Interface 3AR Sensor
Product Specifications
- Product Name: 3AR Sensor
- Manufacturer: Interface
- Mounting Surfaces: Measuring Platform (moving side) and Stator
- Fastening: Cylinder head screws and cylindrical pins
- Screw Diameter: M20
- Tightening Torque:
- Measuring Platform: 8.8 / 400Nm, 10.9 / 550Nm, 12.9 / 700Nm
- Stator: 8.8 / 400Nm, 10.9 / 550Nm, 12.9 / 700Nm
- Mounting Surface Requirements:
- High rigidity with no deformation under load
- Flatness: 0.05 to 0.1mm
- Surface Quality: Rz6.3
Product Usage Instructions
Measuring Platform Mounting:
The measuring setup must be attached to the mounting surface of the
measuring platform of the 3AR sensor using the specified cylinder head screws
and cylindrical pins.
Steps:
- Ensure the mounting surface meets the specified requirements.
- Use the correct screw diameter and tightening torque as per the table.
- Fasten the setup with 8x cylinder head screws and position with 2x cylindrical pins.
Stator Mounting:
The 3AR sensor must be attached to the screwing surface of the stator
following the provided guidelines.
Steps:
- Prepare the stator surface ensuring it meets the specified requirements.
- Utilize the recommended screws, pin holes, and tightening torques as indicated in the manual.
- Secure the sensor with 8x cylinder head screws and align using 2x cylindrical pins.
General Notes:
- Always refer to the provided table for strength class and tightening torque information.
- Ensure proper screw depth in both the measuring platform and stator.
- Follow ISO standards for tolerances and surface finish.
Frequently Asked Questions
-
Q: Can I use different screws for mounting the sensor?
A: It is recommended to use the specified cylinder head screws for mounting to ensure proper installation and performance. -
Q: What should I do if the mounting surface does not meet the specified requirements?
A: It is crucial to have a rigid and flat mounting surface. If it does not meet the requirements, consult with a professional to rectify the surface before installation. -
Q: Is it necessary to use all 8 screws for fastening?
A: Yes, it is important to use all 8 cylinder head screws for secure attachment of the sensor to the mounting surfaces.
3AR Installation:
Please note the following instructions for installing the 3AR products from
Interface. For professional installation, the 3AR sensor must be attached to
the special marked screw surfaces.
Mounting surface measuring platform
Mounting surface stator
Mounting surface requirements
- high rigidity of the screwing surface, no deformation under load
- Flatness of the screwing surface 0.05 to 0.1mm
- Surface quality of the screwing surface Rz6.3
Number| Designation| Strength class/ Tightening torque (Nm) Measuring
platform| Strength class/ Tightening torque (Nm) Stator
---|---|---|---
8| Cylinder head screw DIN EN ISO 4762 M20| 8.8 / 400Nm
10.9 / 550Nm
12.9 / 700Nm| 8.8 / 400Nm
10.9 / 550Nm
12.9 / 700Nm
2| Cylinder pins DIN6325 Ø12m6
| Standard
ISO 128| General tolerances
ISO 2768-| Refer to protection notice ISO 16016|
---|---|---|---|---
Surface finish
DIN EN ISO 1302| This 2D drawing is essential for production and assembly.
Alternative file formats (e.g. Step and Dxf) are only for additional info.|
Thread countersinking DIN 76 under 90° to 120° until Thread outer diameter|
Interface, Inc. • 7418 East Helm Drive • Scottsdale, Arizona 85260 USA
Phone: 480.948.5555
Fax: 480.948.1924
www.interfaceforce.com
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>