ELATION PROFESSIONAL 200WMG Rated Electronic Strobe User Manual

August 7, 2024
ELATION PROFESSIONAL

ELATION PROFESSIONAL 200WMG Rated Electronic Strobe

©2024 ELATION PROFESSIONAL all rights reserved. Information, specifications, diagrams, images, and instructions herein are subject to change without notice. ELATION PROFESSIONAL logo and identifying product names and numbers herein are trademarks of ELATION PROFESSIONAL. Copyright protection claimed includes all forms and matters of copyrightable materials and information now allowed by statutory or judicial law or hereinafter granted. Product names used in this document may be trademarks or registered trademarks of their respective companies and are hereby acknowledged. All non- ELATION brands and product names are trademarks or registered trademarks of their respective companies.

ELATION PROFESSIONAL and all affiliated companies hereby disclaim any and all liabilities for property, equipment, building, and electrical damages, injuries to any persons, and direct or indirect economic loss associated with the use or reliance of any information contained within this document, and/or as a result of the improper, unsafe, insufficient and negligent assembly, installation, rigging, and operation of this product.

Elation Professional USA | 6122 S. Eastern Ave. | Los Angeles, CA. 90040
323-582-3322 | 323-832-9142 fax | www.elationlighting.com | info@elationlighting.com

Elation Professional B.V. | Junostraat 2 | 6468 EW Kerkrade, The Netherlands
+31 45 546 85 66 | +31 45 546 85 96 fax | www.elationlighting.eu | info@elationlighting.eu

Elation Professional Mexico | AV Santa Ana 30 | Parque Industrial Lerma, Lerma, Mexico 52000
+52 728-282-7070

DOCUMENT VERSION

Due to additional product features and/or enhancements, an updated version of this document may be available online. Please scan the QR Code with your mobile device or visit www.elationlighting.com for the latest revision/update of this manual, before installation and/or programming.

Date| Document

Version

| Software Version ≥| DMX Channel Modes| Notes
---|---|---|---|---
2/2015| 1| ≥1.03| 6/7/8/12| Initial Release
09/2020| 2| ≥1.19| N/C| Updated Format
10/2021| 3| N/C| N/C| Updated Introduction
12/2021| 4| N/C| N/C| Updated Format
02/21/2022| 5| N/C| N/C| Updated System Menu, added RDM

03/01/2024

|

6

|

N/C

|

N/C

| Added IP65 Rated, IP Test Parameters, Primary- Secondary Setup; updated System Menu

GENER AL INFORMATION

INTRODUCTION
Please read and understand the instructions in this manual carefully and thoroughly before attempting to operate this device. These instructions contain important safety and use information.

IP65 RATED
An IP rated lighting fixture is one, which is commonly installed in outdoor environments and has been designed with an enclosure that effectively protects the ingress (entry) of external foreign objects such as dust and water. The International Protection (IP) rating system is commonly expressed as “IP” (Ingress Protection) followed by two numbers (i.e. IP65) where the numbers define the degree of protection. The first digit (Foreign Bodies Protection) indicates the extent of protection against particles entering the fixture and the second digit (Water Protection) indicates the extent of protection against water entering the fixture. An IP65 rated lighting fixture is one, which has been designed and tested to protect against the ingress of dust (6) and low- pressure water jets from any direction (5).

MARINE COASTAL ENVIRONMENT INSTALLATIONS
Please note that although this fixture is IP rated, the fixture is not suitable for marine/or coastal environment installations. Installing this fixture in a marine and/or coastal environment may cause corrosion and/or excessive wear to the interior and/or exterior components of the fixture. Damages and/or performance issues resulting from installation in a marine and/or coastal environment will void the manufacturers warranty and will not be subject to any warranty claims and/or repairs.
Ensure all connections and end caps are properly sealed with a non-conductive dielectric grease (available at most electrical suppliers) to prevent water ingress/condensation and/or corrosion.

OPTIONAL CORROSION-RESISTANT COATING
Optional Corrosion-Resistant Coatings may be available for this fixture. Please consult your Elation Professional sales representative for details.

UNPACKING
Every device has been thoroughly tested and has been shipped in perfect operating condition. Carefully check the shipping carton for damage that may have occurred during shipping. If the carton is damaged, carefully inspect the device for damage, and be sure all accessories necessary to install and operate the device have arrived intact. In the event damage has been found or parts are missing, please contact our customer support team for further instructions. Please do not return this device to your dealer without first contacting customer support. Please do not discard the shipping carton in the trash. Please recycle whenever possible.

BOX CONTENTS
  • Male Edison to IP Female Power Cable 6,6 ft. (2m)
  • Male 5pin XLR to IP Female DMX Input Cable 3.3 ft (1m)
  • Female 5pin XLR to IP Male DMX Output Cable 3.3 ft (1m)
  • Manual & Warranty Card

CUSTOMER SUPPORT
Contact ELATION Service for any product related service and support needs.
Also visit forums.elationlighting.com with questions, comments or suggestions.

