Specifications

RVL80

performance at 4″ ducting

Static Pressure
(in kg)| Arrow
(cfm)| Sound
(sones)| Energy
(watts)| Duct
Size
---|---|---|---|---
0.1| 80| 0.8| 20| 4 in
0.25| 63|  | 19.5| 4 in
Voltage| 120 V
---|---
Frequency| 60 Hz
LED Watts| 13 W
LED Brightness| 900, 1000, or 1000 Lumens
LED Color Temp| 2700, 4000, or 5000 Kelvin
Fan Weight| 5.25 Lbs ( 2.4 Kg )
Shield Size| 11 x 11 in ( 27.9 x 27.9 cm )
Housing Length| 8 3/8 in ( 21.3 cm )
Housing Width
| 7 7/8 in ( 20 cm )
Housing Depth*| 5 1/8 in ( 13 cm )

  • This may require modification of your current opening. Some hand tools required. Power tools may also be necessary.

What’s Inside The Box

ReVent RVL80 Bathroom Exhaust Fan with LED Light Fig

Safety Information

  1. WARNING – TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:
    a) Installation work and electrical wiring must be done by a qualified person(s) in accordance with all applicable codes and standards, including fire-rated construction.
    b) Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel-burning equipment to prevent back drafting. Follow the heating equipment manufacturer’s guidelines and safety standards, such as those published by the National Fire Protection Association (NFPA), the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE), and the local code authorities.
    c) When cutting or drilling into a wall or ceiling, do not damage electrical wiring and other hidden utilities.
    d) Ducted fans must always be vented to the outdoors.
    e) If this unit is to be installed over a tub or shower, it must be marked as appropriate for the application and be connected to a GFCI (Ground Fault Circuit Interrupter) – protected branch circuit.

  2. Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer.

  3. Before servicing or cleaning the unit, switch the power off at the service panel and lock the service disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.

  4. This ventilation fan is approved for use over a bathtub or shower when installed in a GFCI-protected circuit. Do not use unapproved fans over a bathtub or shower that are not approved for that application.

  5. Install ductwork in a straight line with minimal bends.

  6. Use 120 V, 60 Hz for the electrical supply and properly ground the unit. Follow all local safety and electrical codes.

  7. Do not use this fan with any solid-state control device; such as a dimmer switch. Solid-state controls may cause harmonic distortion, which can cause a motor humming noise, as well as increase the risk of fire or electric shock.

  8. To reduce the risk of fire or electric shock, do not block the air entry shield.

  9. Mount with the lowest moving parts at least 8.2 ft (2.5 m) above floor or grade level.

  10. Never place a switch where it can be reached from a tub or shower.

  11. Type IC for use in direct contact with thermal insulation not to exceed R-50.

  12. Not for use in cooking areas. (See PAGE 5 for details)

  13. This product must properly connect to the grounding conductor of the supply circuit.

Follow the heating equipment manufacturer’s guidelines and safety standards, such as those published by the National Fire Protection Association (NFPA), the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE), and the local code authorities.
WARNING: Not suitable for use as a range hood.
CAUTION: For General Ventilating Use Only – Do Not Use To Exhaust Hazardous Or Explosive Materials And Vapors.
CAUTION: Do not install in locations where the temperature will exceed 104°F (40°C).
IMPORTANT: Exercise care to not damage existing wiring when cutting or drilling into walls or ceilings.
NOTE: Make sure duct work size is a minimum of the discharge. Do not reduce. Reducing the duct size can increase fan noise.
IMPORTANT: You may want to consult with a qualified licensed electrician regarding the wiring of your ventilation fan.
WARNING: To reduce the risk of electric shock, please disconnect the electrical supply circuit before servicing.
CAUTION: This product must be properly grounded.
Go to reventfans.com to obtain a copy of this manual.

