Promate PC121812 Air Compressor Instruction Manual

July 25, 2024
PROMATE

Operator Manual AIR COMPRESSOR

PC121812 Air Compressor

IMPORTANT – Please make certain that persons who are to use this equipment thoroughly read and understand these instructions and any additional instructions provided before operation.

Record the model and serial numbers of your Air compressor below:

Model No.___ Serial No.____

FOREWORD
Thank you for purchasing Promate PC121812. This operator manual is for proper handling, minor checking, and maintenance of the PC121812. Before using your air compressor: Please read these instructions completely and carefully to operate it safely and make the best use of it. Due to constant efforts to improve our products, certain procedures and specifications are subject to change without notice, if you have any questions, please contact Promate Service.

Safety Precautions

When handling this unit, please keep to the following matters. Please make sure you review each precaution carefully. You must also make sure that the procedure, work method, or operating technique that you choose does not render the compressor unsafe.

Table 1. Safety Symbols and Meanings

V Volts Voltage
A Amperes Current
Hz Hertz Frequency (cycles per second)
W Watts Power
~ Alternating current Type of current
Direct current Type of characteristic of current
n0 No-load speed Rotational speed, at no load
lbs. Pounds Weight
…/min Per minute Revolutions, strokes, surface speed orbits, etc. per

minute
Icon| Class II construction| Double-insulated construction
| Read the operator’s manual| To reduce the risk of injury, read and understand the operator’s manual
| Wear safety glasses| Operation of power tools can result in foreign objects being thrown into the eyes
| Wear respiratory protection| Use of this tool can generate dust which may cause respiratory injury
| Wear hearing protection| Noise from this product can contribute to hearing loss
**| Wear gloves| Wear gloves to reduce the risk of injury
|
Safety Alert Symbol| Alert users to warning messages
|
Safety Alert Symbol: Danger| Failure to obey this warning WILL result in death or serious injury to yourself or others
|
Safety Alert Symbol: Warning| Failure to obey this warning CAN result in death or serious injury to yourself or others
|
Safety Alert Symbol: Caution**| Failure to obey this warning MAY result in death or serious injury to yourself or others

1.1 Safety Instructions
WORK AREA SAFETY

  1. Keep your work area clean and well-lit. Cluttered workbenches and dark areas invite accidents.
  2. Do not operate power tools in explosive atmospheres, such as in the presence of flammable liquids, gases, or dust. Power tools create sparks that may ignite the dust or fumes.
  3. Keep bystanders, children, and visitors away while operating a power tool. Distractions can cause you to lose control.
  4. Make your workshop childproof with padlocks and master switches. Lock tools away when not in use.
  5. Make sure the work area has ample lighting so you can see the work and that there are no obstructions that will interfere with the safe operation before using your power tool.

PERSONAL SAFETY

  1. Know your power tool. Read the operator’s manual carefully. Learn the power tools applications and limitations, as well as the specific potential hazards related to this tool.
  2. Stay alert, watch what you are doing, and use common sense when operating a power tool.
  3. Do not use tools while tired or under the influence of drugs, alcohol, or medication. A moment of inattention while operating power tools may result in serious personal injury.
  4. Dress properly. Do not wear loose clothing or jewelry. Pull back long hair. Keep your hair, clothing, and gloves away from moving parts. Air vents often cover moving parts and should also be avoided. Loose clothing, jewelry, or long hair can be caught in moving parts.
  5. Avoid accidental starting. Be sure the switch is in the “OFF” position before plugging in. Do not carry tools with your finger on the switch. Carrying tools with your finger on the switch or plugging in tools that have the switch in the “ON” position invites accidents.
  6. Remove adjusting keys or wrenches before turning the tool “ON”. A wrench that is left attached to a rotating part of the tool may result in personal injury.
  7. Do not overreach. Keep proper footing and balance at all times. Proper footing and balance enable better control of the tool in unexpected situations.
  8. Always secure your work. Use clamps or a vise to hold work when practical. It is safer than using your hand and frees both hands to operate the tool.
  9. Use safety equipment. Always wear eye protection. Dust masks, non-skid safety shoes, hard hats, or hearing protection must be used for appropriate conditions.
  10. Do not use a ladder or unstable support. Stable footing on a solid surface enables better control of the tool in unexpected situations.

TOOL USE AND CARE SAFETY

BE SURE to read and understand a instructions before operating this powe tool.

