PURMO M16MI419 Advanced Thermostat Instruction Manual
- July 26, 2024
- PURMO
Table of Contents
- PURMO M16MI419 Advanced Thermostat
- Product Usage Instructions
- OPERATION
- BOOST FEATURE
- CHILD ANTI-TAMPER, KEYPAD LOCK/UNLOCK
- DAY AND DAILY PROGRAMME
- Choices programmes
- Programmes overview
- Choices and allocation programmes
- OPEN WINDOW DETECTION, ENERGY SAVINGS
- Lowering the temperature during unoccupied periods
- Operation
- INFORMATION ABOUT REMOTE CONTROL BY PILOT WIRE
- INFORMATION ABOUT PRIORITIES BETWEEN THE DIFFERENT MODES
- RESTORING FACTORY SETTINGS
- TECHNICAL SPECIFICATIONS
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
PURMO M16MI419 Advanced Thermostat
Technical Specifications
- Model: M16MI419 – A06-06/18
- Device Type: Advanced Thermostat
Product Usage Instructions
-
Restoring Factory Settings
To restore factory settings, refer to page 16 of the manual. -
Expert Settings
For expert settings, please follow the instructions provided on page 17.
Operation
Follow the operation diagram given in the manual for power on/standby mode
functionality.
Power On/Standby Mode
- Power On Feature: Press the button to put the device in operation, in Auto mode.
- Standby Mode: Press the button to put the device in standby mode to stop heating, e.g., during summer.
- Selecting the Operating Mode
Press the mode button to select the required mode. The device offers Auto, Comfort, Eco, and Frost Protection modes.
Mode Overview
- Auto Mode: Automatically switches between Comfort and Eco modes based on the established program.
- Comfort Mode: Executing Comfort and Eco mode orders according to programmed settings and time periods.
- Eco Mode: Orders sent by the pilot wire will be applied in Auto mode, receiving programmed orders sent by the power manager or time switches.
FAQ
Frequently Asked Questions
-
How do I restore factory settings?
To restore factory settings, refer to page 16 of the manual. -
What are the different operation modes available?
The device offers Auto, Comfort, Eco, and Frost Protection modes. Each mode serves specific purposes based on user requirements. -
How do I know if the device is in operation or standby mode?
The device emits different sound signals to indicate its current mode – 2 short beeps for operation (Auto mode) and 1 short beep for standby mode.
MAINTENANCE MANUAL
ADVANCED THERMOSTAT
Reduced version
OPERATION
DIAGRAM
- Buttons overview
- Occupancy detector
- Selecting operating modes
- Plus and minus buttons, used to set temperatures, time, date and 3 2 programmes
- Save settings
- Button power on/standby mode
- Boost
- Indicators overview
- boost indicator light
- Gauge consumption
- Heating indicator
- Days of the week (1=Monday … 7= Sunday)
- Setting temperature
- Occupancy detection indicator
- Open window detection indicator
- Keypad locked
- Radio transmission indicator
- Operation modes:
- Important: In Auto, Comfort, Eco and Standby mode, backlight turns off automatically after 20 seconds if no buttons are pressed. It will be necessary to reactivate it by pressing one of the keypad buttons before making settings.
- Before carrying out any setting procedures, ensure that the keypad is indeed unlocked (see page 6).
POWER ON/STANDBY MODE
Power on feature
Press the button to put the device in operation, in Auto mode.
- Help for the visually impaired: sound signals
- The device makes 2 short beeps to notify that it is in operation, in Auto mode.
Standby mode
-
This function allows you to stop the heating in summer, for example. Press the ****button to put the device in standby mode.
-
Help for the visually impaired: sound signals The device makes 1 short beep to notify that it is in standby mode.
SELECTING THE OPERATING MODE
- The button allows you to adapt the operating schedule of your device to your needs, depending on the sea-son, whether your home is occupied or not.
- Press the button several times to select the required mode
Mode sequence:
Mode overview
-
Auto mode
In Automatic Mode, the device will automatically change from Comfort mode to Eco mode according to the established programme. -
2 different cases depending on your set-up:
-
1 7 day and daily programme
Your device has been programmed and is executing Comfort and Eco mode orders in line with the settings and time periods you have selected (see “7 day and daily programme integrated” chapter page 7). -
Display
-
Mode overview Display
-
Programming by pilot wire
-
If you do not want to use the programming feature.
