BROMIC REFRIGERATION SVM1000SD-NR Semi Verticals and Full Height Multidecks Instruction Manual

July 29, 2024
BROMIC REFRIGERATION

BROMIC-REFRIGERATION-logo

BROMIC REFRIGERATION SVM1000SD-NR Semi Verticals and Full Height

Multidecks

BROMIC-REFRIGERATION-SVM1000SD-NR Semi-Verticals-and-Full-Height-Multidecks-
product

MODELS

  • 3335649-NR, 3335650-NR, 3335651-NR, 3335652-NR,
  • 3335639-NR, 3335640-NR, 3335643-NR, 3335641-NR,
  • 3335642-NR, 3335644-NR, 3335645-NR, 3335648-NR,
  • 3335646-NR, 3335647-NR.

Note: Bromic Refrigeration reserves the right to make changes to specifications, parts, components, and equipment without prior notification. This Installation, operation, and service manual may not be reproduced in any form without prior written consent from Bromic Refrigeration.

PREFIX

This manual contains important information about the installation, operation, and maintenance of Bromic Multideck units. Please pay close attention to the important safety information shown throughout this instruction manual. Any safety information will be accompanied by the following safety alert symbols:

DANGER, WARNING, IMPORTANT

  • READ THIS MANUAL CAREFULLY before installing or servicing this product.
  • Improper installation, operation, or maintenance can result in death, severe injury, or property damage.
  • Improper installation, operation, or maintenance may also result in the warranty being voided.
  • This appliance is intended for a 230-240 Volt power supply.
  • Installation and maintenance MUST be carried out as per instruction, by a qualified technician by local regulation

IMPORTANT NOTES AND WARNINGS

  • Read all instructions before installing or using this appliance
  • Retain this manual for future reference
  • Use this appliance only as described in this manual. Any other use not recommended by the manufacturer may cause fire, electric shock, or injury.
  • Improper installation, adjustment, or alteration and failure to follow the warnings and instructions in this manual could result in severe personal injury, death, or property damage
  • The manufacturer is not responsible for any damage that could happen from improper use. The manufacturer emphasizes that this appliance should be used responsibly and that all procedures, warnings, and safety instructions contained in this booklet be followed strictly.
  • Check the appliance for damage. Do not operate a damaged unit.
  • Check for damage to the appliance regularly. If damage to the appliance is suspected, discontinue use immediately and contact the supplier or qualified person to repair it.
  • This appliance is not intended for use by people (including children) with reduced physical, sensory, or mental capabilities, or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible of their safety.
  • Keep packaging material out of reach of children
  • Children should be carefully supervised to ensure that they do not play with the appliance
  • Do not attempt to alter the appliance in any manner.
  • Please pay attention to the maximum load limit when filling the shelves.
  • All work on electrical equipment must be carried out by a qualified and licensed technician only.
  • Do not perform maintenance until the appliance has been turned off and power disconnected.
  • Never detach any cover except where specifically instructed in this manual. Doing so might expose live electrical parts.
  • Do not operate the appliance with panels, covers or guards removed.
  • Keep the air intake and outlets free of obstructions.
  • Do not use the appliance outdoors.
  • If the supply cord becomes damaged, it must be replaced by an authorized service agent or similarly qualified person to avoid a hazard.
  • If the appliance has not been used, or will not be used for a long period, disconnect the power supply.
  • The appliance must be installed by AS1677.2:1998 to ensure there are no sources of ignition in any area where refrigerant could gather in the event of a leak.
  • Electrical equipment should not be placed under the unit or where refrigerant could gather in the event of a leak.
  • Installation/servicing of the appliance must be performed by a licensed technician with Gas Work Authorization if the appliance gas system is being opened or charged.
  • The refrigerant used in all appliances covered in this manual is flammable.

PACKAGING AND HANDLING

  • This Semi Vertical display contains fragile glass. The unit must always be handled with care.
  • Adjust the width of forklift tines such that they line up with the structural supports on the Semi Vertical unit before lifting.
  • The Semi Vertical unit must always be handled on flat and level ground.
  • Take care not to damage the castors, while inserting forklift tines into the pallet.BROMIC-REFRIGERATION-SVM1000SD-NR Semi-Verticals-and-Full-Height-Multidecks-fig-1 \(1\)

