Oliveri VI201C-G Vienna Back To Wall Care Toilet Suite User Manual

May 15, 2024
Oliveri

Oliveri VI201C-G Vienna Back To Wall Care Toilet Suite

Oliveri-VI201C-G-Vienna-Back-To-Wall-Care-Toilet-Suite-
PRODUCT

Product Specifications:

  • Model: Vienna Back To Wall Care Toilet Suite
  • Standards: AS 1172.1, AS 1172.2, AS 1428.1
  • Dimensions: Refer to specific model variations
  • Date: 29 Nov 2022
  • Revision Number: 1.0

Product Usage Instructions

Before Installation:

  • Before starting the installation process, ensure you have checked the product for any damage. If damaged, return it to the store of purchase. Make sure all components required for installation are included.
  • This product must be installed by a licensed plumber following the provided instructions. Failure to do so will void the warranty.

Installation Steps:

  1. Mark the centre line of the pan connector on the floor or wall depending on the S trap or P trap installation.
  2. Place the pan in position and mark the entry points for floor-fixing holes.
  3. Drill and screw into place the floor fixing brackets ensuring they are 40mm inside the marked line.
  4. Ensure the pan is level and square to the wall. Use floor chocks if necessary for stabilization.
  5. Install the Variance Bend with a set-out of 140mm to 250mm.
  6. If installing as a bottom entry inlet, refer to bottom entry cistern installation.
  7. Slide the pan into place, ensuring full engagement of the Variance Bend.
  8. Screw the pan in place using supplied fixing screws without over-tightening to avoid cracking.

Cistern Installation:

  1. Place the cistern onto the pan with a sponge gasket on the outlet valve tail and connect using attachment bolts evenly tightened.
  2. Connect the Female Flexi Connector from the side entry inlet valve to the 1/2 BSP inlet Stand Pipe in the cistern tank.
  3. Connect the Female Flexi Connector to the Stand Pipe from the underside of the pan and feed through the appropriate pan hole.
  4. Slide the pan and cistern into place following the steps for pan installation.

FAQ:

  • Q: Can I install the toilet myself without a licensed plumber?
    A: This product is to be installed only by a licensed plumber to ensure proper installation and warranty coverage.

  • Q: What should I do if I notice damage to the product upon inspection?
    A: If you find any damage, return the product to the store of purchase for a replacement or refund.

This Oliveri toilet is manufactured to Australian standard AS 1172.1, AS1172.2

Dimension

Oliveri-VI201C-G-Vienna-Back-To-Wall-Care-Toilet-Suite-FIG-
\(1\) Oliveri-VI201C-G-Vienna-
Back-To-Wall-Care-Toilet-Suite-FIG- \(2\)

Back To Wall Care Toilet Suite
VI201C-G : VI201C-P / VI201C-C / ACC201-4CG / ACC201-7CG VI201C-B : VI201C-P / VI201C-C / ACC201-6CB / ACC201-8CB

BEFORE YOU BEGIN

Check the product for damage. If the product is damaged return to the store of purchase. Check the product is complete with all components required to install. This product is to only be installed by a licensed plumber and must be installed by these instructions, failing to do so will void the warranty.

WARNING : DO NOT BED THE PAN IN PLACE USING CEMENT, CONCRETE OR SIMILAR MATERIAL, DOING SO WILL VOID THE PRODUCT WARRANTY.

  1. Mark the centre line of the pan connector on the floor for “S” trap installation or on the wall for “P” trap installation.

  2. Place the pan into position centralising the pan on your centre line. Draw around the pan base and mark the entry points on the floor to where the floor-fixing holes are on the side of the pan.

  3. Remove the pan and drill and screw into place the floor fixing brackets. Set the floor fixing brackets 40mm inside the line drawn around the base of the pan. Use suitable floor-fixing screws and toggles to suit the floor material.

  4. Critical: The pan must be on a level surface and square to the wall. If the floor slopes away, the pan will need to be levelled using suitable floor chocks around the pan to support and stabilise the pan.

  5. The standard Variance Bend supplied has a set out of 140mm to 250mm.

  6. “S” Trap Installation: Place the Variance Bend into the floor outlet, from the finished floor to the centre of the pan outlet is 180mm. Ensure the Variance Bend is straight and square to the wall and centralised to the pan outlet height. Assemble the Variance Bend wall brace and fix to the finished wall. Measure the distance from the back edge of the pan to the “P” trap edge and add on sufficient length for the Variance Bend collar to fully engage the “P” trap.
    Remove the locking ring and rubber boot from the Variance Bend. The distance between each ridge on the Variance Bend is 10mm. Once the excess has been cut off the Variance Bend, reassemble the rubber boot and locking ring.