-
Orders sent by the pilot wire will only be applied in Auto mode, thus your device will automatically receive and apply the programmed orders sent by your power manager or your time switches (see \
-
Information about remote control by pilot wire page 10).
Restoring factory settings See page 14,16 and 19.
BOOST FEATURE
-
Important: the Boost mode can be enabled at any time, whatever the current operating mode (Auto, Comfort, Eco or Frost protection).
-
To activate Boost mode, press , the desired temperature setting will be set at maximum for the time period you request. 60 minutes display will flash by default.
-
First press = Boost.
-
During the first minute: the boost symbol and the heating indicator ap-pear and the duration count flash.
-
During the first minute, you can modify the Boost duration from 0 to the maximal authorised duration of the Boost, such as defined during the advanced settings (see page 13 for more details) by intervals of 5 minutes (or more quickly by push superior to 2 seconds) by pressing . This modification will be saved and effective for the next Boost.
-
After 1 minute, the Boost count begins and the time is running, minute by minute.
-
Comment: After 1 minute, you can modify temporarily the duration: it will be valid only for this active Boost and therefore non-recurring.
The Boost can stop for 2 different reasons:
-
An order “Stop” has been sent by your energy manager through the pilot wire:
-
The device stops, — appears. The cursor moves above auto. When the order Comfort will be sent, the device will be restarted until the count end.
-
If the ambient temperature reaches the maximal Boost temperature during the count:
-
The device switches off but the Boost mode is always active : the count is always displayed, the Boost symbol and the heating indicator flash on the display. When the temperature drops under the maximal authorised temperature, the device will be restarted until the count ends.
-
Second press = Boost cancellation.
The cursor moves above the previous active mode and the setting temperature appears.
GAUGE CONSUMPTION, ENERGY SAVINGS
- FRANCE’S AGENCY FOR ENVIRONMENT AND ENERGY MANAGE-MENT (ADEME) RECOMMENDS A COMFORT SETTING TEMPERATURE LOWERR OR EQUAL TO 19°C.
- In the device display, a selector indicates the energy consumption level by positioning it in front of the colour: red, orange or green. So, depending on the setting temperature, you can choose your level of energy usage. As the temperature setting increases, the consumption will be higher.
- The gauge appears in Auto, Comfort, Eco and Frost protection modes and whatever the temperature level.
SETTING THE COMFORT MODE TEMPERATURE
- You can access the Comfort temperature set up from the Auto and Comfort Mode. It is preset to 19°C.
- Using you can adjust the temperature from 7°C to 30°C by intervals of 0.5° C.
- Note : you can limit the Comfort temperature, see page 13 for more details.
CONSUMPTION INDICATION ACCUMULATED IN KWH, ENERGY SAVINGS
- It is possible to see the estimation of energy consumption in kWh since the last reset of the energy meter.
- Display of the estimated power consumption
- To see this estimation, from Auto, Comfort, Eco or Frost protection mode, then press .
- To exit the display mode of consumption: press any button, the device is automatically in the previous active mode.
Resetting the energy meter
To reset the energy meter, from Auto, Comfort, Eco or Frost protection
mode, then proceed as follows.
- Press .
- Press simultaneously for more than 5 seconds.
To exit resetting the energy meter, press any button, the device is automatically in the previous active mode.
CHILD ANTI-TAMPER, KEYPAD LOCK/UNLOCK
-
Keypad lock
-
To lock the keypad, press the buttons and hold them down for 10 seconds. The padlock symbol appears on the display, the keypad is locked.
-
Keypad unlock
To unlock the keypad, press the buttons hold them down for 10 seconds again. The padlock symbol disappears from the display, keypad is unlocked. -
When keypad is locked, only the key is active.
If the device is on Standby mode when the keypad is locked, you have to unlock it for the next heating on to access the setup.
