ROBE Ambiane AP LED Light User Manual
- June 3, 2024
- ROBE
Table of Contents
- Ambiane AP LED Light
- Attention
- Installation
- DMX a nd DALI address setting and control
- RDM
- Anti-glare ring installation
- Adapter ring installation
- DMX protocols
- Technical specifications
- Included items
- Optional Accessories
- Maintenance
- Software update
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Ambiane AP LED Light
User Manual
Ambiane AP LED Light
User manual Ambiane AP (RGBW, RGBA, TD, PW, TW)
The unit generates light by means of high power LEDs. The unit was designed
for indoor use only.
Attention
The unit must be installed by a qualified electrician in accordance with all
national and local electrical and construction codes and regulations.
The unit was designed for indoor use only.
Avoid looking directly into the LED light beam at close range! Do not install
the unit near highly inflammable liquids or materials.
Do not allow anything to rest on the unit.
Do not install the unit near an open flame.
Do not install the unit in dirty,dusty or badly ventilated location.
Sufficient air accessing to the housing of the unit has to be ensured, there
must not be any heat or anti-noise insulation within a 0.6m x 0.6m area around
the unit (non-IC rated fixture).
Immunity of the equipment is designed for electromagnetic environments E1, E2,
E3 according to the standard EN55103-2 ed.2 Electromagnetic compatibility.
Product family standard for audio, video, audiovisual and entertainment
lighting control apparatus for professional use.
Part 2: Immunity.
The product (covers and cables) must not be exposed to a high frequency
electromagnetic field higher than 3V/m.
The installation company should check levels of possible interferences above
the tested levels E1,E2,E3 given by this standard (e.g. transmitters in
surrounding area) before installing the equipment. Emission of the equipment
complies with the standard EN55032 Electromagnetic compatibility of multimedia
equipment Emission Requirements according to class B. Suitable for fastening
on non-flammable surfaces only
Unsuitable for covering by heat insulation material
Always switch off power supply of the unit before connecting or disconnecting
the unit
Installation
-
Prepare a circular opening in the lower ceiling (1) as shown in the picture below.
-
Insert the Ambiane AP unit into the opening. Fasten the Ambiane AP by means of two spring fasteners (2) to the opening.
-
Connect needed cables to the Ambiane AP. Connection blocks (4) are placed on the PCB RB 3727 (3). The PCB is under plastic cover (5) which is fastened by means of two screws (6).
The primary power input serves for a standard power (e.g. Power Supply for
Ambiane AP).
The secondary power input serves for a backup power( in case that primary
power failed).
If both power inputs are under voltage, the primary power has a priority and
the secondary power is disabled.
In case of primary power loss, the secondary power is enabled.
If the Ambiane AP is supplied via the secondary power, the light intensity can
be set by the trimmer (9).
The Ambiane AP can be controlled by one of the following methods: DMX 512
DALI 0 – 10V (Ambiane PW, Ambiane TD only) The Ambiane AP is equipped with two
DMX and DALI connection blocks for easy connection to DMX or DALI chain
(In/Out method).
DMX connection
PCB| Function
0V –| Shield
D+| Signal (+)
D-| Signal (-)
0-10V connection
PCB | Function |
---|---|
0V | 0V |
D+ | +10V |
Power connection
PCB | Function |
---|---|
+ | Power + |
– | Power – |
DMX a nd DALI address setting and control
The DIP switch (7), located next to the connection blocks, allows you to run a
test light and switch the Ambiane AP to the update mode in case of software
update.
DIP 10 – if switched to ON=test light (3200K for RGBW and TW version)
DIP 11 – selection of fixture control: OFF=DMX 512 or DALI, ON=0-10V DIP 12 –
change from OFF to ON position switches the Ambiane AP to the update mode
(switching to the update mode is not necessary if the Robe Uploader is used
for Ambiane AP update).
DMX control
The DMX start address, is the first channel used to receive instructions from
the DMX controller. The address may be any channel from 1 to 509. DMX address
can be set either by DIP switch or by RDM. DMX address set by RDM overwrites
address set by DIP switch and vice versa. The green LED (8) on the PCB signals
way of DMX address setting:
LED lights-DMX address is set by means of the DIP switch.
LED does not light- DMX address is set by means of RDM.
DIP 11 has to be set in OFF position.
Example of DMX addresses:
DALI control
Addressing of the Ambiane AP is made by means of an external DALI controller.
The external DALI controller has to send activating command (8=ON) if you need
to start the permanent control of the Ambiane AP (Ambiane AP will not respond
to DMX commands) and deactivating command (0=OFF) to stop control of the
Ambiane AP. DIP 11 has to be set in OFF position.
