Product Specifications

  • Manufacturer: SprintRay, Inc.

  • Product Name: SprintRay EU Temporary Crown & Teeth

  • Materials: Functional (meth)acrylic resins and inorganic fillers

  • Particle Sizes: 0.4 to 3 microns

  • Connector Area Presetting:

    • Anterior Bridges: 12 mm2
    • Posterior Bridges: 14 mm2
  • Minimum Wall Thickness:

    • Occlusal: 1.5 mm (central fissure)
    • Circumferential: 1 mm
  • Radiation Penetration Depth: Controllable by exposure time,
    ranging from 100 m (4 mils) to 125 m (5 mils)

  • Available Variants:

    • 1 kg: A1, A2, A3, A3.5, B1, B2, bleach
    • 500 g: A1, A2, A3, A3.5, B1, B2, bleach
  • Wavelength: 405 nm

  • UMDNS Code: 16-697

Product Usage Instructions

Indication
SprintRay EU Temporary Crown & Teeth is used for the generative production of long-term temporary dental restorations based on image projection systems.

Contraindication
SprintRay EU Temporary Crown & Teeth restorations are contraindicated in the following cases:

  1. If a patient is known to be allergic to any of the ingredients.
  2. For bridges with more than one pontic.
  3. For any application that is not part of the indication.

Requirements

Software: RayWare (CAD)

Hardware

  • Pro Desktop 3D (3D Printing)
  • Pro Wash / Dry (Cleaning)
  • ProCure (Post Curing)

Frequently Asked Questions (FAQ)

Q: Can this product be used for permanent dental restorations?
A: No, SprintRay EU Temporary Crown & Teeth is specifically designed for long-term temporary dental restorations.

SprintRay EU Temporary Crown & Teeth Instruction for use

Indication

SprintRay EU Temporary Crown & Teeth is a resin for the generative production of long term temporary dental restorations based on image projection systems.

Contraindication

SprintRay EU Temporary Crown & Teeth restorations are contraindicated …

  1. if a patient is known to be allergic to any of the ingredients.
  2. for bridges with more than one pontic.
  3. for every application that is not part of the indication (see above).

Requirements

Software

  • RayWare (CAD)

Hardware

  • Pro Desktop 3D (3D Printing)
  • Pro Wash / Dry (Cleaning)
  • ProCure (Post Curing)

SprintRay, Inc., 3577 North Figueroa St., Los Angeles, CA 90065

Material
SprintRay EU Temporary Crown & Teeth consists of functional (meth)acrylic resins and inorganic fi llers with particle sizes from 0.4 to 3 microns.

Geometric presetting
Connector areas (minimum):

  • anterior bridges 12 mm2
  • posterior bridges 14 mm2
  • Minimum wall thickness:
  • occlusal 1.5 mm (central fi ssure)
  • circumferential 1 mm

Material parameters

Radiation penetration depth controllable by exposure time

  • ≥ 100 μm (4 mils)
  • ≥ 125 μm (5 mils)

The manufacturing process (fi g. 1-10)

SprintRay-B1-EU-Temporary-Crown-Teeth- \(1\)

Individualization and cementation
The temporary restorations can be individualized by light curing composite materials. The reduction of the restoration should not exceed 0.3 mm (incisal and vestibular area). Please follow the instructions of the light curing composite manufacturers. For cementation common provisional dental cements (free of Eugenol) and adhesives are suitable. The inner areas of the crown should be conditioned by sandblasting or other commonly used techniques. Please follow the instructions and indications of the corresponding manufacturers.

Notice
Please follow the instructions provided by the software manufacturer in terms of parameter settings and design recommendations. Please follow the instructions provided by the hardware manufacturer in terms of parameter settings/printing & post-curing recommendations. To avoid detrimental effects on material quality do not expose the liquid material to irradiation under any circumstances. Deviations from the described manufacturing processes or storing conditions may lead to different mechanical and optical properties of the material. Ensure personal protective gear during processing. Caution: Polymerized resins are chemically resistant – avoid stains on clothing! Avoid any contact with skin and eyes! In case of accidental contact, rinse with adequate running water, consult a doctor if necessary. The lot number and the best-before date are indicated on each packaging. In case of claims please always indicate the lot number of the product. Do not use the product after expiry of the best before date. Dispose
of contents/container according to official regulations.

Hazard statements
Causes skin irritation. May cause an allergic skin reaction. Causes serious eye damage. May cause respiratory irritation. Harmful to aquatic life with long lasting effects.

UMDNS 16-697

Physical properties
SprintRay EU Temporary Crown & Teeth

SprintRay EU Temporary Crown & Teeth

  • Flexural strength/MPa (ISO 4049): > 100
  • Modulus of elasticity/ MPa (ISO 4049): > 2000
  • Water absorption/ cumple con ISO 10477
  • Solubility/ conforme a ISO 10477
  • Inorganic filler/ 40.0 m-%

Ordering information

SprintRay EU Temporary
Crown & Teeth

  • 1 kg:
    • ≤ 405 nm
  • A1
    • REF: SRE-1001441
  • A2
    • REF: SRE-1001442
  • A3
    • REF: SRE-1001443
  • A3.5
    • REF: SRE-1001617
  • B1
    • REF: SRE-1001618
  • B2
    • REF: SRE-1001623
  • bleach
    • REF: SRE-1001624
  • 500 g :
    • ≤ 405 nm
  • A1
    • REF: SRE-1001612
  • A2
    • REF: SRE-1001613
  • A3
    • REF: SRE-1001614
  • A3.5
    • REF: SRE-1001620
  • B1
    • REF: SRE-1001622
  • B2
    • REF: SRE-1001625
  • bleach
    • REF: SRE-1001626

SprintRay-B1-EU-Temporary-Crown-Teeth- \(4\)

SprintRay-B1-EU-Temporary-Crown-Teeth- \(6\)

Manufacturer
pro3dure medical GmbH
Am Burgberg 13 · 58642 Iserlohn, Germany
Phone: +49 (0)2374 920050-0 · Fax +49 (0)2374 920050-50
[email protected] · www.pro3dure.com · Made in Germany

Distributor:
SprintRay Europe GmbH
Brunnenweg 11 · 64331 Weiterstadt · Germany

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

SprintRay User Manuals

Related Manuals