Planning Your Installation

ReVent RVL80 Bathroom Exhaust Fan with LED Light Fig1

ReVent RVL80 Bathroom Exhaust Fan with LED Light Fig2

When installing the ventilation fan in a new construction site, install the main body of the FAN and ductwork during the rough-in construction of the building. The SHIELD should be installed after the finished ceiling is in place.
When installing in existing construction, use the provided cutout TEMPLATE for the ceiling. The SHIELD edge should overlap the finished ceiling.
Not for use in the cooking area – see the diagram below. Do not install a ventilation fan in areas where the ductwork will require configuration as shown. NOTE: If installing in existing construction, you may need to have access to space above and below the installation location.
There are multiple installation configurations possible for this ventilation fan. Not all configurations are shown. If your installation requires a variation other than those shown, consult with a licensed contractor to determine the best installation for your project. If you are replacing an existing fan, ensure that the new FAN will adequately cover the existing opening.

Connecting the Duct

  • Install a circular duct to the outlet and secure it with duct tape or clamps.
  • Install the duct to the outlet with a gradient of 1°~2° to the outside as shown.
  • The ducting from this FAN to the outside of the building has a strong effect on
  • the airflow, noise, and energy use of the fan. Use the shortest, straightest duct
  • routing possible for the best performance, and avoid installing the FAN with smaller
  • ducts than recommended. Insulation around the ducts can reduce energy loss
  • and inhibit mold growth. Fans installed with existing ducts may not achieve their
  • rated airflow.
  • 4 in (10.16 cm) round is recommended for best performance.
  • Ensure duct joints and exterior penetrations are sealed with caulk or other
  • similar material to create an air-tight path, minimize building heat loss and
  • gain, and to reduce the potential for condensation.
  • Place/wrap insulation around the duct and/or FAN in order to minimize possible
  • condensation buildup within the duct, building heat loss and gain.

ReVent RVL80 Bathroom Exhaust Fan with LED Light Fig3

Removing Your Old Fan

  1. Disconnect the electrical power supply and lock out the service panel for the existing fan.
  2. Remove the grille from the existing fan. Pull the grille down to expose its two springs. Squeeze each spring together and pull down again to release the springs from the motor plate slots.ReVent RVL80 Bathroom Exhaust Fan with LED Light Old Fan
  3. Your existing fan may be attached in several ways. Look for attachment screws in the ceiling and remove them. Your fan may also be attached on the attic side, which will require you to access it from the attic. Locate attic attachment screws and remove them. Fan removal can be the most difficult step, please watch this video: reventfans.com/how-to-remove-an-old-bath-fanReVent RVL80 Bathroom Exhaust Fan with LED Light Locate
  4. Remove the old fan. This may require cutting and pulling. Wear gloves and eye protection.ReVent RVL80 Bathroom Exhaust Fan with LED Light gloves

SheetLock® Easy RoomsideInstallation

Watch the video:reventfans.com
WARNING: Disconnect all AC Power Breakers or Fuses before attempting to cut into your ceiling.

  1. Place the provided sheetrock cutout TEMPLATE on the 1ceiling where you wish the FAN to be (DAMPER and electrical positions shown on the TEMPLATE). We suggest using painter’s masking tape to hold the template in place while cutting. If there is a pre-existing fan opening, use aligning windows to find it’s edges. Either cut through the provided guide slots in the TEMPLATE or mark your cut lines with a pencil and remove the TEMPLATE. Use a sheetrock jab saw to cut your fan opening in the ceiling.ReVent RVL80 Bathroom Exhaust Fan with LED Light Roomside

  2. Use a flathead screwdriver to raise the DAMPER away from the notch in the FAN body, then slide the DAMPER up halfway until the notch in the side of the DAMPER aligns with the upper set of guides. Remove the DAMPER from the FAN.ReVent RVL80 Bathroom Exhaust Fan with LED Light DAMPER

  3. Attach DAMPER to ducting. Tape DAMPER to ducting with duct tape. Set the connected DAMPER and ducting in the ceiling opening, then set the FAN in the ceiling opening as well.ReVent RVL80 Bathroom Exhaust Fan with LED Light ceiling opening

  4. Attach conduit with wiring to FAN.ReVent RVL80 Bathroom Exhaust Fan with LED Light FAN

  5. Reattach the DAMPER to the FAN inside the ceiling, the damper should click into place securely.ReVent RVL80 Bathroom Exhaust Fan with LED Light damper should

  6. Select a set of holding tabs, depending on the thickness of your sheetrock.ReVent RVL80 Bathroom Exhaust Fan with LED Light sheetrock

  7. Bend the holding tabs you selected outward.ReVent RVL80 Bathroom Exhaust Fan with LED Light outward

  8. Set FAN into place in the opening using holding tabs, now the tabs hold the fan in position in the ceiling opening.ReVent RVL80 Bathroom Exhaust Fan with LED Light holding WARNING: Disconnect the AC power before any work is done to any part of the circuit ReVent® is connected to. If you do not understand this warning, seek the services of a qualified licensed electrician.
    WARNING: Copper to copper only. Do not use aluminum wire.
    WARNING: Follow all local electrical and safety codes, and NEC (National Electrical Codes).
    CAUTION: If your house wires do not match these colors, determine what each house wire represents before connecting. You may need to consult a qualified licensed electrician to determine this safely.

  9. Disconnect the FAN motor from the electrical enclosure. Remove the electrical cover set screw and slide open the electrical enclosure.ReVent RVL80 Bathroom Exhaust Fan with LED Light FAN motor

  10. Connect wiring using the provided WIRE NUTS.
    Wire connection for fan and light on separate switches:ReVent RVL80 Bathroom
Exhaust Fan with LED Light WIRE NUTS Wire connection for fan and light on one switch:ReVent RVL80
Bathroom Exhaust Fan with LED Light light on SWITCHES NOT INCLUDED, USE EXISTING OR MUST BE PURCHASED SEPARATELY
    Always follow all safety instructions included with the switch you purchase. Do not exceed maximum electrical ratings.ReVent RVL80 Bathroom Exhaust Fan
with LED Light wiring to FAN1

  11. Once connected, reattach the electrical enclosure.ReVent RVL80 Bathroom Exhaust Fan with LED Light wiring to FAN2

  12. Press and bend the final securing tabs flat against the ceiling to lock the FAN in place.ReVent RVL80 Bathroom Exhaust Fan with LED Light lock the FAN

  13. Align the TRIM RING notch to the vent (DAMPER) position. Attach TRIM RING to FAN. TRIM RING attaches to the FAN body and clicks into place when secure.ReVent RVL80 Bathroom Exhaust Fan with LED Light wiring to FAN3

  14. Select desired LED color temperature by sliding the selector switch on the back of the SHIELD.ReVent RVL80 Bathroom Exhaust Fan with LED Light wiring to FAN5

  15. Connect the LED wire to the LED plug. Attach the SHIELD by squeezing the mounting springs together and inserting the springs into the spring guides in the FAN.ReVent RVL80 Bathroom Exhaust Fan with LED Light wiring to FAN6

Installation For New Construction Framing
NOTE: Even with new construction, you can use the SheetLock® installation method; however, ReVent® can still be installed using a method home builders would be more familiar with, as outlined in this section.
WARNING: Disconnect all AC Power Breakers or Fuses before attempting to cut into your ceiling.

