Specifications:

  • Product: AAL1 Series – LED Area Light
  • Mouting Options: Trunnion, Slip Fitter, Adjustable Mounting Arm, Fixed Arm
  • Additional Accessory: AAL1-TR (Trunnion), AAL1-SF (Slip Fitter), AAL1-MA (Adjustable Mounting Arm), AAL1-FM (Fixed\ Arm)

Product Usage Instructions

Trunnion Mount Installation:

  1. Pass the fixture cord through the trunnion.
  2. Attach trunnion mount to fixture with provided hardware and adjust as required.

Slip Fitter Mount Installation:

  1. Separate the slip fitter into two pieces.
  2. Feed the fixture cord through the slip fitter that will mount to the fixture.
  3. Attach the slip fitter half from Step 2 to the fixture with provided hardware and pass the cord through the other slip fitter half.
  4. Screw the slip fitter together and adjust angle as required.

Mounting Arm Mount Installation:

  1. Remove and retain the access plate and separate the mounting arm into two pieces.
  2. Feed the fixture cord through the half of the mounting arm that will mount to the fixture.
  3. Attach the mounting arm half from Step 2 to the fixture with provided hardware and pass the cord through the other mounting arm half.
  4. Adjust the mounting arm as required.
  5. Screw the mounting arm together, reattach the access plate ensuringgasket placement.

Fixed Arm Mount Installation:

  1. Remove and retain screws to separate the fixed arm into two pieces.
  2. Feed the fixture cord through the half of fixed arm that will mount to the fixture.
  3. Attach the fixed arm half from Step 2 to the fixture with provided hardware, slide the two fixed arm pieces together and secure with retained screws from Step 1.

Mount to Structure Installation:

ALWAYS TURN OFF THE POWER SUPPLY FROM MAIN CIRCUIT BREAKER FIRST!

Frequently Asked Questions

  • Q: Can I install this product without professional help?
    • A: It is recommended to consider a qualified licensed electrician for installation to ensure safety and proper setup.
  • Q: Where can I find additional information not covered in the manual?
    • A: For additional information not covered in this document, please contact a local representative for assistance.

OVERVIEW

WHAT’S IN THE BOX

  • AAL1 fixture
  • Pre-installed 3.3ft cord

WHAT YOU’LL NEED

  • Wiring supplies as per national and local electrical codes
  • Hardware and tools required to mount to structure (field provided)
  • Hex bit drivers to attach mounts

ONE OF THE FOLLOWING REQUIRED TO MOUNT

  • Trunnion: AAL1-TR
  • Slip Fitter: AAL1-SF
  • Adjustable Mounting Arm: AAL1-MA
  • Fixed Arm: AAL1-FM

IMPORTANT

Before installing fixture, read all instructions and retain for future reference. The important instructions and safeguards that appear in this document are not inclusive of all possible conditions and situations that may occur. It must be understood that common sense, caution, and care are factors that cannot be built into a product. These factors must be supplied by those that care and operate the fixture. Consider a qualified licensed electrician for installation. For additional information required not covered in this document please contact a local representative.

WARNING AND SAFETY

  • Risk of electric shock!
  • To avoid damage, do not install on rainy days!
  • Ensure power is OFF at the electrical panel before starting installation or maintenance
  • Verify site supply voltage matches the luminaire product label
  • Ensure wiring connections are not exposed during operation
  • Modifications to the product will void warranty
  • Ambient temperature range under normal operation not to exceed -40°F to 113°F (-40°C to 45°C)
  • Minimum supply 167°F (75°C) supply conductors
  • Wiring to fixture must be in accordance with the National Electrical Code and all applicable local electrical and safety regulations

WIRING SCHEMATIC

WIRING SCHEMATIC FOR SINGLE CCT, SINGLE WATT MODELS

MOUNTING ACCESSORIES

MOUNTING ACCESSORIES TO FIXTURE INSTALLATION (ORDERED SEPARATELY)

ALWAYS TURN OFF THE POWER SUPPLY FROM MAIN CIRCUIT BREAKER FIRST!