ELATION SERVICE USA – Monday – Friday 8:00am to 4:30pm PST
323-582-3322 | Fax 323-832-9142 | support@elationlighting.com

ELATION SERVICE EUROPE – Monday – Friday 08:30 to 17:00 CET
+31 45 546 85 63 | Fax +31 45 546 85 96 | support@elationlighting.eu

REPLACEMENT PARTS please visit parts.elationlighting.com

WARRANTY RETURNS (USA ONLY)

  • Elation Professional hereby warrants, to the original purchaser, Elation Professional products to be free of manufacturing defects in material and workmanship for a period of two years (730 days), and Elation Professional product rechargeable batteries to be free of manufacturing defects in material and workmanship for a period of six months (180 days), from the original date of purchase. This warranty excludes discharge lamps and all product accessories. This warranty shall be valid only if the product is purchased within the United States of America, including possessions and territories. It is the owner’s responsibility to establish the date and place of purchase by acceptable evidence, at the time service is sought.
  • For warranty service, send the product only to the Elation Professional factory. All shipping charges must be pre-paid. If the requested repairs or service (including parts replacement) are within the terms of this warranty, Elation Professional will pay return shipping charges only to a designated point within the United States. If any product is sent, it must be shipped in its original package and packaging material. No accessories should be shipped with the product. If any accessories are shipped with the product, Elation Professional shall have no liability whatsoever for loss and/or damage to any such accessories, nor for the safe return thereof.
  • This warranty is void if the product serial number and/or labels are altered or removed; if the product is modified in any manner which Elation Professional concludes, after inspection, affects the reliability of the product; if the product has been repaired or serviced by anyone other than the Elation Professional factory unless prior written authorization was issued to purchaser by Elation Professional; if the product is damaged because not properly maintained as set forth in the product instructions, guidelines and/or user manual.
  • This is not a service contract, and this warranty does not include any maintenance, cleaning or periodic check-up. During the periods as specified above, Elation Professional will replace defective parts at its expense, and will absorb all expenses for warranty service and repair labor by reason of defects in material or workmanship. The sole responsibility of Elation Professional under this warranty shall be limited to the repair of the product, or replacement thereof, including parts, at the sole discretion of Elation Professional. All products covered by this warranty were manufactured after January 1, 1990, and bare identifying marks to that effect.
  • Elation Professional reserves the right to make changes in design and/or performance improvements upon its products without any obligation to include these changes in any products theretofore manufactured.
  • No warranty, whether expressed or implied, is given or made with respect to any accessory supplied with the products described above. Except to the extent prohibited by applicable law, all implied warranties made by Elation Professional in connection with this product, including warranties of merchantability or fitness, are limited in duration to the warranty periods set forth above. And no warranties, whether expressed or implied, including warranties of merchantability or fitness, shall apply to this product after said periods have expired. The consumer’s and/or dealer’s sole remedy shall be such repair or replacement as is expressly provided above; and under no circumstances shall Elation Professional be liable for any loss and/or damage, direct and/or consequential, arising out of the use of, and/or the inability to use, this product.
  • This warranty is the only written warranty applicable to Elation Professional products and supersedes all prior warranties and written descriptions of warranty terms and conditions heretofore published.

WARRANTY RETURNS
All returned service items whether under warranty or not, must be freight pre- paid and accompany a return authorization (R.A.) number. The R.A. number must be clearly written on the outside of the return package. A brief description of the problem as well as the R.A. number must also be written down on a piece of paper and included in the shipping container. If the unit is under warranty, you must provide a copy of your proof of purchase invoice. Items returned without a R.A. number clearly marked on the outside of the package will be refused and returned at customer’s expense. You may obtain a R.A. number by contacting customer support.

IP65 RATED

The International Protection (IP) rating system is commonly expressed as “IP” (Ingress Protection) followed by two numbers (i.e. IP65), where the numbers define the degree of protection. The first digit (Foreign Bodies Protection) indicates the extent of protection against particles entering the fixture, and the second digit (Water Protection) indicates the extent of protection against water entering the fixture. An IP65 rated lighting fixture is designed and tested to protect against the ingress of dust (6), and low-pressure water jets from any direction (5).

Maritime/Coastal Environment Installations: A coastal environment is seaside adjacent, and caustic to electronics through exposure to atomized salt water and humidity, whereas maritime is anywhere within 5-miles of a coastal environment.
Maritime installations require additional preparation, and additional service intervals may be needed given the maritime use. In general, IP ratings presuppose freshwater conditions VS maritime conditions, which are typically more “caustic” to IP fixtures (both internally and externally). A duty-cycle may also be needed when units are not in use. During times of high humidity and colder temperatures, condensation may occur internally so the fixture may require a duty-cycle to bring it up to running temperature, allowing any accumulation of moisture to be expelled via the vent valve. Recommendations can change based on installation environmental circumstances.

NOTE : NOT ALL FEATURES LISTED ARE AVAILABLE ON ALL FIXTURES; THE FOLLOWING INSTRUCTIONS MAY NOT APPLY. CONTACT SUPPORT FOR ADDITIONAL DETAILS.

Exterior Maintenance : Inspect the exterior every 30-days. The unit must be powered off/disconnected. The chassis should be inspected for any signs of contaminants. Inspect optics to determine if the lens is obstructed, then clean optics and chassis accordingly. Based on initial finding, schedule maintenance accordingly, keeping in mind that exterior maintenance will be required. Even if the luminaires are NOT in use, maintenance will still be needed given its location (exterior use). The use of a durable type of wax on the chassis is recommended since it will help prevent contaminant build up. Inspect both power and data lines for any signs of contaminants or corrosion. Periodically reapplying di-electric grease, especially in coastal environments. If any signs of corrosion/contaminants are present, clean thoroughly, and/or replace connectors, then reapply di-electric grease. Typically, this should be done annually, or any time an opportunity presents itself. As a preventive measure, annual replacement of both vent valves is recommended. The vent valve membrane can become contaminated and/or clogged causing improper venting of humidity within the luminaire. Inspect all mounting hardware as a precaution.

