Oliveri VI202C-G Vienna Wall Faced Care Toilet Suite Instruction Manual
- May 15, 2024
- Oliveri
Table of Contents
Vienna
This Oliveri toilet is manufactured to Australian standard AS 1172.1, AS1172.2
Technical Data
Installation Instructions
Vienna
Wall Faced Care Toilet Suite
VI202C-G : VI202C / ACCIWRTC / ACC201-4CG
VI202C-B : VI202C / ACCIWRTC / ACC201-6CB
BEFORE YOU BEGIN
Check the product for damage. If the product is damaged return to the store of
purchase.
Check the product is complete with all components required to install. This
product is to only be installed by a licensed plumber, and must be installed
in accordance with these instructions, failing to do so will void warranty.
CISTERN INSTALLATION
Refer Oliveri Inwall Cistern (ACCIWRTC) installation guide together with the
dimensional pan drawing on this document for correct installation.
You must refer to the INWALL CISTERN INSTALLATION GUIDE in conjunction with
this installation document to ensure the toilet suite is installed correctly.
PAN INSTALLATION
WARNING: DO NOT BED THE PAN IN PLACE USING CEMENT, CONCRETE OR SIMILAR
MATERIAL, DOING SO WILL VOID THE PRODUCT WARRANTY.
-
Mark the centre line of the pan connector on the floor for “S” trap installation or on the wall for “P” trap installation.
-
Place the pan into position centralising the pan on your centre line. Draw around the pan base and mark the entry points on the floor to where the floor fixing holes are on the side of the pan.
-
Remove the pan and drill and screw into place the floor fixing brackets. Set the floor fixing brackets 40mm inside the line drawn around the base of the pan. Use suitable floor fixing screws and toggles to suit the floor material.
-
Critical: The pan must be on a level surface and square to the wall. If the floor slopes away, the pan will need to be levelled using suitable floor chocks around the pan to support and stabilise the pan.
-
The standard Variance Bend supplied has a set out of 140mm to 250mm.
-
“S” Trap Installation: Place the Variance Bend into the floor outlet, from the finished floor to the centre of the pan outlet is 180mm. Ensure the Variance Bend is straight and square to the wall and centralised to the pan outlet height. Assemble the Variance Bend wall brace and fix to the finished wall. Measure the distance from the back edge of the pan to the “P” trap edge and add on sufficient length for the Variance Bend collar to fully engage the “P”trap.
Remove the locking ring and rubber boot from the Variance Bend. The distance between each ridge on the Variance Bend is 10mm. Once the excess has been cut off the Variance Bend, reassemble the rubber boot and locking ring. -
Slide the pan into place being careful that full engagement of the pan Variance Bend and cistern Flush Pipe has been achieved. N.B. Pre-soaping the rubber boot on the Variance Bend and key seal on the Flush Pipe will assist with easier engagement.
-
Once the pan is in place and connected to the Variance Bend and Flush Pipe, screw the pan in place using the supplied fixing screws and cover.
DO NOT OVER TIGHTEN SCREWS AS THIS MAY CAUSE THE PAN TO CRACK. -
Assemble the seat using the seat assembly instructions supplied with the seat.
-
Run a bead of neutral cure plumber’s grade silicone around the pan and up the edge of the wall to finish off.
DO NOT USE OFFSET PAN COLLARS ON ‘S’ OR ‘P’ TRAP INSTALLATIONS AS THIS WILL
COMPROMISE WASTE DISCHARGE. DOING SO WILL VOID THE PRODUCT WARRANTY.
IMPORTANT: Sand and debris move through water pipes. Always flush the
line prior to connecting toilet suite inlet pipe to the water control valve.
Service and Warranty
CARE & MAINTENANCE
Avoid using abrasive or acid-based cleaning products.
WARRANTY
This toilet is warranted to be free from manufacturing defects for a period
of:
10 years pan replacement parts and 1 year labour.
5 years cistern and seat replacement parts and 1 year labour.
1 year valves, fittings, and labour
Subject to the terms contained in the full warranty information available at https://oliveri.com.au/service-and-warranty, where a genuine manufacturing defect arises within the warranty period Oliveri will, at its election, repair the defect or replace the product.
This warranty does not cover against normal wear and will be voided if the product is misused or not installed in accordance with these instructions.
Our goods come with guarantees that cannot be excluded under the Australian Consumer Law. You are entitled to a replacement or refund for a major failure and for compensation for any other reasonably foreseeable loss or damage. You are also entitled to have the goods repaired or replaced if the goods fail to be of acceptable quality and the failure does not amount to a major failure.
SERVICE
If the product requires servicing, please contact your installer (preferably
the one who installed it). If the plumber / installer is satisfied that the
problem is not due to poor installation, contact Oliveri’s nominated Warranty
Service Agent for assistance on:
Ph: 08 8348 6444 (choose the after sales service and warranty option)
Email: warranty@oliveri.com.au
For full warranty information visit: https://oliveri.com.au/service-and-
warranty
If a warranty service call finds that the product does not have a genuine manufacturing fault, our Warranty Service Agent reserves the right to pass on any call-out fee to the householder.
Oliveri Solutions Pty Ltd ABN 12 007 551 886
51 Naweena Rd, Regency Park SA 5010 P 08 8348 6444 E
sales@oliveri.com.au
Date: 29 Nov 2022. Revision Number 1.0
VI202C-G / VI202C-B
Installation Instructions