GENMAX GM7500iAED Dual Fuel Inverter Generator
Specifications
- Brand: Genmax
- Model: GM7500iAED
- Type: Inverter Generator
- Power Output: 7500W (Starting) / 6000W (Running)
- Fuel Type: Dual Fuel (Gasoline/LPG)
Product Usage Instructions
Unpacking
- Always have assistance when lifting the generator to prevent bodily harm due to its weight.
- Use a box cutter to carefully cut the packing tape on top of the carton.
- Remove the spark plug socket wrench and oil funnel and keep them for later use.
- Cut two sides of the carton to remove the generator.
Description of Fittings
- Spark Plug Socket Wrench: Used for spark plug maintenance, inspection, and installation.
- Dual-Purpose Screwdriver: Phillips and slot blade screwdriver for generator maintenance.
- Funnel: Used for adding oil to the generator.
- Remote Control Key: Used to remotely start and stop the generator.
- LPG Hose: Connects the LPG tank to transmit fuel to the generator.
Adding Oil
Before starting the generator, ensure to add the provided 800ml 10W30 oil using the funnel included in the box.
LPG Hose Connection
- Connect the LPG hose to the gas cylinder joint.
- Ensure the first stage reducing valve is properly attached.
- Check that the LPG hose pressure is at 1psi.
- Make sure the hose length is 1485mm with an inside diameter of 5/8-18UNF.
FAQs
- Q: What should I do if the generator does not start?
- A: Check if there is sufficient oil in the generator and that all connections, including the LPG hose, are secure. Refer to the troubleshooting section in the user manual for further guidance.
- Q: Can I run the generator indoors?
- A: No, it is not safe to operate the generator indoors due to the risk of carbon monoxide poisoning. Always use it outdoors in a well-ventilated area.
R
GENMAX GENERATOR
INVERTER GENERATOR USER’S MANUAL
GM7500iAED
Portable Dual Fuel Generator
7500/6000
6000/5500
WARNING: SAVE THIS MANUAL FOR FUTURE REFERENCE
This manual contains important information regarding safety. Operation,
maintenance and storage of this product. Before use, read carefully and
understand all cautions, warnings, instructions and product labels. Failure to
do so could result in serious personal injury and/or property damage.
DISCLAIMERS: All information, illustrations and specifications in this manual
are based on the latest information available at the time of publishing. The
illustrations used in this manual are intended as representative reference
views only. Moreover, because of our continuous product improvement policy, we
may modify information, illustrations and/or specifications to explain and/or
exemplify a product, service or maintenance improvement. We reserve the right
to make any change at any time without notice. Some images may vary depending
upon which model is shown.
ALL RIGHTS RESERVED: No part of this publication may be reproduced or used in
any form by any means – graphic, electronic or mechanical, including
photocopying, recording, taping or information storage and retrieval systems –
without the written permission of CHONGQING DINKING POWER MACHINERY CO., LTD
This manual contains important instructions for operating this inverter
generator. For your safety and the safety of others, be sure to read this
manual thoroughly before operating the generator. Failure to properly follow
all instructions and precautions can cause you and others to be seriously hurt
or killed.
UNPACKING
Always have assistance when lifting the generator. The generator is heavy;
lifting it could cause bodily harm.
Avoid cutting on or near staples to prevent personal injury.
WHAT COMES IN THE BOX
Spark Plug Socket Wrench (1) Dual-Purpose Screwdriver (1) User Manual (1)
Warranty Information (1) Funnel (1) Remote Control Key (1) LPG Hose (1) 800ml
10W30 Oil(1)
Tools required – box cutter or similar device.
1. Carefully cut the packing tape on top of the carton.
2. Remove socket wrench, and oil funnel and save for later.
3. Carefully cut two sides of the carton to remove the generator.
1
DESCRIPTION OF FITTINGS
Spark Plug Socket Wrench
Dual-Purpose Screwdriver
Funnel
Used in spark plug maintenance, inspection, and installation.
Remote Control Key
Phillips and slot blade screwdriver used for generator maintenance.
800ml 10W30 Oil
It’s used to oil the generator.
Used to remotely start and stop the generator.
Be sure to add oil before starting the generator.
LPG Hose
First Stage Reducing Valve
Inside Diameter 1.312″-5ACME
Gas Cylinder Joint
LPG Hose Pressure 1psi
Hose length 1485 mm
Inside Diameter 5/8″-18UNF
Connect the LPG tank to transmit LPG fuel to the generator.
Note: Actual tools may differ in appearance or design from image shown.
