HOZELOCK EasyClear 3000/4500 All in One Filter System Instruction Manual
- July 16, 2024
- HOZELOCk
Table of Contents
- HOZELOCK EasyClear 3000/4500 All in One Filter System
- Product Usage Instructions
- INSTALLATION & OPERATING INSTRUCTIONS
- Overload Protection
- Installation
- Accessory Assembly
- Maintenance
- 3 Year Product Guarantee
- Technical Information
- INSTALLATION & OPERATING INSTRUCTIONS
- Overload Protection
- Installation
- Hozelock Cyprio Clearwater Guarantee
- Technical Information
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
HOZELOCK EasyClear 3000/4500 All in One Filter System
Specifications :
- Model: EASYCLEAR 3000/4500
- Manufacturer: Hozelock Ltd.
- Designed for: Submersible use in outdoor ponds
- Features: Mechanical & Biological Filtration, Ultra Violet Clarifier, Fountain or Waterfall
- Electric Cable Length: 10m
- Electric Cable Specifications: 3-core, minimum copper
cross-section of 0.75mm2 with Polycloroprene-Rubber insulation
Product Usage Instructions
Installation :
- Read all instructions carefully before installation.
- Ensure the appliance is disconnected from the electricity supply during installation.
- Handle the clear tube made from quartz glass with care during installation and maintenance.
- Do not remove the pump unit from its outer housing as it may void the warranty.
- Permanently wire the product to the mains supply using a 3-core cable with specified specifications.
Operating Instructions:
- Ensure the UV-C emitter is properly installed in the housing before operation.
- Avoid running the product dry to prevent damage.
- Check the operation of the UV lamp by observing a bluish glow from the Fountain outlet in dark conditions.
- Never operate the UV-C emitter outside of the appliance housing.
- Keep the appliance out of reach of children and persons with reduced capabilities.
Safety Guidelines:
- Always unplug all appliances from the electricity supply before touching water during installation or maintenance.
- Use the filter only for garden ponds; do not use it in swimming pools or other applications.
- Avoid operating visibly damaged appliances.
- Wear suitable eye protection and gloves when handling the quartz glass tube.
FAQ:
-
Q: Can I operate the UV-C emitter outside of the appliance housing?
A: No, it is important to keep the UV-C emitter installed in the appliance housing to prevent exposure to dangerous UV-C radiation. -
Q: How should I check if the UV lamp is operational?
A: Look for a bluish glow from the Fountain outlet when the lamp is switched on in dark conditions. -
Q: Can children use this product without supervision?
A: No, this appliance should only be used by or under the supervision of a responsible adult. -
Q: What should I do if the appliance is visibly damaged?
A: Do not operate visibly damaged appliances; contact customer support for assistance.
EASYCLEAR 3000/4500
- Hozelock Ltd.
- Midpoint Park, Birmingham, B76 1AB. England
- Tel: +44 (0) 121 313 1122
- www.hozelock.com
- 33902-000
Thank you for choosing a Hozelock quality product, you can be assured of many years of reliable service from this product.
INSTALLATION & OPERATING INSTRUCTIONS
FAILURE TO OBSERVE THE FOLLOWING NOTICES MAY RESULT IN INJURY, PRODUCT DAMAGE
OR LOSS OF FISH.
KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE.
The Hozelock Cyprio EasyClear™ Fountain or Waterfall pump is designed for
submersible use in outdoor ponds. It is an integrated unit that provides
Mechanical & Biological Filtration with an Ultra Violet Clarifier and a
Fountain or Waterfall.
Attention: UV Caution
- This appliance contains a UV-C emitter. Unintended use of the appliance or damage to the housing may result in the escape of dangerous UV-C radiation. UV-C radiation may, even in little doses, cause harm to the eyes and skin. The lamp is fitted with an interlock that will turn the lamp off when the bayonet is removed (fig 8-S).
- When switched on, the lamp can be checked for operation in dark conditions, by looking for a bluish glow from the Fountain outlet (Fig 1-A). Do not run the product dry.
- Warning: Do not attempt to operate the UV-C emitter when it is removed from the appliance housing.
- Warning: The appliance must be disconnected from the supply before replacing the UV-C emitter.
Important
- This appliance must only be used by or under the supervision of a responsible adult who is capable of using the appliance in a safe way and who understands the hazards involved.
- Use and store this appliance out of reach of children and persons with reduced physical, sensory, or mental capabilities.
Warning:
Safety & Electrical Connections
-
WARNING: ALWAYS UNPLUG OR DISCONNECT ALL APPLIANCES IN THE POND FROM THE ELECTRICITY SUPPLY BEFORE PUTTING YOUR HANDS IN THE WATER WHILST EQUIPMENT IS BEING INSTALLED, REPAIRED, CARRYING OUT ANY
MAINTENANCE OR BEING HANDLED IN ANY WAY. -
This filter has been designed for the use with garden ponds only. Do not use this filter for any other use (i.e. do not use this filter in swimming pools, etc). Using the product for any other application may result in injury or product damage. This pump must not be used when people are in the water.
-
Appliances that are obviously damaged must
not be operated. -
The clear tube inside the unit is made from quartz glass and care should be taken during installation and maintenance. We recommend the use of eye protection and suitable gloves.
-
Do not remove and operate the pump unit from its outer housing. Using the unit without its outer housing may invalidate your warranty.