PRODUCT OVERVIEW

| SVM1000SD- NR| SVM1250SD- NR| SVM1580SD- NR| SVM1875SD- NR| SVM2500SD-NR
---|---|---|---|---|---
Part Number| 3335644-NR| 3335645-NR| 3335648-NR| 3335646-NR| 3335647-NR
| Height, mm        1500| 1500| 1500| 1500| 1500
External Dimension| Width, mm         1022| 1334| 1580| 1959| 2584
| Depth, mm         825| 825| 825| 825| 825
Volume| Litres                332| 443| 559| 664| 885
Unit Weight| Kg                   165| 190| 220| 240| 290
Total Display Area| m2 1.44| 1.89| 2.20| 2.69| 3.49
Packaged Weight| Kg                   190| 215| 245| 265| 315
| Range               -1°C to +10°C| -1°C to +10°C| -1°C to +10°C| -1°C to +10°C| -1°C to +10°C
Temperature| Type                 Digital| Digital| Digital| Digital| Digital
| Ambient            25°C| 25°C| 25°C| 25°C| 25°C
Climate Class| Rating               3M1| 3M1| 3M1| 3M1| 3M1
Energy Consumption| kWh/24h           2.6| 3.1| 4.1| 4.6| 6.9
GEMS Star Rating| Stars                10| 10| 9| 9| 8
Refrigeration| Refrigerant         580W| 583W| 340W| 829W| 842W
Air Circulation| Type                 Fan Forced| Fan Forced| Fan Forced| Fan Forced| Fan Forced
Refrigerant| Type                 R290| R290| R290| R290| R290
| Current, A          2.52| 2.53| 1.48| 3.60| 3.66
| Electrical, V        220-240| 220-240| 220-240| 220-240| 220-240
Electrical| | | | |
| Frequency          50Hz| 50Hz| 50Hz| 50Hz| 50Hz
| Power Supply      Single Phase| Single Phase| Single Phase| Single Phase| Single Phase
Plug Supply| Supplied              1 x 10A| 1 x 10A| 1 x 10A| 1 x 10A| 1 x 10A
| Plug Location      Rear| Rear| Rear| Rear| Rear
| Cord Length       2m| 2m| 2m| 2m| 2m
Color| External             Black| Black| Black| Black| Black
Internal Light| Type                 LED| LED| LED| LED| LED
| Colour Temp.       4000K| 4000K| 4000K| 4000K| 4000K
| No. of Doors        2| 2| 2| 2| 4
| Door Type          Glass| Glass| Glass| Glass| Glass
Door| | | | |
| Door Style          Sliding| Sliding| Sliding| Sliding| Sliding
| Door Lock          No| No| No| No| No
| Self-Closing         No| No| No| No| No
Shelves Tiers| No. incl. Base        4| 4| 4| 4| 4
| Type                 Adjustable| Adjustable| Adjustable| Adjustable| Adjustable
| Dimensions        250(d), 300(d), 350(d) mm| 250(d), 300(d),

350(d) mm

| 250(d), 300(d),

350(d) mm

| 250(d), 300(d),

350(d) mm

| 250(d), 300(d),

350(d) mm

Air Curtain| Y/N                  Yes| Yes| Yes| Yes| Yes
Castors| Y/N                  Yes| Yes| Yes| Yes| Yes
| SVM1000HD- NR| SVM1250HD- NR| SVM1580HD- NR| SVM1875HD- NR| SVM2500HD- NR
---|---|---|---|---|---
Part Number| 3335639-NR| 3335640-NR| 3335643-NR| 3335641-NR| 3335642-NR
| Height, mm        1500| 1500| 1500| 1500| 1500
External Dimension| Width, mm        1022| 1334| 1580| 1959| 2584
| Depth, mm         825| 825| 825| 825| 825
Volume| Litres                332| 443| 559| 664| 885
Unit Weight| Kg                   165| 190| 220| 240| 290
Total Display Area| m2 1.44| 1.89| 2.20| 2.69| 3.49
Packaged Weight| Kg                   190| 215| 245| 265| 315
| Range               -1°C to +10°C| -1°C to +10°C| -1°C to +10°C| -1°C to +10°C| -1°C to +10°C
Temperature| Type                 Digital| Digital| Digital| Digital| Digital
| Ambient            25°C| 25°C| 25°C| 25°C| 25°C
Climate Class| Rating               3M1| 3M1| 3M1| 3M1| 3M1
Energy Consumption| kWh/24h           2.6| 3.1| 4.1| 4.6| 6.9
GEMS Star Rating| Stars                10| 10| 9| 9| 8
Refrigeration| Refrigerant         580W| 583W| 340W| 829W| 842W
Air Circulation| Type                 Fan Forced| Fan Forced| Fan Forced| Fan Forced| Fan Forced
Refrigerant| Type                 R290| R290| R290| R290| R290
| Current, A          2.52| 2.53| 1.48| 3.60| 3.66
| Electrical, V        220-240| 220-240| 220-240| 220-240| 220-240
Electrical| | | | |
| Frequency          50Hz| 50Hz| 50Hz| 50Hz| 50Hz
| Power Supply      Single Phase| Single Phase| Single Phase| Single Phase| Single Phase
Plug Supply| Supplied              1 x 10A| 1 x 10A| 1 x 10A| 1 x 10A| 1 x 10A
| Plug Location      Rear| Rear| Rear| Rear| Rear
| Cord Length       2m| 2m| 2m| 2m| 2m
Color| External             Black| Black| Black| Black| Black
Internal Light| Type                 LED| LED| LED| LED| LED
| Colour Temp.       4000K| 4000K| 4000K| 4000K| 4000K
| No. of Doors        2| 2| 2| 4| 4
| Door Type          Glass| Glass| Glass| Glass| Glass
Door| | | | |
| Door Style          Hinged| Hinged| Hinged| Hinged| Hinged
| Door Lock          No| No| No| No| No
| Self-Closing         Yes| Yes| Yes| Yes| Yes
| Swing Dimension 469mm| 625mm| 748mm| 469mm| 625mm
| Total Depth of

