014/53/EU. If you require a copy of the original signed DoC, please visit https://hjelp.evasmart.no/hc/no or scan QR code that can be found on the packaging of this product and select documents for your product.
Datek Smart Home AS l www.evasmart.no l +47 913
94 604
Subject to change without notice 2023-11-02_v1
Documents / Resources
| eva
Meter Reader
Smart
[pdf] User Manual
Meter Reader Smart, Reader Smart, Smart
---|---
References
- Eva Smarthus produkter - Eva - Smarthus gjort enkelt
- Eva Smarthus produkter - Eva - Smarthus gjort enkelt
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>