Panasonic EP30006 Massage Lounger Chair Owner’s Manual
- August 15, 2024
- Panasonic
Table of Contents
Panasonic EP30006 Massage Lounger Chair
Product Specifications
- Brand: PANASONIC
- Model: EP30006
- Maximum User Weight: 264 lbs (120 kg)
Product Usage Instructions
Basic precautions should always be followed when using the PANASONIC EP30006 Massage Lounger:
- Always unplug the unit from the electrical outlet immediately after use and before cleaning.
- Avoid obstructing the leg rest while retracting and keep children away from it.
- Do not operate the unit if it has a damaged power cord or plug. Return it to an authorized service center if not working properly.
- Keep power cords away from heated surfaces and do not carry the unit by the power cord.
Operating Precautions
To avoid damaging the chair, follow these precautions:
- Do not exceed the maximum user weight of 264 lbs (120 kg) to prevent damage to the massage mechanism.
- Avoid sitting on or dropping the control panel and be careful not to catch the control panel cord between the armrest and chair back.
- Avoid treating the chair roughly, such as turning it on its side or standing on it.
Frequently Asked Questions
Q: Can children use the PANASONIC EP30006 Massage Lounger?
A: This unit should not be used by children. Always remove the key when not in
use and store it out of reach of children.
Q: What should I do if I hear noise coming from the massager during use?
A: Some noise may be heard due to the structure of the massager, which is
normal. If you experience any unusual noise, contact an authorized service
center for assistance.
This Owner’s Manual is provided and hosted by Appliance Factory Parts.
PANASONIC EP30006 Owner’s Manual
Shop genuine replacement parts for PANASONIC EP30006
Find Your PANASONIC Massage Lounger Parts – Select From 25 Models ——– Manual
continues below ——–
Household Massage Lounger Sillón de Masaje Doméstico
Operating Instructions Instrucciones de Uso
Model No./Nº de Modelo EP30006
Before operating this unit, please read these instructions completely. Antes
de utilizar esta unidad, lea compleatamente estas instrucciones y guárdelas
para referencia futura.
IMPORTANT SAFETY INSTRUCTIONS
Basic precautions should always be followed when using an electrical unit,
including the following. Please ensure that you read all instructions before
using the Household Massage Lounger.
DANGER To reduce the risk of electric shock:
1. Always unplug this unit from the electrical outlet immediately after using
and before cleaning.
WARNING To reduce the risk of burns, fire, electric shock, or injury to
persons:
1. Always insert the power plug all the way into the outlet to reduce the
risk of short-circuit and fire. 2. The unit should never be left unattended
when plugged in. Always unplug the unit when not in use. 3. The unit is not to
be used by people who cannot move or communicate on their own. 4. Only use the
unit for the purpose described in these instructions. 5. Do not stand on the
unit. 6. Do not use any accessories other than those recommended by the
manufacturer. 7. Always return the seat to the upright position and make sure
the legrest is completely retracted. Be careful that
nothing is obstructing the legrest while retracting. Keep children away from
the legrest. 8. Never operate the unit if it has a damaged power cord or plug.
Return the unit to the nearest authorized service
center if it is not working properly, if it has been dropped or damaged, or if
it has been immersed in water. 9. Keep power cords away from heated surfaces.
Do not carry the unit by the power cord. 10.Never block the air openings
during operation and make sure that all air openings are kept free of lint and
hair,
etc.
Do not drop or insert anything into any of the openings of the unit. 11.Do not
use the unit on top of heating appliances, such as electric carpets, etc. Do
not operate the unit under
blanket or pillow. Excessive heating can occur and cause fire, electric shock,
or injury to persons. 12.Do not use the unit in bathrooms or other damp or
humid places as this may cause electric shock or cause the
unit to malfunction. Do not spill water, etc. onto the control panel. 13.Do
not use the unit outdoors. 14.Do not use or operate where aerosol spray
products are being used or where oxygen is being administered. 15.When
unplugging the unit, turn off all controls before removing the plug from power
outlet. Do not use the unit
with a transformer as this may lead to malfunction or electric shock.
16.Connect this unit to a properly grounded outlet only. See Grounding
Instructions.
SAFETY PRECAUTIONS
CAUTION: To avoid the risk of injury:
1. Persons with any of the conditions listed below or who are undergoing
medical treatment or suffer from medical conditions should consult with their
physicians before using the unit: a) Pregnant women, people who are ill, in
poor physical shape. b) People suffering from back, neck, shoulder, or hip
pain. c) People who have a pacemaker, defibrillator, or other personal medical
devices prone to electronic interference. d) People suffering from heart
disease. e) People who are prohibited from receiving massage by a physician
due to thrombosis or aneurism, acute varicose veins, or other circulatory
disorders. f) People with irregular curvatures of the spine.
2. This unit should not be used by children. Remove the key when not in use
and store out of reach of children. 3. Sit down slowly after checking the
position of the massage heads. Never put any part of your body between the
massage heads as the squeezing action of the massage heads may cause injury.
Never put your fingers or feet in the gap between the backrest and seat, the
backrest and the armrest, the seat and cover under the armrest, or the gap
between the legrest and the footrest. Do not place your fingers or any part of
your body in the mechanism below the legrest, or between the legrest and
footrest. 4. Do not use the unit against bare skin. While thin clothing may
increase effectiveness, exposing the skin directly to the massager may
irritate the skin. Do not use the unit while wearing anything hard on your
head like a hair accessory, etc. Do not use the unit for massaging the head,
abdomen, front neck, elbows or knees. Do not use excessively strong massage
action on the back of the neck. 5. When using the body scanning function,
always ensure that the shoulder position is correct. If the shoulder position
is not correct, use the POSITION button to adjust it properly. You can adjust
the shoulder position in this way in the pre-programs, quick massage, self-
program and manual operation. Failure to align the shoulder position correctly
can lead to injury. 6. Do not stretch the back muscles for more than
approximately 15 minutes at a time. To avoid overstretching the muscles which
may result in discomfort, do not use the unit for more than 5 minutes when
first using it. You can gradually increase the duration and strength of the
massage as you become used to it. Do not massage any one point for more than 5
minutes at a time. Excessive massaging can overstimulate the muscles and
nerves and result in an adverse effect. To prevent excessive massaging, do not
use the massager for more than a total of 15 minutes each session. After
approximately 15 minutes, the massage heads will be retracted and stop moving.
The back cushion can be removed if you want to experience a stronger back
massage. Exercise extreme care when you use this mode in order to avoid back
pain or injury. Use only for short periods of time (no more than 15 minutes).
Reinstall the back cushion if you want to restore to normal massage intensity.
7. While using the massager, if you start feeling sick or if the massage seems
painful, stop using it immediately. While using the massager, if the pressure
seems too strong, the movement of the massage heads can be stopped at any time
by pressing the Quick Stop button. 8. Do not go to sleep while using the unit.
Do not use the unit after drinking alcohol. 9. When the seat back is in a
reclined position, do not sit on it or sit with your legs resting on the
headrest. Do not sit on the legrest as the unit may fall over. 10.Do not allow
children or pets to play on or around the unit, especially during operation.
11.Do not unplug the unit or turn it off during operation. Unplug the unit
immediately if there is a power outage. 12.Be sure to start on the gentle
massage program if using the massager for the first time. The shiatsu massage
is stronger and should be enjoyed after one has gotten accustomed to the
chair. 13.Do not allow children to play on this mechanized furniture or
operate the mechanism. Legrest folds down on closing so that a child could
possibly be injured. Always leave in an upright and closed position. Keep
hands and feet clear of mechanism. Only the occupant should operate it.
