airkave AHD01 Room Air Sanitizer Instruction Manual

June 6, 2024
airKave

airkave AHD01 Room Air Sanitizer Instruction Manual

airkave AHD01 Room Air Sanitizer Instruction Manual

1 OVERVIEW

airkave AHD01 Room Air Sanitizer Instruction Manual -
OVERVIEW

2 KEY FEATURES

airkave AHD01 Room Air Sanitizer Instruction Manual - KEY
FEATURES

3 PACKAGE CONTENT

  1. airKAVE ROOM
  2. Fine Dust PM 2.5 filter (Type: E12 or H13)
  3. Air-vent Large Dust filter (Washable)
  4. Power supply adapter
  5. Manual & Warranty Card
  6. Magnetic Feet (x4)

4 QUICK START

Preparation before use:

  1. Plug power supply adapter into wall socket
  2. Plug barrel type connector into ROOM’s back power port
  3. Press or   Button until LED indicator turns green
  4. Tap button to change sanitization power level

5 SAFETY PRECAUTIONS

airkave AHD01 Room Air Sanitizer Instruction Manual - SAFETY
PRECAUTIONS

6 OPERATION GUIDE

6.1 Function Button

Tap or to turn ON the ROOM.
To turn OFF, press and hold for a few seconds.
Tap to cycle the modes, LED will flash to different colours when cycled.

6.2 Mode Selection

Immediately after turning on, default mode is set to Manual.

airkave AHD01 Room Air Sanitizer Instruction Manual - Mode
Selection

6.3 Mode Indicator

airkave AHD01 Room Air Sanitizer Instruction Manual - Mode
Indicator

In Manual, Timer and Program mode, sanitization power levels can be adjusted manually from the ROOM interface.
In Econ mode, sanitization power level is automatically set and cannot be manually adjusted.

6.4 sanitization Power Levels

In Manual, Program and Timer modes, press to cycle through the power levels.

In Program mode, you can configure each schedule to a specific sanitization power level, for any time and day. For more details, see: 7.6 Configure: Program

In Econ mode, sanitization power level is automatic and cannot be manually changed during operations.

airkave AHD01 Room Air Sanitizer Instruction Manual - sanitization Power
Levels

6.5 sanitization Power Indicator

sanitization power LEDs are shown in GREEN. Mode LED will be shown in different colours. See: 6.3 Mode Indicator

airkave AHD01 Room Air Sanitizer Instruction Manual - sanitization Power
Indicator

7 WIFI CONTROLS

Remotely control and customise settings for Timer & Program mode from a web browser on a PC, Mobile or Android app from google Play Store. Step-by-Step Control Guide, please see: 11.4 Support Plug Power Supply into the ROOM & the Wall Socket WIFI Hotspot (WIFI4 / 2.4GHz) will turn on automatically when connected to power supply. Ensure the Indicator LED is lit RED.

7.1 Quick Connect Guide

airkave AHD01 Room Air Sanitizer Instruction Manual - Quick Connect
Guide

https://play.google.com/store/apps/details?id=com.aonetech.airhalo

7.2 Control Panel
  • On/Off ­ Turn the ROOM to Standby mode
  • Mode/Power Status ­ Display current status here
  • Modes ­ Switch to Manual/Timer/Program/Econ
  • Power Level ­ User can take manual control
  • Advance Panel ­ Access by “Gear” icon (Top Right)
  • Logout ­ Return to login page “Cross” icon (Top Left)

Switch modes to Manual, Timer, Program or ECON: Click Manual, Timer, Program or ECON button to activate. You can change to manual mode by:

  1. Click “manual” button or Select a sanitization power level
  2. Press button to apply manual mode
7.3 Advance Panel
  • Device Name ­ Display name of the ROOM
  • Login Password ­ Set custom password
  • Configure ­ Configure options for specific modes
  • System ­ Configure device settings
  • Bright ­ Set the brightness of the LEDs indicator
  • Reset ­ Apply factory default

Set new Device Name and/or Login Password:

  1. Select the ROOM name/Login Password field
  2. Enter a new alphanumeric entry
  3. Click “Apply” to set new name/password
  4. Click “Back” to return to Control Panel

Set specific options from the Configure and System group. Clicking on the button will take you to the specific panel options.

