Russell RD17AZ24AJ3NA Vantix Line Side Discharge Universal Heat Pump
Product Information
Specifications
- Cooling Efficiencies : up to 19 SEER / 12 EER
- Heating Efficiencies : up to 8.5 HSPF
- Nominal Sizes: 2 to 5 Ton [7.0 to 17.6 kW]
- Cooling Capacities: 22.8 to 53.0 kBTU [6.7 to 15.5 kW]
- Refrigerant Type : R-410A
Product Usage Instructions
Proper Sizing and Installation
Proper sizing and installation of the equipment are crucial for achieving
optimal performance. Split system air conditioners and heat pumps must be
matched with appropriate coil components to meet Energy Star requirements.
Standard Equipment
- R-410A Refrigerant
- Rotary Compressor
- Field Installed Filter Drier
- Low Ambient Control
- Compressor Sound Cover
- Low-Pressure Control
- Front Seating Service Valves
- Internal Pressure Relief Valve
- Easy Access to Internal Components
- Optimized Venturi Airflow
- Powder Coated Paint
- Rust Resistant Screws
- QR Code
- External Gauge Ports
General Data/Electrical Data
- Model No.: RD17AZ24AJ3NA
- Nominal Tonnage : 2.0T
- Valve Connections : 3/8, 3/4
- Number of Blades : 81
- Motor hp : 11.0
- CFM : 3175
- RPM : 550
- Watts : 115
Accessories/Weighted Sound Power
Compressor Crankcase Heater, Basepan Heater, Low Ambient Control, Compressor
Sound Cover, Compressor Hard Start Kit, Low-Pressure Control, High-Pressure
Control, Liquid Line Solenoid (24 VAC, 50/60 Hz), Liquid Line Solenoid
(120/240 VAC, 50/60 Hz), Solenoid Valve, Solenoid Coil
RD17AZ
- Cooling Efficiencies up to 19 SEER2/12 EER2
- Heating Efficiencies up to: 8.5 HSPF2
- Nominal Sizes: 2 to 5 Ton [7.0 to 17.6 kW]
- Cooling Capacities 22.8 to 53.0 kBTU [6.7 to 15.5 kW]
- Refrigerant Type : R-410A
Features and Benefits
-
Flexible & Universal Install Compatibility:
-
Works with nearly any HVAC System – including Russell® By Rheem EcoNet® Enabled systems and non-communicating systems
-
Install with any indoor system component via a Russell® By Rheem algorithm
( IMPORTANT : the indoor system component CFM must match the requirement of the outdoor system component) -
Install as a Universal Replacement with minimal alterations (coil only – with TXV)
-
-
Space Saver Solution: The RD17AZ – with footprint options as low as 36.6″ tall and 40.2″ wide – is ideal for when installation locations are constrained; but is also perfect for any system or replacement option where an efficient, streamlined look is desired
-
Quiet Operation as low as 58dB1 : Offers sound dampening features such as a sound blanket, refrigerant tubing design, fan blade approach and innovative compressor and drive technologies – ensure that as efficiency goes up, sound levels stay low
-
EcoNet® Enabled2: Automatic system configuration and optimization
-
Diagnostics & Bluetooth®3, 4 Connectivity: With the Russell® By Rheem Contractor & EcoNet® Apps, builtin technology makes advanced set-up, monitoring, troubleshooting, and repairing the product easier than ever before
-
Variable Speed Twin Rotary Compressor & Inverter Drive:
- Features variable speed operation from 45 to 100% capacity with the EcoNet® Smart Thermostat or with legacy and other thermostats when the utility 1 & 2 jumpers are installed or using the Russell® By Rheem algorithm5
- Provides precise temperature control, advanced humidity control and greater efficiency
-
Brushless DC Condenser Motors (BLDC) : Enhances reliability and allows for easier serviceability
-
Swept Wing Fan Technology: Features quieter operation and improved unit acoustics
-
7mm Condenser Copper Coil: Requires less refrigerant allowing for a smaller and lighter footprint while enhancing reliability
-
Optional Base Pan Heater: Utilizes a built-in thermostat to regulate the heating operation to prevent ice build-up on the base pan during extreme cold weather conditions
-
Traditional Refrigerant Piping: Allows for use of existing refrigerant line sets for further ease of replacement installation flexibility
-
10-Year Conditional Parts Warranty (registration required): Coverage when installed as a heat pump only or as part of a system
- with no AHRI matched system requirement
-
Qualifies for Federal Incentives (conditions apply):
- Federal Tax Credit compliant system combinations across all product tonnages (effective through 12/31/32) – up to $2000 for qualified heat pumps
- Visit RussellByRheem.com/Federal-Incentives
- Based on Internal R&D Testing, 2023 Sound levels are also dependent on proper installation and location of outdoor product.