2
LIMITED WARRANTY
1. DURATION : One (1) year from the date of purchase by the original
purchaser ( retail customer ) on products used solely for consumer
applications; if a product is used for business, commercial, or industrial
applications, the warranty per iod will be limited to ninety (90) days from
the date of purchase.
2. WHO GIVES THIS WARRANTY (WARRANTOR):
CHONGQING DINKING POWER MACHINERY CO., LTD
3. WHO RECEIVES THIS WARRANTY(PURCHASER):The original purchaser (other than
for purposes of resale) of the Genmax’s inverter.
4. WHAT PRODUCTS ARE COVERED BY THIS WARRANTY: Any portable generator
supplied or manufactured by Warrantor.
5. WHAT IS COVERED UNDER THIS WARRANTY: Substantial defects on material and
workmanship which occur within the duration of the warranty period.
6. WHAT IS NOT COVERED UNDER THIS WARRANTY:
A. Transportation changes for sending the product to Warrantor or its
authorized service representative for warranty service, or for shipping
repaired or replacement products back to the customer; these charges must be
borne by the customer.
B. Damages caused by abuse, accident, shipping, misuse, overloading,
modification, and the effects of corrosion, erosion and normal wear and tear.
C. Warranty is voided if the customer fails to install, maintain and operate
the product in accordance with the instructions and recommendations set forth
in the owner’s manual(s), or if the product is used as rental equipment.
D. Pre-delivery service, i.e. assembly, oil or lubricants, and adjustment.
E. Items or service that are normally required to maintain the product, i.e.
lubricants and filters.
F. Warrantor will not pay for repairs or adjustments to the product, or for
any costs or labour, performed without Warrantor’s prior authorization.
EXCLUSIONS AND LIMITATIONS : Warrantor makes no other warranty of any kind,
express or implied. Implied warranties, including warranties of
merchantability and of fitness for a particular purpose, are hereby
disclaimed. This warranty service described above is the exclusive remedy
under this warranty; liability for incidental and consequential damages is
excluded to the extent permitted by law.
7. RESPONSIBILITIES OF PURCHASER UNDER THIS WARRANTY:
A. The purchaser must provide dated proof of purchase and must notify
Warrantor within the warranty period.
B. Deliver or ship the serviced generator or component to the nearest
Warrantor’s authorized service representative. Freight costs, if any, must be
borne by the purchaser.
8. HAVE QUESTIONS?
Email: service@genmaxpower.com Phone:
866-960-2920
WARRANTY CARD
Name: ___ Model Number:
Street Address: ___ Serial Number:__
City, State, ZIP:____ Date Purchased:
Country: __ Purchased From:____
Phone Number: ___
R
E-Mail: ___
SAFETY WARNING
Personal and property safeties of you and others are very vital. Please read
the Safety Warning in the User’s Manual and the decals of the generator set
carefully.The Safety Warning can alert you to those potential hazards that
could harm you and others. In front of each Safety Warning, there is one of
four words “DANGER” “WARNING”, “ATTENTION”, and “CAREFUL”. Details are as
follows:
Failure to follow the instruction will result in being in peril of your life or extremely serious injury.
Failure to follow the instruction will result in being in peril of your life or very serious injury.
Failure to follow the instruction will result in minor injury.
Failure to follow the instruction will result in the damage to your generator set and other properties.
CO TECHNICAL WARNING
CO DETECT technology monitors the accumulation of carbon monoxide (CO), a
poisonous gas produced by engine exhaust when the generator is running. If CO
Sensor detects unsafe elevated levels of CO gas, it automatically shuts off
the engine. CO Sensor is not a substitute for an indoor carbon monoxide alarm
or for safe operation. DO NOT allow engine exhaust fumes to enter a confined
area through windows, doors, vents or other openings. Generators must ALWAYS
be used outdoors, far away from occupied buildings with engine exhaust pointed
away from people and buildings. Meets the requirements of ANSI/PGMA G300-2018.
NEUTRAL FLOATING
For portable generators where the neutral is floating, the operator’s manual
shall include the following wording or equivalent: The portable generator
stator winding is isolated from the frame and from the AC receptacle ground
pin; and Electrical devices that require a connection between one conductor
pin and the grounded receptacle pin may not function properly.
5
SAFETY INSTRUCTIONS
Before operating the generator, it will help you avoid accidents to read and understand the Manual and familiarize yourself with the safe operation procedures of the generator.