DAY AND DAILY PROGRAMME INTEGRATED, ENERGY SAVINGS AUTOMATIC PROGRAMMING WITH SELF-LEARNING PROCESS
- Overview
Auto-programming (Auto): After an initial learning period of one week, the device will analyze occupancy cycles to determine and implement a weekly programme adapted to your lifecycle alternating periods in comfort and periods in eco, the goal being to deliver the most efficient yet comfortable and user focused heating cycle. The products algorithm will perpetually learn and adapt to changes in your occupancy patterns, adapting week after week to optimize the heating programme to any changes in your evolving occupancy patterns.
Operating
- Upon the first activation of your device, the mode “auto-programme” is activated by default, in mode Auto. To deactivate and change the programme, see choice and affectation of programmes page 8.
- The first week of operation is a learning week during which the device memorizes your habits and elaborates a program for the week.
- It therefore defines a programme built up of periods of Comfort and Eco, independently for each day of the week.
- During this learning week, the device will provisionally function in permanent “Comfort” mode
- Important : To ensure the auto-programming is optimized, please en-sure the presence detection sensor is not interrupted by an external source, see important information concerning the presence detection system on page 9.
- Application of the intelligent program
- One week after switching on, the device will apply the new program for the next 7 days. Then week after week the device will continue to optimize the intelligent program “Auto”, adjusting the Comfort and Eco periods to fit closely to your lifestyle.
- When the product is in Frost protection mode or in standby mode for more than 24 hours, learning and optimization of the intelligent program stops: the device stores the previously recorded program from the last week before switching to the Frost protection or standby mode.
- Example 1: If the product is installed in mid-season or if its installation is anticipated on the construction site, it can be switched on in standby mode. When you select the Auto mode, the learning week will start automatically. The device will be in permanent comfort and will memorize your habits to apply the adapted program the fol- lowing week.
- Example 2: You select frost protection mode before going on holiday. Upon your return, when you return to Auto mode, the unit will automatically apply the previously stored intelligent program from the last week before you left.
- In the case of control by pilot wire coming from an energy manager for example, the pilot wire will take precedence over the AUTO program which results from the Self-learning algorithm.
DAY AND DAILY PROGRAMME
In this mode, you have the option of programming your device, by setting one of the five programmes on offer for each day of the week.
- Access to the programming mode
- From Auto, Comfort, Eco or Frost protection mode, press or 5 seconds to enter into the programming mode.
Schematic sequence of programming settings:
Setting day and time
In this mode, you can set day and time to program your device in line with
your needs.
-
From Auto, Comfort, Eco or Frost protection mode, press for 5 seconds.
The cursor moves to the setting day and time mode. -
Select using . The two hour figures will flash.
The hours will scroll quickly, if you press the hold them.
Save by pressing . -
The two minute figures will flash.
Select using or . Save by pressing -
The cursor above the number 1 (which represents the Monday) will flash. Select the date using or
Save by pressing . -
To change and/or allocate programmes press . To exit the setting the time and day mode, press 3 times.
Choices programmes
Schematic sequence of programmes:
The device is delivered by default with the self-learning mode enabled as described on page 7. If this programme suits your requirements, you have nothing more to do, the device, after the initial 7 day learning period will follow the auto programme which will continue to tailor itself to your occupancy cycles.
Programmes overview
- Auto: Auto-programming (See Automatic programming with self learning process page 6).
- Comfort: your device will operate in Comfort mode, 24 hours a day, as regards each day selected.
- Note: You can set the Comfort mode temperature to the temperature you require (see the Setting the Comfort mode temperature section page 6).
- Eco: The device will operate 24 hours a day in Eco mode.
- Note: You can set the temperature-lowering parameters (see page 12). P1: your device will operate in Comfort mode from 06:00 to 22:00 (and in Eco mode from 22:00 to 06:00).
- P2: your device will operate in Comfort mode from 06:00 to 09:00 and from 16:00 to 22:00 (and in Eco mode from 09:00 to 16:00 and from 22:00 to 06:00).
- P3: your device will operate in Comfort mode from 06:00 to 08:00, from 12:00 to 14:00 and from 18:00 to 23:00 (and in Eco mode from 23:00 to 06:00, from 08:00 to 12:00 and from 14:00 to 18:00).
Potential modifications of programmes
If the default time schedules for the P1, P2 and P3 programmes does not suit
your routines, you can change them.
Modifying the P1, P2 or P3 programmes.
If you modify the time schedules for the P1, P2 or P3 programmes, the
schedules will be modified for all the days of the week for which P1, P2 or P3
had been set.