  1. Always use clamps or other practical ways to secure and support the workpiece to a stable platform. Holding the work by hand or against your body is unstable and may lead to loss of control.
  2. Do not force the tool. Use the correct tool and blade for your application. The correct tool and blade will do the job better and safer at the rate for which it is designed.
  3. Do not use the tool if the switch does not turn it “ON” or “OFF”. Any tool that cannot be controlled with the switch is dangerous and must be repaired.
  4. Disconnect the plug from the power source before making any adjustments, changing accessories, or storing the tool. Such preventive safety measures reduce the risk of starting the tool accidentally.
  5. Never leave the tool running. Always turn it off. Do not leave the tool until it comes to a complete stop.
  6. Store idle tools out of the reach of children and other untrained persons. Tools are dangerous in the hands of untrained users.
  7. Maintain tools with care. Keep cutting tools sharp and clean. Properly maintained tools with sharp cutting edges are less likely to bind and are easier to control.
  8. Check for misalignment or binding of moving parts, breakage of parts, and any other condition that may affect the tool’s operation. If damaged, have the tool serviced before using. Many accidents are caused by poorly maintained tools.
  9. Use only accessories that are recommended for this tool. Accessories that may be suitable for one tool may become hazardous when used on another tool.

ELECTRICAL SAFETY

  1. Avoid body contact with grounded surfaces such as pipes, radiators, ranges, and refrigerators. There is an increased risk of electric shock if your body is grounded.
  2. Do not expose power tools to rain or wet conditions. Water entering a power tool will increase the risk of electric shock.
  3. Do not abuse the cord. Never use the cord to carry the tool or pull the plug from an outlet. Keep the cord away from heat, oil, sharp edges, and moving parts.
  4. Replace damaged cords immediately. Damaged cords increase the risk of electric shock.

Diagram 1. Electrical Safety Guide

NOTE
This compressor should be used on a nominal 220V grounded circuit. Use a power cord that is equipped with a grounding plug. Verify that the compressor is plugged into an outlet that has the same configuration as the plug. Do not use an adaptor with this compressor.

EXTENSION CORDS

Keep the extension cord clear of the working area. Position the cord so that it will not get caught on lumber, tools, or other obstructions while you are working with a power tool.

Check the extension cords before each use. Never use the tool with a damaged cord since touching the damaged area could cause electrical shock, resulting in serious injury.

As the distance from the supply outlet incre you must use a heavier gauge extension Using the extension cords with inadequately wire causes a serious drop in voltage, resulti loss of power and possible product damage. to the table below to determine the req minimum wire size.

MINIMUM GAUGE FOR EXTENSION CORDS

(When using 220 volts only)
Ampere Rating| Total Length Of Cord
More Than< >Less Than| 25ft.| 50ft.| 100ft.| 150ft.
0| 6| 18| 16| 16| 14
6| 10| 18| 16| 14| 12
10| 12| 16| 16| 14| 12
12| 16| 14| 12| Reco Not nded mme

Diagram 2. Minimum Gauge for Extension Cords

Parts and Specifications

Read this owner’s manual before operating your air compressor. Familiarize yourself with the location and function of the controls and features. Save this manual for future reference.

Diagram 3. Air Compressor Parts

Table 2. General Specifications

Model No.: PC121812
Motor: 220V’, 60Hz, Universal
Running Horsepower: 1.8 HP
Input Power: 1700W
Tank Size: 12 Gallons / 45 Liters
Air Delivery: 4.0 CFM @ 90 PSI
Maximum Pressure: 175 PSI / 12 BAR
Pump Design: Oil-free, Direct Drive
Power Cord: SJT 16AWG 3C X 1.8m
Net Weight: 30 kg
Gross Weight: 32 kg
Unit Dimensions (LxWxH): 535 x 470 x 840 mm

Tool Compatibility Chart

Table 3. Tool Compatibility Chart

RECOMMENDED TOOL USAGE

Refer to specific tool requirements
Inflation/Recreation| | |
Air Brush|
| |
Caulking| | |
Cleaning|
| |
Nailer/Stapler| | |
Brad Nailer|
| |
Spray Gun (20-45 PSI)| | |
Screwdriver|
| |
Grease Gun| | |
Impact Wrench|
| |
Ratchet| | |
Finish Nailer|
| |
Spray Gun (30-70 PSI)| | |
Framing Nailer|
| |
Flooring Nailer| | |
Air Drill|
| |
Sand Blaster| | |
Cut-Off Tool| |
|
Air Hammer| | |


| Recommended Use| | Intermittent Use| | Not Recommended

SAVE THESE INSTRUCTIONS

Check the manufacturer’s maximum pressure rating for air tools and accessories. The regulator outlet pressure must never exceed the maximum pressure rating.