LED Brightness can be set for all indicator LEDs Ranging from “Off”, “Dim”, “Normal” or “Bright”

Set Brightness:

  1. Select brightness option from drop down menu
  2. Selection will be applied immediately

Reset – !Warning!
Selecting this option will restore all software to factory default.
Please see for more details: 11.1 Troubleshooting

7.4 Configure: Timer

Timer mode automatically shutdown the ROOM within a set duration when activated. Configure the duration of the timer in hours and minute incrementation:

  1. Select hours from 00hrs to 24hrs and Select minutes from 00mins to 59mins
  2. Select sanitization power level by tapping button
  3. Click “Apply”
  4. Click “Back” to return to Advance Panel
7.5 Configure: Program

Enable PROGRAM mode from OFF mode:
Press twice to select Program mode: press to cycle sanitization power level until ROOM enters OFF mode. Please see for further details: 6.4 sanitization Power Levels

Program allows ROOM scheduling for the entire week. Set time, day of the week and the sanitization power level.
Please ensure the Time and Day is set to your time zone before utilising PROGRAM mode.

To configure:

  1. Select the time in hours and minutes (HH:MM am/pm)
  2. Select the sanitization power level (Off / Silent / Low / Normal / Boost)
  3. Select the day or days (Monday to Sunday)
  4. Click “Apply”
  5. Click “Back” to return to Advance Panel

Delete a schedule, click “Delete” on the far right side. 30 programs can be scheduled. For further details please go to our website for the latest manual: www.air-halo.com

7.6 System: Clock

To ensure Program mode is running correctly, set ROOM to your current time zone. To configure:

  1. Set Hours, Minutes and AM/PM
  2. Set date (DD-MM-YYYY)
  3. Click “Apply”
  4. Click “Back” to return to Advance Panel
7.7 System: Network

Connect to WIFI HOTSPOT for First Time Initiation of ROOM Default format is Product No. + Serial No. ( “AHD01SXXXX” ). This can be found on the product label. The Hotspot operate on the 2.4GHz band. SSID name and password is fully customisable.

WIFI Local Area Network (WLAN) on a home router
WLAN is compatible with WPA and WPA2 encryption To connect:

  1. Click “Search WIFI” to discover available networks
  2. Click “SSID” to select desired network
  3. Enter password
  4. Click “Apply” or “Reboot”

Multiple ROOM’s can connect to the same WIFI Local Area Network (WLAN) on a home network.

The WLAN IP of the ROOM will be displayed on the Login page

7.8 System: Firmware

Customer support may direct user to update the firmware if required. Please see : 11.4 Support

8 MAGNETIC FEET

airkave AHD01 Room Air Sanitizer Instruction Manual - MAGNETIC
FEET

9 MAINTENANCES

9.1 Cleaning Recommendation

Before cleaning, please switch OFF & Unplug Power Supply

  • Surfaces: Slightly damp cloth
  • In/out-vent Metal Mesh: cloth & vacuum
  • Large Dust Filter: vacuum & rinse with water (periodically)
9.2 Surfaces

Use a slightly damp cloth to wipe clean any blemish or dirt on the surface.

9.3 In & Out-vent Mesh

Vacuum the mesh carefully, use a cotton bud to remove dust from between the vents.

9.4 Large Dust Filter
  1. Position horizontally with left-side panel on top
  2. Lift the top side panel & gently remove large dust filter
  3. Wash clean with water & dry thoroughly before replacing
  4. Vacuum clean any dust or obstruction within
  5. Align large dust filter with “tabs” facing outwards and push down until it clicks
  6. Close the top side panel until it clicks

airkave AHD01 Room Air Sanitizer Instruction Manual - Large Dust
Filter

9.5 Fine Dust Filter Replacement

It is recommended to replace fine filter (Type: E12 or H13) every 6-9 months. Before replacement, carefully vacuum around and inside the interior.