  7. lf the suite is being installed as a bottom entry inlet, refer to bottom entry cistern installation before sliding the pan into place.

  8. Slide the pan into place being careful that full engagement of the pan Variance Bend has been achieved. N.B. Pre-soaping the rubber boot on the Variance Bend will assist with easier engagement of the Variance Bend.

  9. Once the pan is in place and connected to the Variance Bend, screw the pan in place using the supplied fixing screws and cover.

DO NOT OVER-TIGHTEN SCREWS AS THIS MAY CAUSE THE PAN TO CRACK.

CISTERN INSTALLATION

BOTTOM ENTRY ONLY (Preassembly requirement before connecting pan to Variance Bend)

  1. Locate the cistern onto the pan with the sponge gasket placed on the cistern outlet valve tail and connect the tank to the pan using attachment bolts.
    (N.B. Cistern-to-pan assembly bolts are to be tightened down evenly, alternating between the left and right bolt until the cistern and pan have china-to-china contact). DO NOT OVER TIGHTEN.

  2. Assemble the supplied Female Flexi Connector from the side entry inlet valve to the 1/2″ BSP inlet Stand Pipe located in the cistern tank.

  3. From the underside of the pan connect the 1/2″ BSP Female Flexi Connector to the bottom of the Stand Pipe and feed the other end through the left or right-hand side pan hole depending on which side the mains pressure inlet is located.

  4. Slide pan and cistern into place following points 8 & 9 in the pan installation section.

  5. Connect the flexible hose to the water control valve.

  6. Place the cistern lid on top of the cistern and check the push button operation.

  7. Assemble the seat using the seat assembly instructions supplied with the seat.

  8. Run a bead of neutral cure plumber’s grade silicone around the pan and up the edge of the wall to finish off.

BACK ENTRY ONLY

  1. With the pan in place, locate the cistern onto the pan with the sponge gasket placed on the cistern outlet valve tail and connect the tank to the pan using attachment bolts. Ensure that the cistern and pan have china to china contact. (N.B. Cistern-to-pan assembly bolts are to be tightened down evenly, alternating between the left and right bolt until the cistern and pan have china-to-china contact).
    DO NOT OVER TIGHTEN.

  2. Assemble the water control valve to the 1/2″ BSP inlet thread.

  3. Connect the supplied Female Flexi Connector to the water control valve.
    DO NOT OVER TIGHTEN.

  4. Place the cistern lid on top of the cistern and check the push button operation.

  5. Assemble the seat using the seat assembly instructions supplied with the seat.

  6. Run a bead of neutral cure plumber’s grade silicone around the pan and up the edge of the wall to finish off.

DO NOT USE OFFSET PAN COLLARS ON ‘S’ OR ‘P’ TRAP INSTALLATIONS AS THIS WILL COMPROMISE WASTE DISCHARGE. DOING SO WILL VOID THE PRODUCT WARRANTY.
IMPORTANT : Sand and debris move through water pipes. Always flush the line before connecting the toilet suite inlet pipe to the water control valve.

CARE & MAINTENANCE

Avoid using abrasive or acid-based cleaning products.

WARRANTY

This toilet is warranted to be free from manufacturing defects for a period of:

  • 10 years of pan and cistern replacement parts and 1 year of labour.
  • 5 years of seat replacement parts and 1 year of labour.
  • 1-year valves, fittings, and labour

Subject to the terms contained in the full warranty information available at https://oliveri.com.au/service-and-warranty, where a genuine manufacturing defect arises within the warranty period Oliveri will, at its election, repair the defect or replace the product.
This warranty does not cover against normal wear and will be voided if the product is misused or not installed by these instructions.
Our goods come with guarantees that cannot be excluded under the Australian Consumer Law. You are entitled to a replacement or refund for a major failure and for compensation for any other reasonably foreseeable loss or damage. You are also entitled to have the goods repaired or replaced if the goods fail to be of acceptable quality and the failure does not amount to a major failure.

SERVICE

If the product requires servicing, please contact your installer (preferably the one who installed it). If the plumber/installer is satisfied that the problem is not due to poor installation, contact Oliveri’s nominated Warranty Service Agent for assistance on:
Ph: 08 8348 6444 (choose the after-sales service and warranty option)
Email: warranty@oliveri.com.au
For full warranty information visit: https://oliveri.com.au/service-and- warranty
If a warranty service call finds that the product does not have a genuine manufacturing fault, our Warranty Service Agent reserves the right to pass on any call-out fee to the householder.

Oliveri Solutions Pty Ltd ABN 12 007 551 886