Important Information

This air compressor is ideal for a wide range of job site applications. The 12-gallon design provides optimum pressure. It features a 1.8 HP universal motor and an oil-free pump. The procedures described in this manual are solely for the PC121812 air compressor at a maximum pressure of 175 PSI.

NOTE
Always ensure the use if appropriately matched air tools with your air compressor. Be sure that the air compressor being used can supply the appropriate volume, pressure, and delivery rate of air to the tool(s) without running continuously. Using tools or combinations voids the air compressor guarantee/warranty.

Product Features

Electric Motor
The motor is used to power the pump. It is equipped with a thermal overload protector. If the motor overheats for any reason, the thermal overload protector will shut down to prevent the motor from being damaged.

Air Compressor Pump
The pump compresses the air and discharges it into the tank via the piston that moves up and down in the cylinder.

Safety Valve
This valve is used to prevent the compressor from building too much pressure. If the pressure reaches the preset level of the motor, it will automatically pop open. You can also pull the ring on the valve to open manually.

Air Pressure Regulator
The regulator is used to adjust the pressure inside the line to the tool that is being used. Turn the knob clockwise to increase the pressure and counter- clockwise to decrease the pressure.

Tank Pressure Gauge
The gauge measures the pressure level of the air that is stored in the tank. It cannot be adjusted by the operator and it does not indicate the pressure inside the line.
The gauge measures the regulated outlet pressure.

Air Outlet (Universal Coupler)
The outlet is connected to the ¼” (6.4 mm) NPT air hose.

Tank Drain
The tank drain is used to remove moisture from the air tank after the compressor is shut off.

Air Tank
The tank is where the compressed air is stored.

Power Cord
This compressor should be used on a nominal 220V grounded circuit. Use a power cord that is equipped with a grounding plug. Verify that the compressor is plugged into an outlet that has the same configuration as the plug. Do not use an adaptor with this  compressor.

Assembly

  • Unpack the air compressor unit. Inspect the unit for damage. If the unit has been damaged, contact the retailer immediately.
  • Check the air compressor’s identification label to ensure that you have purchased the intended model and that it has the required pressure rating for its intended use.

6.1 Packaging Contents

DESCRIPTION QTY ILLUSTRATION
Air Compressor 1
Owner’s Manual 1

Table 4. Packaging Contents

6.2 Positioning of the Air Compressor FIG.

  1. Position the air compressor (1) near an electrical outlet (2) (FIG. A).
  2. The compressor must be at least 12” (31cm) from any wall (3) or obstruction, in a clean, well-ventilated area to ensure sufficient airflow and cooling (FIG. A).
  3. Place the air compressor on the floor or a hard, level surface.

OPERATION

7.1 Before Starting
Check Safety Valve
Before starting the compressor, pull the ring on the safety valve to make sure that the safety valve operates freely. If the valve is stuck or does not operate smoothly, contact a trained service technician (Fig. B).

7.2 Starting the Compressor

  1. Set the power switch to the OFF position (Fig. C).

  2. Turn the air pressure regulator knob counter-clockwise until it stops (Fig. D).

  3. Connect the air hose (1) to the compressor’s air outlet (universal coupler) (2) with the universal quick plug (3) (Fig. E). NOTE
    Attach the air hose and accessories (not provided). Apply a plumber’s tape on all the threads to prevent air leakage.

  4. Attach the hose and accessories (Fig. F).
    High-pressure air could result in death or serious injury. Never operate above the maximum operating pressure of the spray gun or tool.

Hot compressor surfaces could result in serious injury. Allow the compressor to cool before touching it.
NOTE
If the pump has been transported or turned upside down (even partially), allow the pump to sit in a normal, upright position (Fig. A) for approximately 10 minutes before starting.
4. Close the tank drain (1). Plug in the power cord (2) (Fig. G).

  1. Set the power switch to the ON position and allow the tank pressure to build. The motor will stop when tank pressure reaches cut-out pressure (Fig H).

7.3 Stopping the Compressor

  1. Set the power switch (1) to the OFF position.
  2. Unplug the power cord (2).
  3. Reduce the pressure in the tank through the outlet hose. Pulling the safety valve ring (3) and keeping it open will also reduce the pressure in the tank (Fig. I).
  4. Set tank drain (4) (Fig. I) to OFF to ensure the tank is drained.