-
1- If you just set the time and day, go to step 2.
- From Auto, Comfort, Eco or Frost protection mode, press for 5 seconds.
- When the cursor moves above the setting time symbol , press shortly.
-
Press The cursor moves above prog.
-
With or , select P1.
P1 will flash. Press for 5 seconds to make changes. -
The P1 start time (which by default is 06:00) will flash.
Using , you can change this time, by increments of 30 minutes.
Save by pressing . -
The P1 end time (which by default is 22:00) will flash. Using , you can change this time, by increments of 30 minutes.
Save by pressing . -
Press to exit the programming Mode and return to Auto Mode.
-
Note : without action on the keys, it will return to Auto after a few minutes.
Choices and allocation programmes
Prior information: display area
Correspondence days /numbers
Monday | 1 |
---|---|
Tuesday | 2 |
Wednesday | 3 |
Thursday | 4 |
Friday | 5 |
Saturday | 6 |
Sunday | 7 |
-
If you just set the time and day, the cursor moves automatically un- der PROG.
From Auto, Comfort, Eco or Frost protection mode, then press for 5 seconds. When the cursor positioned under the set time symbol , press again.
The days of the week are all displayed. The default program Auto (Auto Program, see page 6) appears on the display. -
Press .
The programme set for day 1 (1= Monday, 2 = Tuesday, etc.) will flash. -
3- Chose the programme you want for this day with Save by pressing
-
The programme assigned to the second day of the week (Tuesday) will flash.
Repeat the procedure described previously (in point 3) for each day of the week. -
Once you have chosen a programme for each day, confirm your selection by pressing . The days of the week will successively scroll on display with the programmes that you set for them (P1, P2, P3, CONF or ECO).
To exit the Programming mode, press twice.- Viewing the programmes that you have selected
- From Auto, Comfort, Eco or Frost protection mode, press for 5 seconds. Press twice, the programme for each day of the week (Comfort, Eco, P1, P2 or P3) will scroll on display in front of you.
- To exit the programme viewing mode, press twice
-
Manual and temporary exemption from a running programme
This function allows you to change the setting temperature temporarily until the next scheduled change in temperature or the transition to 0:00.
Example : -
The device is in Auto mode, the running programme is Eco 15,5°C.
-
By pressing , you can change temporarily the desired temperature up to 18°C for example.
Note : The cursor corresponding to the operating mode, i.e Eco mode in our example, is blinking during the duration of the temporary derogation. -
This change will be automatically cancelled at the next change of programme or transition to 0:00.
OPEN WINDOW DETECTION, ENERGY SAVINGS
- Important information about the open window detection
Important: the open window detection is sensitive to temperature variations. The device will react to the window openings in accordance with different parameters: temperature setting, rise and fall of temperature in the room, outside temperature, location of the device…
If the device is located close to a front door, the detection may be disturbed by the air caused by opening door. If this is a problem, we recommend that you disable the automatic mode open window detection (see page 15). You can, however, use the manual activation (see below).
Overview
-
Lowering temperature cycle by setting frost protection during ventilation of a room by opened window. You can access the open window detection from the Comfort, Eco and Auto modes. Two ways to enable the detector:
- Automatic activation, the lowering temperature cycle starts as soon as the device detects a temperature change.
- Manual activation, the cycle of lowering temperature starts by pressing a button.
-
Automatic activation (factory settings)
- To disable this mode, see page 15.
- The device detects a temperature fall. An opened window, a door to the outside, can cause this temperature fall.
- Note: The difference between the air from the inside and the outside must cause a significant temperature fall to be perceptible by the device. This temperature drop detection triggers the change to Frost Protection mode.
-
Manual activation
-
By pressing – for more than 5 seconds, the device will switch on Frost protection mode.
-
Frost protection digital meter
When the device performs a lower temperature cycle due to opened window, a meter appears on the display to show the cycle time. The counter is automatically reset at the next time to Frost protection by opened window (automatic or manual activation). -
Stop the Frost protection mode
- By pressing one button, you stop the Frost protection mode.
- Note : if a temperature rise is detected, the device may return to the previous mode (active mode before the open window detection).