Please do not use indoors
Please do not use in humid environment
Do not directly connect to the household power supply system
Please do not smoke when refueling
Please do not spill when refueling
Please shut down the generator before refueling
6
SAFETY INSTRUCTIONS
SAFETY LABELS AND DECALS
6
77/25
6
7
NAMES OF COMPONENTS
1
10
3
11
5
4 6
2
7
8
9
Fuel Tank Cap: Open the fuel tank cap and fill with proper amount of gasoline. Recoil Handle: Pull to start the engine. Telescopic Rod Left Outer Cover: Unscrew the bolt, remove the outer cover, connect the battery wire, maintain the air filter and replace the spark plug. Control Panel: Contains the reset breaker, outlets and warning lights. Engine Cooling Vents: Helps move airflow in unit
to regulate engine temperatures. Right Outer Cover: Unscrew the bolt, remove the outer cover, refuel or change the oil. Muffler: Avoid contact until the engine is cooled down. The spark arrestor prevents sparks from exiting the muffler. It must be removed for servicing. Wheel LPG Inlet: Connects the LPG inlet to the LPG hose/regulator. Fuel Source: GAS/LPG valve that changes the fuel into the engine.
8
CONTROL FUNCTIONS
6
7
8
2
5
1
START/STOP
11 12
4
10
14
3
9
13
CONTROL PANEL FEATURES GM7500iAED
Main Switch: Manage battery power and shutdown.
Low Idle: When turned to the ON position, the engine will sense the load
needed and run at a slower RPM to save fuel.
START/STOP Switch: Press this button, the engine can start and stop.
Reset: If the inverter is overloaded, the reset breaker will trip. The engine
will continue to run, but there will be no output from the inverter. Unplug
the devices and reduce the load. Push in the reset breaker to reset it.
USB Duplex: 5V DC, type-A and type-C connectors.
120V AC 20A 5-20R Outlet: The outlet is capable of carrying a maximum of 20
amps.
120V AC 30A TT-30R Outlet: The outlet is capable of carrying a maximum of 30
amps.
120/240V AC 50A 14-50R Outlet: The outlet is capable of carrying a maximum of
50 amps.
Battery Charging Port: Charge the generator battery.
Circuit Breaker: If the inverter is overloaded, the reset breaker will trip to
block current.
CO Alarm: Flashing red light: dangerous levels of carbon monoxide gas have
built up leave immediately until area has aired out. Move generator to
wellventilated area before operation. Flashing yellow light: carbon monoxide
sensor malfunction. Sensor needs service.
Ground Terminal: The ground terminal is used to externally ground the
inverter.
Parallel Connectors: To increase AC power output, the connector sockets are
used to connect the two same type generators with special parallel kit
GM9000PK sold by GENMAX. The connector sockets is only used to connect two
inverter generators. They can not used for AC power output. The special
paralleling kit GM9000PK shall be purchased separately, and they shall be
approved by certification body.
Voltage Switch: Switch between 120V and 240V voltage as required.
9
CONTROL FUNCTIONS
OUTPUT DESCRIPTION OF THE AC SOCKET When the voltage selector switch is set to
120V ONLY
The voltage selector switch is set to 120V ONLY.
A
Output voltage can only be 120V and current 50A. Single socket output 120V(Voltage)×50A(Current)=6000W(Output Power)
120V
B
120V
ATTENTION: The total power output of the socket must not exceed the rated
power of the generator.
Single socket output Output voltage 120V current 20A.
120V(Voltage)×20A(Current)=2400W(Output Power)
When the voltage selector switch is set to 120/240V (Suitable for parallel)
The voltage selector switch is set to 120/240V. The voltage is 120/240V and
two generators can be connected in parallel.
A
240V
120V
B
120V
The output voltage is 120/240V, and the current is only 25A without parallel connection. & 120V socket hole: 120V(Voltage)×25A(Current)=3000W(Output Power) 240V socket hole: 240V(Voltage)×25A(Current)=6000W(Output Power)
Single socket output
When two generators are connected in parallel, the socket can output 240V voltage at 50A current: 240V(Voltage)×50A(Current)=12000W(Output Power)
A load
OK
ATTENTION: can output at the same time, but
120V
B load
C load
A load
the total power output of the socket can not exceed the rated power of the generator, can not be connected to the same load.
ATTENTION: The total power output of the socket must not exceed the rated power of the generator.
Single socket output Output voltage 120V current 20A.
120V(Voltage)×20A(Current)=2400W(Output Power)
10
CONTROL FUNCTIONS
DIGITAL DISPLAY CENTER
AUTOMATIC ROTATING DIGITAL DISPLAY(scroll once every 5 s)
10
OVERLOAD: Red light means the machine overload. OUTPUT: Indicates the inverter
is ready to be used.
