EiKO VRT1-130-C5-750-U-D-T3-BZ Light Bulbs and Fixtures Instruction Manual
- June 9, 2024
- EiKO
Table of Contents
VRT1-130-C5-750-U-D-T3-BZ Light Bulbs and Fixtures
Instruction Manual
INSTALLATION INSTRUCTIONS
VERT – Site Light
SAFETY PRECAUTIONS:
- MIN 90° C SUPPLY CONDUCTORS
- SUITABLE FOR OPERATION IN AMBIENT NOT EXCEEDING 50° C
- DISCONNECT POWER BEFORE SERVICING
- CAUTION – RISK OF FIRE
- CAUTION – RISK OF SHOCK
WIRING:
ALWAYS TURN OFF THE POWER SUPPLY FROM MAIN CIRCUIT BREAKER FIRST!
- THIS PRODUCT HAS DIMMING FUNCTION.
- 3 DIMMING FUNCTIONS ARE AVAILABLE IN THE VERT:
- CONSTANT CURRENT CAN BE ACHIEVED BY 1-10VDC DIMMING.
- PWM SIGNAL DIMMING.
- VARIATION OF RESISTANCE UNIT DIMMING(PLEASE CHOOSE THE APPROPRIATE DIMMING WAY ACCORDING TO YOUR NEEDS. YOU CAN ALSO CHOOSE NOT TO USE THIS FUNCTION).
- CHOOSE THE WIRE CONNECTION WAYS, DIMMING WAYS AND INSTALLATION WAYS ACCORDING TO YOUR NEEDS AND THE LED FIXTURE PURCHASED.
OPTIONAL BRACKETS INSTALLATION:
ALWAYS TURN OFF THE POWER SUPPLY FROM MAIN CIRCUIT BREAKER FIRST!
- THERE ARE 4 OPTIONAL BRACKETS FOR THIS FIXTURE. SEE DIAGRAM BELOW.
SLIP FITTER MOUNTING:
ALWAYS TURN OFF THE POWER SUPPLY FROM MAIN CIRCUIT BREAKER FIRST!
- REMOVE THE BRACKET MOUNTING SCREWS ON THE FIXTURE AND RUN THE WIRES THROUGH THE BRACKET. (FIGURE 1)
- INSTALL THE BRACKET ON THE FIXTURE. (FIGURE 2)
SLIP FITTER MOUNTING WIRING:
ALWAYS TURN OFF THE POWER SUPPLY FROM MAIN CIRCUIT BREAKER FIRST!
- LOOSEN THE FOUR BOLTS ON AM BRACKET, CONNECT THE WIRES CORRECTLY, AND PULL THE WIRES INTO THE POLES. (FIGURE 3)
- PLACE THE BRACKET INTO THE POLE AND LOCK THE FOUR BOLTS. (FIGURE 4)
• NOTICE: ADJUSTABLE ANGLE IS 0-90°. (FIGURE 3)
• PIPE DIAMETER RANGE IS 1½” to 2⅜”
DIRECT MOUNTING:
ALWAYS TURN OFF THE POWER SUPPLY FROM MAIN CIRCUIT BREAKER FIRST!
- REMOVE THE BRACKET MOUNTING SCREWS ON THE FIXTURE, OPEN THE SIDE LID OF BRACKET AND RUN THE WIRES THROUGH THE BRACKET. (FIGURE 5)
- INSTALL THE BRACKET ON THE FIXTURE, THEN COVER THE SIDE LID AND TIGHTEN IT. (FIGURE 6)
DIRECT MOUNTING WIRING:
ALWAYS TURN OFF THE POWER SUPPLY FROM MAIN CIRCUIT BREAKER FIRST!
-
FIX DM BRACKET TO SQUARE POLE WITH BOLT, OPEN THE SIDE LID OF DM BRACKET, PULL THE WIRE INTO JUNCTION BOX, AND CONNECT THE WIRE CORRECTLY. (FIGURE 7)
-
PUT THE CONNECTED WIRE INTO THE JUNCTION BOX, THEN COVER THE JUNCTION BOX. (FIGURE 8)
• NOTICE: ADJUSTABLE ANGLE IS 0-35°(FIGURE 7). -
SAME AS ROUND POLE INSTALLATION, REMOVE THE SILICON PLATE WHEN INSTALL THE FIXTURE IN ROUND POLE. (FIGURE 9)
YOKE MOUNTING:
ALWAYS TURN OFF THE POWER SUPPLY FROM MAIN CIRCUIT BREAKER FIRST!
- REMOVE THE BRACKET MOUNTING SCREWS ON THE FIXTURE AND RUN THE WIRES THROUGH THE BRACKET. (FIGURE 10)
- INSTALL THE BRACKET ON THE FIXTURE. (FIGURE 11)
YOKE MOUNTING WIRING:
ALWAYS TURN OFF THE POWER SUPPLY FROM MAIN CIRCUIT BREAKER FIRST!
- DRILL HOLES ON THE WALL AS SHOWN. (FIGURE 12)
- KNOCK THE EXPANSION BOLTS INTO THE WALL. (FIGURE 13)
- CONNECT THE FIXTURE TO THE BRACKET AND TIGHTEN THE SCREWS; CONNECT THE WIRES PROPERLY AND PUT THEM INTO JUNCTION BOX. (FIGURE 14)
• NOTICE: ADJUSTABLE ANGLE IS 0-90° (FIGURE 14)
Z10 MICROWAVE SENSOR INSTALLATION (OPTIONAL):
ALWAYS TURN OFF THE POWER SUPPLY FROM MAIN CIRCUIT BREAKER FIRST!
• TO INSTALL THE Z10 MICROWAVE SENSOR TURN AND LOOSEN THE PLASTIC COVER, THEN
REMOVE THE PLASTIC COVER FROM THE SOCKET AND PUT THE Z10 MICROWAVE SENSOR ON
THE SOCKET AND TIGHTEN IT. IF NOT INSTALLED EMOVE THE Z10 MICROWAVE SENSOR,
AND TIGHTEN THE PLASTIC COVER ON THE SOCKET. (FIGURE 23)