Risk of serious eye injury from moisture and debris. Always wear ANSI Z87.1 safety goggles when opening the tank drain.
High-pressure air could result in death or serious injury. Shut off the unit, unplug, and release air pressure before servicing.

High-pressure air containing water condensation could result in minor or moderate injury. Do not spray at any person.

7.4 Draining the Tank

  1. Set the power switch to the (OFF) position.
  2. Turn the regulator knob counter-clockwise to set the outlet pressure to zero.
  3. Pull and hold the ring on the safety valve, allowing air to bleed from the tank until air pressure is minimized.
  4. Place a suitable container under the unit to catch any water.
  5. Slightly tilt the unit and turn the tank drain counter-clockwise to open.
  6. After the water has been drained, close the tank drain (clockwise) and store safely.

MAINTENANCE AND STORAGE

Table 5. Maintenance and Storage

TASK DESCRIPTION SERVICE INTERNAL
Drain the tank To prevent corrosion inside the tank, the condensation must be

drained at the end of every workday. Be sure to wear protective goggles. Relieve the air pressure in the system and then open the drain valve on the bottom of the tank.| Daily
Check the relief valve| Pull the relief valve on the ring daily to ensure that it is operating properly and to clear the valve of any possible obstructions.| Daily
Test for leakage| Check all connections to see if tight. A small leak of any part (the tank, hoses, pipe connections or transfer tubes) will reduce| Monthly
Storage| Before storing the unit for a long period, use an air blow gun to clean all the dust and debris from the compressor. Disconnect and coil the power cord. Pull the pressure relief valve to release all pressure from the tank. Drain all moisture from the tank. Cover the entire unit to protect it from moisture and dust.| Before prolonged storage

Always shut off and unplug the unit and relieve all air pressure from the system before performing.

TROUBLESHOOTING

Table 6. Troubleshooting

PROBLEM POSSIBLE CAUSE SOLUTIONS
The motor will not run or start The power cord is not plugged in. Plug the

power cord into a grounded outlet.
The power switch is in the O (OFF) position.| Set the power switch to the ON position.
The extension cord is the wrong wire gauge or is too long.| Check extension cord information (page 3) for the proper wire gauge and cord length.
The motor’s thermal overload protection has tripped.| Turn the air compressor off, unplug the power cord, and wait until the motor has cooled down. Plug in the power cord only after the motor has cooled down, and wait for at least 5 minutes to make sure the thermal overload protector has recovered.
A fuse has blown or a circuit breaker has been tripped.| Replace the fuse or reset the circuit breaker.
Verify that the fuse has the proper amperage.
Check for low voltage conditions.
Disconnect any other electrical appliances from the circuit or operate the compressor on a dedicated circuit.
The air tank pressure exceeds the preset power switch limit.| The motor will start automatically when the tank pressure drops below the cut-in pressure.
The safety valve is stuck open.| Clean or replace the safety valve.
Electrical connections are loose.| Contact an authorized service center.
The motor, capacitor, or safety valve is defective.| Contact an authorized service center.
The motor runs continuously when the power switch is in the ON position.| The power switch does not shut off the motor when the air compressor reaches the cut-out pressure and the safety valve activates.| Set the power switch to the OFF position. If the motor does not shut off, unplug the air compressor. If the power switch is defective, replace it.
The compressor’s capacity is not enough.| Check the air requirements of the accessory that is being used. If it is higher than the CFM (Cubic Feet per Minute) and pressure supplied by the compressor (page 4), a larger capacity air compressor is needed. Most accessories are rated at 25% of actual CFM

while running continuously.

The regulator does not      regulate the pressure.| The regulator or its internal parts are dirty or damaged.| Replace the regulator.
The pressure is low or there is not enough air.| There is a leak at one of the fittings.| Check the fittings with soapy water. Tighten or reseal leaking fittings (apply plumber’s tape on threads). Do not over-tighten.
The tank drain is open.| Close the tank drain.
The air intake is restricted.| Clean or replace the air filter element.
Prolonged excessive use of air.| Decrease the amount of air used.
There is a hole in the air hose.| Check the air hose and replace it if necessary.
The tank leaks.| Replace the tank immediately. Do not attempt to repair it.
The valve is leaking.| Check for worn parts and replace them if necessary.
There is moisture in the discharged air.| There is condensation in the air tank caused by a high level of atmospheric humidity or because the air compressor has not been running long enough.| Drain the air tank after each use. Drain the air tank more often in humid weather and use an air-line filter.
The compressor overheats.| The ventilation is inadequate.| Relocate the compressor to an area with cool, dry, and well-circulated air.
Cooling surfaces are dirty.| Clean all cooling surfaces on the pump and the motor thoroughly.
The valve is leaking.| Replace worn parts and reassemble using the new plumber’s tape.