Note: If DIP 11=OFF (Ambiane AP is controlled by DMX or DALI), the first
coming command switches the Ambiane AP to the corresponding operation mode
(DMX operation by a DMX command, DALI operation by a DALI command). E.g. the
Ambiane AP stays in a DALI operation and coming DMX command switches the
Ambiane AP to DMX operation. Next command is a DALI command and switches the
Ambiane AP to the DALI operation etc. If you need the permanent DALI
operation, you have to send a DALI command 8 to the Ambiane AP.
0-10V control
DIP 11 has to be set in ON position. 0-10V operation has priority to DALI
commands. The option is applicable for Ambiane PW and Ambiane TD only.
RDM
This Ambiane AP supports RDM operation. RDM (Remote Device Management) is a
bi-directional communication protocol for use in DM X512 control systems, it
is the new open standard for DMX512 device configuration and status
monitoring.
RDM allows you to set some options as DMX address, select DMX mode and readout
software version of the Ambiane AP etc.
Via RDM you can also set behaviour of the fixture in case of loss of DMX
signal. For this purpose serve the following two options:
DMX hold
Value On (0) – the fixture keeps last received DMX values in case of DMX loss
(default setting).
Value Off (1) – it activates the option ” DMX lost”. To set the option “DMX
hold” to Off, you have to send a value 1 via RDM.
DMX lost
The option is active only if the option “DMX hold” is set Off.
Value On (0) – the fixture lights at max. light output in case of DMX loss
(default setting).
Value Off (1) – The light output of the fixture is closed in case of DMX loss.
To set the option “DMX lost” to Off, you have to send a value 1 at RDM.
RDM model ID for the Ambiane AP is 0x0114.
Parameter ID | Discovery command | SET command | GET command |
---|---|---|---|
DISC_UNIQUE_BRANCH | ***** | ||
DISC_MUTE | ***** | ||
DISC_UN_MUTE | ***** | ||
DEVICE_INFO | ***** | ||
SUPPORTED_PARAMETERS | ***** | ||
SOFTWARE_VERSION_LABEL | ***** | ||
DMX_START_ADDRESS | ***** | ***** | |
IDENTIFY_DEVICE | ***** | ***** | |
DEVICE_MODEL_DESCRIPTION | ***** | ||
MANUFACTURER_LABEL | ***** | ||
DEVICE_LABEL | ***** | ***** | |
SENSOR_DEFINITION | ***** | ||
SENSOR_VALUE | ***** | ||
RESET_DEVICE | ***** | ||
DMX_PERSONALITY | ***** | ***** | |
DMX_PERSONALITY_DESCRIPTION | ***** | ||
SENSOR_VALUE | ***** | ***** | |
SENSOR DEFINITION | ***** |
Anti-glare ring installation
Insert the anti-glare ring (1) into the Ambiane AP until three locks (2) snap into slots (3).
Adapter ring installation
- Remove both spring fasteners (2) by unscrewing the four screws M4x10 (1).
- Slide the adapter ring (4) onto the housing of the Ambiane AP. Screw the new fasteners (3) on the housing.
Use original screws M4x10 (1).
DMX protocols
Ambiane RGBW , Ambiane RGBA
Version 1.2
Mode 1
Channel| Mode 2
Channe| Mode 3
Channe| Mode 4
Channe| Mode 5
Channe| Value| Function| Type of control
---|---|---|---|---|---|---|---
1| 1| 1| –| 1| 0-255| Red
Red LEDs saturation control 0% –>100%| proportional
–| –| 2| –| –| 0-255| Red Fine
Red LEDs saturation control from min. –>max.
