cata 6430 Wh Hood Energy Efficiency Class Instructions
- July 18, 2024
- cata
Table of Contents
cata 6430 Wh Hood Energy Efficiency Class
Specifications
- Model: TFH6430, TFH6630, TFH6830
- Dimensions: 200+A x 190 x 8 mm
- Weight: 70g
- Size: A5
Product Usage Instructions
- Reset the hood by switching off the power for 60 seconds and then switch it back on.
- Press the button for 5-10 seconds. The button will flash red while other buttons display white and remain fixed.
- Use the or button to select the FW. Press the timing button for more than 2 seconds to confirm. The button will flash red and stay fixed for 5 seconds before returning to standby mode.
- Reset the hood by switching off the power for 60 seconds and then switch it back on.
- Simultaneously press and for more than 3 seconds. All indicators should stay fixed.
IMPORTANT – Please read carefully the separate safety guide before use.
Parts And Tools
Dimension
USE
CARE & MAINTENANCE
Warning: always switch off the electricity supply before carrying out
maintenance work on the hood. In the event of a fault, contact an official
distributor or authorized dealer.
Cleaning the outside: use liquid, non-corrosive detergent and avoid using
abrasive cleaning products and solvents. Do not use high-pressure or steam
cleaning devices.
Important: increase the filter cleaning/replacement frequency if the hood
is used for more than 2 hours a day. Always use genuine filters from the
manufacturer.
Grease cleaning
To avoid fires, clean thoroughly once a month or whenever the display pilot
light indicates as such. To do so, remove the filters and wash them with hot
water and detergent. If using a dishwasher (metal parts may turn black without
this affecting their functional capacity), load the filters vertically to
avoid solid residue from being deposited.
MONTH
FAQS
Problem | Possible cause | Solution |
---|---|---|
Excessive vibration. | The appliance is not installed properly on the | |
brackets. | Take down the appliance and check it is properly fixed. | |
The fan blade is damaged. | Switch off the appliance. Repair is to be carried |
out by qualified service personnel only.
The fan motor is not fixed tightly.
The light is on, but the fan does not work.| The fan blade is jammed.
The motor is damaged.
Both the light and motor do not work.| The light bulb has blown.| Contact
Customer Services on.
The power connection is loose.| Check the power supply.
Suction performance reduced.| Speed may be too low.| Select a higher speed.
Aluminum filters are dirty.| Clean the aluminum filters. (See Care
and maintenance section).
The top vent might be obstructed.| Clear any obstruction.
An optional vent kit might be twisted.| Ensure that the vent kit is fitted
according to the
manufacturer’s instructions.
The installation may not comply with the
manufacturers instructions.
| The vent hose should be the correct diameter throughout with no reductions
or restrictions. (See installation section).
Works normally but the cooking smells linger.| The carbon filter is not fitted
in Fit carbon filter or replaces the recirculation mode or is full of carbon
filter (See Care and grease. maintenance section).
The hood does not work| Check that the hood is connected to power. Check that
the fuses or automatic have not jumped.
The hood still does not work| If, after having checked the points mentioned
above, your problem has not yet been solved, contact the technical service or
your distributor.
OLD PROTOCOL
-
Reset the Hood switching off the power for 60’’ and then switch on again; the Hood starts with “stand by”.
-
Press the button between 5 or 10 seconds. The button flashes red.
Other buttons display white and are fixed. The display keeps off. -
Operate or button to select the FW. Then press the timing button for more than 2 seconds to confirm. The button flashes red and is fixed for 5 seconds to return to the standby.
MODELS WITH OLD PROTOCOL SWITCH CONTROL
NEW PROTOCOL
- Reset the Hood switching off the power for 60’’ and then switch on again; the Hood starts with “stand by”.
- Press and more than 3 seconds at the same time. When all the buttons start to flash white, the display keeps off. The hood is in setting mode.
- Press the button in the setting state, and will flash red, the other buttons are fixed in white, and the display shows the FW number previously set.
- Select the FW through the button, and press the button again to confirm. At this time, the button is fixed in red for 5 seconds, and then it will return to the setting again (all buttons flash in white, and the display keeps off).
- Let the Hood turn off and return to standby mode.
MODELS WITH NEW PROTOCOL SWITCH CONTROL
CONTACT
- CATA ELECTRODOMÉSTICOS, S.L.
- Oficinas: c/ Anabel Segura, 11, Edif. A, 3a pl. 28108. Alcobendas. Madrid. España
- Fábrica: c/ del Ter 2, Apdo. 9. 08570. Torelló.Barcelona. España
- T. +34 938 594 100 – Fax +34 938 594 101
- www.cnagroup.es – cna@cnagroup.es
- Atención al Cliente: 902 410 450 / +34 938 521 818 – info@cnagroup.es
- International SAT – www.cnagroup.es/warranty
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>