Wink Door/Window Sensor Wink D/W Sensor Manual
- June 8, 2024
- Wink
Table of Contents
- Wink
- Wink Door/Window Sensor
- SKU: Wink D/W Sensor
- Quickstart
- Important safety information
- What is Z-Wave?
- Product Description
- Prepare for Installation / Reset
- Inclusion/Exclusion
- Communication to a Sleeping device (Wakeup)
- Quick trouble shooting
- Association – one device controls an other device
- Configuration Parameters
- Technical Data
- Supported Command Classes
- Controlled Command Classes
- Explanation of Z-Wave specific terms
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Wink
Wink Door/Window Sensor
SKU: Wink D/W Sensor
Quickstart
This is a ****
Alarm Sensor
for
U.S. / Canada / Mexico.
Please make sure the internal battery is fully charged.
To add this device to your network execute the following action:
Follow the instructions for your Z-Wave certified Controller to enter
inclusion mode.When prompted by the Controller:1. For proper inclusion, bring
the Door/Window Sensor within range of your Controller.2. Pull the battery tab
on the backside of the sensor to power on, or remove then re-install the
batteries. The LED light should blink.
Please refer to the
Manufacturers
Manual for more information.
Important safety information
Please read this manual carefully. Failure to follow the recommendations in
this manual may be dangerous or may violate the law.
The manufacturer, importer, distributor and seller shall not be liable for any
loss or damage resulting from failure to comply with the instructions in this
manual or any other material.
Use this equipment only for its intended purpose. Follow the disposal
instructions.
Do not dispose of electronic equipment or batteries in a fire or near open heat sources.
What is Z-Wave?
Z-Wave is the international wireless protocol for communication in the Smart
Home. This
device is suited for use in the region mentioned in the Quickstart section.
Z-Wave ensures a reliable communication by reconfirming every message ( two-
way
communication) and every mains powered node can act as a repeater for other
nodes
( meshed network ) in case the receiver is not in direct wireless range of
the
transmitter.
This device and every other certified Z-Wave device can be used together
with any other
certified Z-Wave device regardless of brand and origin as long as both are
suited for the
same frequency range.
If a device supports secure communication it will communicate with other
devices
secure as long as this device provides the same or a higher level of security.
Otherwise it will automatically turn into a lower level of security to
maintain
backward compatibility.
For more information about Z-Wave technology, devices, white papers etc.
please refer
to www.z-wave.info.
Product Description
The Wink Door/Window Sensor is a Z-Wave Plus battery-powered device that detects when a door, window, or cabinet is opened and closed in your home, helping you monitor activity around your home to keep your family safe. Works with exterior and interior doors, garage doors, patio doors, windows, cabinets, drawers, and other openings. When your sensor detects activity, your Wink Hub or other Z-Wave Plus certified hub can send an alert to your smartphone, set off an alarm or chime, or trigger an automation such as turning on your lights. The Wink Door/Window Sensor offers an extra-long z-wave wireless range of up to 150 feet, and requires a Wink Hub or other Z-Wave Plus certified hub for operation. The Wink Door/Window sensor comes with a CR14250 battery and has a three-year battery life, and will send an alert to your smartphone via the hub when the device has low battery. Z-Wave Plus CertifiedRequires a Z-Wave Plus Certified Hub to operateWorks with all Z-Wave Plus compatible networksUp to 150 feet rangeThree-Year Battery Life (CR14250 Battery included)Low Battery IndicationMeasurements in millimeters: 19 x 66.3 x 20.2 mm (sensor) and 10 x 39.55 x 10.5 mm (magnet)
Prepare for Installation / Reset
Please read the user manual before installing the product.
In order to include (add) a Z-Wave device to a network it must be in factory
default
state. Please make sure to reset the device into factory default. You can do
this by
performing an Exclusion operation as described below in the manual. Every
Z-Wave
controller is able to perform this operation however it is recommended to use
the primary
controller of the previous network to make sure the very device is excluded
properly
from this network.
Reset to factory default
This device also allows to be reset without any involvement of a Z-Wave
controller. This
procedure should only be used when the primary controller is inoperable.
If needed, the Door/Window Sensor can be reset locally by following these steps. Only do this when your Z-Wave controller is disconnected or otherwise unreachable. Beware that resetting your device will disconnect it from the system:1. Remove the SENSOR COVER and confirm that your Door/Window Sensor is powered up.2. Press and hold the BUTTON for at least 10 seconds then release. A flashing light indicates a successful factory reset.3. The Door/Window Sensors memory will be erased to factory settings.
Inclusion/Exclusion
On factory default the device does not belong to any Z-Wave network. The
device needs
to be added to an existing wireless network to communicate with the
devices of this network.
This process is called Inclusion.
Devices can also be removed from a network. This process is called
Exclusion.
Both processes are initiated by the primary controller of the Z-Wave network.
This
controller is turned into exclusion respective inclusion mode. Inclusion and
Exclusion is
then performed doing a special manual action right on the device.
Inclusion
Follow the instructions for your Z-Wave certified Controller to enter inclusion mode.When prompted by the Controller:1. For proper inclusion, bring the Door/Window Sensor within range of your Controller.2. Pull the battery tab on the backside of the sensor to power on, or remove then re-install the batteries. The LED light should blink.
Exclusion
Follow the instructions for your Z-Wave certified Controller to enter exclusion mode. When prompted by the Controller:1. Press the sensor cover release button to remove the top cover, and be sure the sensor is powered on.2. Press the Connect Button next to the battery quickly 3 times in a row.The LED indicator will flash five times indicating exclusion/disconnection
Communication to a Sleeping device (Wakeup)
This device is battery operated and turned into deep sleep state most of the
time
to save battery life time. Communication with the device is limited. In order
to
communicate with the device, a static controller C is needed in the
network.
This controller will maintain a mailbox for the battery operated devices and
store
commands that can not be received during deep sleep state. Without such a
controller,
communication may become impossible and/or the battery life time is
significantly
decreased.
This device will wakeup regularly and announce the wakeup
state by sending out a so called Wakeup Notification. The controller can then
empty the mailbox. Therefore, the device needs to be configured with the
desired
wakeup interval and the node ID of the controller. If the device was included
by
a static controller this controller will usually perform all necessary
configurations. The wakeup interval is a tradeoff between maximal battery
life time and the desired responses of the device. To wakeup the device please
perform
the following action:
Because the Door/Window Sensor is a battery powered device, it wakes up on regular intervals to give battery and other status updates to the controller, as well as to accept configuration settings from the controller (as opposed to always remaining online and draining its battery.) The device can be forced to wake up (to submit these reports or accept new settings immediately) by simply pressing and holding the BUTTON for two seconds.
Quick trouble shooting
Here are a few hints for network installation if things dont work as expected.
- Make sure a device is in factory reset state before including. In doubt exclude before include.
- If inclusion still fails, check if both devices use the same frequency.
- Remove all dead devices from associations. Otherwise you will see severe delays.
- Never use sleeping battery devices without a central controller.
- Dont poll FLIRS devices.
- Make sure to have enough mains powered device to benefit from the meshing
Association – one device controls an other device
Z-Wave devices control other Z-Wave devices. The relationship between one
device
controlling another device is called association. In order to control a
different
device, the controlling device needs to maintain a list of devices that will
receive
controlling commands. These lists are called association groups and they are
always
related to certain events (e.g. button pressed, sensor triggers, …). In case
the event happens all devices stored in the respective association group will
receive the same wireless command wireless command, typically a ‘Basic Set’
Command.
Association Groups:
Group NumberMaximum NodesDescription
1| 5| Group 1 is the Lifeline group, which can hold five members, typically
including the main Z-Wave controller. The Door/Window Sensor sends this group
a Notification Report and a Binary Sensor Report when it is opened or closed.
It also sends this group a Battery Report in response to Battery Get commands.
---|---|---
2| 5| The Door/Window Sensor sends a Basic Set command to association Group 2
(or the Control Group) to directly trigger devices (like a light, chime, etc.)
in response to events. Then, after a preset delay, a BASIC_SET(0x00) command
is sent to reset the device (e.g. turn off the light.) The value of the Basic
Set command (e.g. brightness of the lamp,) and the delay time before the
BASIC_SET(0x00) is sent is configured using configuration parameters 1 and 2
respectively.
3| 5| Group 3 supports up to 5 members and the Door/Window Sensor sends it a
NOTIFICATION_REPORT when the door either opens or closes.
4| 5| Group 4 supports up to 5 members and the Door/Window Sensor sends it a
SENSOR_BINARY_REPORT when the door either opens or closes.
Configuration Parameters
Z-Wave products are supposed to work out of the box after inclusion, however
certain configuration can adapt the function better to user needs or unlock
further
enhanced features.
IMPORTANT: Controllers may only allow configuring
signed values. In order to set values in the range 128 … 255 the value sent in
the application shall be the desired value minus 256. For example: To set a
parameter to 200 it may be needed to set a value of 200 minus 256 = minus
56.
In case of a two byte value the same logic applies: Values greater than 32768
may
needed to be given as negative values too.
Parameter 1: BASIC_SET Off Delay
_This parameter sets the delay time from when the Door/Window Sensor sends
the BASIC_SET command to Association Group 2 and when the BASICSET(0) is
sent. It accepts a value up to 65535, in seconds.
Size: 2 Byte, Default Value: 30
SettingDescription
1 – 65535 | in seconds |
---|
Parameter 2: BASIC_SET Level
_This parameter sets the value sent by the BASICSET command to Association
Group 2 (for more information, see Association Groups.)
Size: 1 Byte, Default Value: 99
SettingDescription
0 | Off/Cancel Alarm/Etc. |
---|---|
1 – 99 | Dim Level (for Multilevel Switch) |
255 | On (for Binary Switch) |
Technical Data
Hardware Platform | ZM5202 |
---|---|
Device Type | Notification Sensor |
Network Operation | Reporting Sleeping Slave |
Firmware Version | HW: 65 FW: 3.61 |
Z-Wave Version | 6.51.06 |
Certification ID | ZC10-17075685 |
Z-Wave Product Id | 0x017F.0x0100.0x0001 |
Supported Notification Types | Access Control |
Sensors | Open/Closed (Binary) |
Color | White |
Frequency | XXfrequency |
Maximum transmission power | XXantenna |
Supported Command Classes
- Association Grp Info
- Association V2
- Battery
- Configuration
- Device Reset Locally
- Manufacturer Specific
- Notification V4
- Powerlevel
- Sensor Binary V2
- Version V2
- Wake Up V2
- Zwaveplus Info V2
Controlled Command Classes
- Basic
Explanation of Z-Wave specific terms
-
Controller — is a Z-Wave device with capabilities to manage the network.
Controllers are typically Gateways,Remote Controls or battery operated wall controllers. -
Slave — is a Z-Wave device without capabilities to manage the network.
Slaves can be sensors, actuators and even remote controls. -
Primary Controller — is the central organizer of the network. It must be
a controller. There can be only one primary controller in a Z-Wave network. -
Inclusion — is the process of adding new Z-Wave devices into a network.
-
Exclusion — is the process of removing Z-Wave devices from the network.
-
Association — is a control relationship between a controlling device and
a controlled device. -
Wakeup Notification — is a special wireless message issued by a Z-Wave
device to announces that is able to communicate. -
Node Information Frame — is a special wireless message issued by a
Z-Wave device to announce its capabilities and functions.
Read User Manual Online (PDF format)