LOW OIL: Red light means the amount of oil is too low. POWER OUTPUT: Output
power percentage display.
GASOLINE FUEL METER: Gasoline fuel level display.
VOLTS: Voltage display. Hz: Frequency display. AMPS: Current display. WATTS: Actual numerical power display. HOURS: Represents total operation time of the generator.
11
PREPARATIONS
1 Fuel
DANGER
· Fuel is flammable and toxic, please read the Safety Instruction carefully
before refueling; · Do not fuel too full, otherwise fuel will spill after fuel
tank is warmed; · After refueling, confirm that the fuel tank cap has been
tightened.
ATTENTION
· After refueling, dry gasoline residue with a clean and soft cloth in time to
avoid damaging plastic enclosure; · Unleaded gasoline must be used, as leaded
gasoline can seriously damage internal parts of the generator;
Remove fuel tank cap, and add gasoline to red horizontal indicating line oil
level. Fuel tank capacity: 3.3gal(12.5L)
2 Oil
No oil is filled into this generator when being delivered. Do not start up the
generator without filling sufficient oil.
1. Please place the generator onto a horizontal plane surface;
2. Loosen the two bolts on the right panel cover
and remove the left panel cover. Unscrew oil dipstick;
3. Fill in 0.21gal(0.8L) oil (SAE 10W/30 oil is
recommended, of which the grade is API standard Type SE or higher);
Don’t go over the scale
4. Oil to the appropriate position, tighten the dipstick, cover the right exterior cover, and tighten the bolts.
12
PREPARATIONS
3 Pre-use Inspection
WARNING
Even if the generator is not in service, its important component may suddenly
fails. Before the generator is started up, if any of following components is
unable to work properly, please inspect and repair carefully.
Tip: The condition of the generator shall be inspected before using every time. Pre-operation inspection
Project
Possible Causes
Probable Solutions
Fuel
Check fuel level in fuel tank of the generator.
Check oil level of the generator. Oil
Check whether there is oil leaking.
Abnormal conditions during operation
Check operating condition of the generator.
Battery
Check whether the battery is full.
Add fuel if necessary. Add oil if necessary.
If there is any need, please do not hesitate to consult your dealer. See the
“Battery Charging” page.
13
STARTING UP THE GENERATOR
1. Remove the load from all output ends; 2. Connect battery line before first
use:
1. Loosen the two bolts on the panel cover and remove the right outer cover;
2. A quick-connect battery plug is pre-installed on the battery. Remove the
cable tie securing the plugs, align colors, then push firmly to connect them.
3. Select the Fuel:
a. Gasoline: Turn the Fuel Source Switch to gasoline.
b. LPG:
1. Connect the LPG hose to the LPG tank;
2. Tighten the other end of the LPG hose to the generator intake;
3. Turn the Fuel Source Switch to LPG.
1
2
3
DANGER
Fire and explosion hazard. Always turn the propane tank valve to the fully
closed position if not running the generator on propane.
WARNING
When using the generator with propane, make sure there is no possible ignition
source close to the generator.
4. Press the LOW IDLE Switch to “OFF”;
14
STARTING UP THE GENERATOR
5. Press the Main Switch to “ON”;
6. Select Boot Mode:
a. Recoil Start: Pull the starting handle to start the generator.
b. Button Start: Press the button to start the generator. c. Remote Start: Press the “START” button on the remote control to start the generator.
a
b
c
7. Plug in after started.
Remote Control Pairing 1. Long press the start button for more than 5 seconds until the button red indicator is on; 2. Press any key on the remote control;
3. The red indicator of the start button will blink two or three times and then turns off, Remote start pairing is successful.
Tip If the next step is not taken within 5 seconds, the key pairing will exit.
The remote control delivered with the generator has been paired successfully.
1
2
3.1
3.2
TIP
Remote Control Key Dormancy When generator stops running for 5 days
(120hours), while the main switch is not turned off, the remote control key
cannot be used to start the generator again. At this time, you need to turn
off the main switch and turn it on again, or press the one-key start button
(or hand start) to start the generator, and the remote control key will be
reactivated.
15
STARTING UP THE GENERATOR
COMMON PROBLEMS WITH STARTING THE GENERATOR:
Start the generator to run normally without output ?
Check whether the green light of the GFCI socket is on. If the green light is
not on, press the RESET button after the generator is started to make the
green light on. Tip: When the generator is not started, the GFCI socket is in
the protected state and the “RESET” button cannot be pressed.
LPG startup is difficult ?
When both gasoline and propane are present in the generator it is recommended to start the generator on
gasoline first, allow the engine to stabilize then switch to propane.
1. Ensure the LPG supply hose is securely attached and Close the LPG valve
completely.
CLOSE
2. Fuel source rocker switch to “GASOLINE”. 3. Follow the startup steps to start the generator.
4. Open the LPG valve completely. 5. Fuel source switch to “LPG”.
OPEN
Electric start and remote start no response ?
1. Check whether the positive and negative electrodes of the battery are
correctly connected. 2. Check whether the battery is charged. 3. Check whether
the remote control is powered on.
16
STARTING UP THE GENERATOR
Parallel Operation The parallel connection ports allow you to connect two
generators to increase the total available electrical power. Follow the
instructions included with your parallel connection kit for proper
installation and operation. Overload Indicator Note: The OVERLOAD light may
turn on for a few seconds as a large device starts. This is normal for loads
approaching the capacity of this generator. 1. The total combined load through
the outlets on the generator must not exceed the running power of the unit. 2.
If the OVERLOAD light turns on and the generator stops producing power, it has
been overloaded. 3. Turn off and disconnect all electrical devices and stop
the engine. Compare device requirements to generator
rating and reduce the total wattage of connected devices if necessary. Move
anything that may be limiting generator ventilation away. 4. Check if any
circuit breakers have tripped and make sure that ALL circuit breakers are
reset before starting the generator again. 5. Restart the engine and reconnect
devices while being careful to not overload the generator. Low Oil Indicator
- If the engine oil level is too low, the LOW OIL light turns on and the
engine will automatically shut off. 2. The engine cannot be restarted until
the proper amount of oil has been added. Add the appropriate type of oil until
the oil level is at the proper level. SAE 10W-30 oil is recommended for
general use.
ATTENTION
Do not run the engine with too little oil. Engine will shut off if engine oil level is too low.
Low Idle 1. Turn on a Low Idle Switch to limit noise and fuel consumption with a light generator load. 2. Turn off the low idle mode to run the engine at full speed under the following conditions: Starting the generator. If the load exceeds 50%, it is recommended to turn off the low idle mode.
Voltage Selector The Voltage Selector allows more current to be available at 120V outlets if 240V output is not required: Switch to 120V only: 120V sockets and 120V/240V dual voltage sockets can be used, but 120V/240V dual
voltage sockets can only output 120V. Switch to 120V/240V: Both 120V and 240V outlets can be used. NOTE: Do not change the switch while under load. For parallel function, switch position must be at 120/240V.
17
STARTING UP THE GENERATOR
INVERTER PARALLEL KIT OPERATION
50A Parallel Kits
This parallel kit is intended to be used only with GENMAX inverter generators.
Please read safety information below before proceeding.
Round Connector (Black)
Ground Connectors (Ring) Square Connector (Black) Connectors(Red)
1. Make sure both engine switches are in the off position, and confirm the
Low idle switches on both generators are turned off.
2. Attach the ground terminal (green wire) from each end of the parallel
cable to the corresponding ground terminal on each generator. Connect and
tighten the ground wire.
3. Connect the black and red parallel cable leads to the black parallel ports
on each corresponding inverters control panel. DO NOT connect two red leads or
two black leads into the same inverter. 4. Connect the black square connector
to the square socket of the generator.
5. Start each generator and confirm that the green output indicator is
illuminated on both.
Tip: When two generators are connected in parallel, the voltage selector
switch must be placed at 120/240V before starting.
6. If using Low idle mode, turn both Low idle switches on after the
generators are started.
7. To shut down, turn off both generators and then remove the parallel cords.
Connectors (Red)
Square Connector (Black) Ground Connectors (Ring)
NOTICE: If high electrical loads are connected, turn the Low idle switch to the OFF position to Round reduce voltage changes. With the generators Connector running, make sure both green output indicator (Black) lights are ON. If not ON, turn the generators off, restart the generators, and make sure both green output lights are ON.
18
SHUTTING DOWN THE GENERATOR
1. Unplug the power cord;
a
b
2. Select Stop Mode:
a. Button Stop: Press the button to turn off the
generator.
b. Remote Stop: Press the “STOP” button on
the remote control to turn off the generator.
3. Press the Main Switch to “OFF”;
4. Turn the Fuel Source Switch to middle to turn off gasoline/LPG.
IMPORTANT NOTES
The above instructions for starting and stopping the generator are normal
procedures. Users must follow standard procedures to start, use and shut down
the generator.
1. If the user directly turns off the generator with the main switch, there
may be a sound of muffler blasting, which is a normal phenomenon under
abnormal operation.
2. When the battery is not connected or the battery is out of charge, if the
user directly turns off the generator with the main switch, it may be
difficult or impossible to start the cold machine, which is a normal
phenomenon under abnormal operation.
19
USING THE GENERATOR
1 Service Environment of the Generator
· Applicable temperature: 23~104 (-5°C ~ 40°C); · Applicable humidity: below
95%; · Applicable altitude: regions below 1,500 m (It shall be used by
reducing power in regions above 1,000 m). Standard atmospheric condition ·
Ambient temperature Tr: 298k (77/25°C) · Relative air humidity r: 30% ·
Absolute atmospheric pressure Pr: 100kPa When actual environmental condition
is inconsistent with the condition of output power of the generator set: ·
Every 41(5°C) of increase in ambient temperature will reduce the power of
generator by about 2%. · Every 30% of increase in relative humidity of air
will reduce the power of generator by about 1.5%. · Every 300 m rising of ASL
will reduce the power the generator by about 4.5%.
2 Generator Wiring
· When the generator is connected to household power source as a backup power
supply, the connection shall be carried out by a professional electrician or a
person familiar with electricity. · After connecting the load to the
generator, check carefully whether electrical connection is safe and reliable.
Improper electrical connection may cause generator damage, burning or fire. ·
Avoid connecting this generator to commercial power outlet. · When extending
the cable, be sure not to exceed its length. 60m cross-section area is 1.5mm²
100m cross-section area is 2.5mm² · The appearance of extension cable shall be
protected by a layer of tough and elastic rubber cover (IEC25) or other
substitutes.
OK
OK
20
USING THE GENERATOR
Connection of AC power
WARNING
All electrical equipment shall be disconnected before inserting the plug.
ATTENTION
· Make sure that all electrical equipment, including wires and plugs, are in
good condition before connecting to the generator; · Make sure that all loads
driven by the generator are within rated load range; · Make sure that load
current is within rated current range of rated socket. Tip: Make sure that the
generator set is grounded, and if electrical equipment requires grounding, the
generator set must be grounded. Start up the engine; Turn energy-saving switch
to “ON”; Insert the plug into AC outlet; Make sure that AC indicator is lit
up; Switch on electrical equipment. Tip: Before increasing engine speed,
energysaving switch must be switched to “OFF”. If the generator set supplies
power to multi loads or electrical equipment, start from large to small
according to the size of each electrical equipment.
3 Generator Grounding
In order to prevent any damage to the generator caused by electric shock or
improper electrical application, it is recommended that the generator is
grounded with good conductor with insulating sheath.
Please use grounding wire with sufficient electrical energy capacity; Connect
one end of grounding wire reliable to grounding bolt on control panel of the
generator set; Insert grounding body (iron rod with a diameter of 5 ~ 10mm)
200mm below into the earth and lead it out with conductor; Connect the other
end of the grounding wire reliable to the led wire of grounding body.
Tip: How to change the grounding method please refer to the website:
https://www.genmaxpower.com/page/faq
21
USING THE GENERATOR
4 Battery Charging
The battery storage time is generally about 6 months. If the generator is not
used for a long time, the battery will run out of power. At this time, the
battery should be charged. Replace the battery if it is damaged or fails to
charge. Hand start charging: Start the generator by hand, and the battery will
be charged automatically when the generator runs. Use an external power source
for charging:
Connect the charger to the battery charging port on the generator panel and
connect the mains to charge the battery.
WARNING
Do not start the generator while charging with an external power supply. Keep
batteries away from fire sources. Keep the battery in a cool and dry place,
away from direct sunlight. Keep batteries away from children.
ATTENTION
1. Charge properly Keeping battery properly charged and discharged can
prolong battery life. Maintaining a power level of 10%90% in battery is
beneficial for battery protection. 2. Choose the appropriate charging
temperature Battery charging temperature range: 32~113 (0~45). 3. Avoid
overcharging Overcharging of battery must be avoided during the charging
process. Overcharging of battery in any form will lead to serious damage to
battery performance and even explosion.
22
SERVICE AND MAINTENANCE
Good maintenance and service is the best guarantee for safe, economical and zero-failure operation. It also contributes to environmental protection. In order to keep the generator in good condition, you must inspect and maintain it regularly. The maintenance schedule is as follows:
Maintenance cycle Each
Item
Engine oil
Check-fill
Replace
Gearbox gear
Check oil
Oil (if any)
Replace
Air cleaner element
Inspection
Clean
Replace
Settling cup (if any) Clean
Spark plug
Clean-adjust
Spark eliminator Clean
Idle speed (if any)**
Check-adjust
First in 1 month or 20 hours
Then every three months or every
50 hours
100 hours per year or use
Valve clearance** Check-adjust
Fuel tank and fuel filter***
Clean
Fuel line
Cylinder head, piston
Inspection
Remove carbon deposit**
Every two years (Please replace if necessary)
Displacement < 225cc, every 125 hours; displacement capacity 225cc, every 250
hours.
- These items shall be replaced if necessary; ** These items shall be maintained by the dealer authorized by the Company, unless the user has proper tools and maintenance ability.
ATTENTION
· If it often works under high temperature or high load, oil shall be changed
every 25 hours; · If it often works in dusty or harsh environment, air cleaner
element shall be cleaned every 10 hours. If necessary, the air cleaner element
shall be replaced every 25 hours; · It shall be maintained on spot-inspection
cycle and time, whichever is earlier; · If maintenance cycle time has elapsed,
perform the maintenance as soon as possible as per the table above.
23
SERVICE AND MAINTENANCE
WARNING
Please shut down the engine first before performing any maintenance. The
engine shall be placed in a horizontal position. In order to prevent the
engine from starting up, separate spark plug cap shall be separated from spark
plug. Do not use it indoors or use it in a tunnel, cave or other places
ventilated poorly. Make sure that work area is well ventilated. Exhaust gas
from the engine contains toxic gases, carbon oxides, and the inhalation can
cause shock, loss of consciousness, and even death.
1 Spark Plug Inspection
Spark plug is an important part of the generator, which must be inspected
regularly.
1. Loosen the two bolts on the left panel cover,
remove the left panel cover, and remove the high voltage pack;
2. Insert the screwdriver into the sleeve, to screw it
counterclockwise, and then remove the spark plug;
3. Check whether there is discoloration, and remove carbon deposits.Check
whether there is little pale to moderate brown on ceramic cores around center
electrode of the spark plug;
4. Check the model of spark plug and clearance.
Spark plug gap: 0.7-0.8mm
Standard spark: BRAND
MODEL
NGK
BPR6ES
TORCH
F6RTC
CHAMPION RN11YC
BOSCH
WR6DS
0.7~0.8mm
Tip: The spark plug clearance is required to be measured by line thickness gauge, which shall be adjusted if necessary.
24
SERVICE AND MAINTENANCE
5. Install the spark plugs in reverse order of removal.
Spark plug torque: 22.5±2.5N.m(199±22in-lb)
Tip: If there is no torque wrench when installing the spark plug, a better
estimation method is to screw it 1/4-1/2 turns by force after screwing it in
place, but the spark plug shall be screwed to specified torque as soon as
possible.
2 Adjustment of the Carburetor
The carburetor is an important components of the engine. The adjustment shall
be carried out by a dealer with professional knowledge, professional data and
equipment, to ensure that the adjustment is proper.
3 Replacement of Oil
WARNING
Do not drain the oil immediately after turning off the generator. Oil
temperature is very high, when operating, take care to avoid scalding.
1. Put the generator on a horizontal plane, start the generator, run it for a
few minutes to make it warm, then
turn off the engine;
2. Loosen the two bolts on the right panel cover
and remove the left panel cover;
3. Place an oil pan under the engine, tilt the generator to quickly pour out
oil;
After discharging the oil, put the generator back on level ground;
25
SERVICE AND MAINTENANCE
4. Unscrew oil dipstick;
5. Oil to the appropriate position, tighten the dipstick, cover the right
exterior
cover, and tighten the bolts. Recommended oil: SAE S10W/30 Oil grade: API
standard Model SJ or higher Volume: 0.12gal(0.8L)
4 Air Filter
Dirty air cleaner may prevent air from flowing into the carburetor. In order
to prevent failure of the carburetor, please maintain air cleaner regularly.
If being used in a dusty environment, it shall be maintained frequently.
1. Loosen the bolt on the left appearance cover plate and remove the left
appearance cover plate;
2. Remove screws, to remove cover plate of air
cleaner ;
3. Clean foam cleaner element with cleaning solvent and blow it dry, Put a
few
drops of oil on the filter element.
ATTENTION
Be sure not to twist the foam cleaner element forcibly to avoid damage.
4. Put foam cleaner element into air cleaner;
Tip: Make sure that the surface of foam cleaner element is in close contact
with air cleaner, and there shall be no gap leaking air. Be sure not to start
the engine before air cleaner is assembled, because it will generate excessive
toxic gas and wear the cylinder;
26
SERVICE AND MAINTENANCE
5. 1. Reassemble empty air cleaner cap back to original position, and tighten
screws; 2. Assemble left outer cover and tighten bolts.
5 Fuel Filter Screen
WARNING
Be sure not to open fuel tank of the generator in a place where smoking or
with flame. 1. Remove fuel tank cap and fuel tank filter screen. 2. Clean fuel
tank filter screen with gasoline. 3. Wipe filter screen dry, and put it back
into fuel tank. 4. Reassemble fuel tank cap.
ATTENTION
Be sure to screw fuel tank cap tight.
27
STORAGE AND TRANSPORT
1 Generator Storage
If it is stored long-term, in order to prevent aging, you shall take some
storage measures.
1. Shut down generator. 2. Open fuel tank cap, to take out fuel filter
screen.
Pump all fuel in fuel tank into special fuel tank, and then reassemble fuel
tank cap back.
3. Start up the engine to burn off fuel in the carburetor, and then shut it
down.
Tip: Do not connect any electrical equipment. Running time of the engine
depends on remaining fuel in the fuel tank.
4. Open generator left exterior cover and enter carburetor. Locate the clear
plastic hose from the carburetor and place a suitable container under it to
capture the drained fuel.
5. Loosen the carburetor drain screws until you see fuel draining from the
carburetor.
6. Allow fuel to drain into the container and tighten the drain screws on the
carburetor. Install the engine service panel.
7. Unscrew oil dipstick, and drain oil in the crankcase off. Fill new oil to
upper oil limit, and then assemble
oil dipstick.
28
STORAGE AND TRANSPORT
8. Gently pull startup handle until you feel resistance, allowing both inlet
valve
and exhaust valve to be closed.
9. Disconnect the battery cable.
10. Place the generator set in a clean and dry area. 2 Generator Transport
· When the generator set is transported, it shall be ensured that there is no
fuel spilling; · Do not fill excessive fuel into fuel tank; · Do not run the
generator, and avoid direct sunlight; · Do not transport the generator set on
rough road for long time.
3 Preparation for Use After Storage
1. Slowly pull the starter cord a few times to clean oil from the cylinder or
to eject any pump protector from the pump which may have been added prior to
storage. 2. Remove the spark plug from the cylinder. Wipe oil from the spark
plug and return it to the cylinder and retighten. 3. Reconnect the spark plug
wire. 4. Refuel engine per earlier instructions in this manual.
29
TROUBLESHOOTING
30
TROUBLESHOOTING
31
TECHNICAL PARAMETERS
Item Rated Power (kW) Max. Power (kW)
Engine Model
Valve Clearance
Stroke x Bore (mm)
Engine Type
Displacement (cc)
Gas Distribution Mode Cooling Mode
Rated Speed (RPM)
Starting Method
Fuel Tank Volume (gal)
Fuel Type and Grade
Lubricating Oil Capacity (gal)
Lubricating Oil Model Noise dB (at 7m)(25% load) Rated Voltage (V)
Rated Frequency (Hz)
Rated Power Factor
Phase Number Run Time @ 25% (h) Fuel Consumption Rate (25% load)(L/h) Fuel
Consumption Rate (100% load)(L/h) LPG Consumption Rate (25% load)(kg/h) LPG
Consumption Rate (100% load)(kg/h) THD Overall Dimension (in.) Net Weight
(lb.)
GM7500iAED 6.0(GAS.)/5.5(LPG) 7.5(GAS.)/6.0(LPG)
180F/GL-2 Input valve0.07~0.13 mm, Output valve0.10~0.15 mm
80×62 4-stroke
312 OHV Forced cooling wind 3600 Recoil start/Electrical start/Remote start
3.3(12.5L) Vehicle-use unleaded gasoline 0.21(0.8L) SAE 10W/30
62 120/240
60 1 Single phase 10 1.35
3.3
0.75
2.2 3% 24.5×19.6×21.7(615×480×550mm) 118(53.5kg)
32
R
CHOOSING
A GENERATOR
1
33
In production management, based on orderly, efficient, scientific principles.
trying to do as better as possible in product design, development, production,
inspection,etc. to make our production can keep orderly . And will continue to
make improvement to make sure that keep the competitiveness. Welcome friends
at home and abroad to visit and guide, work together to create brilliant.
R
Caojie Industrial Park,Hechuan District,Chongqing Phone 866-960-2920 E-mail service@genmaxpower.com Http://www.genmaxpower.com/
YouTube
34
You Tube
f
6800.J54.GEM.02.00 V2
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>