Interior Maintenance: Inspect the interior every 30-days. The unit must be powered off/disconnected.

  • Inspect zoom/focus mechanism, clean optics, lubricate linear bearings (Krytox oil) as needed, inspect belts for wear
  • Inspect all rotating effect wheels, manually rotate them, note any resistance
  • Inspect all remaining rotating belts for any wear
  • Inspect all fans, clean as needed, check rotation, check connections
  • Inspect CMY module, manually move flags and check for signs of resistance, and if needed, clean guide rods first, then reapply a thin layer of grease (moly lube)
  • Clean interior with low-volume compressed air, then clean optics prior to reassembly of head covers

Although the base has limited moving parts, the pan belt should also be inspected for wear. Remember to always perform an IP test anytime a cover is removed.

There is no specific time frame regarding the routine replacement of parts such as belts/stepper motors, PCBs, or LEDs. These items should only be replaced on an as needed bases, except for cooling fans, which should be replaced once the luminaries reach 10,000-hours. This is a prophylactic measure intended to keep the unit running as cool as possible, insuring proper function of all internal components. A complete service breakdown is available, please contact service@elationlighting.com for any needed parts or manuals.

SAFETY GUIDELINES

This fixture is a sophisticated piece of electronic equipment. To guarantee a smooth operation, it is important to follow all instructions and guidelines in this manual. Elation Professional is not responsible for injury and/or damages resulting from the misuse of this fixture due to the disregard of the information printed in this manual. Only qualified and/or certified personnel should perform installation of this fixture and only the original rigging parts (omega brackets) included with this fixture should be used for installation. Any modifications to the fixture and/or the included mounting hardware will void the original manufactures warranty and increase the risk of damage and/or personal injury.

PROTECTION CLASS 1 – FIXTURE MUST BE PROPERLY GROUNDED.

THERE ARE NO USER SERVICEABLE PARTS INSIDE THIS UNIT.
DO NOT ATTEMPT ANY REPAIRS YOURSELF; DOING SO WILL VOID YOUR MANUFACTURER’S WARRANTY. DAMAGES RESULTING FROM MODIFICATIONS
TO THIS FIXTURE AND/OR THE DISREGARD OF SAFETY INSTRUCTIONS AND GUIDELINES IN THIS MANUAL VOID THE MANUFACTURE’S WARRANTY AND ARE NOT SUBJECT TO ANY WARRANTY CLAIMS AND/OR REPAIRS.

DO NOT PLUG FIXTURE INTO A DIMMER PACK!
NEVER OPEN THIS FIXTURE WHILE IN USE!
UNPLUG POWER BEFORE SERVICING FIXTURE!
NEVER TOUCH FIXTURE DURING OPERATION, AS IT MAY BE HOT!
KEEP FLAMMABLE MATERIALS AWAY FROM FIXTURE!

NEVER LOOK DIRECTLY INTO THE LIGHT SOURCE!
RETINA INJURY RISK – MAY INDUCE BLINDNESS!
SENSITIVE PERSONS MAY SUFFER AN EPILEPTIC SHOCK!

MINIMUM DISTANCE TO OBJECTS/SURFACES
MUST BE 65.6 FEET (20 METERS)
MAXIMUM TEMP OF EXTERNAL SURFACE 212° F (100°C)
MINIMUM DISTANCE OF INFLAMMABLE MATERIALS
FROM THE SURFACE 1.6 FEET (0.5 METER)

  • RISK GROUP 3 – RISK OF EXPOSURE TO ULTRAVIOLET UV RADIATION! FIXTURE EMITS HIGH INTENSITY WAVELENGTH OF ULTRAVIOLET UV LIGHT FROM THE UV LED. WEAR PROPER EYE AND SKIN PROTECTION. AVOID PROLONGED PERIODS OF EXPOSURE TO UV LED. AVOID WEARING WHITE COLOR CLOTHING AND/OR USING UV PAINTS ON SKIN. AVOID DIRECT EYE AND/OR SKIN EXPOSURE AT DISTANCES LESS THAN 11 FEET (3.3m).
  • DO NOT OPERATE FIXTURE WITH DAMAGED/MISSING EXTERNAL COVERS. DO NOT LOOK DIRECTLY INTO THE UV LIGHT AND/OR VIEW UV LIGHT DIRECTLY WITH OPTICAL INSTRUMENTS THAT MAY CONCENTRATE THE LIGHT/RADIATION OUTPUT. INDIVIDUALS SUFFERING FROM A RANGE OF EYE CONDITIONS, SUNLIGHT EXPOSURE DISORDERS, OR INDIVIDUALS USING PHOTOSENSITIVE MEDICATION, MAY RECEIVE DISCOMFORT IF EXPOSED TO THE ULTRAVIOLET UV LIGHT EMITTED FROM THE UV LED.
  • DO NOT TOUCH the fixture housing during operation. Turn OFF the power and allow approximately 15 minutes for the fixture to cool down before serving.
  • DO NOT shake fixture, avoid brute force when installing and/or operating fixture.
  • DO NOT operate fixture if the power cord is frayed, crimped, damaged and/or if any of the power cord connectors are damaged and do not insert into the fixture securely with ease. NEVER force a power cord connector into the fixture. If the power cord or any of its connectors are damaged, replace it immediately with a new one of similar power rating.
  • DO NOT block any air ventilation slots.
  • All fan and air inlets must remain clean and never blocked.
  • Allow approx. 6” (15cm) between fixture and other devices or a wall for proper cooling.
  • Always disconnect fixture from main power source before performing any type of service and/or cleaning procedure. Only handle the power cord by the plug end, never pull out the plug by tugging the wire portion of the cord.
  • During the initial operation of this fixture, a light smoke or smell may emit from the interior of the fixture. This is a normal process and is caused by excess paint in the interior of the casing burning off from the heat associated with the lamp and will decrease gradually over time.
  • Consistent operational breaks will ensure fixture will function properly for many years.
  • ONLY use the original packaging and materials to transport the fixture in for service.

