RICE LAKE 882IS Digital Weight Indicator Fiber Optics to RS-232 Converter Instruction Manual

August 5, 2024
RICE LAKE

RICE LAKE 882IS Digital Weight Indicator Fiber Optics to RS-232 Converter

The fiber optics to RS-232 converter (PN 196769) takes fiber optic light and turns it into a signal for RS-232 communications. The converter is located in an external FRP enclosure that is remotely powered and can be used in applications up to 150 ft.

Manuals are available from Rice Lake Weighing Systems at www.ricelake.com/manuals
Warranty information is available at www.ricelake.com/warranties

IMPORTANT : Use anti-static protection for grounding and to protect components from electrostatic discharge (ESD) when working inside the enclosure.
WARNING : Disconnect the enclosure from power source before opening.

Fiber Optics Assembly

The fiber optics to RS-232 converter is equipped with a duplex fiber-optic port for communicating with an 882IS or 882IS Plus located in the safe area. It provides electrical isolation and eliminates the use of I/O barriers commonly used in intrinsically safe systems. The optical fibers are plastic and the terminated ends must be properly polished prior to installation. Refer to POF Polishing Kit (PN 197384), for complete instructions on polishing the fiber-optic ends. See Figure 1 on page 1 for the location of the duplex fiber- optic port in the fiber optics to RS-232 converter.

WARNING : Disconnect all power before opening the units being updated.
IMPORTANT : The fiber-optic connections between the 882IS and 882IS Plus indicator and the RS-232 converter needs to be cross-linked. The optical output of the 882IS indicator should be attached to the input of the RS-232 converter, and the indicator input to the module output.

Use the following steps for assembling the fiber-optic connectors of the fiber-optic to RS-232 converter:

  1. Cut off the ends of the fiber-optic cable (150 ft length maximum), with a proper cutting tool such as a fiber-optic hot knife (PN 85548) or cutting block (PN 80892), ensuring no bends 90° or greater are in the cable.
    NOTE : The cut end of the fiber-optic cable must be cut flush so that the core and outside insulation are equal. Core exposure can lead to failure.

  2. Polish the fiber ends per the fiber polishing kit.

  3. Insert the fiber-optic cable through the locking nut and into the connector until the core tip seats against the internal micro-lens; then back it out 1/16 in (1 mm).

  4. Screw the connector locking nut down to a snug fit, locking the fiber-optic cable in place.

Remote Power Source for Fiber Optics to RS-232 Converter

NOTE : If source indicator has a digital input/output, it will provide 5V which can be used to power the card.
Connector J4 provides connections for power.

Pin Description
1 V+ (6 V–24 V)
2 V- (GND)

Table 1. J4 Power Connections

Connector J3 provides connections for the RS-232.

Pin Description
1 TX
2 RX
3 GND

Table 2. J3 RS-232 Connections

Replacement Parts

Item No. Part No. Description Qty.
1 197028 Enclosure, Machined FRP 1
2 15655 Cord Grip, 3/8 NPT 3
3 73997 Bushing, Multiple Cable Gland 9 mm – 3/8 NPT 2
4 15664 Reducing Gland, 9 mm – 3/8 NPT 1
5 178464 Seal Ring, 3/8 NPT Nylon 3
6 15656 Locknut, 3/8 NPT 3
7 85308 Backplate, FRP 1
8 78908 Plate Assembly, RS-232/Fiber Optics Board Mount 1
9 77788 Fiber Optics Board, RX/TX Option 1
10 14822 Machine Screw, 4-40NC x 1/4 Phillips Pan Head Internal Tooth Lock,
Steel Zinc Plated 1
11 198337 Label, Wiring, Fiber Optics to RS-232 Converter Option 1
12 15631 Cable Tie, 3 in Nylon 6
13 15650 Mount, Cable Tie, 3/4 in 3
14 197846 Power Supply, 15 W 12 VDC Universal Input, 100-240VAC (not shown)

1
15| 52342| Label, 4.00 x 1.25 VOID Matte| 1
16| 14729| Bolt, 1/4-NC x 3/4 Hex Head, Bronze| 1
17| 14637| Nut, 1/4-20NC Hex, Bronze Width Across Flats| 1
18| 33188| Connector, Ring Terminal 1/4 in Stud Size 22-16 AWG| 1
19| 15149| Washer, Plain STD 1/4 SST| 1
20| 15148| Lock Washer, 1/4 Regular Helical Spring SST| 1
21| 14642| Nut, 1/4-20NC Hex SST Width Across Flats| 1

© Rice Lake Weighing Systems Content subject to change without notice.
230 W. Coleman St. • Rice Lake, WI 54868 • USA USA: 800-472-6703 • International: +1-715-234-9171

www.ricelake.com

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

RICE LAKE User Manuals

Related Manuals