  • There are 4 optional brackets for this fixture, see diagram below.

TRUNNION MOUNT

ALWAYS TURN OFF THE POWER SUPPLY FROM MAIN CIRCUIT BREAKER FIRST! OPTIONAL ACCESSORY: AAL1-TR

  1. Pass the fixture cord through the trunnion.
  2. Attach trunnion mount to fixture with provided hardware and adjust as required.

SLIP FITTER MOUNT

ALWAYS TURN OFF THE POWER SUPPLY FROM THE MAIN CIRCUIT BREAKER FIRST!

  • OPTIONAL ACCESSORY: AAL1-SF
  1. Separate the slip fitter into two pieces. (Figure 1)
  2. Feed the fixture cord through the slip fitter that will mount to the fixture. (Figure 1)
  3. Attach the slip fitter half from Step 2 to the fixture with provided hardware and pass the cord through the other slip fitter half. (Figure 2)
  4. Screw the slip fitter together and adjust angle as required. (Figure 2)

MOUNTING ARM MOUNT

ALWAYS TURN OFF THE POWER SUPPLY FROM THE MAIN CIRCUIT BREAKER FIRST! OPTIONAL ACCESSORY: AAL1-MA

  1. Remove and retain the access plate and separate the mounting arm into two pieces. (Figure 1)
  2. Feed the fixture cord through the half of the mounting arm that will mount to the fixture. (Figure 1)
  3. Attach the mounting arm half from Step 2 to the fixture with the provided hardware and pass the cord through the other mounting arm half. (Figure 2)
  4. Adjust the mounting arm as required. (Figure 2)
  5. Screw the mounting arm together, reattach access plate ensuring gasket placement. (Figure 2)

FIXED ARM MOUNT

ALWAYS TURN OFF THE POWER SUPPLY FROM MAIN CIRCUIT BREAKER FIRST!

OPTIONAL ACCESSORY: AAL1-FM

  1. Remove and retain screws to separate the fixed arm into two pieces. (Figure 1)
  2. Feed the fixture cord through the half of fixed arm that will mount to the fixture. (Figure 1)
  3. Attach the fixed arm half from Step 2 to the fixture with provided hardware, slide the two fixed arm pieces together and secure with retained screws from Step 1. (Figure 2)
  4. Pass the cord through the other fixed arm half, and close the access plate. (Figure 2)

MOUNT TO STRUCTURE INSTALLATION

ALWAYS TURN OFF THE POWER SUPPLY FROM MAIN CIRCUIT BREAKER FIRST! TRUNNION MOUNT

  1. Use trunnion or indicated hole spacing to mark spacing required on surface. (Figure 1)
  2. Drill holes and attach trunnion mount to surface with hardware as required. (Figure 1)
    Note: surface mounting hardware field provided.
    Note: loosen sides of trunnion to adjust angle up to go 90° from vertical, tighten once angle is set. (Figure 2)

SLIP FITTER

  1. With slip fitter attached to fixture, refer to attached wiring diagram to complete connections. (Figure 1)
  2. Loosen slip fitter mounting screws and mount onto a 2″ to 2-3/8″ tenon. Tighten slip fitter mounting hardware to secure Note: loosen slip fitter bolt to adjust angle up to 90° from vertical, tighten once angle is set. (Figure 2)