OVERVIEW

TORQUE SETTINGS FOR SCREWS

The hex-head screws holding either the panels or the base MUST be tightened with a torque wrench (not included). TORQUE SETTING = 11 lbf-in. (12.7kgf-cm)*

  • lbf-in = Pound Force Inches | kgf-cm = Kilogram Force Centimeters

CAUTION! DO NOT OVER TORQUE SCREWS AS THIS CAN CAUSE LEAKAGE ISSUES!

IP TEST PARAMETERS

Following any repair or maintenance procedure that requires disassembly of the fixture, use Elation’s IP Tester to confirm the IP integrity of the fixture. The air valve is located on the back panel next to the display screen, as shown in the diagram below. Please contact Elation Service for information regarding the Elation IP Tester, or visit the product information page online at: https://www.elationlighting.com/ip-tester

CAUTION! THE USE OF PROTECTIVE GLOVES AND SAFETY GOGGLES IS STRONGLY RECOMMENDED WHILE PERFORMING THE IP PRESSURE TEST! AVOID PLACING YOUR FACE, EYES, HANDS, ETC IN CLOSE PROXIMITY TO THE FIXTURE’S LENS WHILE PERFORMING THE TEST!

DE-HUMIDIFICATION: IP65 fixtures operating in high-humidity environments may experi-ence residual fogging or condensation. Such fogging will not damage the fixture, and can be removed using the following procedure: position the unit with the air valve pointing upwards, then open the air valve and run the unit for 1-2 hours after reaching operating temperature. Then, while the fixture is still hot, re-install the air valve and allow the unit to cool down. Please note that this procedure should be performed in a dry, air- conditioned environment. Avoid additional fogging by drying the fixture completely before placing into a road case.

IP PRESSURE TESTING PARAMETERS

Low Pressure Limit| High Pressure Limit| Inflation Time| Equilibrium Time| Detection Time| Acceptable Leakage
2.901 psi

(20.0 KPa)

| 3.336 psi

(23.0 KPa)

|

30 sec

|

15 sec

|

15 sec

| 0.015 psi

(0.1 KPa)

(100 Pa)

INSTALLATION GUIDELINES

  • FLAMMABLE MATERIAL WARNING
    Keep fixture minimum 5.0 feet (1.5m) away from flammable materials and/or pyrotechnics.

  • ELECTRICAL CONNECTIONS
    A qualified electrician should be used for all electrical connections and/or installations.

  • USE CAUTION WHEN POWER LINKING OTHER MODEL FIXTURES AS THE POWER CONSUMPTION OF OTHER MODEL FIXTURES MAY EXCEED THE MAX POWER OUTPUT ON THIS FIXTURE. CHECK SILK SCREEN FOR MAX AMPS.

  • MINIMUM DISTANCE TO OBJECTS/SURFACES MUST BE 1.6 FOOT (0.5 METERS)

  • MINIMUM DISTANCE OF INFLAMMABLE MATERIALS FROM THE SURFACE 1.6 FEET (0.5 METER)

  • MAXIMUM AMBIENT TEMPERATURE 113°F (45°C)

  • DO NOT INSTALL THE FIXTURE IF YOU ARE NOT QUALIFIED TO DO SO!

  • Fixture MUST be installed following all local, national, and country commercial electrical and construction codes and regulations.

  • Before rigging/mounting the fixture to any metal truss/structure or placing the fixture on any surface, a professional equipment installer MUST be consulted to determine if the metal truss/structure or surface is properly certified to safely hold the combined weight of the fixture, clamps, cables, and accessories.

  • Overhead rigging requires extensive experience, including, amongst others, calculating working load limits, installation material being used, and periodic safety inspection of all installation material and the fixture. If you lack these qualifications, do not attempt the installation yourself. Improper installation can result in bodily injury.

  • Fixture ambient operating temperature range is 14° to 113°F. (-10° to 45°C)

  • Do not use the fixture under or above this temperature.

  • Fixture should be installed in areas outside walking paths, seating areas, or away from areas were unauthorized personnel might reach the fixture by hand.

  • NEVER stand directly below the fixture when rigging, removing or servicing.

  • Overhead fixture installation must always be secured with a secondary safety attachment, such as an appropriately rated safety cable.

  • Allow approximately 10 minutes for the fixture to cool down before serving.

MOUNTING THE FIXTURE ON A TRUSS USING CLAMP
When mounting the fixture to a truss, be sure to secure an appropriately rated professional grade rigging clamp (not included) to the closed dual yokes using an M10 screw fitted through the center hole of the closed dual yokes. The dual yokes of the fixture provides a rigging point for a SAFETY CABLE (not included). Be sure to only use one of the designated rigging points for the safety cable and never secure a safety cable to a carrying handle.