-
Important: This product is supplied with 10m of 3-core electric cable . It is designed to be permanently wired to the mains supply. For connection to the mains supply use only 3-core cable (ref HO5 RN-F). This has a minimum copper cross-section of 0.75mm2 with Polycloroprene-Rubber insulation.
The termination to the mains supply should be:- Permanent.
- Inside a dry weatherproof enclosure.
- Through a double pole switched fused spur to BS 3676.
- Fitted with a 3 or 5 amp fuse.
-
If an extension cable is required, this should be connected to the end of the unit cable using
a weatherproof connector. The joint must be positioned in a suitable weatherproof housing. The extension cable should be of 3 core 0.75mm2 Polychloroprene rubber insulated cable (ref: HO5 RN-F) and permanently wired to the mains supply as described above in 1.6. -
WARNING: This appliance MUST be earthed and it is essential that the connections are made using the following code:
- BROWN – live
- BLUE – neutral
- GREEN/YELLOW – earth.
-
Exposed cable runs should be sensibly positioned and protected by armoured conduit, especially if there is a risk of contact with gardening equipment such as forks and lawnmowers, or children and domestic animals.
-
Do not operate this product if the mains supply cable has become damaged in any way. The supply cable is permanently connected and sealed to the pump and cannot be replaced. If the cable is damaged, the unit should be disposed of according to local regulations.
-
A 30mA maximum Residual Current Device (RCD) MUST be fitted to the mains supply.
-
Permanent installations to the mains supply (hard wiring), must conform to the national and local wiring regulations. If in any doubt about wiring to the mains supply, consult a qualified electrician or local electricity authority.
-
Do not use the supply cable to lift the unit, as this may cause damage. We recommend fitting a lifting cord to the hook feature on the base, when the filter is installed in deep water. (Fig 1-H). If the product needs to be moved, the product should be switched off and lifted out of the water using this cord.
-
Do not switch the pump on out of water! The water level should be above the UVC indicator at the ball joint (Fig 4A-L).
-
Do not operate or leave the unit in freezing conditions. (See the section, “Winter Storage”).
-
This product is not suitable for water temperatures above 35ºC or below 0ºC.
-
Only use accessories which have been designed for use with this product. The use of any other accessories or spares may invalidate your guarantee.
Installing this product in the garden is classed as ‘notifiable’ in the Regulations for England and Wales. The Regulations require you to tell your local authority building control department that you intend to install this product before installation. Your local authority will let you know how you can get your installation approved.
Overload Protection
- To help ensure your EasyClear’s long life and to prevent damage, it is fitted with automatic thermal overload protection. This switches the pump or UV lamp off if either overheats. If this occurs, switch off the power at the mains supply to the unit. If it is the pump that has activated the Overload Protection, check for the cause (it is usually debris blocking the inlet of the pump or obstructing the impeller). Remove the obstruction and wait 15 minutes for the unit to cool down. Then switch it on again.
- If it is the UV lamp that is activating the overload protection (pump is still running but UV lamp keeps going out after running for a short time), please contact Hozelock Consumer
- Services Helpline on +44 (0)121 313 1122.
- Remember: The lamp is fitted with an interlock that will turn the lamp off when the bayonet is removed (fig 8-S), so you can only see if the lamp is working in dark conditions, by looking for a bluish glow from the Fountain outlet (Fig 1-A) with the bayonet tube locked in position.
- NOTE: YOU MUST SWITCH OFF THE MAINS SUPPLY BEFORE THE UNIT WILL RESET.
- CAUTION: To avoid a safety hazard due to inadvertent resetting of the thermal overload protection, this product must not be used with an external switching device, such as a timer, or connected to a circuit that is regularly switched on and off by the electricity supply.
Periods of Operation
Keep the filter working 24 hours a day. Ideally it should run all year
round, but at least throughout the fish-feeding season, (i.e. until the water
temperature falls below 10°C and the fish stop feeding). In winter, operating
the unit will maintain a basic level of useful bacteria in the Biological
Filter, and will help prevent the pond icing over. However, the unit must not
be allowed to freeze. If you switch the unit off for winter, wash the unit
thoroughly before resuming filtration in the spring (see ‘Winter Storage’).
Never feed your fish when the unit is not in use.
Before First Use
Inappropriate handling of this product during transit may result in damage to
the quartz tube. Please inspect the quartz tube and seal before installation.
See the section “Maintenance” for details on how to access the quartz tube and
lamp.
Installation
Position – Construct a solid and level platform on which to place the
EasyClear™. The platform should be greater than 300 mm (12”) below the water
level. For depths between 300mm and 600mm use the fountain stem extension
segments (Fig 1-F), which simply screw together, to allow the fountain to be
above the water level. For general installation see Fig 4-A/B. When using the
EasyClear for a waterfall the entire unit should be submersed.
Connection – Place the unit next to the pond and route the cable back to the
mains supply. Ensure that you allow for enough cable for positioning the
product in the desired location in the pond.
Accessory Assembly
- Bell Fountain (Fig 1)
- Locate the Bell Support (B) to the Bell Main Body (C) and push fully home.
- Position the Bell (D) to the Body Assembly and press into the central location.
- 2 and 3 tier fountain display assembly (Fig 1-I).
- The plastic discs (Fig 1-E) that create the 2 and 3 tier water displays simply snap onto the fountain stem. Push the fountain stem into the fountain stem extension segment and screw onto the fountain outlet (Fig 1-A).