Door Open         1259mm

| ****

1415mm

| ****

1538mm

| ****

1259mm

| ****

1415mm

Shelves Tiers| No. incl. Base        4| 4| 4| 4| 4
| Type                 Adjustable| Adjustable| Adjustable| Adjustable| Adjustable
| Dimensions        250(d), 300(d), 350(d) mm| 250(d), 300(d),

350(d) mm

| 250(d), 300(d),

350(d) mm

| 250(d), 300(d),

350(d) mm

| 250(d), 300(d),

350(d) mm

Air Curtain| Y/N                  Yes| Yes| Yes| Yes| Yes
Castors| Y/N                  Yes| Yes| Yes| Yes| Yes

BROMIC-REFRIGERATION-SVM1000SD-NR Semi-Verticals-and-Full-Height-Multidecks-
fig-1 \(18\)

INSTALLATION

Locating the Cabinet

  • Ensure the following instructions are observed as this is vital for proper and trouble-free operation.
  • Do not install the cabinet outdoors.
  • Locate the appliance in a dry and well-ventilated place.
  • The unit must be positioned on a level surface.
  • Do not install in the vicinity of heating radiators or other heat sources.
  • Do not install the appliance where it is exposed to direct sunlight.
  • Do not install the appliance where it is exposed to warm draughts or open doors.
  • Keep the air intake and outlets free of obstructions.
  • Adequate allowance should be made for door openings.

BROMIC-REFRIGERATION-SVM1000SD-NR Semi-Verticals-and-Full-Height-Multidecks-
fig-1 \(2\)

Ventilation

  • Allow 50mm clearance between walls and the appliance.
  • Ensure that the condenser fan is free to take in ambient air from the room.
  • Adherence to minimum clearances is necessary

NOTE: The maximum ambient temperature for the refrigerator is 30°C. Conditions outside this temperature will result in cabinet temperatures outside the required 2 to 8°C range. Bromic recommends that the refrigerator is installed at an ambient temperature of 20 to 25°C.

Power Supply

  • The appliance must not be plugged into a multiple-outlet power board.
  • The appliance is supplied with a flexible power cord fitted with a 3-pin plug.
  • The socket used must be properly earthed and fuse/RCD protected.
  • See the rating label inside the cabinet for supply voltage, frequency and current draw.
  • The power cable is rated 70°C. It is recommended that the cable should not come into contact with parts over 50°C.
  • Do not turn off power before consulting the person responsible.
  • Mark the power source clearly, so the refrigerator is not unplugged or turned of accidentally.

BROMIC-REFRIGERATION-SVM1000SD-NR Semi-Verticals-and-Full-Height-Multidecks-
fig-1 \(4\)

Before Operating

  • If the appliance has been sharply tilted or transported in the horizontal position, it must be left to stand in the upright position and not plugged in for at least 4 hours.
  • Remove all the packaging material before using the appliance.
  • Start the appliance only if it has been installed as described.