- When installed as part of a complete AHRI-matched, Russell® By Rheem EcoNet® Enabled system.
- The Bluetooth® word mark and logos are registered trademarks owned by Bluetooth SIG, Inc. and any use of such marks by Rheem® is under license. Other trademarks and trade names are those of their respective owners.
- When installed as part of a complete Russell® By Rheem system where both the outdoor & indoor components feature Bluetooth® Technology.
- Two-Stage (70% &100% capacity) operation when installed with legacy and other thermostats when the utility 1 & 2 jumpers are not installed. The 2-Ton model features a single rotary compressor.
Heat Pumps
[ ] Designates Metric Conversions AVAILABLE MODELS | DESCRIPTION |
---|---|
RD17AZ24AJ3NA | Vantix™ Line 2 Ton R-410A Universal Heat Pump |
RD17AZ36AJ3NA | Vantix™ Line 3 Ton R-410A Universal Heat Pump |
RD17AZ48AJ3NA | Vantix™ Line 4 Ton R-410A Universal Heat Pump |
RD17AZ60AJ3NA | Vantix™ Line 5 Ton R-410A Universal Heat Pump |
NOTE : RD17AZ models are communicating when installed as part of a complete AHRI-matched, Russell® By Rheem EcoNet® Enabled System
STANDARD EQUIPMENT
- R-410A Refrigerant
- Rotary Compressor
- Field Installed Filter Drier
- Low Ambient Control
- Compressor Sound Cover
- Low Pressure Control
- Front Seating Service Valves
- Internal Pressure Relief Valve
- Easy Access to Internal Components
- Optimized Venturi Airflow
- Powder Coated Paint
- Rust Resistant Screws
- QR Code
- External Gauge Ports
General Data
General Data
MODEL NO.| RD17AZ24AJ3NA| RD17AZ36AJ3NA|
RD17AZ48AJ3NA| RD17AZ60AJ3NA
Nominal Tonnage| 2.0T| 3.0T| 4.0T| 5.0T
Valve Connections|
Liquid Line O.D. – in.| 3/8| 3/8| 3/8| 3/8
Suction Line O.D. – in.| 3/4| 3/4| 7/8| 7/8
Refrigerant (R410A) furnished oz.¹| 81| 116| 222| 236
Compressor Type|
Outdoor Coil|
Net face area – Outer Coil (Sq. Ft.)| 11.0| 15.1| 17.2| 17.2
Net face area – Inner Coil (Sq. Ft.)| N/A| 15.1| 17.2| 17.2
Tube diameter – in.| 0.276| 0.276| 0.276| 0.276
Number of rows| 1| 2| 3| 3
Fins per inch| 18| 18| 16| 16
Outdoor Fan|
Diameter – in.| 26| 28| 24| 24
Number of blades| 3| 3| 3| 3
Motor hp| 1/2| 1/2| 1/3| 1/3
Nos| 1| 1| 2| 2
CFM| 3175| 3575| 5150| 5600
RPM| 550| 570| 650| 700
Watts| 115| 215| 315| 365
Shipping weight – lbs.| 205| 271| 354| 356
Operating weight – lbs.| 146| 200| 278| 280
Electrical Data
Electrical Data
Line Voltage Data (Volts-Phase-Hz)| 208/230-1-60|
208/230-1-60| 208/230-1-60| 208/230-1-60
Maximum overcurrent protection (amps)²| 20.0| 25.0| 40.0|
45.0
Minimum circuit ampacity³| 19.0| 24.5| 38.0| 41.0
Compressor|
Rated load amps| 9.7| 10.4| 17.0| 22.0
Locked rotor amps| 25| 52| 51| 51
Condenser Fan Motor|
Full load amps| 3.0| 3.0| 2.5| 2.5
Locked rotor amps| 6.4| 6.4| 4.1| 4.1
- Refrigerant charge sufficient for 15 ft. length of refrigerant lines. For longer line set requirements see the installation instructions for information about set length and additional refrigerant charge required.
- HACR type circuit breaker of fuse.