SAFETY CABLE
ALWAYS ATTACH AN APPROPRIATELY RATED SAFETY CABLE WHENEVER INSTALLING THIS FIXTURE
IN A SUSPENDED ENVIRONMENT TO ENSURE THE FIXTURE WILL NOT FALL IF THE CLAMP FAILS.

RIGGING
Overhead rigging requires extensive experience, including among others calculating working load limits, installation material being used, and periodic safety inspection of all installation material and the fixture. If you lack these qualifications, do not attempt the installation yourself. Improper installation can result in bodily injury.

POWER AND DATA CABLES
TO MAINTAIN THE IP65 RATING INTEGRITY OF THE FIXTURE, ALL CABLES MUST BE RUN TOWARDS THE GROUND TO PREVENT WATER ACCUMULATION AROUND THE CONNECTIONS.

REMOTE DEVICE MANAGEMENT (RDM)

NOTE : In order for RDM to work properly, RDM enabled equipment must be used through-out the entire system, including DMX data splitters and wireless systems.
Remote Device Management (RDM) is a protocol that sits on top of the DMX512 data stan-dard for lighting, allowing the DMX systems of the fixtures to be modified and monitored remotely. This protocol is ideal for instances in which a unit is installed in a location that is not easily accessible.

With RDM, the DMX512 system becomes bi-directional, allowing a compatible RDM enabled controller to send out a signal to devices on the wire, as well as allowing the fixture to respond (known as a GET command). The controller can then use its SET command to modify settings that would typically have to be changed or viewed directly via the unit’s display screen, including the DMX Address, DMX Channel Mode, and Temperature Sensors.
Please be aware that not all RDM devices support all RDM features, and therefore it is important to check beforehand to ensure that the equipment that you are considering includes all of the features that you require.

The following parameters are accessible in RDM on this device:

MANUFACTURER

MANUFACTURER ID
DEVICE ID
MODEL ID
DMX START ADDRESS
DMX PERSONALITY
DMX SLOTS
SOFTWARE VERSION

DMX SETUP

DMX-512
DMX is short for Digital Multiplex. This is a universal protocol used by most lighting and controller manufactures as a form of communication between intelligent fixtures and controllers. DMX allows all makes and models of different manufactures to be linked together and operate from a single controller. This is possible as long as all the fixtures and the controller are DMX compliant. A DMX controller sends the DMX data instructions to the fixture allowing the user to control the different aspects of an intelligent light. DMX data is sent out as serial data that travels from fixture to fixture via data “IN” and data “OUT” XLR terminals located on the fixtures (most controllers will only have output jacks).

DMX LINKING
To ensure proper DMX data transmission, always use the SIXPAR™ series IP rated DMX cables listed in the OPTIONAL ACCESSORIES section at the end of this manual. When using several DMX fixtures try to use the shortest cable path possible. Never split a DMX line with a “Y” style connector. The order in which the fixtures are connected in a DMX line does not influence the DMX addressing. For example; a fixture assigned a starting DMX address of 1 may be placed anywhere in the DMX chain, at the beginning, at the end, or anywhere in the middle. The DMX controller knows to send data assigned to address 1 to that fixture no matter where it is located in the DMX chain. The SIXPAR 200IP™ can be controlled via DMX-512 protocol and the DMX address is set via the control menu.

DMX Cable REQUIREMENTS (For DMX and Primary/Secondary Operation)
Your fixture and your DMX controller require a standard 3pin or 5pin XLR connector for data input and data output. Also, remember that a DMX line must be daisy chained and cannot be split.

DMX-512 CONTROLLER CONNECTION
Connect the provided XLR cable to the female XLR output of your controller and the other side to the male XLR input of the SIXPAR 200IP™ . The diagram below illustrates a typical DMX-512 connection when the fixture is in the 12 Channel Mode. You can chain multiple panels together through serial linking. Always be sure daisy chain your in and out data connections, never split or “Y” your DMX connections.

DMX-512 CONNECTION WITH DMX TERMINATOR
A DMX terminator should be used in all DMX lines especially in longer runs. The use of a terminator may avoid erratic behavior in your DMX line. A terminator is a 120 ohm 1/4 watt resistor that is connected between pins 2 and 3 of a male XLR connector (DATA + and DATA -). This fixture is inserted in the female XLR connector of the last fixture in your daisy chain to terminate the line. Using a line terminator will decrease the possibilities of erratic behavior. Use the SIXPAR™ DMX Terminator End Cap listed in the OPTIONAL ACCESSORIES section at the end of this manual.

DMX ADDRESSING
All fixtures should be given a DMX starting address when using a DMX controller, so the correct fixture responds to the correct control signal. This digital starting address is the channel number from which the fixture starts to “listen” to the digital control information sent out from the DMX controller. The allocation of this starting DMX address is achieved by setting the correct DMX address on the digital display located on the back of the fixture.

The same starting address can be set for all fixtures or a group of fixtures, or set different address for each individual fixture. Be advised that setting all fixtures to the same DMX address will subsequently control all fixtures in the same fashion, in other words, changing the settings of one channel will affect all the fixtures simultaneously.

If a different DMX address is set for each fixture, each unit will start to “listen” to the channel number you have set, based on the quantity of control channels (DMX channels) of each fixture. That means changing the settings of one channel will only affect the selected fixture.

