HESSAIRE MC61M Evaporative Cooler
Safety Rules
- Read and follow all instructions, cautions, and warnings. Failure to do so could result in personal injury, death or property damage.
- Unit must be in the OFF position and UNPLUGGED from power receptacle before performing any maintenance.
- Make sure the electrical power source conforms to the requirement of the evaporative cooler(s) as well as local codes.
- To reduce the risk of fire or electrical shock, do not expose electrical connections to water.
- Do not touch electrically live components.
- Assure that all power cords do not meet any sharp edges, hot surfaces or chemicals. Immediately replace any damaged parts.
Key Operational Points
Your cooler must be positioned in front of an open window or door if it is to operate effectively. (see below picture)
- Always ensure that there is another open window or door through which the air can exhaust from the room.
- Ensure the rigid media is kept clean throughout the use of your cooler.
- At the end of each day run your cooler on FAN ONLY for 30 minutes to dry out the rigid media.
- Prior to putting your cooler away for winter, always:
a. Drain the tank and wipe clean.
b. Clean the rigid media.
c. Reassemble and run on FAN ONLY for 30 minutes to dry out the rigid media.
Indoor Use
CAUTION: BEFORE CLEANING OR SERVICING DISCONNECT POWER SUPPLY
Quick Start
After unpacking your evaporative cooler, carefully inspect for any damage that
may have occurred during transit. Inspect for loose, missing or damaged parts.
Contents: Evaporative cooler (1), Hardware Bag (1), Casters (4)
| | |
---|---|---|---
Lay the cooler
down| Unscrew the two
screws, remove
the bottom panel| Taks out: Casters x4
Screws x16
Garden Hose adaptor x1| Install 4 Casters
Features
MC37V / MC61V – Models Control Panel
Switch for Fan
Has 4 positions. (Clockwise from OFF) OFF, LOW, MED, HI.
Switch for Pump – Controls the pump
Switch for Swing – Controls the fan oscillation
MC37M / MC61M – Models Control Panel
Rotary Switch for Fan
Has 4 positions. (Clockwise from OFF) OFF, LOW, MED, HI.
Rocker Switch for Pump
Controls the pump
Rocker Switch for Swing
Controls the fan Oscillation
Rocker Switch for POWER
Main power control. When the power is turned to the “OFF” position, the other
controls will not work.
Hose Adapter
Our convenient hose adapter allows you to have continuous water fill on your cooler.
Air Intake
These coolers have 3 media panels instead of a single panel found on most mobile coolers. 3 panels allow more air-intake area and reduce pre-rotation of the air to the prop, which translates into lower static pressure and more efficient air delivery to the prop.
Cooler Maintenance
Use all precautions and disconnect from power source before performing any maintenance.
Cleaning Cooler and Rigid Media Pads
The removable panel and media pad can be sprayed out on the ground to clean pad. Use light pressure when spraying pads. You can use a soft bristle brush to gently wipe away deposits. NEVER spray pads with water while cooler is operating, and fan is running. This can cause damage to motor and will void the warranty.
Removal of the Back Panel (Disconnect power supply before this procedure.)
|
---|---
Unscrew the screws in the back panel first , then pull the back panel up.|
Pull out the bottom of the back panel then take it down .
Removal and Replacement of Cooling Media
- If your cooler includes media pins, remove by unscrewing/pulling out the disc.
- Remove media pad. Replace with new pad.
- Reinstall the back panel and you are ready to use the cooler again.
Go to www.hessaire.com for replacement videos and tips for eliminating any odor.
Draining the Cooler Tank
- Pull or unscrew drain plug/cap from drain assembly.
- Tip unit to ensure all water exits the unit.
- Replace drain plug.
Cooler Parts
Please visit www.hessaireparts.com to shop for cooler parts.