CAUTION: Do not remove Fine Dust filter without unplugging power supply first. To replace the fine dust filter, position with left-side panel on top:

airkave AHD01 Room Air Sanitizer Instruction Manual - Fine Dust Filter
Replacement

  1. Lift the front edge of the left-side panel
  2. Grip firmly to remove and pull out the fine dust filter
  3. Align replacement filter and push until it is flush
9.6 Fine Dust Filter Disposal

When fine dust filter is full, do not incinerate. Disposed separately from household waste.

9.7 Repair

Maintenance by user is not advised. For more details please see: 11.2 Warranty

10 SPECIFICATIONS

  • Model: AHD01
  • Modes: Manual / Timer / Program / ECON
  • sanitization Power Levels: Silent / Low / Normal / Boost
  • WIFI: 802.11 b/g/n @ 2.4GHz (WIFI 4)
  • Weight: 5kg
  • Air sanitizer: Plascide Technology
  • Recommend Usage: 250ft2
  • Supply: 100-220V@50/60Hz | Output: 12V = 5A
  • Consumption: 60W
  • Dimension (283 x 333 x 140)mm

11 SERVICE & SUPPORT

11.1 Troubleshooting

airkave AHD01 Room Air Sanitizer Instruction Manual -
Troubleshooting

11.2 Hard Reset

If you have exhausted all possible solutions to fix your problem. You can perform a hardware reset to restore the factory defaults Plug Power Supply into the ROOM & the Wall Socket:

airkave AHD01 Room Air Sanitizer Instruction Manual - Hard
Reset

  1. Lift up left side panel
  2. Locate the first hole labelled: “Recover”
  3. Insert a pen or screwdriver
  4. Press down firmly for a second
11.3 Warranty
  • ROOM is covered by a manufacturer guarantee and warranty
  • Self-repair and/or signs of tampering will void the warranty
  • Repairs should only be carried out by a certified person
  • Please refer to the included warranty card for more details
11.4 Support

For latest documentation: support@airkave.com
Please contact your local service centre:
T: 800-873-1038| W: WWW.AIRKAVE.COM|

KAVE INDUSTRIES LLC
8605 Santa Monica Blvd #53476, Los Angeles, CA 90069

Caution: This device complies with part 15 of the FCC Rules, Industry Canada license-exempt RSS standard(s) and with Part 18 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. The manufacturer is not responsible for any radio or TV interference caused by unauthorized modifications or change to this equipment. Such modifications or change could void the user’s authority to operate the equipment.

Airkave and the included wireless Hotspot has been tested and found to satisfy the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. Airkave generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment on and off, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and receiver.
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help.

The device has been evaluated to meet general RF exposure requirement. To maintain compliance with FCC’s RF exposure guidelines, the distance must be at least 20 cm between the radiator and your body.

The included wireless airkave has been tested and found to comply with the applicable limits under Part 18 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference to licensed radio services. However, the airkave generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. There is no guarantee that interference will not occur in a particular installation. If this airkave does cause harmful interference to radio or television reception, or to another authorized radio service, which can be determined by turning the Charger off and on, the user is encouraged to correct the interference by one or more of the measures described immediately above.

IC Warning: This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may
not cause harmful interference, and (2) this device must accept any interference, including interference that may cause undesired operations of the device. The device has been evaluated to meet general RF exposure requirement. To maintain compliance with RSS-102 — Radio Frequency (RF) Exposure guidelines, this
equipment should be installed and operated with a minimum distance of 20cm between the radiator and your body.

Advisory Statement: This product may cause interference to radio equipment and should not be installed near maritime safety communications equipment or other critical navigation or communication equipment operating between 0.45-30 MHz.

UL Warning: To reduce the risk of injury, user must read instruction manual. Use only with Listed/Certified ITE Power Supply
FCC ID: 2AZLG-AHD01R | FCC ID: 2AZLG-AHD01M| IC ID: 27178-AHD01

Plascide®
Plasma Technology