| proportional
2| 2| 3| –| 2| 0-255| Green
Green LEDs saturation control 0% –>100%| proportional
–| –| 4| –| –|
0-255
| Green Fine
Green LEDs saturation control from min. –>max.| proportional
3| 3| 5| –| 3| 0-255| Blue
Blue LEDs saturation control 0% –>100%| proportional
–| –| 6| –| –| 0-255| Blue Fine
Blue LEDs saturation control from min. ->max.| proportional
4| –| 7| –| 4|
0-255
| White/Amber
White (Amber) LEDs saturation control 0% –>100%| proportional
–| –| 8| –| –| 0-255| White/Amber Fine
White(Amber) LEDs saturation control min. –>max.| proportional
–| –| 9| 1| –|
0
1-127
128
129-255
| Green White Fine
Uncorrected white
Minus green –> uncorrected white Uncorrected white (128=default) Uncorrected
white –> plus green| step proportional step proportional
–| –| 10| 2| –|
0
1-10
11-20
21-255
| Colour temperature correction (CTC)
No function (default) Tungsten dimming 3200K Tungsten dimming (3200K)
Colour temperature changing 2700K-6500K (21=2700K, 64-3200K, 128=4200K,
192-5600K,255=6500K)| step step step
proportional
–| –| 11| 3| 5| 0-255| Dimmer
Light intensity coarse 0% –>100%| proportional
–| –| 12| –| 6| 0-255| Dimmer Fine
Light intensity from min. –>max.| proportional
Ambiane PW, Ambiane TD
Version 1.1
Mode 1
Channel| Mode 2 Channel| Value| Function| Type of
control
---|---|---|---|---
1| 1| 0-255| Dimmer
Light intensity coarse 0% –>100%| proportional
–| 2| 0-255| Dimmer Fine
Light intensity from min. –>max.| proportional
Ambiane TW
Version 1.3
Mode 1
Channel| Mode 2
Channel| Mode 2
Channel| Mode 2
Channel| Value| Function| Type of
control
---|---|---|---|---|---|---
1| –| 1| –| 0-255| White colour selection
White from 2700K–>4000K| proportional
–| 1| –| 1| 0-255| Warm White
Warm White LEDs saturation control 0% –>100%| proportional
–| 2| –| 2| 0-255| Cool White
Cool White LEDs saturation control 0% –>100%| proportional
2| 3| 2| 3| 0-255| Dimmer coarse
Light intensity coarse 0% –>100%| proportional
–| –| 3| 4| 0-255| Dimmer Fine
Light intensity from min. –>max.| proportional
Technical specifications
Input voltage:………………48V DC
Protection class :…………….CE: ****(Class III )ETL: Class 2 or LVLE
Max. power consumption:…………..50W
Beam angle:……………..67°, 80° with anti-glare ring
Colour temperature
Ambiane PW……………………….2700K, 4000K
Ambiane TW………………………2700K,- 4000K
Ambiane TD……………………….3200K
Control:
Ambiane RGBW, Ambiane TW………….DMX, DALI, RDM compatible
Ambiane PW, Ambiane TD…………..DMX, DALI, 0-10V, RDM compatible
DMX channels:
Ambiane RGBW…………………………………..4 (Mode 1), 3 (Mode 2), 12 (Mode 3), 3 (Mode 4), 6
(Mode 5)
Ambiane PW, Ambiane TD………………..1 (Mode 1), 2 (Mode 2)
Ambiane TW……………………………………2 (Mode 1), 3 (Mode 2)
Typical Lumen maintenance:………………70%@ 50,000 hours
Led life expectancy:………………………minimum 50,000 hours
Operating ambient temp. range:………………-20°C/+45°C (-4F/+113F)
Operating temperature:…………………….75°C @ Ambient +35°C (167°F @ Ambient +95°F)
Total heat dissipation:…………………..136 BTU/h (calculated)
Cooling :…………………………………convection
Housing:………………………alluminium
Weight:…………………………..1.9 kg| (4.19 lbs)
Installation method:………………..via two spring fasteners
IC rating:…………………………………….non-IC rated
Power/DMX/DALI connection:……………………terminal blocks
Max. distance between Ambiane AP and Ambiane Power AP:…………….1m (for 2 x 18AWG
cable)
Protection factor:……………………..IP 20 (without diffuser glass), IP20/IP54 (with
Diffuser Glass)
Included items
1 x Ambiane AP
1x Anti-Glare Ring (P/N 10980386)
1 x Set of cable connectors
1 x User manual
Optional Accessories
Ambiane Power AP (P/N 10063994)
Anti-Glare Ring (P/N 10980386)
Adapter Ring (235-255mm ) (P/N 10980388)
Dimensions mm
[inch]
Maintenance
Keep the Ambiane AP clean, especially light source and the ribbed housing.
Software update
Software update of the fixture can be done by means of the ROBE Uploader. It
is a software for automatized software update of Robe and Anolis fixtures. It
takes advantage of RDM support.
The fixtures have to be connected in a daisy-chain (max. 32 fixtures) and via
the Robe Universal Interface/ Robe Universal Interface WTX and a USB cable
connected to the control PC with the Robe Uploader running. The control PC
should be connected to the Internet.
Note: If you do the software update by means of the Robe Uploader,
switching fixtures to the update mode (and from the update mode) is made
automatically, without need to switch the DIP 12 to ON position (update mode).
The Robe Uploader software cannot be used if fixtures are connected by means
of DALI connection.
The Robe Uploader software and user manual is available at :
https://www.robe.cz/robe-uploader/
Version 1.7
November 18, 2021
Specifications are subject to change without notice.
Made in CZECH REPUBLIC by ROBE LIGHTING s.r.o.
Palackeho 416/20 CZ 75701
Valasske Mezirici