ACT AC7851 Video Switches and Splitters Instruction Manual
- June 9, 2024
- ACT
Table of Contents
Quick Install Guide AC7851
Snel installeren
IHDMI over IP Receiver
Installation Diagram
Change IP Settings
NOTE: You only need to change the IP-address range of the RX and TX units if the default IP-addresses will conflict with the IP-settings of your network. For multiple RX-units you only need to adjust the RX units. Please follow the steps mentioned below. IP Settings.
- Out of the box the default IP address for the RX unit is 192.168.168.56. It is important that each RX unit has a different IP address. Please make sure to enter an IP address in the same range as your other RX unit(s).
- Before you connect the RX unit to your PC/laptop, you have to provide a static IP address to the network adapter of your PC/laptop. The IP address of your network adapter should be in the same range as from the RX unit. For example 192.168.168.10
- Connect the RX unit with a UTP cable to your PC or laptop and fill out the following IP address in your intemet browser address bar: http://192.168.168.56 to login to the RX webinterface.
- Click on System – System Settings.
- Now you can change the IP address for the RX unit and make sure to enter an IP address in the same range as your other RX unit(s).
- When you have changed the IP address, press ‘Apply”.
- When you have multiple receivers connected, please make sure that each unit should have its own unique Mac address. You can change the Mac address by only changing the last two digits to a higher number. When you have changed the Mac address, press *Apply”.
Note: Both RX unit(s) and TX unit need to be in the same IP range!
Reset to factory defaults: If you need to restore the device to it’s
factory default settings, please power on the device. The red Power LED will
lit. Wait for around 10 seconds. The green status LED will lit. Now you can
press the reset button for 5-10 seconds. The green status LED will go out and
will lit again after several seconds. You have successfully restored your
device to factory defaults.
For service, manuals, firmware updates or support visit www.act-
connectivity.com l Multilingual manual I
For PLUGGABLE EQUIPMENT, the socket-outlet shall be installed near the
equipment and shall be easily accessible.
www.act-connectivity.com
ACT, Koolhovenstraat 1E, 3772 MT Barneveld, The Netherlands.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>