- Refer to National Electrical Code manual to determine wire, fuse and disconnect size requirements.
Accessories
MODEL NO.| RD17AZ24AJ3NA| RD17AZ36AJ3NA|
RD17AZ48AJ3NA| RD17AZ60AJ3NA
---|---|---|---|---
Compressor crankcase heater*| 44-103663-15| 44-103663-15| 44-103663-15|
44-103663-15
Basepan heater| 44-109957-01| 44-109958-01| 44-109957-01| 44-109957-01
Low ambient control| Included Standard| Included Standard| Included Standard|
Included Standard
Compressor sound cover| Included Standard| Included Standard| Included
Standard| Included Standard
Compressor hard start kit| N/A| N/A| N/A| N/A
Low pressure control| Included Standard| Included Standard| Included Standard|
Included Standard
High pressure control| Included Standard| Included Standard| Included
Standard| Included Standard
Liquid Line Solenoid (24 VAC, 50/60 Hz)| Solenoid Valve| 200RD2T3TVLC|
200RD2T3TVLC| 200RD2T3TVLC| 200RD2T3TVLC
Solenoid Coil| 61-AMG24V| 61-AMG24V| 61-AMG24V| 61-AMG24V
Liquid Line Solenoid (120/240 VAC, 50/60 Hz)| Solenoid Valve| 200RD2T3TVLC|
200RD2T3TVLC| 200RD2T3TVLC| 200RD2T3TVLC
Solenoid Coil| 61-AMG120/240V| 61-AMG120/240V| 61-AMG120/240V| 61-AMG120/240V
Weighted Sound Power Level (dBA)
UNIT SIZE – VOLTAGE, SERIES| STANDARD RATING (dBA)| SOUND
POWER AS LOW AS| TYPICAL OCTAVE BAND SPECTRUM (dBA
WITHOUT TONE ADJUSTMENT)
---|---|---|---
125| 250| 500| 1000| 2000| 4000| 8000
RD17AZ24| 68| 61| 45.0| 54.7| 57.5| 58.2| 53.9| 46.7| 38.1
RD17AZ36| 69| 58| 44.7| 60.8| 62.3| 57.2| 53.9| 54.5| 44.8
RD17AZ48| 74| 61| 54.0| 58.6| 63.8| 64.9| 60.4| 54.8| 44.9
RD17AZ60| 73| 63| 53.5| 59.0| 62.6| 63.3| 57.9| 50.4| 44.8
NOTE : Tested in accordance with AHRI Standard 270-08 (not listed in AHRI)
Unit Dimensions
MODEL NO.
| OPERATING| SHIPPING
---|---|---
H (Height)| L (Length)| W (Width)| H
(Height)| L (Length)| W (Width)
INCHES| mm| INCHES| mm| INCHES| mm| INCHES|
mm| INCHES| mm| INCHES| mm
RD17AZ24AJ3NA| 36.61| 930| 40.16| 1020| 16.38| 416| 43.31| 1100| 48.43| 1230|
22.05| 560
RD17AZ36AJ3NA| 46.38| 1178| 42.01| 1067| 19.29| 490| 53.94| 1370| 50.00| 1270|
25.00| 635
RD17AZ48AJ3NA| 57.80| 1468| 40.16| 1020| 16.38| 416| 65.16| 1655| 48.43| 1230|
22.05| 560
RD17AZ60AJ3NA| 57.80| 1468| 40.16| 1020| 16.38| 416| 65.16| 1655| 48.43| 1230|
22.05| 560
[ ] Designates Metric Conversions
Refrigerant Line Size Information
17 SEER2 VARIABLE SPEED HEAT PUMPS
UNIT SIZE
| ****
ALLOWABLE LIQUID LINE SIZE
| ****
ALLOWABLE VAPOR LINE SIZE
| OUTDOOR UNIT ABOVE OR BELOW INDOOR UNIT EQUIVALENT LENGTH (FEET)
< 25| 26- 50| 51- 75| 76- 100| 101-
125| 126- 150
MAXIMUM VERTICAL SEPARATION/CAPACITY MULTIPLIER
2.0 TON
*SEE NOTE 3
| 1/4″| 5/8″| 25/1.00| 50/0.99| 33/0.98| 60/0.97| NR| NR
5/16″| 5/8″| 25/1.00| 50/0.99| 50/0.98| 50/0.97| 50/0.96| 50/0.95
3/8″| 5/8″| 25/1.00| 50/0.99| 50/0.98| 50/0.97| 50/0.96| 50/0.95
1/4″| 3/4″| 25/1.00| 50/1.00| 33/0.99| 60/0.99| NR| NR
5/16″| 3/4″| 25/1.00| 50/1.00| 50/0.99| 50/0.99| 50/0.99| 50/0.98
3/8″| 3/4″*| 25/1.00| 50/1.00| 50/0.99| 50/0.99| 50/0.99| 50/0.98
3 TON
| 5/16″| 5/8″| 25/0.99| 50/0.97| 50/0.95| 50/0.93| 36/0.91| NR
3/8″| 5/8″| 25/0.99| 50/0.97| 50/0.95| 50/0.93| 50/0.91| NR
5/16″| 3/4″| 25/1.00| 50/0.99| 50/0.99| 50/0.98| 36/0.97| 20/0.96
3/8″| 3/4″| 25/1.00| 50/0.99| 50/0.99| 50/0.98| 50/0.97| 50/0.96
1/2″| 3/4″| 25/1.00| 50/0.99| 50/0.99| 50/0.98| 50/0.97| 50/0.96
4 TON
| 3/8″| 3/4″| 25/0.99| 50/0.98| 50/0.96| 50/0.95| 50/0.93| 50/0.92
1/2″| 3/4″| 25/0.99| 50/0.98| 50/0.96| 50/0.95| 50/0.93| 50/0.92
3/8″| 7/8″| 25/1.00| 50/0.99| 50/0.99| 50/0.98| 50/0.98| 50/0.97
1/2″| 7/8″| 25/1.00| 50/0.99| 50/0.99| 50/0.98| 50/0.98| 50/0.97
5 TON
| 3/8″| 3/4″| 25/0.98| 50/0.97| 50/0.95| 50/0.93| 46/0.91| NR
1/2″| 3/4″| 25/0.98| 50/0.97| 50/0.95| 50/0.93| 50/0.91| NR
3/8″| 7/8″| 25/0.99| 50/0.99| 50/0.98| 50/0.97| 50/0.96| 38/0.95
1/2″| 7/8″| 25/0.99| 50/0.99| 50/0.98| 50/0.97| 50/0.96| 50/0.95
3/8″| 1-1/8″| 25/1.00| 50/1.00| 50/1.00| 50/0.99| 50/0.99| 38/0.99
1/2″| 1-1/8″| 25/1.00| 50/1.00| 50/1.00| 50/0.99| 50/0.99| 50/0.99
NOTES:
- Do not exceed 150 ft. linear line length.
- Do not exceed 50 ft. vertical separation between indoor and outdoor units.
- *3/4″ vapor line should only be used for 2 ton systems if outdoor unit is below or at same level as indoor unit to assure proper oil return.
- **1-1/8″ vapor line should only be used for 5 ton systems if outdoor unit is below or at same level as indoor unit to assure proper oil return.
- Always use the smallest liquid line allowable to minimize refrigerant charge.
- Applications shaded in light gray indicate capacity multipliers between 0.90 and 0.96 which are not recommended, but are allowed.
- Applications shaded in dark gray are not recommended due to excessive liquid or suction pressure drop.