14.Remove hard objects, such as false fingernails, wristwatches or rings, when
massaging hands or arms. Empty pockets of hard objects when massaging the area
of the seat or thighs. 15.Always raise the back cushion to check that the
fabric of the unit itself has not been ripped before using the unit. Please
also check other areas to ensure that the fabric has not been ripped. No
matter how small the rip, if you find one then immediately stop using the
unit, unplug the power cord and have the unit repaired at an authorized
service center.
OPERATING PRECAUTIONS
WARNING: To avoid damaging the chair, follow these precautions:
1. The chair is designed for a maximum user weight of 264 lbs (120 kg).
Exceeding the maximum weight may cause permanent damage to the massage
mechanism and/or other components of the unit. Any such damage is deemed to be
user abuse and is not covered under the Limited Warranty.
2. Do not sit on or drop the control panel. Do not pull the control panel
cord or the power cord. Be careful not to catch the cord of the control panel
between the armrest and the chair back.
3. Do not treat the chair roughly, such as turning the chair on its side,
turning the chair over or standing on it. 4. Do not treat the covering
roughly.
· Keep sharp or pointed objects away from the covering of the chair. Be
careful not to drop lit ashes, lit cigarettes or matches on the chair.
· Exposure to direct sunlight can cause fading or a change in color of the
covering. 5. If the massager functions abnormally, immediately turn off the
power and have the massager checked by an
authorized service center. 6. Do not repeatedly operate any switch at short
intervals. Such action may cause the switch to malfunction. 7. Some noise may
be heard coming from the massager while in use. This is due to the structure
of the massager
and is normal. 8. Make sure there are no obstacles behind the chair before
reclining it. The chair can be reclined to a maximum
angle of 170°. If the back hits a wall or pillar, the chair may malfunction.
Be sure to have ample space behind the chair. Recline the chair slowly in
order to avoid contact with an obstacle. 9. When excessive pressure is applied
to the massage heads, they may stop moving for safety. When moving the heads
up from the lowered position, one’s body weight may stop the heads’ movement.
In such a case, slightly raise your body and allow the massage heads to move
up. 10.After each massage, slide the power switch, which is located on the
right side of the chair, to the “off” position and turn its lock switch to the
“lock” position. 11.Do not sit on the chair with wet body or hair. 12.The unit
must not be used in “wet rooms” (sauna, swimming pool) or outdoors. 13.Do not
attempt to open or disassemble any part of the unit. Only use an authorized
Panasonic servicer to fix your unit. Call
1-800-338-0552 to find the servicer
nearest to you.
3
GROUNDING INSTRUCTIONS
This product must be grounded. If it should malfunction or break down,
grounding provides a path of least resistance for electric current to reduce
the risk of electric shock. This product is equipped with a cord having an
equipment-grounding conductor and a grounding plug. The plug must be plugged
into an appropriate outlet that is properly installed and grounded in
accordance with all local codes and ordinances.
DANGER
Improper connection of the equipment-grounding conductor can result in a risk
of electric shock. Check with a qualified electrician or serviceman if you are
in doubt as to whether the product is properly grounded. Do not modify the
plug provided with the product if it will not fit the outlet, have a proper
outlet installed by a qualified electrician.
This product is for use on a nominal 120-volt circuit and has a grounding plug
that looks like the plug illustrated in Figure A. Make sure that the product
is connected to an outlet having the same configuration as the plug. No
adapter should be used with this product.
Figure A
GROUNDING PIN
GROUNDED OUTLET
GROUNDED OUTLET BOX
4
Part names and functions
Main unit
Front
1 Legrest 2 Leg/Sole massage section
· Includes air massage function
Sole Reflexology Plates · Removable · Position adjustment possible 3 Legrest
Slide Lever · Extendable length to approx. 5 in.
(12 cm) 4 Control Panel
See page 7 to 8
5 Seat/Thigh Side Massage section
Seat/Thigh Soft Massage Plates (integrated) · Position adjustment possible 6
Retracted position of massage heads 7 Back Cushion 8 Pillow 9 Backrest ·
Includes integrated massage
heads 10 Seat
· Includes integrated air massage function
11 Armrest
12 Hand/Arm massage section · Includes integrated air massage function
13 Control Panel Stand Covers · On both the left and right sides
14 Outer Shoulder massage section · Includes integrated air massage function
Shoulder Plates · Removable · Position adjustment possible
5
Back
15
16 17 18 13
19 20 21
22
23
15 Back Cover 16 Control Panel Holder 17 Child Safety Decal 18 Control Panel Stand 19 Power Plug 20 Power Cord 21 Safety Precaution Label 22 Wheels
23 Power Supply Box Lock Switch
Power Switch
Lock Switch Key Lock Switch Key Tag · For preventing children from
swallowing it by accident
6
Control Panel
Cover closed
13
Cover open
14
15
17
16
1 Off/On
2 Quick Stop · Press this button to stop the massage immediately.
3 User Memory · See page 39 to 41
4 Program Selection · See page 18
5 Ottoman Angle Adjustment · See page 35
6 Reclining Angle Adjustment · See page 35
7 Display · This illustration simulates when all lights are illuminated. · See
page 8
8 Voice Guidance Volume · See page 37
9 Ultra Knead · “Ultra Knead” is the name of the massage actions. · See page
26 to 27
10 Repeat · See page 27
11 Massage Style Selection · See page 27
12 Position · See page 28
13 Back Intensity Adjustment · Adjustment of the massage heads strength · See
page 28
14 Stretch · See page 34
15 Air Massage Controls · Selection of the areas to be air massaged · See page
30
16 Self-Program/Manual Operation Controls · See page 22 to 23
17 Manual Adjustment Controls · See page 24 to 26
7
Display
- This illustration simulates when all lights are illuminated.
1 Voice Guidance Volume Display · See page 37 Off Soft Medium Loud
2 Time Remaining Display (During massage)
(After finishing massage)
3 Ultra Knead/Repeat Display · See page 27 (Ultra knead)
(Repeat)
4 User Memory Display · Illuminated when operating the User Memory function ·
See page 39 to 41
5 Pressure Display · Displays the pressure applied by the massage heads
6 Massage Style Display · Displays the current massage style
Thumb-like action
Palm-like action Fist-like action
7 Self-Program Setting Display · See page 22 to 23
8 Manual Upper Body Massage Display · See page 24 to 26
9 Air Intensity Display · See page 30
10 Stretch Display · Indicates whether the leg stretch or the arm is on or off
On: Turned on
Off: Turned off
In operation: flashing
11 Massage Area Display · Flashes to indicate areas currently being massaged ·
In the Massage Area Display, positions are estimated. Therefore, there may be
some differences between the actual sensation and the display.
12 Back Intensity/Speed Display · Intensity and speed of the massage heads are
displayed. · The speed is displayed only in the manual operation.
13 Manual Upper Body Complex Operation Display · Indicates optional operations
added to manual upper body operation · See page 25
TAP 1 TAP 2 REGIONAL ROLL AUTO WIDTH
8
Setting up the massage lounger
1 Where to use the unit Ensure there is adequate space to recline.
Keep at least 4″ (10 cm) away from the wall.
Caution
· Do not use the unit in areas with high humidity, such as the bathroom,
because this can lead to electric shock or other accidents.
· Place the unit on a totally flat surface. Failure to do so may result in the
unit tipping over.
Approx. 77″ (195 cm)
Width approx. 33″ (84 cm) Approx. 12″ (30 cm)
Approx. 14″ (35 cm)
· Do not expose the massage lounger to direct sunlight or high
temperatures, such as in front of a heater, etc., as this can cause discoloration or hardening of the synthetic leather.