OCCUPANCY DETECTION, ENERGY SAVINGS
-
Important information about the occupancy detection
The occupancy detector is sensitive to temperature variations and light. It is likely to be disturbed by the following items:- Hot or cold sources such as forced air vents, lights, air conditioners.
- Reflective surfaces such as mirrors.
- Animal crossing in the detection area.
- Objects moving with the wind like curtains and plants.
- Disable the occupancy detection if your device was installed near one of these.
- To disable the occupancy detection, see page 15.
Note : the detection range varies depending on the ambient temperature.
-
Overview
- The device fits your lifestyle while keeping your power consumption under control.
- With its front infrared sensor, the device smartly optimizes the management of heating : it detects movement in the room where it is installed and in case of absence, automatically performs a progressive lowering of the setting temperature resulting in: energy savings. To ensure proper operation, do not block the sensor’s field of view by any obstacle (curtains, furniture…).
Lowering the temperature during unoccupied periods
Unoccupied **periods*** | **Value of lowering setting temperature*** |
---|---|
20 minutes | Comfort -1°C |
40 minutes | Comfort -1,5°C |
1 hour | Comfort -2°C |
72 hours | Frost protection |
- Unchangeable factory settings
- Note: when presence is detected in the room, the device automatically returns to the initial mode.
Remarks:
By default, when the sensor is enabled and detects movement in the room,
the display lights up for a few seconds then switches off. To change the
backlight see page 12, backlight setting.
Operation
Divisions of the detection zone
- Detection zone, for a tempera-ture of 19°C.
- The detection zone is divided into active and inactive areas. A person that crosses the area will be detected by the infrared sensor.
INFORMATION ABOUT REMOTE CONTROL BY PILOT WIRE
Overview
- Your device can be controlled by a central control unit through a pilot wire, in which case the different operating modes will be remotely en-abled by the programmer.
- You can only control the device by pilot wire in the Auto mode. In the other modes, the orders transmitted by the pilot wire will not be exe-cuted.
- In general, a pilot wire control system makes it possible to impose exter-nally a lowering of the temperature setpoint, combined with the inter-nal programming and the occupancy detection.
- If several lowering requests appear simultaneously, priority is given to the lowest temperature setpoint, thus maximizing savings (see infor-mation on priorities for different modes on page 11).
- When a signal is sent from the pilot wire, the self learning optimization function is suspended.
- Below the different views of the display for each order sent by pilot wire:
Load shedding
- In case of over consumption, an energy power manager or a disconnector doesn’t trigger a trip of the general circuit-breaker (example: simultaneous operating of your various household appliances and others). This allows you to reduce the energy power subscribed and therefore optimize your subscription with your energy provider.
- IMHOTEP creation controllers are designed to operate with pilot wire load shedding systems.
- Orders sent by the pilot wire are executed by the device’s electronic controller which will apply the setpoint corresponding to the order sent. The “Stop” order corresponds to the load shedding. When this order is received, the device switches to “standby” and then returns to the initial operating mode.
- Important : Do not use load shedding by a power fail. Unlike pilot shedding, this type of shedding results in a series of sud-den and frequent power cuts, which cause premature wear of the device or even deterioration not covered by the manufacturer’s warranty.
- Exemption to an order coming from a pilot wire external programmer
- This feature allows you to modify temporarily the setting temperature until the next order sent by the central control unit or the transition to 00:00.
Example:
-
The device is in Auto mode. The central control unit sent an Eco order 15,5°C.
-
By pressing , you can change temporarily the desired temperature up to 18°C for example.
Note : The cursor corresponding to the operating mode, i.e Eco mode in our example, is blinking during the duration of the temporary derogation. -
This modification will be automatically cancelled at the next order sent by the central control unit or the transition to 00:00.
INFORMATION ABOUT PRIORITIES BETWEEN THE DIFFERENT MODES
Principe
- In Comfort, Eco and Frost protection modes, only orders of the occupancy sensor and those of the open window sensor will be considered.
- In Auto mode, the device can receive different orders coming from :
- 7 day and daily programming integrated (Comfort or Eco orders);
- 6-order pilot wire if connected to central control unit;
- Open window detector;
- Occupancy detector.
- In general, it is the lowest received order which prevails except when the pilot wire is connected to an energy management system, in this case the orders of the pilot wire take priority.