MOUNT TO STRUCTURE INSTALLATION

ALWAYS TURN OFF THE POWER SUPPLY FROM MAIN CIRCUIT BREAKER FIRST! ADJUSTABLE MOUNTING ARM MOUNT

  1. Remove and retain install plate, hardware, flat and curved gaskets. As necessary, remove and retain the access cover, screws and gasket for wiring or mounting. (Figure 1)
  2. Use install plate or indicated hole spacing to mark holes as required on pole. Note: top hole must be used, plus one of four small holes below (large hole is for wiring). (Figure 1)
  3. Drill screw holes and wiring hole through pole as required. (Figure 1)
  4. To mount; line-up installs plate with drilled holes inside of pole. For a square pole, align mounting arm outside of pole keeping both retained gaskets between pole and mounting arm and using provided hardware fasten install plate and mounting arm together. For a round pole, the curved gasket is not required, but flat gasket to remain when fastening.
    Note: curve of the mounting arm can mount onto 4″ and 5″ round poles. (Figure
  1. Refer to attached wiring diagram to complete the connections. (Figure 1)
  2. Adjust the mounting arm as required (up to 30° above horizontal). (Figure 2 & 3)

FIXED ARM MOUNT

  1. Remove and retain install plate, hardware, flat and curved gaskets. (Figure 1)

  2. Use install plate or indicated hole spacing to mark holes as required on pole.
    Note: top hole must be used, plus one of four small holes below (large hole is for wiring). (Figure 1)

  3. Drill screw holes and wiring hole through pole as required. (Figure 1)

  4. To mount; line-up installs plate with drilled holes inside of pole. For a square pole, align fixed arm outside of pole keeping both retained gaskets between pole and fixed arm and using provided hardware fasten install plate and fixed arm together. For a round pole, the curved gasket is not required, but flat gasket to remain when fastening.
    Note: the curve of fixed arm can mount onto 4″ and 5″ round poles. (Figure 2)

  5. Refer to attached wiring diagram to complete the connections. (Figure 3)

  6. Close access plate. (Figure 4)

CONTROLS AND OPERATION

ALWAYS TURN OFF THE POWER SUPPLY FROM MAIN CIRCUIT BREAKER FIRST!

PHOTOCELL

  1. AAL1 does not come with the NEMA photocell socket pre-installed. NEMA photocell socket must be factory installed. Refer to spec sheet for factory installed code.
  2. Twist-lock to install photocell or shorting cap. If a NEMA photocell socket is installed, a photocell or shorting cap must be installed for the fixture to operate.

CONTROLS & SENSORS

Refer to AAL1 spec sheet for compatible sensors, controls and commissioning tools

  1. Remove ½” knockout plug on front face of the fixture.
  2. Screw the sensor with the silicone gasket in place until tight.

POWER SELECT AND CCT SELECT

ALWAYS TURN OFF THE POWER SUPPLY FROM THE MAIN CIRCUIT BREAKER FIRST!

PowerSet

  1. Unscrew the 3/4″ plug.
  2. Adjust the switch to get the desired color temperature according to label on the fixture.
  3. Install and tighten the 3/4″ plug.

FieldCCeT

  1. Unscrew the 3/4″ plug.
  2. Adjust the switch to get the desired wattage according to the label on the fixture.
  3. Install and tighten the 3/4″ plug.

GLARE SHIELDS INSTALLATION

  • Select the appropriate glare shield kit for your fixture.
  • All four glare shields can be installed either together or mixed and matched for installation.

Install all four glare shields onto a single fixture

  1. Remove all silicone screw plugs.
  2. Align the back shield with the fixture mounting hole.
  3. Align the front shield with the fixture mounting hole.
  4.  Align the side shield with the fixture mounting hole.
  5. Align another side shield with the fixture mounting hole.
  6. Install the screw to secure the shield, completing the installation.

Install side shields only onto a single fixture

  1. Align the side shield with the fixture mounting hole.
  2. Align another side shield with the fixture mounting hole.
  3. Install the screw to secure the shield, completing the installation.

©2024 EiKO Global, LLC. World Headquarters: 18000 W. 105th Street, 3rd Floor, Olathe, KS 66061 1.800.852.2217 Head Office, Canada: 7900 Goreway Drive, Unit 8, Brampton, ON L6T 5W6 1.888.741.2673