· Place the unit on a mat to prevent floor damage. · When placing a mat under the unit, the size of the mat should be
Mat
sufficient (at least 47 × 28 in. (120 × 70 cm)) to cover the areas
where the unit touches and where the legrest could touch the
floor, as shown in the diagram on the right.
· Install the unit near a power outlet.
Area where legrest could touch the floor
Area where unit touches the floor
2 Removing everything from the box and installing the unit · Use care to
prevent lower back and other injuries that could occur when lifting this heavy
object (approx. 176 bs. (80 kg)). (The unit must be carried by two persons.) ·
When using the wheels to move the unit, place a mat on the floor to protect
the floor surface.
To put the unit down on the floor
· Put the unit down slowly and carefully watch your step. · Put down the
legrest by holding it with your hands until it has been set on the floor
completely. If you release your hands
before the legrest is fully extended, the legrest will forcefully return to
the initial position.
Fabric Section
Hold the cloth section on the underside
Place your fingers in the groove
Groove
Legrest
Back cover
Mat
9
Confirm that the main unit and the accessories are in the box.
Main unit Width: Approx. 27″ (68 cm)
Height: Approx. 26″ (66 cm)
· Armrests (Right/Left)
Length: Approx. 63″ (160 cm)
Accessories · Pillow
Left/Right indication
· Control Panel Stand
Control panel holder
Fixing screw
Clip
Air plug
· Control Panel Stand Covers
Small holes on the inside fabric are an intentional part of the functional design.
· Allen Key — 1
· Sole Reflexology Plates
(Cross-section) 0.2″ (4 mm)
This is installed on the sole massage section prior to leaving the factory.
· Shoulder Plates
· Attachment Screws (M6 × 16) — 7
· Lock Switch Keys — 2 One of the lock switch keys has been inserted in the lock switch prior to leaving the factory. The other lock switch key is a spare to be stored for safekeeping out of the reach of children.
Documents including the Operating Instructions
· Operating Instructions · Child Safety Instructions (Yellow brochure) · How
to transport and move (Yellow brochure) · Notes for body scanning (Pink
brochure) · Quick Start Manual
Do not remove this tag.
10
Assembly
1 Attaching the armrests (On both the right and left sides)
1. Insert the armrest into the unit. · Be careful to avoid pinching your
fingers.
(1) Align the position
2. Fasten the armrest with the Attachment
attachment screws.
Screw
Set the two attachment screws in place by hand first and then tighten firmly with the allen key.
Use this Screw Attachment Screw (M6 × 16)
× 4
Outside
Make sure that the seat surface is not damaged.
Groove Armrest
Right/Left indication
Pipe
Turn screws clockwise to
tighten.
(2) Fasten the armrest with the attachment screws. Main unit
Attachment Screw
Allen key
Inside
2 Connecting the air plugs (On both the right and left sides) Insert the air plugs into the unit.
Push on the air plugs until you hear it click into place.
Air plug
11
3 Attaching the control panel stand to the right or left side panel of the unit (Diagram shows attachment to right armrest.)
1. Insert the attachment screw into the lower hole first and then tighten
lightly by hand.
2. Securing the stand with the attachment screws. Tighten the two screws for
the remaining two holes lightly by hand and then tighten firmly with the allen
key.
The position of the control panel when seated can be selected by choosing the appropriate hole for the screw.
Near
Approx. 20°
Far
Control panel stand
1 Insert the attachment screw in either hole and then tighten. Attachment
screw
Use this screw Attachment Screw (M6 × 16)
× 3
2
Allen key
To attach the control panel stand using the attachment
screws, tighten the screws level with the holes as
shown in the figure below.
If the screws are tightened at an angle, the hole may
become deformed and the screws may become stuck in
the middle.
Control panel
Control panel stand
stand
Hole
Attachment screw Hole
Allen key
Tighten the screws level with the holes.
Attachment screw
Allen key
Do not tighten the screw at an angle with the hole.
4 Attaching the control panel stand covers (On both the right and left sides)
The method for attaching the covers is the same for both sides. The diagram
shows the side where the control panel stand is attached.
Cover for Side WITH Cover for Side WITHOUT Control Panel Stand Control Panel Stand
1. Insert the top tabs on the cover into the bottom notches on the armrest.
Notches
2. Insert the bottom tabs into the notches on the armrest.
Bottom tabs
Top tabs
Control panel stand cover
Notches
Push the cover until you hear it click.
12
When removing the control panel stand cover
1. Insert the head of a flat-tip screwdriver in the gap under the mark (O).
2. Push the bottom tab of the cover up to lift the cover. 3. Perform the same
procedures as 1 and 2 above for
the other gap. 4. Pull the cover up diagonally.
· Performing this procedure with the allen key or a Phillips screwdriver could
damage the unit.
Gap 2 1
2
5 Raising the backrest to the upright position
1. Insert the power plug into the power outlet.
2. Confirm the key lock is set to the “open” position.
3. Confirm the power switch is set to the “on” position.
4. Press the
button on the control panel
twice.
The backrest will rise to the upright position
automatically.
Flat-tip screwdriver (Not included in the standard configuration)
13
Moving the control panel cord to the left side (when control panel stand is on left side)
1. Press the button on the control panel to turn on the power.
Legrest
2. Press the
button on the control panel and hold until the legrest
has risen far as it will go. Continue pressing until a “beep-beep-beep” sound is heard.
3. Remove the control panel cord from the cord-holder groove.
4. Move the control panel cord under the legrest to the left side.
5. Fasten the control panel cord at two points in the cord-holder groove.
Control Panel Cord
Cord-Holder Groove Push in
Control Panel Cord
6 Placing the control panel into the control panel stand
1. Fit the groove on the side of the control panel to the projection on the
inside of the holder.
Backside of the control panel
Projection on the inside of the holder
Groove on the control panel
14
2. Fasten the control panel cord using the clip. Clip
Lift the control panel to remove.
Fasten the cord so that the Control panel cord portion under the clip is
not slack.
7 Inserting the shoulder plate
1. Insert the plate into the pocket on the outer shoulder massage unit. ·
Grasp the pocket and pull it slightly to expand the opening, so that the plate
can be inserted easily.
Shoulder plate
2. Slide the inserted plate for the outer shoulder to the inside (recommended position). · The up/down and in/out positions of the plate can be adjusted. The recommended position is when the plate is inserted into the deepest position and then moved to the most inside position. · Grasp the pocket opening with one hand, hold the plate with the other hand, and move it into the deepest position.
8 Attaching the pillow
1. Attach the pillow to the velcro fasteners. · See page 38 for a guide to
the position of the pillow
Pillow
Velcro fasteners
Proper plate for each outer shoulder
(For the right shoulder)
(For the left shoulder)
15
Before sitting down
Check the following before using the unit
1 Check the surrounding area Make sure there are no objects, people, or pets
in the vicinity of the unit.
2 Check the power cord and the power plug
Warning
· Remove dust from the power plug periodically. Failure to observe this
precaution may result in defective insulation of the cord due to moisture.
Clean dust from the cord using a dry cloth.
· Do not damage the power cord and the power plug. (Do not damage, expose to
heat sources, bend, twist, pull forcibly, bundle or place heavy objects on the
cord.) Using a damaged power cord and/or the power plug may result in electric
shocks, short circuits, or fires. Ask your sales dealer to repair the power
cord and/or the power plug, or contact a customer service center.