- If an occupancy absence of more than 72 hours is detected, switching to frost protection takes precedence unless a load shedding order is pre-sent on the pilot wire.
- Special case of self-programming where the temperature level in the room is decided according to the learning of the lifestyle and the opti-mization mode selected (Opti Comfort or Opti Eco):
- During the programmed passage in period Eco, if a presence is detected in the room, it will be taken into account and the appliance automatically switches to Comfort mode
- During the programmed passage to the Comfort mode period, the absence detection system is temporarily suspended (30 minutes).
- In case of programmed Boost, the Boost activation will take precedence over others orders received except when the standby (stop) order is pre-sent on the pilot wire, the device will switch off and the Boost will be not activated.
OPTIONAL : REMOTELY MANAGEMENT BY RF REMOTE CONTROL
Overview
- Your device can be managed by a wireless RF remote control.
- Only the RF pairing procedures to operate on the controller are described in this instructions manual.
- For installing and using the remote control, refer to its instructions manual.
RF pairing between the remote control and the blower
The remote control and the blower are not bonded together at the factory, then
proceed as follow:
-
1- From Frost protection mode, press for 5 seconds.
-
The blower is in pairing mode.
Then proceed to the remote control pairing (refer to its installing and using instruction manual). -
When both blower and remote control are linked, the symbol appears and is constantly displayed. The blower returns automatically to the frost protection mode.
Check the RF signal strength
- You can check at any time the RF transmission performance between the blower and the remote control.
- To view the RF reception level, from Frost protection mode, press + for 5 seconds. Then the level appears on the display.
1 = Low RF transmission level:
- To improve the RF transmission performance between the 2 de-vices and ensure the remotely management is optimized:
- Please ensure the RF transmission is not interrupted, move the remote control.
- Move the remote control closer to the blower.
- 10 = High RF transmission level, the location of the remote control is optimized.
RF pairing cancellation
- You can cancel at any time the RF transmission between the blower and the remote control.
- From Frost protection mode press simultaneously on – and for 5 seconds.
- The symbol disappear from the display, the remote control and the blower are not associated.
RESTORING FACTORY SETTINGS
If the PIN code protection is disabled, the user, installer and expert set- tings are re-initialized:
- From the Power setting setting, press . rest appears on the display.
- NO appears. Press to select YES.
- yes = Factory settings reset
- NO = Factory settings not reset
- for 5 seconds. The device returns to its initial configuration and goes back automatically to the Auto mode.
The following factory values will be effective:
Settings | Factory settings |
---|---|
Occupancy detection | Enabled |
Dual optimization feature | Opti comfort |
PIN code protection | Disabled |
Value of the PIN code | 0000 |
Experts settings
Power | 500W |
---|
To exit the Expert settings, press 3 times.
TECHNICAL SPECIFICATIONS
General specifications:
- Operating voltage: 230V +/-10% 50Hz.
- Maximum power of 1500W, resistive load.
- Power supply cable: 800mm, 3 Conductors.
- Radio frequency: 2,4035 Ghz/ 2,4055 Ghz / 2,4075 Ghz.
- Maximum RF power transmitted: <1mW.
- Standby consumption : <0.5W.
- Electronic PID (Proportional Integral Derivative) control, triggered by a triac.
Compliance declaration: we hereby declare under our sole responsibility that the products described in these instructions comply with the provisions of Directives and harmonized standards listed below:
- RED 2014/53/EU:
- Article 3.1a (Safety): EN60335-1/ EN60335-2-30/ EN60335-2-43/EN62333;
- Article 3.1b (EMC): ETSI EN301489-1 / ETSI EN301489-3;
- Article 3.2 (RF): ETSI EN 300440;
- ERP 2009/125/CE;
- Regulation 2015/1188/UE;
- ROHS 2011/65/EU: EN50581 and are manufactured using processes which are certified ISO 9001 V2008.
The symbol affixed on the product indicates that you must dispose of it at the end of its useful life at a special recycling point, in accordance with European Directive WEEE 2012/19/EU. If you are replacing it, you can also return it to the retailer from which you buy the replacement equipment. Thus, it is not ordinary household waste. Recycling products enables us to protect the environment and to use less natural resources.