In the case of the SIXPAR 200IP™, when in the 12 Channel Mode you should set the starting DMX address of the first unit to 1, the second unit to 13 (1 + 12), the third unit to 25 (13 + 12), and so on.
Note : During start-up the SIXPAR 200IP™ will automatically detect whether a DMX data signal is being received or not. If the fixture is not receiving a DMX signal please check the following:

  • The 3pin or 5pin XLR input plug (cable with DMX signal from controller) is not connected or is not inserted completely into the DMX input jack of the fixture.
  • The DMX controller is switched off or defective.
  • The DMX cable or connector is defective.
  • A DMX terminator has been inserted into the last fixture in your DMX chain.

SYSTEM MENU

ON-BOARD SYSTEM MENU
The SIXPAR 200IP™ comes with an easy to navigate system menu. The next sections will cover how to access each menu function.

LCD CONTROL PANEL DISPLAY
The (4) button control panel (see image below) located on back of the fixture allows you to access the main menu and make all necessary adjustments to the SIXPAR 200IP™.

During normal operation, pressing the MODE button will navigate through the different function menus. Once you reach a desired menu, press the ENTER button to select that menu. The variable field that can be adjusted within the selected menu will begin to flash. Using the UP or DOWN buttons, adjust the field until the desired value is displayed. For example, the CHANNEL CH: menu variable field can be set to 06, 07, 08, or 12. Pressing the ENTER button once will confirm your selected value. Exit at any time without making any adjustments by pressing the MODE button.

INFORMATION DISPLAYED DURING INITIAL POWER ON
When the fixture is initially powered ON, the display shows the following i

LCD CONTROL PANEL LOCKOUT
When the Display ON menu is set to ON or ON1, the LCD display will turn OFF after 30 seconds and the (4) button Control Panel will be LOCKED. To unlock the (4) button LCD control panel, press and hold the MODE button for 3 seconds when the unit is in ON mode, or press UP, DOWN, UP, DOWN, ENTER when the unit is in ON1 mode.
When installing any Six Par IP unit in a permanent setting, we recommend setting your display to the following: DISPLAY ON>ON1

Display On

| OFF| LCD Display Off after 30 sec
---|---|---
ON| LCD Display Locks after 30 sec, press and hold MODE for 3 sec to unlock
ON1| LCD Display Locks after 30 sec, press UP, DOWN, UP, DOWN, ENTER to unlock

Units in a permanent setting are exposed to various conditions, if a unit is set to OFF the display may interpret a raindrop as a command and change the fixture’s setting (phantom touch). Setting a unit’s display to ON 1 prevents this scenario by locking the touch display after 30 seconds.

SYSTEM MENU

ELATION SIXPAR 200IP

Supports Software Versions: ≥ 1.19
MAIN MENU| OPTIONS / VALUES

(Default Settings in BOLD)

| DESCRIPTION
Channel| CH: 06, 07, 08, 12| DMX Channel Mode
DMX Mode| ADDR: 001 ~ 512| DMX Address Setting
Secondary

Mode

| SECONDARY MODE| Set Fixture A secondary Unit

Display On

| OFF| LCD Display OFF after 30 Seconds, press and hold MODE for 3 sec to unlock
ON| LCD Display Always ON
ON1| LCD Display OFF after 30 Seconds, press UP, DOWN, UP , DOWN, ENTER to unlock

Internal Programs

| 1.MANUAL| Manual Color Adjustment
R00-99| Adjust RED Brightness (00-99)
G00-99| Adjust GREEN Brightness (00-99)
B00-99| Adjust BLUE Brightness (00-99)
W00-99| Adjust WHITE Brightness (00-99)
A00-99| Adjust AMBER Brightness (00-99)
U00-99| Adjust UV Brightness (00-99)
S00-99| Adjust STROBE SPEED 00 SLOW (0.1Hz) – 99 FAST (20Hz)
2.CHANGE| 30 Color Chase Macro
SP01-99| Adjust SPEED 01 SLOW – 99 FAST
S00-99| Adjust STROBE SPEED 00 SLOW (0.1Hz) – 99 FAST (20Hz)
3.CHANG6| 6 Color Chase Macro
SP01-99| Adjust SPEED 01 SLOW – 99 FAST
S00-99| Adjust STROBE SPEED 00 SLOW (0.1Hz) – 99 FAST (20Hz)
4.FADE| Color Fade Macro
SP01-99| Adjust SPEED 01 SLOW 99 – FAST
S00-99| Adjust STROBE SPEED 00 SLOW (0.1Hz) – 99 FAST (20Hz)
DimCurve| Standard, Stage, TV, Architec, Theatre| Set Dimming Curve
No DMX| Blackout| No Output
Hold| Hold Last Setting
Fade| Fade

DIMMER MODE

DMX TR AITS: CHANNEL FUNCTIONS & VALUES

ELATION SIXPAR 200IP

DMX Channel Values / Functions


Supports Software Versions: ≥ 1.19
Features subject to change without notice
MODE/CHANNEL| VALUE| FUNCTION
6CH| 7CH| 8CH| 12CH
1| 1| 1| 1|  | Red:
0-255| Red (0-100%)
2| 2| 2| 2|  | Green:
0-255| Green (0-100%)
3| 3| 3| 3|  | Blue:
0-255| Blue (0-100%)
4| 4| 4| 4|  | White:
0-255| White (0-100%)
5| 5| 5| 5|  | Amber:
0-255| Amber (0-100%)
6| 6| 6| 6|  | U.V.:
0-255| U.V. (0-100%)
 | 7| 7| 7|  | Master Dimmer:
0-255| Dimmer (0-100%)
 |  |

8

|

8

|  | STROBE:
0-31| LED OFF (NO STROBE)
32-95| Strobe Effect SLOW to FAST
96-127| LED ON (NO STROBE
128-159| Strobe Pulse Effect in Sequence SLOW to FAST
160-191| LED ON (NO STROBE)
192-223| Random Strobe Effect SLOW to FAST
224-255| LED ON (NO STROBE)
 |  |  |

9

|  | COLOR MACROS
0-3| OFF
4-7| RED
8-11| GREEN
12-15| BLUE
16-19| WHITE
20-23| AMBER
24-27| UV
28-31| RED + GREEN
32-35| RED + BLUE
36-39| RED + BLUE
40-43| RED + AMBER
44-47| RED + UV
48-51| GREEN + BLUE
52-55| GREEN + WHITE
56-59| GREEN + AMBER
60-63| GREEN + UV
64-67| BLUE + WHITE
68-71| BLUE + AMBER
72-75| BLUE + UV
76-79| WHITE + AMBER
80-83| WHITE + UV
84-87| AMBER + UV
88-91| RED + GREEN + BLUE
92-95| RED + GREEN + WHITE
96-99| RED + GREEN + AMBER
100-103| RED + GREEN + UV
104-107| RED + BLUE + WHITE
108-111| RED + BLUE + AMBER
112-115| RED + BLUE + UV

ELATION SIXPAR 300IP

DMX Channel Values / Functions


Supports Software Versions: ≥ 1.19
Features subject to change without notice
MODE/CHANNEL| VALUE| FUNCTION
6CH| 7CH| 8CH| 12CH
 |  |  |

9

|  |
116-119| RED + WHITE + AMBER
120-123| RED + WHITE + UV
124-127| RED + AMBER + UV
128-131| GREEN + BLUE + WHITE
132-135| GREEN + BLUE + AMBER
136-139| GREEN + BLUE + UV
140-143| GREEN + WHITE + AMBER
144-147| GREEN + WHITE + UV
148-151| GREEN + AMBER + UV
152-155| BLUE + WHITE + AMBER
156-159| BLUE + WHITE + UV
160-163| BLUE + AMBER + UV
164-167| WHITE + AMBER + UV
168-171| RED +GREEN + BLUE + WHITE
172-175| RED + GREEN + BLUE + AMBER
176-179| RED + GREEN + BLUE + UV
180-183| RED + GREEN + WHITE + AMBER
184-187| RED + GREEN + WHITE + UV
188-191| RED + GREEN + AMBER + UV
192-195| RED + BLUE + WHITE + AMBER
196-199| RED + BLUE + WHITE + UV
200-203| RED + BLUE + AMBER + UV
204-207| RED + WHITE + AMBER + UV
208-211| GREEN + BLUE + WHITE + AMBER
212-215| GREEN + BLUE + WHITE + UV
216-219| GREEN + BLUE + AMBER + UV
220-223| GREEN + WHITE + AMBER + UV
224-227| BLUE + WHITE + AMBER + UV
228-231| RED + GREEN + BLUE + WHITE + AMBER
232-235| RED + GREEN + BLUE + WHITE + UV
236-239| RED + GREEN + BLUE + AMBER + UV
240-243| RED + GREEN + WHITE + AMBER + UV
244-247| RED + BLUE + WHITE + AMBER + UV
248-251| GREEN + BLUE + WHITE + AMBER + UV
252-255| RED + GREEN + BLUE + WHITE + AMBER + UV
 |  |  |

10

|  | COLOR CHASE MACROS
0-20| NO FUNCTION
21-40| 30 COLOR CHASE
41-60| 6 COLOR CHASE
61-80| COLOR FADE CHASE
81-255| NO FUNCTION
 |  |  | 11|  | COLOR CHASE MACROS SPEED
0-255| CHASE SPEED OF CHANNEL 10-SLOW TO FAST
 |  |  |

12

|  | DIMMING MODES
0-20| STANDARD
21-40| STAGE
41-60| TV
61-80| ARCHITECTURAL
81-100| THEATER
101-255| NO FUNCTION

PRIMARY-SECONDARY SET UP

This function allows you to link units together to run in a Primary-Secondary set-up, in which one unit will act as the controlling unit and the others will react to the controlling unit’s built-in programs. Any unit can be configured to act as a Primary or as a Secondary, but only one unit in a given system can be programmed to act as the Primary.
Primary-Secondary Connections and Settings:

  1. Daisy chain your units via the XLR connectors on the bottom of each unit. Use standard XLR data cables to link your units together. Remember that the male XLR connector is the input and the female XLR connector is the ouput. The first unit in the chain (primary) will use the female XLR connector only. The last unit in the chain will use the male XLR con-nector only.
  2. On the units that you want to designate as secondaries, use the display screen and control panel to navigate to “Secondary Mode” and press the ENTER button to confirm.
  3. On the unit that you want to designate as the primary, no additional action is required. Simply set the unit to operate in your desired mode, and the linked secondary units will now follow the primary.

NOTES:

  • Only one unit should be configured as the primary, while all the other units should be con-figured as secondaries.
  • All units should be set to the same DMX channel mode.
  • If fixtures fail to sync, verify that all settings mentioned above are the same, then power all devices off, then switch them on again to re-establish the link.

MAINTENANCE GUIDELINES

CLEANING
Frequent cleaning is recommended to insure proper function, optimized light output, and an extended life. The frequency of cleaning depends on the environment in which the fixture operates: damp, smoky or particularly dirty environments can cause greater accumulation of dirt on the fixture’s optics. Clean the external lens surface at least every 20 days with a soft cloth to avoid dirt/debris accumulation.
NEVER use alcohol, solvents, or ammonia-based cleaners.

MAINTENANCE
Regular inspections are recommended to insure proper function and extended life.
There are no user serviceable parts inside this fixture, please refer all other service issues to an authorized Elation service technician. Should you need any spare parts, please order genuine parts from an authorized Elation dealer.
Please refer to the following points during routine inspections:

  • A detailed electric check by an approved electrical engineer every three months, to make sure the circuit contacts are in good condition and prevent overheating.
  • Be sure all screws and fasteners are securely tightened at all times. Lose screws may fall out during normal operation resulting in damage or injury as larger parts could fall.
  • Check for any deformations on the housing, color lenses, rigging hardware and rigging points (ceiling, suspension, trussing). Deformations in the housing could allow for dust to enter into the fixture. Damaged rigging points or unsecured rigging could cause the fixture to fall and seriously injure a person(s).
  • Electric power supply cables must not show any damage, material fatigue or sediments.
  • NEVER remove the ground prong from the power cable.

SPECIFICATIONS

SOURCE
(12) 12W 6-in-1 RGBAW+UV LEDs
100,000 Hour Average LED Life
LED Life may vary depending on several factors including but not limited to:
Environmental Conditions, Power/Voltage, Usage Patterns (On-Off Cycling), Control, and Dimming.

PHOTOMETRIC DATA
22,250 LUX 2.067 FC @3.3’ (1m) (15° Full ON)

EFFECTS
Electronic Strobe
Color and Chase Macros
Electronic Dimming: 0% – 100%
5 Variable Dimming Curve Modes

CONTROL / CONNECTIONS
(4) DMX Channel Modes (6 / 7 / 8 / 12)
(4) Button Touch Control Panel
LCD Menu Display
IP DMX In/Out
IP Power In/Out
With Wired Digital Communication Network

SIZE / WEIGHT
Length: 12.3” (313mm)
Width: 6.2” (157mm)
Vertical Height: 11.8” (300mm)
Weight: 12.6 lbs. (5.7 kg)

ELECTRICAL / THERMAL
AC 110-250V – 50/60Hz
89W Max Power Consumption
Power Linking: 12pcs @110V / 25pcs @240V
5°F to 113°F (-15°C to 45°C)
UV Wavelength: 395nm

APPROVALS / RATINGS
CE | cETLus | IP65

PHOTOMETRIC DATA

DIMENSIONS

Drawings not to scale. Specifications and improvements in the design of this unit and this manual are subject to change without notice.

OPTIONAL ACCESSORIES

ORDER CODE ITEM
SIXPAR0300/GFH Gel Frame Holder Kit
SIXPAR/BD300 Barn Door

NOTE: Gel Frame Holder Kit required to attach Barn Door. (Sold separately)
SIXPAR/2MDLC| 6.6 ft. (2m) IP Data Link Cable
SIXPAR/2MPLC| 6.6 ft. (2m) IP Power Link Cable
SIXPAR/3MDLC| 9.8 ft. (3m) IP Data Link Cable
SIXPAR/3MDLC| 9.8 ft. (3m) IP Power Link Cable
SIXPAR/5MDLC SPECIAL ORDER| 16.4 ft. (5m) IP Data Link Cable
SIXPAR/5MPLC SPECIAL ORDER| 16.4 ft. (5m) IP Power Link Cable
SIXPAR/10MDLC SPECIAL ORDER| 32.8 ft. (10m) IP Data Link Cable
SIXPAR/10MPLC SPECIAL ORDER| 32.8 ft. (10m) IP Power Link Cable
SIXPAR/20MDLC SPECIAL ORDER| 65.6 ft. (20m) IP Data Link Cable
SIXPAR/20MPLC SPECIAL ORDER| S65.6 ft. (20m) IP Power Link Cable
SIXPAR/DIAC| Data IN IP Adapter Cable
SIXPAR/DOAC| Data OUT IP Adapter Cable
SIXPAR/PIAC| Power IN IP Adapter Cable
SIXPAR/POAC| Power OUT IP Adapter Cable
SIXPAR/TERMINATOR| DMX Terminator End Cap

FCC STATEMENT

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

FCC RADIO FREQUENCY INTERFERENCE WARNINGS & INSTRUCTIONS
This product has been tested and found to comply with the limits as per Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This device uses and can radiate radio frequency energy and, if not installed and used in accordance with the included instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this device does cause harmful interference to radio or television reception, which can be deter- mined by turning the device off and on, the user is encouraged to try to correct the interference by one or more of the following methods:

• Reorient or relocate the device.
• increase the separation between the device and the receiver.
• Connect the device to an electrical outlet on a circuit different from which the radio receiver is connected.
• Consult the dealer or an experienced radio/TV technician for help.

Energy Saving Matters (EuP 2009/125/EC)
Saving electric energy is a key to help protecting the environment. Please turn off all electrical products when they are not in use. To avoid power consumption in idle mode, disconnect all electrical equipment from power when not in use. Thank you!

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

ELATION PROFESSIONAL User Manuals

Related Manuals