3 Switching on the power supply
1. Insert the power plug into an electrical outlet.
2. Turn the lock switch key to the “open” position.
3. Slide the power switch to the “on” position.
Warning
· Insert the power plug firmly until it stops completely. Failure to observe
this precaution may result in electric shocks or fires due to heat generation.
· Do not exceed the rated values of the plug and the wiring or use any voltage
other than the rated voltage. (The unit cannot be used abroad or used with a
transformer.) Failure to observe this precaution may result in electric
shocks, malfunctioning or fires due to heat generation.
· Do not handle the power plug with wet hands. Doing so may result in electric
shocks.
4 Check the unit
1. Make sure there are no tears or rips in the fabric.
Warning
· Lift the back cushion and make sure the fabric on the backrest is not torn.
(Even if it is torn very slightly, stop using the unit immediately, remove the
power plug, and request repairs.) Using the unit with the fabric torn may
result in injury or electric shocks.
Check
Fabric Check Backrest
Back cushion
16
2. Make sure there is no foreign objects on the chair.
Caution
· Sit on the unit after confirming there is no foreign matter between the
parts of the unit. (Check for foreign objects on the backrest, leg/sole
massage section, hand/arm massage section, seat/thigh side massage section, or
the outer shoulder massage section.) Failure to observe this precaution may
result in accident or injury.
Outer shoulder massage section
Hand/Arm massage section
Seat/Thigh side massage section
Leg/Sole massage section
3. Make sure the massage heads are in the retracted position.
Caution
· Sit on the unit after confirming the massage heads are in the retracted
position. Failure to observe this precaution may result in accident or injury.
3. Retracted position
When the massage heads are not in the retracted position
Press the button twice to return the massage heads to the retracted position.
4. Make sure the legrest is in the fully lowered position.
Legrest slide lever
Caution
· Do not stand on the legrest or place any object on it when the legrest is
not in the fully lowered position. Failure to observe this precaution may
result in accident or injury from the foot part of the legrest turning or the
unit tipping over.
4. Check
To lower the legrest Make sure the legrest has fully returned to the original position by pulling the legrest slide lever, and then press the button twice.
17
Program Massages
Pre-Program
Quick Massage
1 Press the button to turn on the power. · The power will turn off automatically if the massage does not start within 3 minutes after turning on the power.
2 Press one of the flashing buttons ( program.
Pre-Program and Quick Massage Characteristics (Upper Body) · See page 21 for
an overview of the respective programs.
SHIATSU: Uses mainly shiatsu massage to loosen up deep-seated knots of
tension. Recommended for those with severe stiffness and tension.
DEEP: Uses mainly kneading to manipulate and loosen muscles. Recommended for
those with mild stiffness and tension.
SWEDISH: Uses mainly Swedish massage to gently invigorate and promote
circulation. Recommended for those experiencing fatigue and weariness.
) to select the
STRETCH: Uses mainly compression to slowly stretch muscles and joints.
Recommended when a refreshing stretch is desired QUICK: Covers all areas using
a variety of massage actions in a span of just 5 minutes.
18
1. Body scanning will commence when the program is selected. The body scanning will properly detect height ranges between approximately 4’7″ and 6’8″ (140 and 185 cm).
Sit as far back in the seat as possible with your head on the pillow.
The unit will automatically recline to the correct measuring position.
Correct Massage Position
Reclined approx. 12°
1
2 3 4
1 NECK (Neck) 2 SHOULDER (Shoulder) 3 MIDDLE (Back) 4 LOWER (Lower back)
Adjust the pillow height so that the bottom edge of the pillow is at ear level. See page 38.
Raised approx. 55°
2. Approximately 30 seconds after the body scanning starts, the massage heads slowly lower to the shoulder position, and a soft tapping action begins to determine your shoulder height.
Massage Head
Tapping action
Keep your head on the pillow until the soft tapping begins. Lifting your head
from the pillow will result in incorrect determination of the shoulder
position. 3. Confirm that the shoulder position has been correctly determined
according to the position of the soft tapping.
Too high Correct position of the massage head (The point where the tapping
action should be felt.) Too low
· When the shoulder position is incorrect, adjust the shoulder position while
the soft tapping is in progress (for approximately 15 seconds), and use the
POSITION button to move the massage heads up or down.
A single press of the button will raise or lower the massage heads
approximately 0.5″ (1.2 cm).
4. The massage will start after body scanning is complete. The legrest height
will adjust automatically based on the body scanning results. The soles of the
feet should be touching the footrest wells. You may still adjust the length of
the legrest with the lever on the right side of the seat (see next page). You
may also further adjust the height of the ottoman electronically (see page
35).
19
When the massage starts
Adjust the length of the legrest to accommodate the position of the backs of
your calves or knees to fit into the legrest wells.
For the hand/arm massage, lift the armrest up and insert your arm.
Armrest
Insert your hand with fingers extended.
Push the legrest with the sole of your foot while pulling the legrest slide
lever.
Caution
· Remove hard objects, such as false fingernails, wristwatches, or rings when
massaging the hands or arms. · Remove hard objects from the pockets of your
trousers when massaging seat/thigh.
Failure to do so may result in injury.
During a massage
· To change off/on for “LEG/FOOT,” “SEAT,” “HAND/ARM,” or “SHOULDER” and
adjust its intensity, see page 30. · If you want to turn the stretch massage
off/on, see page 34. · If you want to adjust the legrest, see page 35 and 36.
· If you want to adjust the intensity and position of the massage on the upper
body using the massage heads, see page 27
and 28. · If you want to adjust the reclining angle, see page 35. · If you
want to use the “ULTRA KNEAD” function or “REPEAT” function, or change the
massage style, see page 27. · If you want to finish a massage, see page 42 and
43.
20
Overview of the Pre-Program and Quick Massage (Upper Body)
Shiatsu Program (I)
- Ultra knead/ 2) Ultra knead/ 3) Ultra knead/ 4) Ultra knead/ 5) Ultra knead/ 6) Ultra knead/ 7) Finishing Shiatsu/Grasp Shiatsu on Back/ Shiatsu/Grasp Shiatsu on Back/ Shiatsu/Grasp Kneading on Touches on Neck/Shoulder Lower back on Neck/Shoulder Lower back on Neck/Shoulder Back/Lower back
Deep Program (II)
-
Ultra knead/ 2) Ultra knead/ 3) Ultra knead/ 4) Ultra knead/ 5) Ultra knead/ 6) Ultra knead/ Kneading/Grasp Kneading of Kneading/Grasp Kneading of Kneading/Grasp Kneading of of neck/Shoulder Back/Lower back of neck/Shoulder Back/Lower back of neck/Shoulder Lower back
-
Ultra knead/ 8) Finishing Kneading/Grasp Touches of Shoulder
Swedish Program (III)
-
Ultra knead/ 2) Swedish on Swedish from Neck/Shoulder Neck to Lower back
-
Ultra knead/ 4) Swedish on Swedish on Neck/Shoulder Back/Lower back
-
Ultra knead/ 6) Swedish from 7) Finishing Swedish on Neck to Lower Touches Back/Lower back back
Stretch Program (IV)
-
Kneading from 2) Narrow Neck to Lower Pressing back
-
Ultra knead from Neck to Lower back
-
Narrow Pressing/ Stretching
-
Ultra knead/ 6) Narrow Pressing on Stretching Back/Lower back
-
Swedish/ 8) Finishing Stretching on Touches Back/Lower back
Quick Program (V)
- Ultra knead/ 2) Ultra knead/ 3) Finishing Shiatsu/Grasp Swedish on Touches on Neck/Shoulder Back/Lower back
21
Creating Self-Programs
Self-Program
Self-Program
The Self-Program allows you to create a massage where you determine the time
and intensity in neck, shoulders, back, and lower back by selecting from
levels 0 (no massage) to 3 (longest and most intense).
1 Press the button to turn on the power. · The power will turn off automatically if no operation is executed for 3 minutes without performing massage.
2 Open the right cover and press the
button.
The self-program setting display on the top right of the display will flash.
Display
22
3 Set the time and intensity for the neck, shoulder, back, and lower back,
respectively (
).
· The level shifts sequentially whenever the button is pressed.
Display
How to shift the level
· Press the
button to shift the levels for “NECK,” “SHOULDER,” “MIDDLE,” and “LOWER” by one up/down at the same
time.
· 3 bars represents more time than one bar.
· If all areas are 3 bars, then both time will be equally long and the massage will be strong in all areas.
· If all areas are just one bar, then massage length will be the same, and intensity will be lighter.
4 Press the
button to start the program.
The massage will start after the body scanning.
To change the time and intensity in the middle of a massage
3 4 Set the condition again with Steps and .
· Press the
3 button within approximately 30 seconds after resetting in Step , otherwise the reset will be cancelled
automatically.
Setting the Time and Intensity
· In the Self-Program, the actions and time for the respective body parts will
be set according to the settings picked by the user. Fewer bars means both
less time and less strength. If you don’t want a massage at all in an area,
set the bars to “0”.
Massage Sequence
· The massage starts in the area with the highest numbers of bars selected,
and moves successively from highest to lowest.
· If the levels of fatigue are the same, the massage will follow the sequence
of “NECK,” “SHOULDER,” “MIDDLE,” and then “LOWER.”
Massage actions for the respective level of fatigue
Stronger massage mainly Shiatsu
Massage at an intermediate level, mainly Kneading
Softer massage mainly Swedish
No massage for this part
During a massage
· To change off/on for “LEG/FOOT,” “SEAT,” “HAND/ARM,” or “SHOULDER” and
adjust its intensity, see page 30. · If you want to turn the stretch massage
off/on, see page 34. · If you want to adjust the legrest, see page 35 and 36.
· If you want to adjust the intensity and position of the massage on the upper
body using the massage heads, see page 27
and 28. · If you want to adjust the reclining angle, see page 35. · If you
want to use the “ULTRA KNEAD” function or “REPEAT” function, or change the
massage style, see page 27. · If you want to finish a massage, see page 42 and
43.
23
Manual Selection Massages
Manual Operation
Manual Operation
Manual Operation provides a massage of your favorite body part with your
favorite action by selecting neck, shoulder, back, or lower back and an
action.
1 Press the button to turn on the power. · The power will turn off automatically if no operation is executed for 3 minutes without performing massage.
2 Open the right cover and press the
button.
The manual setting display on the top right of the display will flash.
Display
24
3 Select the location you want to massage (
).
· You can select an action combined with “FULL ROLL” by pressing the
button.
Display
4 Select the massage action (
).
By pushing on the body part again, the massage action will toggle down from ultra knead to tap. Shoulder massage will toggle all the way to grasp.
5 Press the
button to start the action.
The massage will start after the body scanning.
Body scanning for Manual Operation
For the Neck/Shoulder: Normal body scanning. Back/Lower back: Simple body
scanning. (The massage heads will not come up to the shoulder position.)
To change an action in the middle of a massage
3 5 Select your favorite one again in Steps to .
· Press the
3 button within approximately 30 seconds after reselecting an action in Step , otherwise the reselection will
be cancelled automatically.
Adding tapping, regional rolling, auto width
Press the following buttons (
).
· These actions cannot be selected independently. · These actions cannot be added to “GRASP”.
25
Description of Massage action (The figures are images of the respective operations.)
ULTRA KNEAD
Kneading action at small points.
SHIATSU
Action compressing muscle knots vertically.
KNEAD Deep kneading action.
SWEDISH
Action of rubbing gently across a wide area.
STRETCH Slow stretching action.
TAP
Tapping action for right and left alternately.
GRASP
Action like grasping the shoulder.
FULL ROLL
Action stretching the body along the backbone.
For additional operations
The following variations can be added to the actions listed above.
TAP 1: Add tapping actions where the speed will increase and decrease
gradually.
REGIONAL ROLL: Adding actions that move partly in the vertical direction.
TAP 2: Adding tapping where the speed is fast and slow reciprocally.
AUTO WIDTH: Adding actions that move in the horizontal direction in 1.5″ (3.8
cm).
During a massage
· To change off/on for “LEG/FOOT,” “SEAT,” “HAND/ARM,” or “SHOULDER” and
adjust its intensity, see page 30. · If you want to turn the stretch massage
off/on, see page 34. · If you want to adjust the legrest, see page 35 and 36.
· If you want to adjust the intensity and position of the massage on the upper
body using the massage heads, see page 27
and 28. · If you want to adjust the reclining angle, see page 35. · If you
want to change the massage style, see page 27. · If you want to finish a
massage, see page 42 and 43.
26
Adjustments During a Massage
ULTRA KNEAD BACK INTENSITY
REPEAT POSITION
STYLE
SPEED
Changing the program
Only for the Pre-Program, Quick Massage, and Self-Program
Ultra knead function · When the button is pressed, the Ultra knead action will
be repeated on
that point for a certain period. For details of the Ultra knead action, see
page 26.
Repeat function · The action at the time when the button is pressed will be
repeated. · For example, 15 seconds of shoulder kneading will become
30 seconds of kneading when the repeat function is pressed.
Display
This will be turned on when the action is repeated.
This will be turned on when the action is repeated.
Changing the massage style
For details about the massage style, see page 29.
For the Pre-Program, Quick Massage, and Self-Program · It is possible to use
the selected massage style only.
(If the STYLE button is not pressed, the massage style will change
automatically during the massage.) · Press the same STYLE button again to
toggle that type of massage off.
For Manual Operation · It is possible to use the selected massage style.
(The preset massage styles are initially set for the respective actions.)
Note: “Grasp” cannot be selected as a manual massage style, except in
the shoulder area.
Display
Only the selected massage style button will turn on.
Only the selected massage style button will turn on.
Adjusting the speed
For the Pre-Program, Quick Massage, and Self-Program · The speed cannot be
adjusted. For Manual Operation · The speed can be adjusted in 5 steps.
Display Speed 1 Speed 2 Speed 3 Speed 4 Speed 5
27
Adjusting the intensity
The intensity may not change immediately if the button is pressed in the
middle of an action.
For the Pre-Program, Quick Massage, and Self-Program · The intensity can be adjusted in 3 steps.
Display
Light
Medium Strong
For Manual Operation · Adjustment is possible until a “beep-beep-beep” sound
indicating the limit point is heard. The adjustable range varies with the
actions and body parts. See page 29
Intensity 1 Intensity 2 Intensity 3 Intensity 4 Intensity 5 or more
Adjusting the position
The position may not change immediately if the button is pressed in the middle
of an action.
For the Pre-Program, Quick Massage, and Self-Program · Fine adjustment is
possible.
(Maximum numbers of adjustment) At some positions, it is impossible to adjust
twice.
(Adjustable range) Approx. 0.9″ (2.4 cm)
Twice
Approx. 0.5″ (1.2 cm)
Twice
Twice
Twice
Approx. 0.5″ (1.2 cm)
Approx. 0.3″ (0.8 cm)
Approx. 0.3″ (0.8 cm)
Approx. 0.2″ (0.4 cm)
Approx. 0.9″ (2.4 cm)
For Manual Operation · Adjustment is possible until a “beep-beep-beep” sound
indicating the limit point is heard.
The adjustable range varies with the actions and body parts. See page 29 · For
adjustment in the vertical direction, the position will move continuously as
long as you press the button.
28
Details about the massage style
Thumb-like action
· Massage head movement is firm with only the upper massage heads moving so that they act like two thumbs. This is shiatsu style massage of acupoints.
Palm-like action
Approx. 20°
· The massage heads remain spread apart, forming a palm which gently presses against the back. There is a gentle 20 degree pivot, which softens the massage feel.
Fist-like action
Approx. 20°
· Upper and lower massage heads pull together to form a “fist”, which presses softly on the back. These heads will also pivot up to 20 degrees to soften the direct massage strength.
Width Adjustment Limits
Adjustment of range of intensity
· For a massage of the upper body, the maximum depth and intensity of the
massage heads are limited for safety reasons.
· The intensity at Range (B) or (C) in the right figure can be set to stronger
than Range (A). Adjustment is possible until a “beep-beep-beep” indication is
sounded.
Range (A) Range (B)
Range (C)
Range that can be massaged on the upper body
Approx. 3″ (7 cm)
For “FULL ROLL” (Including actions combined with “FULL ROLL”)
Approx. 8″ (21 cm)
Approx. 3″ (7 cm)
Approx. 7″ (18 cm)
Approx. 30″ (76 cm) Approx. 30″ (76 cm)
29
Air Massage Adjustments
Air Massage
· When a pre-program and quick massage are selected, the air massage
for arm, seat, shoulder, leg/foot are all automatically turned on.
Seat/Thigh
· When Self-Program and Manual Operation are selected, the air massage
for all parts is turned off.
1 Open the left cover.
Outer shoulder Hand/Arm
2 Press the ,
, , button to turn
each off or on.
To execute the air massage only
After turning on the power by pressing the button, press the ,
,
, or
button.
· The power will turn off automatically if no operation is executed for 3 minutes.
Leg/Sole
Display It is possible to confirm whether the air massage is turned on or off
on the display. (The lamp is turned on: [ON], the lamp is turned off: [OFF])
Outer shoulder Hand/Arm
Adjusting the intensity
Press the
button to adjust the intensity.
· The intensity can be adjusted in 5 steps.
Leg/ Sole
Seat/Thigh
Air intensity level display
30
Adjusting the Legrest length
Adjust the legrest so that your feet fit snugly.
For a person who is smaller: · If the legrest is raised up, the fit with your
leg and sole of your
foot will be better.
Press the
button.
For a person who is tall: · Push the legrest out by pulling back on the legrest slide lever.
· Tall people will have a better fit by lowering the legrest somewhat.
Press the button.
Pull the legrest slide lever.
Push with the soles of your feet to slide the legrest out.
Raise the legs slightly and the legrest returns.
For those who are very tall, or for those who want a complete calf massage, the ottoman pivots down around the ankle.
Sole section
For the foot reflexology plate
The plate is removable. Opening
To insert the plate Each plate is different slightly. Be sure to follow the pictures below to insert correctly.
For the left foot
Projections are on the upper side.
For the right foot Toe
Heel
31
Arm Massage
Caution
· Remove hard objects, such as false fingernails, wristwatches, or rings when
massaging the hands or arms. Failure to do so may result in injury.
Position the forearm and hand at the center of the armrest.
Center of the armrest
Insert the hand all the way inside.
· Raise the backrest if any difficulty is experienced when positioning the hand and forearm.
How to use the hand/arm massage
1. Lift the hand/arm massage section up.
2. Insert the hand with fingers extended.
32
Outer Shoulder Massage
The outer shoulder massage provides reflexology on muscles knots on the outer
side of the shoulder blades. The outer shoulder section of the backrest unit
moves inward using air pressure to gently massage these muscles.
Target area for massage between armpits and shoulder blades on the outside of the shoulder.
Adjustments for the Shoulder Massage
Problem
Solution
A good massage cannot be obtained in the outer shoulder. · The massage is too
strong or is hitting
your shoulder bones. · The massage plate is not contacting in
the right spot if you are small in stature.
Adjust the position of the plate until it feels right. · By sitting deeply in
the seat, it is easier to have
good positioning. If you cannot find the ideal position even though you are
deep in the seat, add a pillow or cushion on top of the seat to raise you up.
The plate contacts the pillow.
Adjust the pillow to the proper position. See page 38. When the pillow contacts the outer shoulder even if the position has been adjusted properly, remove the pillow or put a cushion on the seat so that the pillow comes above the outer shoulder massage.
You don’t like a massage using the plate.
Use the unit after removing the plate for the outer shoulder from the pocket.
Adjustments for the seat/thigh massage
Adjust the seat/thigh soft massage plate which is built into the fabric to
your favorite position. It is effective for this to be pushing in on your hip
joint and where you leg meets your hip.
Seat/thigh soft massage plate
33
Using the stretch massage
Warning
· Make sure there are no people or pets behind the unit when the arm stretch
function is turned “on.” Failure to observe this precaution may result in
accident or injury.
Caution
· Do not use with any pre-existing condition of shoulder injury. Doing so may
result in injury.
· When Pre-Program and Quick Massage are selected, the leg stretch is turned
on and the arm stretch is turned off, respectively. · When Self-Program and
Manual Operation are selected, the stretch massage for all parts is turned
off.
1 Open the left cover.
2 Press the or
buttons to turn the functions off or on.
To execute the stretch massage only
After turning on the power by pressing the button,
press the
(stretch legs) or
(stretch
arm) buttons.
· The power will turn off automatically if no operation is executed for 3
minutes.
Display The display will indicate if the stretch function is turned on or off.
(The lamp is turned on: [ON], the lamp is turned off: [OFF])
Arm stretch Leg stretch
Operations of the leg stretch
1. After grasping the legs with air, the legs are stretched as the legrest is lowered approximately 10 degrees from the massage position.
2. Once the legrest returns to the original 3. When the operation is complete, the
angle, the legrest is then lowered
legrest will return to the angle at the
approximately 30 degrees to stretch
time before the operation.
the legs further.
Lowered by approximately 10 degrees
Lowered by approximately 30 degrees
Operations of the arm stretch
1. The backrest will come fully up. 2. After the backrest reclines
One arm will inflate to firmly secure approximately 20 degrees to stretch
the arm/hand in place.
the arm, the backrest will come back
up 5 degrees.
3. Then, the backrest will recline approximately 10 degrees to stretch the shoulders and arms further. When the operation is complete, the backrest will return to the angle at the time before the operation.
34
Ottoman and Backrest height adjustment
Adjusting the reclining angle and the angle of the legrest
1 Press the button to turn on the power.
2 Press the
or
button to adjust the angle.
· Movement will continue until a “beep-beep-beep” sound is heard if the buttons are held down. · The legrest will start to move shortly after the backrest.
Approx. 120°
Approx. 85°
Approx. 0°
Approx. 170°
If the backrest reclines to an angle where you cannot touch the buttons on the
control panel from the seat, hold the control panel in your hand.
35
Extending out the legrest
1 Slide the legrest to your favorite position by pulling the legrest slide
lever. (The legrest will slide approximately 5″ (12 cm).)
Pull the legrest slide lever back. Push with soles of feet and the legrest
slides out.
Raise legs slightly and legrest returns.
2 Release the legrest slide lever when it reaches your favorite position.
Legrest slide lever
36
Adjusting the voice guidance volume
Press the
button to adjust the volume.
Press the button to shift the volume level by one up/down.
Display
Volume
“Off”
The single beep (when a button is pressed) and the triple beep (when the
adjustable setting limit is reached) will always be audible.
“Soft”
“Medium” Default Setting
“Loud”
37
Adjusting the control panel stand and pillow
Adjusting the control panel stand
The direction of the pivoting stand can be adjusted.
Front/Back
Ball joint
Left/Right
Adjusting the pillow for correct height during a massage
1. Remove the pillow.
2. Adjust the height of the pillow so that the 3. Attach the pillow on the velcro
bottom edge is at ear level.
fasteners.
· If positioned too low, the pillow may interfere with a massage of the area around the neck.
Pillow
Lower edge of the pillow
Ear level
Pillow
Velcro fasteners
· When the reclining angle changes, the position of the pillow may shift. In that case, adjust the position again.
38
Advanced user memory function
The user memory function retains the adjustments for a massage, such as
“REPEAT” function or “BACK INTENSITY,” so that the massage will start with the
saved settings.
Saving the user program settings
· See page 40 for the settings that can be saved.
After completing the massage, or when the massage is stopped by pressing the ,
the
buttons will flash and the unit ready to save any settings that changed during the
massage.
1 Press the button for the program settings that you want to save while the buttons flash (for approximately 15 seconds).
The program settings have been saved when the button you pressed and the user memory display
turn on.
When the selected button starts flashing quickly
Other settings are already saved. To update with new program settings, press
the same button again. · To maintain the saved programs, press a different
button. · The operation must be executed within approximately 15 seconds after
the button starts flashing quickly.
When you want to use your saved massage settings
1 Press the button to turn on the power. · The power will turn off automatically if no operation is executed for 3 minutes without performing massage.
2 Press the
button used to save your settings.
The user memory display
turns on.
3 Select from Pre-Program, Quick Massage, Self-Program, or Manual Operation.
· Massage starts without pressing the
button.
· It is also possible to change the settings. In that case, press
button after the settings are changed.
4 The massage will start after body scanning is completed.
39
Settings that can be saved
The latest settings entered by the user during programs or manual operation
will be saved.
For Pre-Program, Quick Massage, and Self-Program
· Settings other than the massage style will be saved as common settings.
Leg stretch settings Air massage settings
Self-program levels
Ultra Knead/Repeat/Position · Settings for 8 different times for the
respective programs
can be saved. · If the number of saved settings exceeds 8, the oldest one
will be deleted. · See pages 27 to 28 for detailed functions.
Intensity of massage heads
Style · The massage style that is selected last will be saved. · Settings for
an entire program will be saved. · See pages 27 and 29 for detailed functions.
For Manual Operation
Leg stretch settings
Air massage settings
Note: The following will not be saved: · Reclining angle · Length of ottoman
extension · Arm stretch settings · Manual operation settings
- Massage intensity
Massage action settings
Massage style
Speed, tapping, regional rolling, auto width
Massage head position
40
Erasing saved data
1 Press the button to turn on the power. · The power will turn off
automatically if the massage does not start within 3 minutes after turning on
the power.
2 Press the button corresponding to the settings you wish to delete. Only the
button pressed will illuminate.
3 Confirm the program selection buttons flash. 4 Press the same button again
and hold for 3 or more seconds.
The pressed button will flash.
5 Press the button once again while it is flashing (for approximately 15
seconds). The change from flashing to steady indicates that the deletion is
complete.
41
After completing the massage
The massage will be completed in approximately 15 minutes. For a quick
massage, 5 minutes. · Since the foot section pivots, the legrest will return
to a down and retracted position so that you can safely sit up. To return the
back of the chair to the original position, press the button twice. The chair
does not automatically come up since you may be resting comfortably.
Interrupting the massage
1 Return the legrest to the original position and then press the · The massage heads move to the retracted position.
button.
· The legrest lowers and the backrest rises automatically. The backrest will move after the massage heads retract.
Pull the legrest slide lever back.
Raise the legs slightly and the legrest returns.
When the massage is complete
The
buttons will flash and the unit ready to save any settings that changed during the massage.
Not saving the settings
It is not necessary to operate. The operation will be completed after approx. 15 seconds. Saving the settings
See pages 39 to 41 “Advanced user memory function.”
Emergency Stop
1 Press the button. · All operations will stop immediately. The user program will not be saved in this case. · Get off the unit carefully to prevent the unit tipping over.
42
Disconnecting the power
Warning
· After use, always slide the power switch to the “off” position, turn the
lock switch to the “lock” position and remove the lock switch key. Failure to
observe this precaution may result in accident or injury due to children
playing with the controls.
Caution
· Always hold the power plug, not the power cord, when unplugging from an
outlet. Failure to observe this precaution may result in electric shock or
short-circuit.
· Unplug the power plug from the outlet when the unit is not in use. Failure
to observe this precaution may result in electrical fire due to deterioration
of insulation caused by dust and moisture.
· Keep the lock switch key out of reach of children. Failure to observe this
precaution may result in accident or injury due to accidental ingestion or
children playing with the controls.
1 Slide the power switch to the “off” position.
2 Turn the lock switch key to the “lock” position.
Power supply box
3 Remove the power plug from the electrical outlet.
4 The lock switch key must be stored out of the reach of children.
43
Cleaning and Maintenance
Caution
· Always unplug the unit before cleaning it. Never touch a power plug with wet
hands. Failure to follow these instructions may lead to electrical shock or
burns.
Areas covered with synthetic leather
Wipe these areas with a soft, dry cloth.
· Do not use any leather maintenance tools that are commercially available
(chemical cloth or chemicals). This can cause discoloration or hardening of
the synthetic leather.
· If the synthetic leather is particularly dirty, wipe it in the following
manner.
1. Soak a soft cloth in water or a 3% to 5% solution of mild detergent and
wring it out thoroughly.
2. Dab the surface with the moistened cloth.
3. Rinse the cloth in water, wring it out thoroughly, and then wipe any
remaining detergent from the surface.
4. Wipe the surfaces with a soft, dry cloth.
5. Allow to dry naturally. · Do not use a hair dryer to dry the surface more
quickly. · Since colors may transfer from clothing to the synthetic leather
surface, be careful
when using the unit with clothing such as jeans or colored clothes. · Do not
allow these areas to come in contact with plastic for extended periods of time
as this may lead to discoloration. · Do not use thinners, benzine, or alcohol.
Pipe and Plastic Area
Seat Fabric
1 Wipe the unit with a cloth moistened with mild detergent and thoroughly
wrung out. · Do not use thinners, benzine, or alcohol.
2 Wipe the unit with a cloth moistened with plain water and thoroughly wrung
out. · Be sure you thoroughly wring out the cloth first when cleaning the
control panel.
3 Allow the unit to dry naturally.
1 Wipe the seat fabric with a cloth soaked in mild detergent and thoroughly
wrung out. · Do not use thinners, benzine, or alcohol.
2 Use water or a mild detergent and brush on areas where the seat fabric is
particularly soiled. · Be careful not to brush the fabric too much to avoid
damage.
3 Wipe the unit with a cloth moistened with plain water and thoroughly wrung
out.
4 Allow the unit to dry naturally.
44
Moving the Unit
Caution
· Always return the legrest to its original position before moving the unit.
Failure to observe this precaution may result in injury due to the legrest
returning to its original position when the unit is being moved.
· Do not move the unit while someone is seated in it. Failure to do so may
result in accident or injury due to the unit tipping over.
· When moving the unit with the wheels, remove all obstacles from around it,
make sure the backrest is in the upright position, lift it no higher than
waist height (no higher than 32″ (80 cm)), and roll it slowly. Failure to do
so may cause the unit to tip over, which may lead to damage or injury.
