Danfoss ERC 213 Electronic Refrigeration Control Installation Guide
- July 24, 2024
- Danfoss
Table of Contents
- Danfoss ERC 213 Electronic Refrigeration Control
- Product Information
- Product Usage Instructions
- Technical Highlights
- User Interface
- Dimensions (mm) and mounting
- Electrical connections
- Quick configuration at power-up
- Quick Configuration via “cFg” Menu
- Technical specifications
- Parameter List
- FAQ
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Danfoss ERC 213 Electronic Refrigeration Control
Product Information
Specifications
- Model : ERC 213
- Type : Electronic refrigeration control
- Relays : 3
- Designed for : Commercial refrigeration applications
User Interface
The ERC 213 features a user-friendly interface with key functions that
include scrolling, main switch ON/OFF, factory reset, defrost control, back
function, pull-down start/stop, set point change, and menu access.
Display Icons
- Night mode (Energy saving)
- Fan running
- Compressor running (Flashes in pull-down mode)
- Active alarm
- Defrost
Dimensions and Mounting
- Dimensions : 83mm x 61.2mm x 66mm
- Mounting : Rear mounting with lock clips
- Electrical connections : Refer to the electrical connections diagram for details on wiring.
Product Usage Instructions
Installation
- Mount the ERC 213 using the provided drilling template and secure it with clips.
- Ensure correct electrical connections based on the provided diagram.
- Connect power connectors according to the specified phase requirements.
Initial Configuration
Upon power up, perform quick configuration within 30 seconds by following the
specified steps.
Usage
- To scroll up or down, perform short presses of less than 1 second.
- To turn the main switch ON/OFF, press and hold for approximately 3 seconds.
- To access the factory reset function, press and hold at power up.
The ERC 213 is a smart multipurpose refrigeration controller with temperature and defrost management, available with 3 relays. The controller has been designed to fulfill today’s requirements of commercial refrigeration applications
Technical Highlights
- Ease of use : Four buttons, easy menu structure, and preinstalled application solutions ensure superior usability
- Simple installation : High performance 16 A relay enables direct connection of heavy loads, such as 2 hp compressors, without use of intermediate relays. A wide range of compatible types of sensors and screw connection terminals ensure high flexibility in installation.
- Unit protection: Special software features like compressor protection from fluctuation in the power supply or from high condensing temperature ensure the safe operation of the unit.
- Energy efficiency : Defrost on demand, day/night mode, and smart evaporator fan management ensure energy efficiency
User Interface
Dimensions (mm) and mounting
Electrical connections
Note : 2L and 3L must be connected to the same phase.
- Power connectors: wire size = 0.5 – 1.5 mm2, max. tightening torque = 0.4 Nm
- Low voltage signal connectors: wire size = 0.15 – 1.5 mm2, max. tightening torque = 0.2 Nm
Quick configuration at power-up
-
STEP 1: power on
-
STEP 2: select the quick configuration menu Within 30 seconds of power on, press “<” BACK for 3 seconds. The main switch “r12” is automatically set to OFF.
-
STEP 3: select pre-installed application o61 The display automatically shows the application selection parameter “o61” The digital inputs DI1 and DI2 can be configured for multiple functions (refer to Parameters “o02” and “o37”).
NC = Not configured
Press SET to select the pre-installed application. The display shows the default value (eg. “AP0” flashing). Choose the application type by pressing UP/DOWN and press SET to confirm. The controller presets parameter values according to the selected application and does not hide relevant parameters. Tip: you can easily move from AP0 to AP7, and thus select the simplified list of parameters, by pressing the UP key (circular list). -
STEP 4: select sensor type “o06 The display automatically shows the sensor selection parameter “o06”. Press SET to select the sensor type. The display shows the default value (eg. “n10” flashing). Choose sensor type by pressing UP/DOWN (n5=NTC 5 K, n10=NTC 10 K, Ptc=PTC, Pt1=Pt1000) and press SET to confirm.
Note: All sensors must be the same type. -
STEP 5: configure DO2 output “o71”
The display automatically shows the “o71” parameter to configure the “DO2” output. Select the required configuration (DEF or Lig or ALA) as per the application and press SET to confirm. The display returns to normal display mode and the control is started.
Quick Configuration via “cFg” Menu
- Press the “SET” button for 3 seconds to access the parameter menu (display will show “cFg”).