17 SEER2 VARIABLE SPEED HEAT PUMPS
UNIT SIZE
| ****
ALLOWABLE LIQUID LINE SIZE
| ****
ALLOWABLE VAPOR LINE SIZE
| OUTDOOR UNIT ABOVE OR BELOW INDOOR UNIT EQUIVALENT LENGTH (METERS)
< **8| 9- 15| 16- 23| 24- 30| 31-
38| 39- 46
MAXIMUM VERTICAL SEPARATION/CAPACITY MULTIPLIER**
7.0 kW [2.0 TON]
*SEE NOTE 3
| 6.35 [1/4]| 15.88 [5/8]| 8/1.00| 15/0.99| 10/0.98| 20/0.97| NR|
NR
7.94 [5/16]| 15.88 [5/8]| 8/1.00| 15/0.99| 15/0.98| 15/0.97| 15/0.96| 15/0.95
9.53 [3/8]| 15.88 [5/8]| 8/1.00| 15/0.99| 15/0.98| 15/0.97| 15/0.96| 15/0.95
6.35 [1/4]| 19.05 [3/4]| 8/1.00| 15/0.99| 10/0.99| 20/0.99| NR| NR
7.94 [5/16]| 19.05 [3/4]| 8/1.00| 15/0.99| 15/0.99| 15/0.99| 15/0.99| 15/0.98
9.53 [3/8]| 19.05 [3/4]| 8/1.00| 15/0.99| 15/0.99| 15/0.99| 15/0.99| 15/0.98
10.6 kW [3 TON]
| 7.94 [5/16]| 15.88 [5/8]| 8/0.99| 15/0.97| 15/0.95| 15/0.93| 11/0.91|
NR
9.53 [3/8]| 15.88 [5/8]| 8/0.99| 15/0.97| 15/0.95| 15/0.93| 15/0.91| NR
7.94 [5/16]| 19.05 [3/4]| 8/1.00| 15/0.99| 15/0.99| 15/0.98| 11/0.97| 6/0.96
9.53 [3/8]| 19.05 [3/4]| 8/1.00| 15/0.99| 15/0.99| 15/0.98| 15/0.97| 15/0.96
12.70 [1/2]| 19.05 [3/4]| 8/1.00| 15/0.99| 15/0.99| 15/0.98| 15/0.97| 15/0.96
14.1 kW [4 TON]
| 9.53 [3/8]| 19.05 [3/4]| 8/0.99| 15/0.98| 15/0.96| 15/0.95| 15/0.93| 15/0.92
12.70 [1/2]| 19.05 [3/4]| 8/0.99| 15/0.98| 15/0.96| 15/0.95| 15/0.93| 15/0.92
9.53 [3/8]| 22.23 [7/8]| 8/1.00| 15/0.99| 15/0.99| 15/0.98| 15/0.98| 15/0.97
12.70 [1/2]| 22.23 [7/8]| 8/1.00| 15/0.99| 15/0.99| 15/0.98| 15/0.98| 15/0.97
17.6 kW [5 TON]
| 9.53 [3/8]| 19.05 [3/4]| 8/0.98| 15/0.97| 15/0.95| 15/0.93| 14/0.91| NR
12.70 [1/2]| 19.05 [3/4]| 8/0.98| 15/0.97| 15/0.95| 15/0.93| 15/0.91| NR
9.53 [3/8]| 22.23 [7/8]| 8/0.99| 15/0.99| 15/0.98| 15/0.97| 15/0.96| 12/0.95
12.70 [1/2]| 22.23 [7/8]| 8/0.99| 15/0.99| 15/0.98| 15/0.97| 15/0.96| 15/0.95
9.53 [3/8]| 28.58 [1-1/8]| 8/1.00| 15/0.99| 15/0.98| 15/0.99| 15/0.99|
12/0.99
12.70 [1/2]| 28.58 [1-1/8]| 8/1.00| 15/0.99| 15/0.98| 15/0.99| 15/0.99|
15/0.99
NOTES:
- Do not exceed 46 meters linear line length.
- Do not exceed 15 meters vertical separation between indoor and outdoor units.
- *19.05 mm [3/4 in.] vapor line should only be used for 2 ton systems if outdoor unit is below or at same level as indoor unit to assure proper oil return.
- **28.58 mm [1-1/8 in.] vapor line should only be used for 5 ton systems if outdoor unit is below or at same level as indoor unit to assure proper oil return.
- Always use the smallest liquid line allowable to minimize refrigerant charge.
- Applications shaded in light gray indicate capacity multipliers between 0.90 and 0.96 which are not recommended, but are allowed.
- Applications shaded in dark gray are not recommended due to excessive liquid or suction pressure drop.
Performance Data @ AHRI Standard Conditions – Cooling
DESIGNATED TESTED COMBINATION (DTC)
OUTDOOR UNIT
| ****
COIL
| ****
TOTAL CAPACITY BTU/H [KW]
| ****
NET SENSIBLE BTU/H [KW]
| ****
NET LATENT BTU/H [KW]
| ****
SEER2
| ****
EER2
| ****
INDOOR CFM [L/S]
| 47 DEGREE HEATING CAPACITY BTU/H [KW]| ****
47
DEGREE COP
| 17 DEGREE HEATING CAPACITY BTU/H [KW]| ****
17
DEGREE COP
| ****
REGION IV HSPF2
RD17AZ24AJ3NA| TCFZ2417MTANMC| 22,800 [6.7]| 16,880 [5.0]| 5,920 [1.7]| 14.3|
9.8| 750 [354]| 22,800 [6.7]| 3.30| 16,000 [4.7]| 2.56| 7.5
RD17AZ36AJ3NA| TCFZ3621MTANMC| 34,200 [10.0]| 24,238 [7.1]| 9,962 [2.9]| 14.3|
9.8| 1,025 [484]| 34,200 [10.0]| 3.48| 23,000 [6.7]| 2.62| 7.5
RD17AZ48AJ3NA| TCFZ4824MTANMC| 45,000 [13.2]| 31,760 [9.3]| 13,240 [3.9]|
14.3| 9.8| 1,250 [590]| 45,000 [13.2]| 3.42| 33,000 [6.7]| 2.66| 7.5
RD17AZ60AJ3NA| TCFZ6024STANMC| 53,000 [15.5]| 36,263 [10.6]| 16,737 [4.9]|
14.3| 9.8| 1,450 [684]| 53,000 [15.5]| 3.36| 36,500 [10.7]| 2.50| 7.5
DESIGNATED TESTED COMBINATION (DTC)
OUTDOOR UNIT
RD17AZ24AJ3NA
| ****
AIR HANDLER
SH3VZ3617STACNJ
| ****
TOTAL CAPACITY BTU/H [KW]
22,600 [6.6]
| ****
NET SENSIBLE BTU/H [KW]
17,500 [5.1]
| ****
NET LATENT BTU/H [KW]
5,300 [1.6]
| ****
SEER2
19.0
| ****
EER2
10.0
| ****
INDOOR CFM [L/S]
725 [342.0]
| 47 DEGREE HEATING CAPACITY BTU/H [KW]
22,600 [6.6]
| ****
47
DEGREE COP
2.90
| 17 DEGREE HEATING CAPACITY BTU/H [KW]
18,700 [5.5]
| ****
17
DEGREE COP
2.50
| ****
REGION IV HSPF2
8.1
RD17AZ36AJ3NA| SH3VZ4821STACNJ| 34,200 [10.0]| 26,200 [7.7]| 8,000 [2.3]|
18.0| 11.7| 1,050 [495.0]| 34,200 [10.0]| 2.78| 31,200 [9.1]| 2.30| 8.1
RD17AZ48AJ3NA| SH3VZ6024STACNJ| 45,500 [13.3]| 34,900 [10.2]| 10,600 [3.1]|
17.0| 11.7| 1,375 [649.0]| 45,500 [13.3]| 2.94| 43,000 [12.6]| 2.40| 8.1
RD17AZ60AJ3NA| SH3VZ6024STACNJ| 55,500 [16.3]| 42,600 [12.5]| 12,900 [3.8]|
19.0| 10.0| 1,500 [707.9]| 53,500 [15.7]| 2.32| 50,000 [14.7]| 2.00| 8.1
NOTE : This data includes DTC (Designated Test Combination) ratings and is for reference purposes only. A full listing of official ratings and system match-ups, along with downloadable certificates, can be accessed from the AHRI website : www.ahridirectory.org.
GENERAL TERMS OF LIMITED WARRANTY*
Russell® By Rheem will furnish a replacement for any part of this product which fails in normal use and service within the applicable period stated, in accordance with the terms of the limited warranty. *For complete details of the Limited and Conditional Warranties, including applicable terms and conditions, contact your local contractor or the Manufacturer for a copy of the product warranty certificate.
Conditional Parts
(Registration Required)……………………………. Ten (10) Years
Applies to a heat pump only or system installation. Does not require the heat
pump to be part of a properly matched system as specified by the Manufacturer
and the Air Conditioning Heating & Refrigeration Institute (AHRI).
Before proceeding with installation, refer to installation instructions packaged with each model, as well as complying with all Federal, State, Provincial, and Local codes, regulations, and practices.
© 2024 Rheem Manufacturing Company. Russell By Rheem trademarks owned by Rheem Manufacturing Company.
In keeping with its policy of continuous progress and product improvement, Russell by Rheem reserves the right to make changes without notice.
5600 Old Greenwood Road
- Fort Smith, Arkansas 72908
- www.russellbyrheem.com
FAQ
Q: How do I select the correct size for my heat pump?
A: Proper sizing of the equipment is essential for optimal performance.
Consult with your contractor to ensure the heat pump is matched with
appropriate coil components.
Q: What refrigerant type does the heat pump use?
A: The heat pump uses R-410A refrigerant.
Q: Where can I find more information about Energy Star requirements?
A: For more details on Energy Star requirements, visit
www.energystar.gov or consult with your
contractor.