Fountain Only Operation
- (Fig 4-A for general installation guide)
- Please note: The product has a water by-pass to control water flow rates which means a quantity of water will always come out of the product just below the flow control. This is normal in operation.
- Position the unit in the pond. The fountain angle can be adjusted to be vertical using the ball joint (Fig 2-A).
- The tightness of the ball joint can be adjusted (Fig 2-J).
- If required, the 2-Tier Fountainhead can be used to achieve an alternative and higher display pattern than the 3-Tier.
- The fountain height can be adjusted to suit your needs by rotating the Fountain Flow Adjuster (Fig 3-K).
- The Bell Fountain creates a decorative waterbell. The size of the bell can be adjusted to suit your needs by rotating the Fountain Flow Adjuster (Fig 3-K).
Waterfall Only Operation
- (Fig 4-B for general installation guide)
- Position the pump as previously described.
- Attach a suitable length (3m maximum) of 25 mm (1”) hose to the waterfall hose tail (Fig 1-G) and secure with a suitable hose clip and position the outlet end of the hose in the desired position.
- Screw the waterfall hose tail to the fountain outlet of the EasyClear™ (Fig 1-A) and adjust the flow using the fountain flow adjuster, (Fig 3-K), to suit your needs.
- Note : The maximum recommended waterfall height above pond level is 0.5m (Fig 4-B).
UVC Operation
- The UVC will automatically switch on once the unit has been connected to the electricity supply if the bayonet tube is correctly locked in place.
- The UVC lamp can be checked for operation by looking for a bluish glow from ball joint outlet (Fig 1-A). Please note that this may only become visible in low light conditions.
- See Maintenance section for Lamp replacement.
Maintenance
- The Hozelock Cyprio EasyClear™ has been designed to allow fast and easy maintenance. As with all pond equipment, occasionally it will become necessary to clean or replace parts.
- WARNING: Disconnect this product from the electricity supply and refer to the section “Safety & Electrical Connections” before attempting any maintenance.
Fountain Head (Fig 1-I)
Follow the below procedure if the fountain head is blocked:
- Place a coin or similar in the slot and gently lever off the fountain head.
- Rinse in clean water and reassemble. Foam
Follow the below procedure if flow appears reduced:
- Release the Foam Cover by pushing the two buttons (Fig 5-M) and lift the cover (Fig 6-N).
- Remove the Foam (Fig 7-O). Note:- If the unit is out of the pond for more then 20 minutes the biological filter action may stop working. Rinse thoroughly in pond water (do not use tap water).
- The Foam Cover and Base should also be rinsed in pond water (do not use tap water).
- It may also be necessary to clean out the biomedia and stones (Fig 7-P) if these have become clogged. If this is necessary, the biomedia and stones should be rinsed in pond water only.
- Reassemble the Filter.
Quartz Tube
Follow the below procedure if your pond remains green:
- Remove the bayonet locking screw (Fig 8-Q), twist and lift the bayonet tube (Fig 8-R).
- Clean the Quartz Tube. Take extra care when handling the Quartz tube. In hard water areas, the quartz tube may become covered in limescale, which will reduce efficiency. Clean the tube with a soft cloth and a gentle de-scaler (such as vinegar and water), rinse in water before refitting.
- Reassemble the bayonet tube and screw and restart (Fig 8-S).
Warning! Ensure that the quartz tube is not damaged before refitting.
Lamp Replacement
Follow the below procedure if the lamp needs replacing or does not illuminate:
Change the lamp at the start of the new season. Even though the lamp still
glows it may not be giving out any useful UV radiation. How well the
EasyClear™ performs is related to the strength of the UV radiation produced.
This will slowly decline from the day your lamp is switched on. The UVC lamp
has an effective life of 12 months. You need to change the lamp when there is
a significant reduction in water clarity. Make sure this is due to an expired
lamp and not a badly maintained filter or a dirty/limescaled quartz sleeve.
Both can greatly reduce UV transmission into the water.
- Remove the bayonet locking screw (Fig 8-Q), twist and lift the bayonet tube (Fig 8-R).
- Unscrew the quartz tube locking collar (Fig 9-T-i). Gently hold the quartz tube (Fig 9-T-ii), lift up and remove together with its o-rings (Fig 9-T-iii) and locking collar.
- Remove the old lamp by gently pulling it from its holder (Fig 9-U). Dispose of the old lamp according to local regulations and fit the new lamp.
- Slide the quartz tube down over the lamp. Ensure that the two o-rings at the base of the quartz tube are clean and free from debris.
- Slide the locking collar down over the quartz tube and screw down. You should screw down until the stop of the locking collar hits the stop of the housing so that the collar cannot be screwed down any more.
- Reassemble the bayonet tube and screw and
restart (Fig 8-S).
WARNING! ENSURE THAT THE QUARTZ TUBE IS ASSEMBLED CORRECTLY SO THAT IT PROVIDES A COMPLETELY WATERTIGHT SEAL.
Check the condition of the two o-rings on the Quartz Tube Assembly (Fig 9-T-iii). If these are damaged in any way or you cannot guarantee a water tight seal, contact Hozelock Consumer Services.
Biological Filter
Normally, there is no need to remove the biomedia as any cleaning may kill the
colonies of bacteria that make toxic waste harmless. However if the biomedia
becomes heavily clogged and does require cleaning follow this procedure.
- Remove the foam.
- The bag of Kaldnes Biomedia (Fig 7-P) can then be removed for cleaning.
- Wash in pond water.
- Reassemble the filter and restart.
Rotor Cleaning/Replacement
If the no water is being pumped or flow is reduced, remove the quartz tube and
lamp as described above, then follow the below procedure.
- Release the Foam Cover by pushing the two buttons (Fig 5-M) and lift the cover (Fig 6-N).
- Remove the foam (Fig 7-O), biomedia (Fig 7-P) and stone bag.
- Turn the unit over and remove the 4 fixing screws (Fig 10-V) and lift the base clear.
- Remove the 2 fixing screws (Fig 10-W) and lift the Pump Assembly clear.
- Twist the Pump Chamber anticlockwise (Fig 10-X) and lift clear. The rotor can now be pulled out forcleaning or replacement ( Fig 10-Y). Important! Take extra care so as to not drop any of the small components. See Fig 10A for assembly of the rotor.
- Reassemble the pump and 2 off fixing screws (Fig 10-W).
- Reroute the cable (Fig 10-Z).
- Reassemble the filter, and restart.
All Year Pump Care
- A quick daily check should be carried out to ensure that the pump is performing satisfactorily.
- Once a week- Remove the outer casing and Fountain Head in accordance with the general maintenance notes.
- Depending on pond water conditions, cleaning may be required more frequently.
- Once a year- Completely disassemble the unit including the Rotor Assembly as described in the general maintenance notes, and wash all components in clean, freshwater.
- Replace worn or broken parts.
Winter Storage
- When not in use, the unit should be removed, thoroughly washed and cleaned, dried and stored in a dry frost protected area. Always store the unit with the foam and foam cover off to ensure adequate ventilation and drying.
Contact/Spare Parts
For product advice and spares please contact Hozelock Cyprio Consumer
Services on 0121 313 1122 or visit www.hozelock.com
Fish Stocking and Density
Under normal conditions, the EasyClear™ 3000 or 4500 will support up to
72cm of fish. Introduce fish slowly over the first few weeks, up to 20% of the
maximum recommended level, increasing to 50% after six months. The balance
will allow for fish growth.
Hozelock Cyprio Clearwater Guarantee
WE GUARANTEE YOU CLEAR WATER OR YOUR MONEY BACK.
NOTE: IN SOME CASES IT CAN TAKE UP TO 6-8 WEEKS FOR YOUR WATER TO BECOME
CLEAR.
This guarantee runs for 12 months after purchase, provided that
- You have followed the installation and operating instructions.
- You are using equipment of the correct size and stocking level.
- You consult our Helpline (0121 313 1122) early enough for any problems to be put right.
- The product has been returned undamaged.
- A refund can only be authorised by Hozelock Cyprio and is made only at the place of purchase to the value of the purchase price of the EasyClear™ only. A Proof of Purchase will be required.
- Please note that the Clearwater Guarantee does not cover loss of water clarity when blanketweed, as opposed to greenwater algae, is the cause.
3 Year Product Guarantee
- If this unit, excluding the Rotor Assembly, Filter Foam & UV Lamp becomes unserviceable within 3 years of the date of purchase it will be repaired or replaced at our option free of charge, unless in our opinion it has been damaged or misused. Liability is not accepted for damage due to accident, improper installation or use.
- Liability is limited to replacement of a faulty unit. This guarantee is not transferable. It does not affect your statutory rights.
- To obtain the benefits of the guarantee, firstly contact Hozelock Cyprio Consumer Services who may request that the filter is sent along with proof of purchase directly to the address provided.
- DAMAGE CAUSED BY RUNNING THE EasyClear™ OUT OF WATER OR BY FROST INVALIDATES THE GUARANTEE.
Fault Finding
Please read the safety sections of these instructions before carrying out any
remedial action on the EasyClearTM! It may also be necessary to refer to the
maintenance section of these instructions.
LOW FLOW FROM PUMP
- The foams may be blocked and require cleaning
- Ensure the outer cage is clean.
- Clear any blockages and adjust the flow controls.
- Check white flap inside pump chamber moves freely.
- Ensure rotor is clean and moves freely.
POOR FOUNTAIN DISPLAY
- a – As above
- b – Clean the Fountain Head.
UV LAMP NOT WORKING
- Check power supply is on.
- Check fuse, RCD and wiring.
- Replace the lamp.
- The Overload Protection may have operated – see
- Overload Protection section.
PUMP NOT WORKING
-
Check power supply is on.
-
Check fuse, RCD and wiring.
-
Check the rotor is not blocked.
-
The Overload Protection may have operated – see
Overload Protection section. -
Ensure the outer cage is clean.
-
Check for water ingress in lamp area.
Technical Information
Part Number | 1760 | 1762 |
---|---|---|
Model | 3000 | 4500 |
Volts | 230V 50Hz | 230V 50Hz |
UVC Power (W) | 5 | 7 |
Total Power (W) | 25 | 28 |
Maximum Pond size without Fish | 3000 ltr (660 gal) | 4500ltr (990 gal) |
Maximum Pond size with Fish | 2000 ltr (440 gal) | 3000 ltr (660 gal) |
Max Flow, Qmax, (lph) | 1260 lph (276 gph) | 1260 lph (276 gph) |
Max Head, Hmax, (m) | 1m | 1m |
IP Rating | IPX8 | IPX8 |
Max Water Temperature Tmax, (°C) | 35°C | 35°C |
- Measured under controlled conditions
Do not dispose of electrical appliances as unsorted municipal waste, use separate collection facilities. Contact your local government for information regarding the collection systems available. If electrical appliances are disposed of in landfills or dumps, hazardous substances can leak into the groundwater and get into the food chain, damaging your health and well-being. In the EU, when replacing old appliances with new ones, the retailer is legally obligated to take back your old appliance for disposal at least free of charge.
EASYCLEAR
6000/7500/9000
- Hozelock Ltd.
- Midpoint Park, Birmingham, B76 1AB. England
- Tel: +44 (0) 121 313 1122
- www.hozelock.com
- 33904-000
Thank you for choosing a Hozelock quality product, you can be assured of many years of reliable service from this product.
INSTALLATION & OPERATING INSTRUCTIONS
FAILURE TO OBSERVE THE FOLLOWING NOTICES MAY RESULT IN INJURY, PRODUCT DAMAGE
OR LOSS OF FISH.
KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE.
The Hozelock Cyprio EasyClear™ Fountain or Waterfall pump is designed for
submersible use in outdoor ponds. It is an integrated unit that provides
Mechanical & Biological Filtration with an Ultra Violet Clarifier and a
Fountain or Waterfall.
Attention: UV Caution
- This appliance contains a UV-C emitter. Unintended use of the appliance or damage to the housing may result in the escape of dangerous UV-C radiation. UV-C radiation may, even in little doses, cause harm to the eyes and skin. The lamp is fitted with an interlock that will turn the lamp off when the bayonet is removed (fig 8-S).
- When switched on, the lamp can be checked for operation in dark conditions, by looking for a bluish glow from the Fountain outlet (Fig 1-A). Do not run the product dry.
- Warning: Do not attempt to operate the UV-C emitter when it is removed from the appliance housing.
- Warning: The appliance must be disconnected from the supply before replacing the UV-C emitter.
Important
- This appliance must only be used by or under the supervision of a responsible adult who is capable of using the appliance in a safe way and who understands the hazards involved.
- Use and store this appliance out of reach of children and persons with reduced physical, sensory, or mental capabilities.
Warning:
Safety & Electrical Connections
-
WARNING: ALWAYS UNPLUG OR DISCONNECT ALL APPLIANCES IN THE POND FROM THE ELECTRICITY SUPPLY BEFORE PUTTING YOUR HANDS IN THE WATER WHILST EQUIPMENT IS BEING INSTALLED, REPAIRED, CARRYING OUT ANY
MAINTENANCE OR BEING HANDLED IN ANY WAY. -
This filter has been designed for the use with garden ponds only. Do not use this filter for any other use (i.e. do not use this filter in swimming pools, etc). Using the product for any other application may result in injury or product damage. This pump must not be used when people are in the water.
-
Appliances that are obviously damaged must
not be operated. -
The clear tube inside the unit is made from quartz glass and care should be taken during installation and maintenance. We recommend the use of eye protection and suitable gloves.
-
Do not remove and operate the pump unit from its outer housing. Using the unit without its outer housing may invalidate your warranty.
-
Important: This product is supplied with 10m of 3-core electric cable . It is designed to be permanently wired to the mains supply. For connection to the mains supply use only 3-core cable (ref HO5 RN-F). This has a minimum copper cross-section of 0.75mm2 with Polycloroprene-Rubber insulation.
The termination to the mains supply should be:- Permanent.
- Inside a dry weatherproof enclosure.
- Through a double pole switched fused spur to BS 3676.
- Fitted with a 3 or 5 amp fuse.
-
If an extension cable is required, this should be connected to the end of the unit cable using
a weatherproof connector. The joint must be positioned in a suitable weatherproof housing. The extension cable should be of 3 core 0.75mm2 Polychloroprene rubber insulated cable (ref: HO5 RN-F) and permanently wired to the mains supply as described above in 1.6. -
WARNING: This appliance MUST be earthed and it is essential that the connections are made using the following code:
- BROWN – live
- BLUE – neutral
- GREEN/YELLOW – earth.
-
Exposed cable runs should be sensibly positioned and protected by armoured conduit, especially if there is a risk of contact with gardening equipment such as forks and lawnmowers, or children and domestic animals.
-
Do not operate this product if the mains supply cable has become damaged in any way. The supply cable is permanently connected and sealed to the pump and cannot be replaced. If the cable is damaged, the unit should be disposed of according to local regulations.
-
A 30mA maximum Residual Current Device (RCD) MUST be fitted to the mains supply.
-
Permanent installations to the mains supply (hard wiring), must conform to the national and local wiring regulations. If in any doubt about wiring to the mains supply, consult a qualified electrician or local electricity authority.
-
Do not use the supply cable to lift the unit, as this may cause damage. We recommend fitting a lifting cord to the hook feature on the base, when the filter is installed in deep water. (Fig 1-H). If the product needs to be moved, the product should be switched off and lifted out of the water using this cord.
-
Do not switch the pump on out of water! The water level should be above the UVC indicator at the ball joint (Fig 4A-L).
-
Do not operate or leave the unit in freezing conditions. (See the section, “Winter Storage”).