# | Parts | MC37 | MC61 |
---|---|---|---|
1 | Pump | 6036050 | 6060050 |
2 | Motor | 6037051 | 6061051 |
3 | Rigid Media Set | 6036053 | 6060053 |
4 | Control for V model | 6038069 | 6038069 |
Control for M model | 6037069 | 6037069 | |
5 | Casters | 6036061 | 6060061 |
6 | Casters w/lock | 6036062 | 6060062 |
7 | Fan Blade | 6037052 | 6061052 |
8 | Float Valve | 6018058 | 6018058 |
9 | Hose Adapter | 6018088 | 6018088 |
10 | Water Level Float | 6037059 | 6037059 |
11 | Oscillator Motor | 6037057 | 6037057 |
12 | Water Fill Door | 6037076 | 6037076 |
13 | Drain Plug | 6017081 | 6017081 |
Warranty Policy
Hessaire Products Inc. Manufacturing Warranty EVAPORATIVE COOLER
Each new cooler is warrantied to be free from defects in material or workmanship for one full year from the date of original purchase. If a component is found to be defective in this oneyear period, it will be repaired or replaced with a new or refurbished product at the option of the factory.
What is not covered by the warranty
- Malfunctions resulting from misuse, negligence, alteration or lack of necessary maintenance.
- Loss of time, inconvenience, use of product or other consequential damages due to defects.
- Return transportation costs. All return transportation costs are the responsibility of the purchaser.
- We do not provide maintenance personnel.
Damaged Shipments
Hessaire is not responsible for damaged shipments or shortages resulting from carrier mishandling. Notify your carrier’s office immediately to file a claim. Keep damaged goods and containers for inspection until advised by the carrier as to disposal.
Returns
All items must be returned with all original parts and packaging. Additional charges may apply for any missing or damaged parts.
The customer must re-package and ship their item(s) back to the manufacturer at their own expense.
No freight cost/shipping cost will be re-funded to the customer.
The customer needs to provide us with the tracking number of the shipment.
Upon receipt of the product, including original parts and packaging, we may issue a full refund for the product or may repair or replace the item with a new or refurbished product.
If our returns department finds that the item is not defective, you may be responsible for additional shipping costs as well as a 10-30% re-stocking fee.
Trouble Shooting
Problem | Cause/Remedy |
---|---|
1. Cooler fails to work at all |
- Check that the unit is plugged properly.
- Check the POWER switch, push it to “ON”.
- The TIMER switch is “OFF”, turn it to “ON”.
- Make sure cooler is not plugged into a tripped GFIC outlet. If so, reset GFCI or move to non GFCI outlet.
2. Cooler does not pump|
- Pump is not activated. Push the PUMP switch to “ON”.
- Water level is low. Fill with water and make sure pump is activated.
- Be sure the pump and pump hose are clear of debris.
- Pump may be defective. Replace pump. ***
3a. Fan does not operate
3b. Fan runs slow at start up|
- Check that unit is plugged properly.
- Check the POWER switch, push it to “ON”.
- If connected to a GFCI outlet, check if it is tripped.
- Troubleshoot rotary switch.***
- b Replace motor capacitor. ***
4. Louver does not operate|
- Louver does not move. Put swing switch position to “ON”.
- Check Oscillator motor for proper placement and operation.
5. Water leakage|
- Check the cap of the drain assembly, make sure it tightened.
- Inspect tank for cracks or breakage.
- Make sure cooler is level.
- Check media pads for buildup allowing water out on outside of pad frame — change media if needed.
- If water is coming out fan, check for leaks in water distribution hoses and/or leaks at hose connections to spreaders,
- Be sure there is at least 4 inches of space for rear panel free from wall or other obstruction. This could make the side panels release water to airstream due to increased air velocity through the sides.
- Spreaders may have scale buildup allowing water to pool and spill over into airstream—Clean spreaders.
6. Float Valve|
- If water levels are too high/low, adjust the wing nut on the valve.
- If there is a leak, check for cracks. Purchase new valve at www.hessaireparts.com
– See instructional videos for repairs and replacements at www.hessaire.com under the Media tab
Customer Support
Shop genuine replacement parts for HESSAIRE
MC61M
Find Your HESSAIRE Evaporative Cooler Parts – Select From 31
Models
11550 US Hwy 278 E Holly Pond, AL, 35083
Phone: (256)734-3003
Fax: (256)734-3201 www.Hessaire.com
References
- This is a temporary site. Go to the main site at hessaire.com
- Repair Your Grill: Shop Replacement Parts for 24,880 Models
- Hessaire Evaporative Cooler Parts - Select From 31 Models
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>