Oliveri ACC186-W Bottle Trap Instruction Manual
- July 17, 2024
- Oliveri
Table of Contents
ACC186-W Bottle Trap
Instruction Manual
Installation Instructions
BOTTLE TRAP
Product code: ACC186-W-CR/ACC186-W-MB/ACC186-W-BN/ACC186-W-CG/ACC 186-W-GM
Technical Data
This Bottle trap must be installed by a licensed plumber, installation must
comply with AS/NZS 3500 and local plumbing codes.
This Oliveri Bottle Trap is manufactured to standard AS 1589
Installation Instructions
The inlet of this bottle trap is compatible with a 40mm waste connection. The
outlet key seal of this bottle trap is designed to suit a 40mm PVC DWV socket.
- Cut the DWV Pipe so that between 1mm to 5mm protrudes through the wall or vanity cabinet back. Ensure the pipe is cut square and deburr.
- Connect Bottle trap inlet pipe (2) to the waste outlet using Sealing washer (1) and compression Nut (3). Do not fully tighten; adjustment will be needed during installation.
- Apply plumber’s grade lubricant or soapy water to one end of the Outlet pipe (10). Fit Key seal (12) onto the end of Outlet pipe (10).
- Insert the assembled Outlet pipe (10) and Key seal (12) into DWV pipe, until Key seal’s raised lip meets the DWV pipe.
- Loosen Compression nut (4) then adjust height of Bottle trap inlet pipe (2). Note: Ensure a minimum 1.5° fall (per AS/NZS 3500.2).
- Position the Bottle trap outlet towards the DWV pipe. Measure the Outlet pipe and make a mark 30mm past the face of Compression nut (3), to ensure sufficient length for sealing. Cut the Outlet pipe (10) at the mark using a pipe cutter and deburr. Slide the Wall flange (11) onto the Outlet pipe.
- Disconnect Bottle trap from waste outlet. Assemble Outlet pipe (10) to Bottle trap using Tapered washer (9) and Compression nut (3). Do not fully tighten.
- Lubricate Key seal (9) on end of Outlet pipe, Push Key seal and Outlet pipe into DWV pipe.
- Re-fit Bottle trap to the waste outlet. Adjust Bottle trap position and height, then tighten all connections.
- Fill basin with water, test for correct function, and check for leaks.
Care & Maintenance
Avoid using abrasive or acid based cleaning products.
To clean the bottle waste trap, unscrew the large threaded Bung (8) at the
base of the bottle trap. Clean any waste from the bottle trap, clean the
O-ring seal (7) and reassemble the threaded Bung (8).
WARRANTY:
This Bottle Trap is warranted to be free from manufacturing defects for a
period of: 1 Year replacement of parts, seals, finish and labour
This warranty does not cover against normal wear and will be voided if the
product is misused or not installed in accordance with these instructions.
In the event this product is rendered obsolete and a replacement product is
required.
Oliveri Solutions Pty Ltd reserves the right to supply a product of equal
substitution at their discretion.
Our goods come with guarantees that cannot be excluded under the Australian
Consumer Law. You are entitled to a replacement or refund for a major failure
and for compensation for any other reasonably foreseeable loss or damage. You
are also entitled to have the goods repaired or replaced if the goods fail to
be acceptable quality and the failure does not amount to a major failure.
SERVICE
If the Bottle trap requires servicing, please contact your installer
(preferably the one who installed it). If the installer is satisfied that the
problem is not due to poor installation, contact Oliveri’s nominated service
agent for assistance on:
Ph: (08) 8348 6444
Email: warranty@oliveri.com.au
For full warranty information visit: https://oliveri.com.au/service-and-
warranty
If a warranty service call finds that the product does not have a genuine
manufacturing fault, our Warranty Service Agent reserves the right to pass on
any call-out fee to the householder.
2024-01/Version2.0