-
This product is not suitable for water temperatures above 35ºC or below 0ºC.
-
Only use accessories which have been designed for use with this product. The use of any other accessories or spares may invalidate your guarantee.
Installing this product in the garden is classed as ‘notifiable’ in the Regulations for England and Wales. The Regulations require you to tell your local authority building control department that you intend to install this product before installation. Your local authority will let you know how you can get your installation approved.
Overload Protection
- To help ensure your EasyClear’s long life and to prevent damage, it is fitted with automatic thermal overload protection. This switches the pump or UV lamp off if either overheats. If this occurs, switch off the power at the mains supply to the unit. If it is the pump that has activated the Overload Protection, check for the cause (it is usually debris blocking the inlet of the pump or obstructing the impeller). Remove the obstruction and wait 15 minutes for the unit to cool down. Then switch it on again.
- If it is the UV lamp that is activating the overload protection (pump is still running but UV lamp keeps going out after running for a short time), please contact Hozelock Consumer
- Services Helpline on +44 (0)121 313 1122.
- Remember: The lamp is fitted with an interlock that will turn the lamp off when the bayonet is removed (fig 8-S), so you can only see if the lamp is working in dark conditions, by looking for a bluish glow from the Fountain outlet (Fig 1-A) with the bayonet tube locked in position.
- NOTE: YOU MUST SWITCH OFF THE MAINS SUPPLY BEFORE THE UNIT WILL RESET.
- CAUTION: To avoid a safety hazard due to inadvertent resetting of the thermal overload protection, this product must not be used with an external switching device, such as a timer, or connected to a circuit that is regularly switched on and off by the electricity supply.
Periods of Operation
Keep the filter working 24 hours a day. Ideally it should run all year
round, but at least throughout the fish-feeding season, (i.e. until the water
temperature falls below 10°C and the fish stop feeding). In winter, operating
the unit will maintain a basic level of useful bacteria in the Biological
Filter, and will help prevent the pond icing over. However, the unit must not
be allowed to freeze. If you switch the unit off for winter, wash the unit
thoroughly before resuming filtration in the spring (see ‘Winter Storage’).
Never feed your fish when the unit is not in use.
Before First Use
Inappropriate handling of this product during transit may result in damage to
the quartz tube. Please inspect the quartz tube and seal before installation.
See the section “Maintenance” for details on how to access the quartz tube and
lamp.
Installation
Position – Construct a solid and level platform on which to place the
EasyClear™. The platform should be greater than 300 mm (12”) below the water
level. For depths between 300mm and 600mm use the fountain stem extension
segments (Fig 1-F), which simply screw together, to allow the fountain to be
above the water level. For general installation see Fig 4-A/B. When using the
EasyClear for a waterfall the entire unit should be submersed.
Connection – Place the unit next to the pond and route the cable back to the
mains supply. Ensure that you allow for enough cable for positioning the
product in the desired location in the pond.
Accessory Assembly
- Bell Fountain (Fig 1).
- Locate the Bell Support (B) to the Bell Main Body (C) and push fully home.
- Position the Bell (D) to the Body Assembly and press into the central location. Insert this into the Fountain Flow Adjuster (Fig 1-H).
- 2 and 3 tier fountain display assembly (Fig 1-G).
- The plastic discs (Fig 1-E) that create the 2 and 3 tier water displays simply snap onto the fountain stem. Push the fountain stem into the fountain stem extension segment and screw onto the Fountain Flow Adjuster (Fig 1-H).
Fountain Only Operation
- Please note: It is not possible to completely close off the waterfall outlet (Fig 1-I). This is to allow water to always bypass in to the pond even if the fountain head becomes blocked ensuring clear water. If the pond water is not clearing sufficiently it may be necessary to allow more water to bypass in to the pond by opening the waterfall outlet.
- The 2 and 3 tier fountainheads simply snap onto the fountain stem. The fountain angle can be adjusted to be vertical using the ball joint (Fig 2-L). The tightness of the ball joint can be adjusted (Fig 2-M) if required, the 2- Tier Fountainhead can be used to achieve an alternative and higher display pattern than the 3-Tier.
- The fountain height can be adjusted to suit your needs by rotating the Fountain Flow Adjuster (Fig 3B-N). Turn the Waterfall Adjuster (Fig 3A-O) until closed to obtain the maximum fountain height.
- The Bell Fountain creates a decorative ‘water bell’. The size of the bell can be adjusted to suit your needs by rotating the Fountain Flow Adjuster (Fig 3B-N).
- Install and position the pump as previously described and switch on.
Fountain and Waterfall Operation
- Attach a suitable length (3m maximum) of 25 mm (1”) hose to the hose tail on the Waterfall Adjuster (Fig 3A-Q) and secure with a suitable hose clip and position the outlet end of the hose in the desired position.
- Screw the Waterfall Adjuster onto the waterfall outlet on the front of the EasyClear™ (Fig 3A-Q).
- Once the pump is operating the flow of the waterfall and the height of the fountain can be independently adjusted using the Fountain Adjuster (Fig 3B-N) and Waterfall Adjuster (Fig 3A-O).
- Install and position the pump as previously described and switch on.
Waterfall Only Operation
- (Fig 4 for general installation guide)
- Screw the blanking plug onto the fountain outlet (Fig 3A-P).
- Attach a suitable length (3m maximum) of 25 mm (1”) hose to the hose tail on the Waterfall Adjuster (Fig 3A-O) and secure with a suitable hose clip and position the outlet end of the hose in the desired position.
- Screw the Waterfall Adjuster onto the waterfall outlet on the front of the EasyClear™ (Fig 3A-Q).
- Adjust the flow using the Waterfall Adjuster, (Fig 3A-O), to suit your needs.
- Install and position the pump as previously described and switch on.
UVC Operation
- The UVC will automatically switch on once the unit has been connected to the electricity supply if the bayonet tube is correctly locked in place.
- The UVC lamp can be checked for operation by looking for a bluish glow from ball joint outlet (Fig 1-A). Please note that this may only become visible in low light conditions.
- See Maintenance section for Lamp replacement.
Maintenance
The Hozelock Cyprio EasyClear™ has been designed to allow fast and easy
maintenance. As with all pond equipment, occasionally it will become necessary
to clean or replace parts.
WARNING: Disconnect this product from the electricity supply and refer to
the section “Safety & Electrical Connections” before attempting any
maintenance.
Fountain Head (Fig 1-E)
Follow the below procedure if the fountain head is blocked:
-
Place a coin or similar in the slot and gently lever
off the fountain head. -
Rinse in clean water and reassemble.
Foam
Follow the below procedure if flow appears reduced:
-
Release the Foam Cover by pushing the two buttons (Fig 5-R) and lift the cover (Fig 6-S).
-
Remove the Foam (Fig 7-T). Note:- If the unit is out of the pond for more then 20 minutes the biological filter action may stop working. Rinse thoroughly in pond water (do not use tap water).
-
The Foam Cover and Base should also be rinsed in
pond water (do not use tap water). -
It may also be necessary to clean out the biomedia and stones (Fig 7-U) if these have become clogged. If this is necessary, the biomedia and stones should be rinsed in pond water only.
-
Reassemble the Filter.
Quartz Tube
Follow the below procedure if your pond remains green:
- Remove the bayonet locking screw (Fig 8-V), twis and lift the bayonet tube (Fig 8-W).
- Clean the Quartz Tube. Take extra care when handling the Quartz tube. In hard water areas, the quartz tube may become covered in limescale, which will reduce efficiency. Clean the tube with a soft cloth and a gentle de-scaler (such as vinegar and water), rinse in water before refitting.
Reassemble the bayonet tube and screw and
restart (Fig 8-X).
Warning! Ensure that the quartz tube is not damaged before refitting.
Lamp Replacement
Follow the below procedure if the lamp needs replacing or does not illuminate:
Change the lamp at the start of the new season. Even though the lamp still
glows it may not be giving out any useful UV radiation. How well the
EasyClear™ performs is related to the strength of the UV radiation produced.
This will slowly decline from the day your lamp is switched on. The UVC lamp
has an effective life of 12 months. You need to change the lamp when there is
a significant reduction in water clarity. Make sure this is due to an expired
lamp and not a badly maintained filter or a dirty/limescaled quartz sleeve.
Both can greatly reduce UV transmission into the water.
- Remove the bayonet locking screw (Fig 8-V), twist and lift the bayonet tube (Fig 8-W).
- Unscrew the quartz tube locking collar (Fig 9-Y-i). Gently hold the quartz tube (Fig 9-Y-ii), lift up and remove together with its o-rings (Fig 9-Y-iii) and locking collar.
- Remove the old lamp by gently pulling it from its holder (Fig 9-Z). Dispose of the old lamp according to local regulations and fit the new lamp.
- Slide the quartz tube down over the lamp. Ensure that the two o-rings at the base of the quartz tube are clean and free from debris.
- Slide the locking collar down over the quartz tube and screw down. You should screw down until the stop of the locking collar hits the stop of the housing so that the collar cannot be screwed down any more.
- Reassemble the bayonet tube and screw and restart (Fig 8-X).
Warning! Ensure that the quartz tube is assembled correctly so that it provides a completely watertight seal.
Check the condition of the two o-rings on the Quartz Tube Assembly (Fig 9-Y-iii). If these are damaged in any way or you cannot guarantee a water tight seal, contact Hozelock Consumer Services.
Biological Filter
Normally, there is no need to remove the biomedia as any cleaning may kill the
colonies of bacteria that make toxic waste harmless. However if the biomedia
becomes heavily clogged and does require cleaning follow this procedure.
- Remove the foam.
- The bag of Kaldnes Biomedia (Fig 7-U) can then be removed for cleaning.
- Wash in pond water.
- Reassemble the filter and restart.
Rotor Cleaning/Replacement
If the no water is being pumped or flow is reduced, remove the quartz tube and
lamp as described above, then follow the below procedure.
-
Release the Foam Cover by pushing the two buttons (Fig 5-R) and lift the cover (Fig 6-S).
-
Remove the foam (Fig 7-T), biomedia (Fig 7-U) and stone bag.
-
Turn the unit over and remove the 4 fixing screws (Fig 10-AA) and lift the base clear.
-
Remove the 2 fixing screws (Fig 10-BB) and lift the Pump Assembly clear.
-
Twist the Pump Chamber anticlockwise (Fig 10-CC) and lift clear. The rotor can now be pulled out for cleaning or replacement ( Fig 10-DD).
Important! Take extra care so as to not drop any of the small components.
See Fig EasyClearTM 10A for assembly of the EasyClearTM 6000 and EasyClearTM 7500 rotors and Fig 10B for assembly of the EasyClear 9000 rotor. -
Reassemble the pump and 2 off fixing screws (Fig 10-BB).
-
Reroute the cable (Fig 10-EE).
-
Reassemble the filter, and restart.
All Year Pump Care
- A quick daily check should be carried out to ensure that the pump is performing satisfactorily.
- Once a week- Remove the outer casing and Fountain Head in accordance with the general maintenance notes.
- Depending on pond water conditions, cleaning may be required more frequently.
- Once a year- Completely disassemble the unit including the Rotor Assembly as described in the general maintenance notes, and wash all components in clean, freshwater.
- Replace worn or broken parts.
Winter Storage
When not in use, the unit should be removed, thoroughly washed and cleaned, dried and stored in a dry frost protected area. Always store the unit with the foam and foam cover off to ensure adequate ventilation and drying.
Contact/Spare Parts
For product advice and spares please contact Hozelock Cyprio Consumer
Services on 0121 313 1122 or visit www.hozelock.com
Fish Stocking and Density
Under normal conditions, the EasyClear™ will support up to 1.44m
(EasyClear™ 6000 & EasyClear™ 7500) or 2.16m (EasyClear™ 9000) of fish.
Introduce fish slowly over the first few weeks, up to 20% of the maximum
recommended level, increasing to 50% after six months. The balance will allow
for fish growth.
Hozelock Cyprio Clearwater Guarantee
WE GUARANTEE YOU CLEAR WATER OR YOUR MONEY BACK.
NOTE: IN SOME CASES IT CAN TAKE UP TO 6-8 WEEKS FOR YOUR WATER TO BECOME
CLEAR.
This guarantee runs for 12 months after purchase, provided that
- You have followed the installation and operating instructions.
- You are using equipment of the correct size and stocking level.
- You consult our Helpline (0121 313 1122) early enough for any problems to be put right.
- The product has been returned undamaged.
A refund can only be authorised by Hozelock Cyprio and is made only at the place of purchase to the value of the purchase price of the EasyClear™ only. A Proof of Purchase will be required.Please note that the Clearwater Guarantee does not cover loss of water clarity when blanketweed, as opposed to greenwater algae, is the cause.
3 Year Product Guarantee
- If this unit, excluding the Rotor Assembly, Filter Foam & UV Lamp becomes unserviceable within 3 years of the date of purchase it will be repaired or replaced at our option free of charge, unless in our opinion it has been damaged or misused. Liability is not accepted for damage due to accident, improper installation or use.
- Liability is limited to replacement of a faulty unit. This guarantee is not transferable. It does not affect your statutory rights.
- To obtain the benefits of the guarantee, firstly contact Hozelock Cyprio Consumer Services who may request that the filter is sent along with proof of purchase directly to the address provided.
- DAMAGE CAUSED BY RUNNING THE EasyClear™ OUT OF WATER OR BY FROST INVALIDATES THE GUARANTEE.
Fault Finding
- Please read the safety sections of these instructions before carrying out any remedial action on the EasyClearTM! It may also be necessary to refer to the maintenance section of these instructions.
LOW FLOW FROM PUMP
- The foams may be blocked and require cleaning
- Ensure the outer cage is clean.
- Clear any blockages and adjust the flow controls.
- Check white flap inside pump chamber moves freely.
- Ensure rotor is clean and moves freely.
POOR FOUNTAIN DISPLAY
- As above
- Clean the Fountain Head.
UV LAMP NOT WORKING
- Check power supply is on.
- Check fuse, RCD and wiring.
- Replace the lamp.
- The Overload Protection may have operated – see
Overload Protection section. PUMP NOT WORKING
-
Check power supply is on.
-
Check fuse, RCD and wiring.
-
Check the rotor is not blocked.
-
The Overload Protection may have operated – see
Overload Protection section. -
Ensure the outer cage is clean.
-
Check for water ingress in lamp area.
Technical Information
Part Number | 1764 | 1766 | 1768 |
---|---|---|---|
Model | 6000 | 7500 | 9000 |
Volts | 230V 50Hz | 230V 50Hz | 230V 50Hz |
UVC Power (W) | 9 | 11 | 13 |
Total Power (W) | 40 | 43 | 55 |
Maximum Pond size without Fish | 6000 ltr (1319 gal) | 7500 ltr (1648 gal) |
9000ltr (1978 gal)
Maximum Pond size with Fish| 4000 ltr (879 gal)| 5000 ltr (1099 gal)| 6000 ltr
(1319 gal)
Max Flow, Qmax, (lph)| 1700 lph (374 gph)| 1700 lph (374 gph)| 2850 lph (627
gph)
Max Head, Hmax, (m)| 2m| 2m| 2.3m
IP Rating| IPX8| IPX8| IPX8
Max Water Temperature Tmax, (°C)| 35°C| 35°C| 35°C
Measured under controlled conditions
Do not dispose of electrical appliances as unsorted municipal waste, use separate collection facilities. Contact your local government for information regarding the collection systems available. If electrical appliances are disposed of in landfills or dumps, hazardous substances can leak into the groundwater and get into the food chain, damaging your health and well-being. In the EU, when replacing old appliances with new ones, the retailer is legally obligated to take back your old appliance for disposal at least free of charge.
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>