SERVICE INFORMATION

HOW TO ORDER REPLACEMENT PARTS
Even quality-built equipment such as the air compressor you have purchased will need occasional replacement parts to maintain its good condition over the years.
To order replacement parts and consumable parts, please contact Promate Service and be ready with the following information:

  1. Model No., Serial No. and all specifications that are shown on the Model No./Serial No. plate.
  2. Part numbers or numbers as shown in the Parts List section ().
  3. A brief description of the trouble with the air compressor.

LIMITED WARRANTY
Warranty Coverage:
Powertech Asia Pacific Inc., (the Company) warrants to the original retail customer that it will repair or replace, free of charge, any parts found by the Company or its authorized service representative to be defective in material or workmanship. This warranty covers the cost of replacement parts and labor for defects in material or workmanship.

Not Covered:
a. Shipping/Handling charges for sending the product to the Company or its authorized service representative for warranty service.
Shipping/Handling repaired or replaced products to the customer; these charges must be borne by the customer.
b. If a separate operator’s manual and engine warranty from the engine manufacturer is included with this product, only that warranty will apply to the engine.
c. Damage caused by abuse, accident, the effects of corrosion, erosion, and normal wear and tear.
d. Warranty is void if the customer fails to install, maintain, and operate the product in accordance with the instructions and recommendations of the Company set forth in the owner’s manual, or if the product is used as rental equipment.
e. The Company will not pay for repairs or adjustments to the product, or for any costs of labor performed without the Company’s prior authorization.
f. Consumable parts such as battery, spark plugs, and air cleaner

Warranty Period: One (1) year from the date of purchase on products used solely for consumer applications; if a product is used for business or commercial applications, the warranty period will be limited to ninety (90) days from the date of purchase. For warranty service, the customer must provide dated proof of purchase and must notify the company within the warranty period.
EXCLUSIONS AND LIMITATIONS: THE COMPANY MAKES NO OTHER WARRANTY OF ANY KIND, EXPRESS OR IMPLIED. IMPLIED WARRANTIES, INCLUDING WARRANTIES OF MERCHANTABILITY AND OF FITNESS FOR A PARTICULAR PURPOSE, ARE HEREBY DISCLAIMED. THE WARRANTY SERVICE DESCRIBED ABOVE IS THE EXCLUSIVE REMEDY UNDER THIS WARRANTY; LIABILITY FOR INCIDENTAL AND CONSEQUENTIAL DAMAGES IS EXCLUDED TO THE EXTENT PERMITTED BY LAW.
This warranty gives you specific legal rights, and you may also have other rights which vary from state to state. Some states do not allow a disclaimer of implied warranties or the exclusion or limitation of incidental and consequential damages, so the above disclaimers and exclusions may not apply.


CONTACT THE POWERTECH Asia Pacific Inc.,

PRODUCT SERVICE DEPARTMENT AT (02) 8 984 2620 | (+63) 9338373922
service@powertechasiapacific.com www.facebook.com/PromateServicePH/

(MAIN) #420 Diamond Warehouse Compound, F Legaspi St., Maybunga Pasig City 1607
(DAVAO) Space 10 & 11 Jin-Long Complex R. Castillo St. Agdao District, Davao City 800

EXPLODED VIEW AND PARTS LIST

Diagram 13. PC121812 Exploded View

Table 7. PC121812 Parts List

NO. Description Qty NO. Description Qty
1 Pressure Switch 1 17 Wheel 2
2 Motor Pump Assembly 1 18 Ball Valve 1
3 Screw M5x10 3 19 Rubber Foot 2
4 Ground Wire 1 20 Tank 1
5 Flange Bolt M5x12 1 21 Lower Cover 1
6 Control Panel 1 22 External Serrated Lock Washer φ5 2
7 Pressure Gauge 2 23 Cushion Pad 3
8 Pressure Regulator 1 24 Air Filter 1
9 Safety Valve 1 25 Flat Washers φ8 3
10 Tee Fitting 1 26 Check Valve 1
11 Quick Coupler 2 27 Hexagon Socket Bolt M8x35 3
12 Screw M5x14 2 28 Hose 1
13 Crimping Board 1 29 Elbow Fitting 1
14 Power Cord 1 30 Upper Cover 1
15 Handle Cover 1 31 Screw ST3.9x16F 10
16 Cotter Pin 2 32 Power Switch 1

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals