RICE LAKE 882IS Digital Weight Indicator Fiber Optics to RS-232 Converter Instruction Manual
- August 5, 2024
- RICE LAKE
Table of Contents
RICE LAKE 882IS Digital Weight Indicator Fiber Optics to RS-232 Converter
The fiber optics to RS-232 converter (PN 196769) takes fiber optic light and turns it into a signal for RS-232 communications. The converter is located in an external FRP enclosure that is remotely powered and can be used in applications up to 150 ft.
Manuals are available from Rice Lake Weighing Systems at
www.ricelake.com/manuals
Warranty information is available at
www.ricelake.com/warranties
IMPORTANT : Use anti-static protection for grounding and to protect
components from electrostatic discharge (ESD) when working inside the
enclosure.
WARNING : Disconnect the enclosure from power source before opening.
Fiber Optics Assembly
The fiber optics to RS-232 converter is equipped with a duplex fiber-optic port for communicating with an 882IS or 882IS Plus located in the safe area. It provides electrical isolation and eliminates the use of I/O barriers commonly used in intrinsically safe systems. The optical fibers are plastic and the terminated ends must be properly polished prior to installation. Refer to POF Polishing Kit (PN 197384), for complete instructions on polishing the fiber-optic ends. See Figure 1 on page 1 for the location of the duplex fiber- optic port in the fiber optics to RS-232 converter.
WARNING : Disconnect all power before opening the units being updated.
IMPORTANT : The fiber-optic connections between the 882IS and 882IS Plus
indicator and the RS-232 converter needs to be cross-linked. The optical
output of the 882IS indicator should be attached to the input of the RS-232
converter, and the indicator input to the module output.
Use the following steps for assembling the fiber-optic connectors of the fiber-optic to RS-232 converter:
-
Cut off the ends of the fiber-optic cable (150 ft length maximum), with a proper cutting tool such as a fiber-optic hot knife (PN 85548) or cutting block (PN 80892), ensuring no bends 90° or greater are in the cable.
NOTE : The cut end of the fiber-optic cable must be cut flush so that the core and outside insulation are equal. Core exposure can lead to failure. -
Polish the fiber ends per the fiber polishing kit.
-
Insert the fiber-optic cable through the locking nut and into the connector until the core tip seats against the internal micro-lens; then back it out 1/16 in (1 mm).
-
Screw the connector locking nut down to a snug fit, locking the fiber-optic cable in place.
Remote Power Source for Fiber Optics to RS-232 Converter
NOTE : If source indicator has a digital input/output, it will provide 5V
which can be used to power the card.
Connector J4 provides connections for power.
Pin | Description |
---|---|
1 | V+ (6 V–24 V) |
2 | V- (GND) |
Table 1. J4 Power Connections
Connector J3 provides connections for the RS-232.
Pin | Description |
---|---|
1 | TX |
2 | RX |
3 | GND |
Table 2. J3 RS-232 Connections
Replacement Parts
Item No. | Part No. | Description | Qty. |
---|---|---|---|
1 | 197028 | Enclosure, Machined FRP | 1 |
2 | 15655 | Cord Grip, 3/8 NPT | 3 |
3 | 73997 | Bushing, Multiple Cable Gland 9 mm – 3/8 NPT | 2 |
4 | 15664 | Reducing Gland, 9 mm – 3/8 NPT | 1 |
5 | 178464 | Seal Ring, 3/8 NPT Nylon | 3 |
6 | 15656 | Locknut, 3/8 NPT | 3 |
7 | 85308 | Backplate, FRP | 1 |
8 | 78908 | Plate Assembly, RS-232/Fiber Optics Board Mount | 1 |
9 | 77788 | Fiber Optics Board, RX/TX Option | 1 |
10 | 14822 | Machine Screw, 4-40NC x 1/4 Phillips Pan Head Internal Tooth Lock, | |
Steel Zinc Plated | 1 | ||
11 | 198337 | Label, Wiring, Fiber Optics to RS-232 Converter Option | 1 |
12 | 15631 | Cable Tie, 3 in Nylon | 6 |
13 | 15650 | Mount, Cable Tie, 3/4 in | 3 |
14 | 197846 | Power Supply, 15 W 12 VDC Universal Input, 100-240VAC (not shown) |
1
15| 52342| Label, 4.00 x 1.25 VOID Matte| 1
16| 14729| Bolt, 1/4-NC x 3/4 Hex Head, Bronze| 1
17| 14637| Nut, 1/4-20NC Hex, Bronze Width Across Flats| 1
18| 33188| Connector, Ring Terminal 1/4 in Stud Size 22-16 AWG| 1
19| 15149| Washer, Plain STD 1/4 SST| 1
20| 15148| Lock Washer, 1/4 Regular Helical Spring SST| 1
21| 14642| Nut, 1/4-20NC Hex SST Width Across Flats| 1
© Rice Lake Weighing Systems Content subject to change without notice.
230 W. Coleman St. • Rice Lake, WI 54868 • USA USA:
800-472-6703 • International:
+1-715-234-9171
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>