Lifting the Unit
Move the unit by having one person firmly hold onto the fabric section on the
underside of the legrest and another person use the groove on the back cover
of the backrest. · Please hold the groove and the legrest securely to avoid
dropping the unit as it may damage the floor.
Fabric section
Hold onto the fabric section on the underside
of the legrest.
Place your fingers in the groove.
Groove
Legrest
Place the control panel on the seat.
Back cover
To put the unit down on the floor
Put the unit down carefully, making sure your feet are clear of the base. Put
down the legrest by holding it with your hands until it has been set on the
floor completely. If you release your hands before the legrest is fully
extended, the legrest will forcibly return to the initial position.
45
Using the wheels to move the unit
Move the unit by holding onto the fabric section on the underside of the
legrest and using the wheels.
Fabric section
Roll the unit slowly
Hold onto the fabric section on the underside of the legrest
Lift it no higher than waist height
Place the control panel on the seat.
Place a mat on the floor to avoid damaging the floor.
Wheels
To put the unit down on the floor
· Put the unit down carefully, making sure your feet are clear of the base. ·
Put down the legrest by holding it with your hands until it has been set on
the floor completely. If you release your hands before
the legrest is fully extended, the legrest will forcibly return to the initial
position.
46
TROUBLESHOOTING
Problem Motor Noises · It sounds and feels like the massage heads are
straining to
get over wrinkles in the cloth. · The motor groans when it comes under load. ·
There is excessive noise during Tapping. (The noise is
greater at the top of the massage lounger.) · There is a creaking noise when
the massage heads are in
operation. · There is a rattling sound when the massage heads move up
or down. · The belt can be heard rotating. · There is a rubbing sound produced
by the massage heads
rubbing on the seat fabric. · There is a noise when the back cushion moves
over the
armrest when the seat is reclining. · There is a noise when I sit down. ·
There is a strange sound when the massage heads move in
and out. · There is operational noise when applying air pressure. · There is a
noise of discharging air. · The legrest rattles. · There is a humming sound
from the pump. · There is operational noise of valves under the seat. · There
is an unstable sound when air escapes during the leg
stretch. The massage heads stop during operation.
The massage heads do not come up to the shoulder or neck.
The height of the left and right massage heads is different.
Cause and Remedy These sounds are perfectly normal and will not have any
effect on the operation of the unit.
If excessive force is applied to the massage heads during operation, in the
interests of safety the massage heads may stop moving. If all markings and
buttons on the control panel start to flash, which is extremely unusual, turn
off the power switch, wait for approximately 10 seconds and then turn the
power switch on again. If the massage heads stop again, position yourself so
that your back is not completely in contact with the backrest. (Caution should
be exercised particularly when used by persons weighing 220 lbs (100 kg) or
more.) If your head does not contact the pillow or your back does not contact
the backrest, the shoulder position may be detected as lower than the actual
position during the body scanning. Sit on the seat in the deepest position and
put your head on the pillow, and then repeat the operations again from the
start.
(See page 19) An alternating tapping method is employed, which means that this
phenomenon will naturally occur. There is nothing wrong with the unit.
It is not possible to recline the unit. The legrest cannot be raised or
lowered.
Reclining does not take place even though a massage is started in pre-
programs. (The seat does not automatically recline.)
If the unit encounters an obstacle or if excessive force is exerted on it
during operation, in the interests of safety the unit will come to a stop.
When all displays and buttons are flashing and the backrest or the legrest has
stopped, turn off the power of the unit once, turn “on” the power again after
approximately 10 seconds, and then operate the unit.
In some cases the seat may not automatically recline depending on the position
(angle) of the backrest or the legrest.
The backrest does not return to the upright position.
If the unit is stopped by automatic shut-off or by pressing the button, it
will not return automatically. (To return from the
reclined position to the original position, press the button twice.)
47
Problem
The unit will not operate at all. · Upper body (neck to lower back) massage ·
Lower body (calves to seat) massage · Arm massage
Cause and Remedy · The power cord has been disconnected. (See page 16) · The
power switch on the unit has not been turned on.
· A Pre-Program button or Manual Operation button hasn’t
been pressed after pressing .
Sometimes the power won’t turn on when again when a massage has finished.
is pressed Approximately 5 seconds are required for program termination after a massage finishes. Wait at least 5 seconds once all
movement has stopped before pressing .
The unit has been damaged. The power cord or power plug is abnormally hot.
Stop using the unit immediately. Stop using the unit immediately.
Warning
· Do not attempt to repair, disassemble or modify the unit. Failure to observe
this precaution may result in fire or injury due to malfunctioning.
Caution
· Unplug the power plug immediately and contact a customer service center to
arrange for repairs if the unit ceases to function or is otherwise not working
properly. Failure to observe this precaution may result in electric shock or
fire.
SPECIFICATIONS
Power supply
AC 120 V 60 Hz
Power consumption
195 W
Massage area (Up-Down)
Approx. 30 in. (76 cm) (The massage heads move a total of approx. 26 in. (65 cm))
Massage area (Left-Right)
Distance between massage heads during operation (massage width adjustable) Neck, Shoulder, Back, Lower back: Approx. 3 8 in. (7 21 cm)
Upper body massage
Massage area (Forward-back) Projected amount of massage head (Intensity adjustable) Approx. 4 in. (10 cm)
Massage speed
Tap: Approx. 250 450 cycles/minute (single side) Full roll: Approx. 26 92 seconds (both ways) Other than the above: approx. 6 50 cycles/minute
Lateral/Vertical Travel
Lateral travel: Approx. 1.5 in. (3.8 cm) left-right auto return Vertical travel (Long): Approx. 30 in. (76 cm) up-down auto return Vertical travel (Short): Approx. 4 in. (10 cm) up-down auto return
Massage width
Full roll, Vertical Movement: Approx. 3 7 in. (7 18 cm) Other than the above: Same as massage area (left-right)
Air massage
Air Pressure (Calf)
5: Approx. 32 kPa 4: Approx. 30 kPa 3: Approx. 25 kPa 2: Approx. 19 kPa 1: Approx. 8 kPa * It may vary with the area slightly.
Reclining angle
Backrest: Approx 120° 170° Legrest: Approx 0° 85°
Automatic Shut-off
Automatically turns off after approx. 15 minutes (approx. 5 minutes for the quick massage)
When not reclined (H × W × D)
Approx. 47.2 × 33.1 × 50 in. (120 × 84 × 127 cm)
Dimensions
When reclined (H × W × D)
Approx. 28.3 × 33.1 × 76.8 in. (72 × 84 × 195 cm)
Weight of Unit Dimension of box (H × W × D) Weight in box Maximum user weight Minimum distance from wall
Approx. 181 lbs. (82 kg) Approx. 28.3 × 30.7 × 65.4 in. (72 × 78 × 166 cm) Approx. 216 lbs. (98 kg) Approx. 264 lbs (120 kg) 15.7 in. (40 cm)
48
No. 1 EN, SP
Panasonic Consumer Electronics Company
One Panasonic Way 1H-1 Secaucus, New Jersey 07094
1-800-338-0552 for questions and
comments. www.panasonic.com/massage
Printed in China P93103Z06231 Impreso en China
References
- Out.be - Agenda le plus complet de Belgique / De meest volledige agenda van België.
- plug.no is parked
- Райт — отличные интерфейсы, сайты и брендинг
- Repair Your Grill: Shop Replacement Parts for 24,880 Models
- Panasonic Massage Lounger Parts - Select From 25 Models
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>