  1. Select a set of holding tabs, depending on the thickness of your sheetrock.ReVent RVL80 Bathroom Exhaust Fan with LED Light sheetrock

  2. Bend the holding tabs you selected outward.ReVent RVL80 Bathroom Exhaust Fan with LED Light selected outward1

  3. Attach FAN to ceiling joists with BRACKETS using ROUNDHEAD WOOD SCREWS, then install the sheetrock for your ceiling.ReVent RVL80 Bathroom Exhaust Fan with LED Light sheetrock 1

  4. Attach conduit with wiring to FAN.ReVent RVL80 Bathroom Exhaust Fan with LED Light wiring to FAN

  5. Attach DAMPER to ducting.ReVent RVL80 Bathroom Exhaust Fan with LED Light DAMPER to ducting WARNING: Disconnect the AC power before any work is done to any part of the circuit ReVent is connected. If you do not understand this warning, seek the services of a qualified licensed electrician.
    WARNING: Copper to copper only. Do not use aluminum wire.
    WARNING: Follow all local electrical and safety codes, and NEC (National Electrical Codes).
    CAUTION: If your house wires do not match these colors, determine what each house wire represents before connecting. You may need to consult a qualified licensed electrician to determine this safely.

  6. Disconnect the FAN motor from the electrical enclosure. Remove the electrical cover set screw and slide open the electrical enclosure.ReVent RVL80 Bathroom Exhaust Fan with LED Light electrical enclosure

  7. Connect wiring using the provided WIRE NUTS.
    Wire connection for fan and light on separate switches:ReVent RVL80 Bathroom
Exhaust Fan with LED Light light Wire connection for fan and light on one switch:ReVent RVL80
Bathroom Exhaust Fan with LED Light light on1 SWITCHES NOT INCLUDED, MUST BE PURCHASED SEPARATELY
    Always follow all safety instructions included with the switch you purchase. Do not exceed maximum electrical ratings.ReVent RVL80 Bathroom Exhaust Fan
with LED Light selected outward1

  8. Once connected, reattach the electrical enclosure.ReVent RVL80 Bathroom Exhaust Fan with LED Light selected outward2

  9. Press and bend the final securing tabs flat against the ceiling to lock the FAN in place.ReVent RVL80 Bathroom Exhaust Fan with LED Light final securing

  10. Align the TRIM RING notch to the vent (DAMPER) position. Attach TRIM RING to FAN. TRIM RING attaches to the FAN body and clicks into place when secure.ReVent RVL80 Bathroom Exhaust Fan with LED Light DAMPER1

  11. Select desired LED color temperature by sliding the selector switch on the back of the SHIELD.ReVent RVL80 Bathroom Exhaust Fan with LED Light SHIELD

  12. Connect the LED wire to the LED plug. Attach the SHIELD by squeezing the mounting springs together and inserting the springs into the spring guides in the FAN.ReVent RVL80 Bathroom Exhaust Fan with LED Light LED plug

Care and Cleaning

WARNING: To reduce the risk of electric shock, fire, or injury to persons, disconnect or turn off the breaker and lock the power supply at the panel to prevent the power from being turned on before servicing or cleaning the unit.

  1. Remove the SHIELD by squeezing the springs and pulling them down.
  2. Remove dust and dirt from the FAN with a vacuum cleaner.
  3. Dampen a cloth with dish detergent. Wipe the FAN and dry it with a cloth.
  4. Replace the SHIELD.

Frequently Asked Questions

Q: How do I clean my FAN?

A: It’s important to clean the SHIELD cover from time to time. Dust particles can build up on the SHIELD. See PAGE 18 for care and cleaning instructions.

Q: What is CFM?

A: CFM is a measurement of air movement (cubic feet per minute). The higher the CFM, the more air movement.

Q: What is a sone?

A: Sone is the rating used to describe the sound level. The lower the sone the quieter the fan. A sone is not a decibel. Fans around 1 sone or less are considered quiet while fans around 2 sones or more are considered loud.

Q: Can I install my bathroom ventilation FAN directly over a bathtub or shower?

A: Yes, but your FAN must be rated for over a shower/bath installation (all ReVent models are) and must be on a GFCI-protected circuit. Consult a qualified licensed electrician about ground fault-protected safety circuits.

Q: Do I have to vent my FAN to the outside?

A: Yes. All spot ventilation fans must be vented to the outside. Follow your local code and consult it for advice. See PAGE 5 for national venting installation suggestions and guidelines.