OPERATION

Start-up

  • Connect the appliance to the mains power supply and turn on the main switch (blue) by flipping it upward. Note that some models do not have the main switch (blue). In that case, simply proceed to the next instruction.
  • The switches (image below) control cabinet cooling, glass heating, and lighting respectively. All switches should be flipped on for standard cabinet operation.
  • Check that the electronic controller, lighting, and fans are operating correctly.
  • The compressor and condenser fan should operate within 3 minutes after the Refrigeration switch is turned on.
  • The electronic controller will display the current cabinet temperature after the Refrigeration switch is turned on.
  • The LED indicates that the refrigeration circuit is operating.
  • During the start-up delay (3 minutes), the LED is flashing
  • The LED indicates that the refrigeration circuit is defrosting

Switches

BROMIC-REFRIGERATION-SVM1000SD-NR Semi-Verticals-and-Full-Height-Multidecks-
fig-1 \(6\)

Setting the temperature

BROMIC-REFRIGERATION-SVM1000SD-NR Semi-Verticals-and-Full-Height-Multidecks-
fig-1 \(7\)

  1. Press the button for more than 3 seconds.
  2. The value of the set point will be displayed and the ‘°C’ or ‘°F’ LED will start blinking.
  3. Press or arrow key within 10 seconds to adjust the set point.
  4. Press the key again or wait 10 seconds.

PRODUCT LOADING AND STORAGE

  • IMPORTANT: Run the refrigerator for at least 2 hours before loading.
  • WARNING: Do not store explosive substances such as aerosol cans with a flammable propellant inside the appliance.

Start-up

  • Clean the interior surface with a soft cloth and warm water before loading.
  • Ensure there is free circulation of air between the products.
  • Do not block the evaporator fan.
  • Keep refrigerator door openings to a minimum.
  • Some products are sensitive to ultraviolet (UV) light, please see storage guidelines from the manufacturer before removing them from packaging.
  • Do not block the top or bottom grills when loading the cabinet. This can reduce cooling performance.
  • Do not overstock the cabinet: goods touching the cabinet walls and glass will not cool properly.

NOTE: Bromic cannot be responsible for loss of stock or damage to stock.

MAINTENANCE

  • WARNING: Disconnect the appliance from the power supply before performing any maintenance. Never unplug the appliance by pulling on the cord. Always grasp the plug firmly and pull straight out of the outlet.
  • WARNING: Exposure to significant water ingress will void the warranty and cause potential safety issues. If the unit should be exposed to water, please contact the manufacturer immediately.
  • IMPORTANT: Warranty may be void if there is no evidence of preventative maintenance performed on the appliance.

Cleaning the Cabinet

  • Remove the products and transfer them to a suitable location before cleaning the inside of the cabinet.
  • Do not use any aggressive or abrasive cleaning agents.
  • Never use a water hose or a high-pressure jet to clean.
  • Do not use sharp or pointed objects for cleaning.
  • Clean the inside and outside of the appliance with a clean damp cloth or with a neutral cleanser.
  • Dry all surfaces with a dry cloth.

Condenser Coil/Filter

  • IMPORTANT: The filter and the condenser coil must be cleaned once a month.
  • The condenser coil must be cleaned with a vacuum/brush monthly to maintain performance and minimize power consumption. A poorly maintained condenser coil can lead to failure of the unit and higher cabinet temperatures.

General cleaning

  • The Semi-Vertical display must be wiped down regularly.
  • Preventing the build-up of oil and sediments will increase the longevity of the unit.

Condenser cleaning

  • A clogged condenser can result in reduced cooling performance.
  • The condenser must be cleaned every 6 weeks.
  • Recommended cleaning methods include:
  • Vacuum cleaner
  • Cleaning brush
  • Compressed air

Drain hose cleaning

  • The drainage hose must be kept clean and clear.
  • A clogged drainage hose can cause the unit to leak.BROMIC-REFRIGERATION-SVM1000SD-NR Semi-Verticals-and-Full-Height-Multidecks-fig-1 \(11\)

TROUBLESHOOTING

IMPORTANT: Repairs on the unit must be carried out by an authorized and licensed person only. Contact the manufacturer or an approved service agent for any repairs needed.