- Enter the “CFg” menu by pressing the “SET” button (display will show first parameter “r12” main switch.
- Select “r12” by pressing “SET” button again and set the main switch to “oFF” (r12=0).
- Press the back button (<) to come back to the ‘CFg” menu.
- Press the DOWN button to scroll through the “cFg” menu parameter list.
- Open the “061 application mode” and select the needed application mode (Press SET).
- Open the “007 Cooling/Heating” and select the needed function and press”SET” (applicable only for APO and AP5).
- Open the “006 Sensor type” and select the temperature sensor type used (n5=NTC 5 K, n10=NTC 10 K, Ptc=PTC, Pt1=Pt1000)- (Press “SET”).
- Open the “071 DO2 configuration” and select the function associated to DO2 output and press “SET”.
- Open the “002 DI1 Configuration” and select the function associated to digital input 1 (Press “SET”).
- Open the “037 DI2 Configuration” and select the function associated to digital input 2 (Press “SET”).
- Navigate back to parameter “r12 Main switch” and set it in “ON” position to start control.
- Go through other parameters’ default settings and change wherever needed.
Technical specifications
Features | Description |
---|---|
Purpose of control | Operating temperature sensing control suitable for |
incorporation into commercial air- conditioning and refrigeration applications
Construction of control| Incorporated control
Power supply| 115 V AC / 230 V AC 50/60 Hz, galvanic isolated low voltage
regulated power supply
Rated power| Less than 0.7 W
Inputs| Sensor inputs, Digital inputs, Programming key Connected to SELV
limited energy <15 W
Allowed sensors types| NTC 5000 Ohm at 25 °C, (Beta value=3980 at 25/100 °C –
EKS 211)
NTC 10000 Ohm at 25 °C, (Beta value=3435 at 25/85 °C – EKS 221)
PTC 990 Ohm at 25 °C, (EKS 111)
Pt1000, (AKS 11, AKS 12, AKS 21)
Sensors included in Kit Solution| NTC 10000 Ohm at 25 °C, cable length: 1.5 m
Accuracy| Measuring range:
-40 – 105 °C (-40 – 221 °F)
Controller accuracy:
±1 K below -35 °C, ±0.5 K between -35 – 25 °C
±1 K above 25 °C
Type of action| 1B (relay)
Output| DO1 – Relay 1:
16 A, 16 (16) A, EN 60730
10 FLA/60 LRA at 230 V, UL60730
16 FLA/72 LRA at 115 V, UL60730
DO2 – Relay 2:
8 A, 2 FLA/12 LRA, UL60730
8 A, 2 (2 A), EN60730
Features | Description |
---|---|
DO3 – Relay 3: |
3 A, 2 FLA / 12 LRA, UL60730-1
3 A, 2 (2 A), EN60730-1
Display| LED display, 3 digits, decimal point and multi-function icons, °C +
°F scale
Operating conditions| -10 – +55 °C (14 – 131 °F), 90% Rh
Storage conditions| -40 – +70 °C (-40 – +158 °F), 90% Rh
Protection| Front: IP65 (Gasket integrated) Rear: IP00
Environmental| Pollution degree II, non-condensing
Overvoltage category| II – 230 V supply version – (CE, UL recognized) III –
115 V supply version – (UL recognized)
Resistance to heat and re| UL94-V0
Temperature for ball pressure test statement According to Annex G (EN 60730-1)
EMC category| Emission: IEC/EN 61000 6-3
Immunity: IEC/EN 61000 6-2
Approvals| UL recognition (US & Canada) (UL 60730-1) CQC
CE (LVD & EMC Directive) EAC
NSF ROHS2.0
HACCP temperature monitoring in compliance with EN13485 Class I, when used with AKS 12 sensor
Parameter List
Function| Code| Min| Max| AP0| AP1| AP2|
AP3| AP4| AP5| AP6| AP7
---|---|---|---|---|---|---|---|---|---|---|---
Con guration| cFg|
Main switch ( -1=Service 0=OFF, 1=ON,)| r12| -1| 1| 1| 1| 1| 1| 1| 1| 1| 1
Pride ned applications| o612| AP0| AP7| AP0| AP1| AP2| AP3| AP4| AP5| AP6| AP7
Cooling/Heating (rE=Cooling, Ht= Heating)| o072| rE| Ht| rE| rE1| rE1| rE1|
rE1| rE1| rE| Ht1
Sensor type (n5=NTC 5K, n10=NTC10K, ptc=PTC, pt1=PT1000)| o062| n5| ptc| n10|
n10| n10| n10| n10| n10| n10| n10
DO2 con g (dEF=Defrost; ALA=alarm; Lig=Light)| o712| dEF| Lig| dEF| ALA1|
dEF1| dEF1| dEF1| dEF1| dEF| ALA
Reference| r- –|
Setpoint (unit: °C)| r00| -100| 200| 2| 4| 2| -20| 2| -24| 2| 50
Dierential (unit: K)| r01| 0.1| 20| 2| 2| 2| 2| 2| 2| 2| 4
Maximum set point limitation (unit: °C)| r02| -100| 200| 50| 6| 4| -18| 4|
-20| 50| 70
Minimum set point limitation (unit: °C)| r03| -100| 200| -35| 2| 0| -24| 0|
-26| -35| 30
Display o set (unit: K)| r04| -10| 10| 0| 0| 0| 0| 0| 0| 0| 0
Display Unit (°C/ °F)| r05| -C| -F| -C| -C| -C| -C| -C| -C| -C| -C
Calibration of Sair (unit: K)| r09| -20| 20| 0| 0| 0| 0| 0| 0| 0| 0
Main switch ( -1=Service 0=OFF, 1=ON,)| r12| -1| 1| 1| 1| 1| 1| 1| 1| 1| 1
Night Set back (unit: K)| r13| -50| 50| 0| 0| 0| 0| 0| 0| 0| 0
Reference displacement
o set temperature (unit: °C)
| r40| -50| 20| 0| 0| 0| 0| 0| 0| –| 0
Pull down duration (unit: min)| r96| 0| 960| 0| 0| 0| 0| 0| 0| –| –
Pull down limit temperature (unit: °C)| r97| -100| 200| 0| 0| 0| 0| 0| 0| –| –
- This option is a default setting in the controller and cannot be changed.
- This parameter can only be set when regulation is stopped, i.e. “r12” is set to 0.
Function| Code| Min| Max| AP0| AP1| AP2|
AP3| AP4| AP5| AP6| AP7
---|---|---|---|---|---|---|---|---|---|---|---
Alarm| A- –|
Delay for temp alarm during normal conditions (unit: min)| A03| 0| 240| 30|
45| 30| 30| 30| 30| 30| 10
Delay for temp alarm during pull-down/startup/defrost (unit: min)| A12| 0|
240| 60| 90| 60| 60| 60| 60| 60| –
High temp. alarm limit (unit: °C)| A13| -100| 200| 8| 10| 8| -15| 8| -15| 8|
80
Low temp. alarm limit (unit: °C)| A14| -100| 200| -30| 0| -2| -30| -2| -30|
-30| 20
DI1 delay (Time delay for selected DI1 function) (unit: min)| A27| 0| 240| 30|
30| 30| 30| 30| 30| 30| 30
DI2 delay (Time delay for selected DI2 function) (unit: min)| A28| 0| 240| 30|
30| 30| 30| 30| 30| 30| 30
Condenser High alarm limit (unit: °C)| A37| 0| 200| 80| 80| 80| 80| 80| 80| –|
–
Condenser High block limit (unit: °C)| A54| 0| 200| 85| 85| 85| 85| 85| 85| –|
–
Voltage protection enable| A72| no| YES| no| no| no| no| no| no| no| no
Minimum cut-in voltage (unit: V)| A73| 0| 270| 0| 0| 0| 0| 0| 0| 0| 0
Minimum cut-out voltage (unit: V)| A74| 0| 270| 0| 0| 0| 0| 0| 0| 0| 0
Maximum voltage (unit: V)| A75| 0| 270| 270| 270| 270| 270| 270| 270| 270| 270
Defrost| d- –|
Defrost Method (no=None, nAt=Natural, EL = Electric; gAS=Hot gas)| d01| no|
gAS| EL| nAt| EL| EL| EL| EL| EL| –
Defrost stop temperature (unit: °C)| d02| 0| 50| 6| –| –| –| 6| 6| 6| –
This option is a default setting in the controller and cannot be changed.
Function| Code| Min| Max| AP0| AP1| AP2|
AP3| AP4| AP5| AP6| AP7
---|---|---|---|---|---|---|---|---|---|---|---
Defrost Interval (unit: hour)| d03| 0| 240| 8| 6| 8| 12| 8| 12| 8| –
Max defrost Time (unit: min)| d04| 0| 480| 30| 45| 15| 15| 30| 30| 30| –
Defrost delay at power up (unit: min)| d05| 0| 240| 0| 0| 0| 0| 0| 0| NA| –
Drip delay (unit: min)| d06| 0| 60| 0| 0| 0| 0| 0| 0| 21| –
Fan delay after defrosting (unit: min)| d07| 0| 60| 0| 0| 0| 0| 0| 0| 51| –
Fan start temperature after defrosting (unit: °C)| d08| -50| 50| -5| 501| 501|
501| -5| -5| –| –
Fan during defrosting| d09| OFF| on| on| on| OFF| OFF| OFF| OFF| OFF| –
Defrost stop sensor non=None (Time), Air = Sair temp. sensor, dEF= S5 Defrost
sensor| d10| non| dEF| non| non1| non1| non1| dEF1| dEF1| non| –
Accumulated Compressor runtime to start defrost (0=OFF) (unit: hour)| d18| 0|
96| 0| 0| 0| 0| 0| 0| –| –
Defrost on demand (20=OFF) (unit: K)| d19| 0| 20| 20| 201| 201| 201| 20| 20|
–| –
Defrost delay after pull-down cycle (unit: min)| d30| 0| 960| 0| 0| 0| 0| 0|
0| –| –
Fan control| F- –|
Fan at compressor cutout (FAo=Fan always ON; FFC=Fan follow compressor; FPL=
Fan Pulsating)| F01| Fao| FPL| FAo| FAo| FAo| FAo| FAo| FAo| FAo| FAo
Fan stop evap. Temperature (unit: °C)| F04| -50| 50| 50| –| –| –| 50| 50| 50|
–
Fan ON Cycle (unit: min)| F07| 0| 180| 2| 2| 2| 2| 2| 2| 21| 2
Fan OFF cycle (unit: min)| F08| 0| 180| 2| 2| 2| 2| 2| 2| 21| 2
This option is a default setting in the controller and cannot be changed.
Function| Code| Min| Max| AP0| AP1| AP2|
AP3| AP4| AP5| AP6| AP7
---|---|---|---|---|---|---|---|---|---|---|---
Compressor| c- –|
Compressor / Heater minimum ON time (unit: min)| C01| 0| 30| 0| 0| 0| 0| 0| 0|
0| 0
Compressor /Heater minimum OFF time (unit: min)| C02| 0| 30| 2| 2| 2| 2| 2| 2|
2| 2
Compressor OFF delay at open door (unit: sec)| C04| 0| 900| 900| 900| 900|
900| 900| 900| 601| 900
Zero crossing selection (YES / no)| C70| no| YES| YES| YES| YES| YES| YES|
YES| YES1| YES
Others| o- –|
Delay of outputs at startup (unit: sec)| o01| 0| 600| 10| 10| 10| 10| 10| 10|
101| 10
DI1 con guration| o02| nC| Sc| nC| nC| nC| nC| nC| nC| nC| nC
Serial address (unit: No)| o03| 0| 247| 0| 0| 0| 0| 0| 0| –| 0
Password (unit: No)| o05| 0| 999| 0| 0| 0| 0| 0| 0| 0| 0
Sensor type (n5=NTC 5K, n10=NTC10K, ptc=PTC, pt1=PT1000)| o062| n5| ptc| n10|
n10| n10| n10| n10| n10| n10| n10
Cooling/Heating (rE=Cooling, Ht= Heating)| o072| rE| Ht| rE| rE1| rE1| rE1|
rE1| rE1| rE| Ht1
Display Resolution| o15| 0.1| 1.0| 0.1| 0.1| 0.1| 0.1| 0.1| 0.1| 0.11| 0.1
DI2 con guration| o37| nC| Pud| nC| nC| nC| nC| nC| nC| nC| nC
Light Control on= Always on, dAn = Day/Night,
doo=Based on door action
| o38| on| doo| on| on| on| on| on| on| on| on
Prede ned applications| o612| AP0| AP7| AP0| AP1| AP2| AP3| AP4| AP5| AP6| AP7
Save settings as factory WARNING: The earlier factory settings are
overwritten| o67| no| YES| no| no| no| no| no| no| –| no
- This option is a default setting in the controller and cannot be changed.
- This parameter can only be set when regulation is stopped, i.e. “r12” is set to 0.
Function| Code| Min| Max| AP0| AP1| AP2|
AP3| AP4| AP5| AP6| AP7
---|---|---|---|---|---|---|---|---|---|---|---
DO2 con g (dEF=Defrost; ALA=alarm; Lig=Light)| o712| dEF| Lig| dEF| ALA1|
dEF1| dEF1| dEF1| dEF1| dEF| ALA
Display during defrost Air=actual air temperature, FrE=freezed temperature,
-d-=”-d-” is displayed
| o91| Air| -d-| -d-| -d-| -d-| -d-| -d-| -d-| -d-1| –
Note : DI1 & DI2 configuration list as follows –
- nC= Not configured; Sdc = Status display output, doo = Door alarm with resumption,
- doA = Door alarm without resumption, SCH = Main switch, nig = Day/ Night mode,
- rFd = Reference displacement, EAL = External alarm, dEF = Defrost,
- Pud = Pull down; Sc = Condensor Sensor
- This option is a default setting in the controller and cannot be changed.
- This parameter can only be set when regulation is stopped, i.e. “r12” is set to 0.
Function| Code| Min| Max| AP0| AP1| AP2|
AP3| AP4| AP5| AP6| AP7
---|---|---|---|---|---|---|---|---|---|---|---
Polarity| P- –|
DI1 input polarity (nc / no) no = normally open,
nc = normally closed
| P73| no| nc| no| no| no| no| no| no| no| no
DI2 input polarity (nc / no) no = normally open,
nc = normally closed
| P74| no| nc| no| no| no| no| no| no| no| no
Invert alarm relay (0= normal,
1= invert relay action)
| P75| 0| 1| 0| 0| 0| 0| 0| 0| –| 0
Key board lock (no / yes) (0=no, 1=yes)| P76| no| YES| no| no| no| no| no| no|
–| no
Code| Alarms| Description
---|---|---
E29| Sair sensor error| Air temperature sensor error
E27| Def sensor error| S5 Evaporator sensor is defective or the electrical
connection is lost
E30| Sc sensor error| Sc Condenser sensor is defect or electrical connection
is lost
A01| High temp alarm| Air temperature in cabinet is too high
A02| Low temp alarm| Air temperature in cabinet is too low
A99| High Volt alarm| Supply voltage is too high (compressor protection)
AA1| Low Volt alarm| Supply voltage is too low (compressor protection)
A61| Condenser alarm| Condenser temp. too high – check air ow
A80| Cond. block alarm| Condenser temp. too high – manual reset of alarm
required1)
A04| Door alarm| Door has been open for too long
A15| DI Alarm| External alarm from DI input
A45| Standby Alarm| Control has been stopped by “r12 Main switch”
The condenser block alarm can be reset by setting r12 Main switch OFF and ON again or by powering down the controller.
Safety Standards
Check if the supply voltage is correct before connecting the instrument. Do
not expose to water or moisture: Use the controller only within the operating
limits avoiding sudden temperature changes with high atmospheric humidity to
prevent the formation of condensation.
Disposal of the Product
The appliance (or the product) must be disposed in accordance with the local
waste disposal legislation.
EU design registration
002566703-0001
DanfossA/S
- Climate Solutions
- danfoss.com
- +45 7488 2222
Any information, including, but not limited to information on selection of product, its application or use, product design, weight, dimensions, capacity or any other technical data in product manuals, catalogs descriptions, advertisements, etc. and whether made available in writing, orally, electronically, on line or via download, shall be considered informative and is only binding if and to the extent, explicit reference is made in a quotation or order confirmation. Danfoss cannot accept any responsibility for possible errors in catalogs, brochures, videos and other material. Danfoss reserves the right to alter its products without notice. This also applies to products ordered but not delivered provided that such alterations can be made without changes to the form, fit or function of the product.
All trademarks in this material are property of Danfoss A/5 or Danfoss group companies. Danfoss and the Danfoss logo are trademarks of Danfoss A/5. All rights reserved.
FAQ
Q: How many relays does the ERC 213 have?
A: The ERC 213 is equipped with 3 relays for versatile control options.
Q: What is the night mode icon for?
A: The night mode icon indicates an energy-saving mode for efficient operation
during specific hours.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>