Q: Why do the windows and mirrors fog even when the FAN is running?

A: If windows and mirrors are very cold, condensation can still form on those surfaces. If the bathroom is sealed tightly, replacement air may not be entering the room fast enough to displace moist air. You need a gap under the bathroom entrance door to allow air to enter the bathroom. If your home uses 3-inch diameter ducting, upgrading the duct pipe to a 4-inch diameter can greatly increase the airflow. The vent pipe length should be 10 feet or less with minimal bends (See PAGE 5). Ensure that the vent pipe is not blocked.

Q: My FAN is operating, but the air is moving slower than normal.

A: Check for obstructions in the ductwork. A common problem is debris blocking the roof cap or outside wall vent. Older homes may have 3-inch diameter ducting and changing the duct pipe to a 4-inch diameter can greatly increase airflow.

Q: Why is there water dripping from my FAN?

A: Dripping water is typically condensation from a cold vent pipe. Insulating the ductwork and FAN housing can help solve condensation problems. Running the FAN longer will ensure moisture is completely removed from the duct. Another possibility is rain entering the vent pipe through the roof vent opening.

Q: I have installed my FAN and it is not working, what do I do?

A: Make sure the black and white plug-in connector on the FAN is clicked into place. Check all electrical connections like wire nuts and quick connects. Make sure the circuit breaker is turned ON after completing all the electrical work. If you have any concerns consult a licensed electrician.

Q: How do I change the color temperature of the LED light?

A: The color temperature can be adjusted by sliding the selector switch on the back of the SHIELD (See PAGE 12).

Q: I only have 1 switch. Can I wire the LED light and FAN together?

A: Yes. See PAGES 9-11 for instructions on how to do this. However, if you are using a dimmer, you cannot connect the FAN and LED light together on the dimmer switch. The FAN wires cannot be connected to a dimmer switch.

Q: I still have additional questions.

A: Contact us at info@reventfans.com or call our service department at 877-543-8698. We are happy to assist you with any additional questions.

3-Year Limited Warranty

GTR Technologies Inc. (GTR) warrants to the original purchaser of its products that such products will be free from defects in materials and workmanship for a period of three years from the date of the original purchase. There are no other warranties, express or implied, including but not limited to, implied warranties of merchantability or fitness for a particular purpose.
During this three-year period, GTR will, at its option, repair or replace, without charge, any product or part which is found to be defective under normal use and service. This warranty does not extend to lighting such as LEDs, Fluorescent, Incandescent, tubes, starters or bulbs.
This warranty does not cover:
(a) normal maintenance and service or
(b) any maintenance or repair, faulty installation or installation contrary to recommended installation instructions.
The duration of any implied warranty is limited to the three-year period as specified for the express warranty. Some areas do not allow limitations on how long an implied warranty lasts, so the above limitation may not apply to you. GTR’s obligation to repair or replace, at GTR’s option, shall be the purchaser’s sole and exclusive remedy under this warranty. GTR shall not be liable for incidental, consequential, or special damages arising out of or in connection with product use or performance. Some areas do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation may not apply to you.
This warranty gives you specific legal rights, and you may also have other rights, which vary from area to area.
This warranty supersedes all prior warranties.
This warranty is only valid inside the boundaries of the USA and Canada.
To qualify for warranty service, you must:
(a) notify GTR via phone at 1-877-543-8698 (English) or 1-800-615-5439 (French) or via email at info@reventfans.com,
(b) give the model number identification, and
(c) describe the nature or any defect in the product or part.
At the time of requesting warranty service, you must provide evidence of the original purchase receipt.
GTR Technologies Inc.
www.reventfans.com

Need Help?
Watch the installation video at:
reventfans.com
Questions? Call
1-877-543-8698 (English) or
1-800-615-5439 (French)
info@reventfans.com
ReVent®is a product of GTR Technologies Inc. All rights reserved.
The USA and international patents are pending.
PART# RVP-155-WH-01 092321

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals