D-Link DIS-300G 8 Port Gigabit Industrial Managed PoE Switch Installation Guide
- July 13, 2024
- D-Link
Table of Contents
D-Link DIS-300G 8 Port Gigabit Industrial Managed PoE Switch
Specifications
Model: DIS-300G Series Managed Industrial Gigabit Ethernet Switch
Designed for: Standard industrial applications
Product Usage Instructions
Overview
The Managed Ethernet Switch solutions are designed for supporting standard
industrial applications. Managed switches are easier to prioritize, partition,
and organize user’s network, providing a more reliable and better quality
services.
Package Checklist
Please verify the box contains the following items:
Item | Quantity |
---|---|
Management Ethernet switch | 1 |
Wall-mount plates | 2 |
DIN-Rail CLIP | 1 |
M3 Screws (for the wall mount plates & DIN CLIP) | 4 |
DC power terminal block | 1 |
RJ45 Ethernet port Dust Cover | Some |
SFP Ethernet port Dust cover | Same as SFP port number |
Safety Instructions
When handling fiber connections, be cautious of potential hazards from laser
radiation. Always follow safety guidelines to prevent eye damage. When a fiber
connection is removed during installation, testing, servicing or an active
fiber is broken, ocular exposure to optical energy may be potentially
hazardous, depending on the laser output power.
The primary hazards of exposing laser radiation from an optical-fiber communication systems are:
- Damage to eyes from accidental exposure to a beam emitted by a laser source.
- Damage to eyes from viewing the connector that attaches to a broken fiber or an energized fiber.
If the equipment is used in a manner not specified by the manufacturer, the protection provided by the equipment may be impaired.
DIN-Rail Mounting
- Screw the din-clip with screws in the accessory kit.
- Hook the unit onto the din-rail.
- Push the bottom of the unit towards the din-rail until it locks in place.
Wall Mounting
Mounting steps:
- Screw the wall-mount brackets with screws in the accessory kit.
Ethernet Interface (RJ45 Ethernet)
The switch provides RJ45 and SFP interfaces. Use appropriate cables for
connecting to PCs or Ethernet devices. The switch provides two types of
Ethernet interfaces: electrical (RJ45) and optical (SFP) interfaces.
Connecting the Ethernet interface via RJ45:
- To connect the switch to a PC, use straight-through or cross-over Ethernet cables,
- To connect the switch to an Ethernet device, use UTP (Unshielded Twisted Pair) or STP (Shielded Twisted Pair) Ethernet cables.
The pin assignment of RJ-45 connector is shown in the following figure and table.
Ethernet Interface (Fiber, SFP)
For fiber speed connections, use SFP slots with fiber transceivers. Be
cautious of laser energy emitted by optical connectors. For both 100/1000 Mbps
fiber speed connections, the SFP slots are available. The SFP slot accepts the
fiber transceivers that typically have an LC connector. The fiber transceivers
have options of multimode, single mode, long-haul or special-application
transceivers.
DANGER:
Never attempt to view optical connectors that might be emitting laser energy.
Do not power up the laser product without connecting the laser to the optical
fiber and putting the dust cover in position, as laser outputs will emit
infrared laser light at this point.
Connecting Power Terminal Block
Connect the DC power to a well-fused power supply for proper operation. The
switch can be powered from two power supplies (input range 12V – 58V). Insert
the positive and negative wires into V+ and V- contacts on the terminal block
respectively and tighten the wire-clamp screws to prevent the wires from being
loosened.
Note:
The DC power should be connected to a well-fused power supply.
DIS-300G-10SW/DIS-300G-12SW
DIS-300G-8PSW/DIS-300G-14PSW
Alarm Relay and Ground
The alarm relay output contacts are in the middle of the DC terminal block
connector as shown in the figure below. The alarm relay out is “Normal Open”,
and it will be closed when detected any predefined failure such as power
failures or Ethernet link failures. The relay output with current carrying
capacity of 0.5A @ 24 VDC
Console Connection
The Console port is for local management by using a terminal emulator or a
computer with terminal emulation software.
- DB9 connector connect to computer COM port
- Baud rate: 115200bps
- 8 data bits, 1 stop bit
- None Priority
- None flow control
To connect the host PC to the console port, a RJ45 (male) connector-to-RS232 DB9 (female) connector cable is required. The RJ45 connector of the cable is connected to the CID port of the switch; the DB9 connector of the cable is connected to the PC COM port.
The pin assignment of the console cable is shown below:
NOTE : When connecting to console port, please use the designate console cable attached in the package.
Connect & Login to Managed Switch
- Connecting to the Ethernet port (RJ45 Ethernet port) of Managed Switch.
- Factory default IP: 10.90.90.90
- Login with default account and password.
- Username: admin
- Password: admin
CLI Initialization & Configuration
- Connecting to the Ethernet port(RJ45 Ethernet port) of Managed Switch
- Key-in the command under Telnet: telnet 10.90.90.90
- Login with default account and password.
- Username: admin
- Password: admin
- Change the IP with commands listed below: CLI Command:
- enable configure terminal interface vlan 1 ip address xxx.xxx.xxx.xxx xxx.xxx.xxx.xxx exit
LED STATUS INDICATIONS
LED Name Indicator /color Condition
P1/P2
| On Green| P1/P2 power line has power
Off| P1/P2 power line disconnect or does not have power supplied
Alarm
| On Red| Ethernet link fails, alarm or power failure alarm occurs
Off| No Ethernet link fails and no power failure alarm
Copper port Link/Act
| On Green| Ethernet link up but no traffic is detected
Flashing Green| Ethernet link up and there is traffic detected
Off| Ethernet link down
Copper port Speed| On Yellow| A 1000Mbps connection is detected
Off| No link, a 10Mbps or 100 Mbps connection is detected
SFP port Link/Act| On Green| Ethernet link up
Off| Ethernet link down
SFP port Speed| On Yellow| SFP port speed 1000Mbps connection is detected.
Off| No link or a SFP port speed 100Mbps connection is detected
DIS-300G-8PSW/DIS-300G-14PSW only
RR
(Ring Role)
| On Green| One of 3 Ring group is enabled and is Master role.
Off| Ring is slave role
RS
(Ring Status)
| On Green| Ring fail happen and detected
Off| No ring fail detected
PoE
| On Yellow| PoE is detected
Off| No link
Additional Information
You can refer to the user manual or visit
http://support.dlink.com/ for more support.
Online Documentation
www.dlink.com/resources/business
Online Support
If there are any issues that are not in the user manual, please visit
http://support.dlink.com/ which will direct you to your appropriate local
D-Link support website.
Warranty Information
Visit http://warranty.dlink.com/ to view the D-Link Warranty information.
Federal Communication Commission Interference Statement
This equipment has been tested and found to comply with the limits for a
Class A digital device, pursuant to part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference when
the equipment is operated in a commercial environment. This equipment
generates, uses, and can radiate radio frequency energy and, if not installed
and used in accordance with the instruction manual, may cause harmful
interference to radio communications. Operation of this equipment in a
residential area is likely to cause harmful interference in which case the
user will be required to correct the interference at his own expense.
Non-modification Statement
Any changes or modifications not expressly approved by the party responsible
for compliance could void the user’s authority to operate the equipment.
Caution
This device complies with Part 15 of the FCC Rules.
Operation is subject to the following two conditions:
- This device may not cause harmful interference, and
- this device must accept any interference received, including interference that may cause undesired operation.
Innovation, Science and Economic Development Canada (ISED) Statement:
This Class A digital apparatus complies with Canadian ICES-003. Cet appareil
numérique de la classe A est conforme à la norme NMB-003 du Canada.
Japan Voluntary Control Council for Interference Statement
This is a Class A product based on the standard of the Voluntary Control
Council for Interference (VCCI). If this equipment is used in a domestic
environment, radio interference may occur, in which case the user may be
required to take corrective actions.
Warning:
This is a class A product. In a domestic environment this product may cause
radio interference in which case the user may be required to take adequate
measures.
FAQ
Q: What should I do if I encounter issues with the power supply?
A: Ensure that the DC power is connected properly and check the fuses for any
issues. Contact customer support if problems persist.
Q: Can I use standard Ethernet cables for connecting to the switch?
A: Yes, you can use UTP or STP Ethernet cables for connecting to PCs or
Ethernet devices.
References