Symptom| Possible Cause(s)|
---|---|---
The unit does not work| A. No power supply| A. Check power supply
Cabinet Temperature is Too High| A.  Ambient temperature too high

B.   Inadequate ventilation

C. Wall clearances below minimum distance

D. Dirty condenser coil and filter

E.  Ice build-up on evaporator coil

| A.  Relocate unit

B.   Keep ventilation slots free

C.  Adjust to minimum clearance

D. Clean

E.  Check gaskets and set temperature

Cabinet Temperature Too Low| A. Set temperature too low| A. Adjust set temperature
Drip tray overflowing| A. Extreme operating condition| A. Relocate unit
Odour inside cabinet| A. Cabinet dirty| A. Clean
No display on the controller| A.  No power supply

B.   Cabinet fuse blown

| A.  Check power supply

B.   Contact Bromic customer service

High power consumption| A.  Cabinet doors opened more frequently

B.   Condensor blocked

c. Inadequate ventilation

| A.  Keep cabinet doors open for the minimum required time

B.   Clean condenser

C.  Keep ventilation slots free

MULTIPLEXING PROCEDURE

The multiplexing procedure can be used to connect multiple Bromic Semi Vertical units.

  • A Bromic multiplexing kit must be used for this procedure.
  • The multiplexing procedure must be performed by a licensed technician.BROMIC-REFRIGERATION-SVM1000SD-NR Semi-Verticals-and-Full-Height-Multidecks-fig-1 \(12\)

ALTERNATE CONFIGURATIONS

BROMIC-REFRIGERATION-SVM1000SD-NR Semi-Verticals-and-Full-Height-Multidecks-
fig-1 \(19\)

ENVIRONMENTAL AND DISPOSAL NOTES

These refrigerated cabinets are designed to high standards of environmental protection and recycling convenience. Cyclopentane, an environmentally friendly foaming agent, has been used. Cyclopentane is distinguished by zero ozone depletion potential (ODP) and zero global warming potential (GWP). The refrigerant used and contained within a hermetically tight circuit is environmentally friendly does not contain chlorine and has zero ODP. The device must be disposed of under applicable regulations. The WEEE regulations must be observed. In the interest of preventing environmental nuisance and promoting re-use of the high-quality materials employed, used commercial refrigeration equipment must be collected for expert disposal and recycling. Therefore, observe the following disposal regulations:

  • The cabinet must not be discarded with regular waste.
  • The refrigeration circuit must not be damaged.
  • Before disposal, make it unserviceable by disconnecting the power plug and cutting off the power cable.
  • Consult your local authorities or authorized dealers for details of collection and disposal facilities.
  • Children are often unable to recognize the dangers associated with commercial refrigeration equipment. Proper supervision must be maintained and children must be prevented from playing with discarded refrigerated cabinets.
  • The refrigerant used in all appliances covered by this manual is flammable.

WARRANTY

  • All Bromic products are manufactured to the highest quality standard and are supported by our Extra Care Service Warranty, including guarantees against any material or workmanship defects; guarantees that cannot be excluded under Australian Consumer Law.
  • Warranty Terms vary across the range. Please ensure you are familiar with the Terms and Conditions that apply to the purchase of your Bromic product by referring to the Warranty Policy included with your purchased product.
  • Alternatively, you can also download the Warranty Policy at https://www.bromicrefrigeration.com.au/support/warranty/.

HOW TO PLACE A SERVICE REQUEST

  • Please call 1300 276 642 to place a warranty service request and let the operator know whether you need Priority A or B service. More information can be found below.
  • Ensure you have the serial number of your product ready before contacting us.
  • The serial number of your product can be found on a compliance plate located on the inside right and at the rear of your cabinet.

BROMIC-REFRIGERATION-SVM1000SD-NR Semi-Verticals-and-Full-Height-Multidecks-
fig-1 \(13\)

SERVICE REQUEST PRIORITY

  • PRIORITY A SERVICE
    • When the unit is NOT performing its primary function such as cooling or heating, or presents an OH&S or food safety risk
  • PRIORITY B SERVICE
    • When the unit is performing its primary function, and presents no OH&S or food safety risk. i.e. lights, gaskets. locks, door adjustment
  • SERVICE CALL PLACED BEFORE MIDDAY
    • Priority A – Technician to attend site within 4 hours
    • Priority B – Technician to attend site within 8 business hours
  • SERVICE CALL PLACED AFTER MIDDAY
    • Priority A – The technician attends the site before midday on the following business day
    • Priority B – The technician attends the site before 4 pm on the following business day

CONTACT

  • BROMIC REFRIGERATION
  • 10 Phiney Place, Ingleburn (Sydney)
  • NSW 2565 Australia
  • T. 1300 276 642
  • For further product information bromicrefrigeration.com.au.

Note: Bromic Refrigeration reserves the right to make changes to specifications, parts, components, and equipment without prior notification. This Installation, operation, and service manual may not be reproduced in any form without prior written consent from Bromic Refrigeration.

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

BROMIC REFRIGERATION User Manuals

Related Manuals