Premium PAC Series Air Conditioner User Manual

July 12, 2024
Premium

Premium PAC Series Air Conditioner

Product Specifications:

  • Model Options: PAC9040A, PAC12040A, PAC12520A, PAC13040A, PAC18040A, PAC24040A
  • Type: Air Conditioner

Product Usage Instructions

Safety Precautions:

It is important to follow the safety precautions provided in the manual to prevent harm or damage. The seriousness of not following instructions is classified as follows:

  • WARNING: This symbol indicates the possibility of death or serious injury.
  • CAUTION: This symbol indicates the possibility of injury or damage to properties only.

Some safety precautions include proper grounding of the air conditioner, avoiding pulling the power cord forcefully and keeping a safe distance from flammable materials.

Operation:

The operation of the air conditioner can be done using the remote controller or manually. Before operation, it is recommended to check for any issues and follow safety tips.

Care and Maintenance:

Regular cleaning and maintenance are essential for the proper functioning of the air conditioner. Cleaning should be done periodically, and troubleshooting tips are available in the manual.

Installation Guide:

For proper installation, refer to the installation guide provided. It is important to follow the instructions carefully to ensure efficient operation of the air conditioner.

Product Usage Instructions:

The air conditioner can be used in various modes such as automatic operation, cooling/heating operation, fan operation, and drying operation. The remote controller also features a nightluminous function.

FAQ

  • Q: What should I do if the air conditioner is not cooling/heating properly?
    • A: Check the filters for any blockages and ensure proper airflow. If the issue persists, refer to the troubleshooting section in the manual.
  • Q: How often should I clean the air conditioner?
    • A: It is recommended to clean the air conditioner at least once every few months to maintain optimal performance.

Safety Precautions

Incorrect operation due to ignoring instruction will cause harm or damage. The seriousness is classified by the following indications

WARNING
This symbol indicates the possibility of death or serious injury.

CAUTION
This symbol indicates the possibility of injury or damage to properties only

WARNINGPremium-PAC-Series-Air-Conditioner-fig \(1\)

CAUTION

  1. Do t install the indoor unit under direct sunlight.
  2. Don t block air inlet or air outlet, otherwise, the cooling or heating capacity will be weakened, even causing the system stop operating.
  3. Don t apply the cold air to the body for a long time. It will deteriorate your physical condition and cause health problems.
  4. Close the windows and doors, otherwise, the cooling or heating capacity will be weakened.
  5. If the air filter is very dirty, the cooling or heating capacity will be weakened. Please clean the air filter regularly.
  6. It is prohibited to stand or put things onto the top of the outdoor, to avoid drop or damage. In no case should children be allowed to sit on the outdoor unit.
  7. Set a suitable temperature, especially if there are old people, children and patients in the room. Generally, keep the temperature difference for 5 between the inside and outside.
  8. In case the unit closes down due to severe interference from outer environments such as mobile phones, please cut off the plug and plug in to restart the air conditioner after several seconds.
  9. It is forbidden to let the air conditioner keep precision instrumentation, and artistic production for a long time and make food fresh, otherwise abnormal use will cause damage and weaken.
  10. It is forbidden to let children and the disabled use air-conditioning without adult super vision.
  11. Open windows frequently after using air-conditioning for a long time.
  12. If the equipment emissions cannot meet the technical requirement of IEC 61000-3-3, the Following Attention should be taken care.

Attention!

Through poor conditions of the electrical MAINS, shortly voltage drops can appear when starting the EQUIPMENT. This can influence other equipment (eg. the Blinking of a lamp). If the MAINS-IMPEDANCE Zmax< OHM(See attached nameplate), such disturbances are not expected. (In case of need, you may contact your local supply authority for further information).

WEEE Warning

Meaning of crossed-out wheeled dustbin:

Do not dispose of electrical appliances as unsorted municipal waste, use separate collection facilities. Contact you local government for information regarding the collection systems available. If electrical appliances are disposed of in landfills or dumps, hazardous substances can leak into the groundwater and get into the food chain, damaging your health and well-being. When replacing old appliances with new ones, the retailer is\ legally obligated to take back your old appliance for disposals at least free of charge

Parts Names

Premium-PAC-Series-Air-Conditioner-fig \(3\)

Indoor Unit

  1. Front panel

  2. Air filter

  3. Handling switch

  4. Louver

  5. Signal receptor

  6. Supply cord

  7. Remote controller

  8. Drain hose

  9. Refrigerant gas/ liquid pipe
    Outdoor Unit

  10. Cut-off valve

  11. Air outlet cover

Note:

  1. If the power supply from outdoor unit, you can find the power supply card is fitted in the outdoor unit.
  2. The descriptions in this user manual text and figures may have slight differences to the promotion information and actual appliance. Please refer to the real appliance purchased, Thank you

Operation

Remote controller operation

See air conditioner remote controller instruction

Manual operation

When the remote controller does not work or can not be found, please follow these steps:

  1. As the unit is operating, you can press the Auto button to stop operating.
  2. As the unit is stopping, you can press the Auto button to start operating.

Adjusting airflow direction

  1. Adjusting horizontal Adjusting h air flow manually.
    Use your hands to move the vertical airflow vane and change the horizontal wind direction.

Note:

  • a. Adjust the horizontal air flow direction before the air-conditioner starts. Don t insert your finger into air intake or outlet vents when the air-conditioner is operating.
  • b. For appliances with auto pendulum wind function, please refer to air conditioner remote controller instructions for how to adjust horizontal air flow.

Adjusting airflow direction

  1. Adjusting horizontal Adjusting h air flow manually. Remote controller operation See air conditioner remote controller instruction
  2. Adjusting vertical airflow direction(up-down) Refer to air conditioner remote controller instruction for how to adjust vertical airflow direction by adjusting the horizontal airflow vane by remote controller.

Note:

Adjust the vertical air flow direction by remote controller. When you adjust the horizontal airflow vane by hand, the machine may cause problem.

  •  Manual operation can be used temporarily in case you can not use remote controller or its batteries are exhausted.
  • When the air-conditioner stops, the horizontal wind vane will close the wind outlet of air conditioner.

Notices

To prevent injury and property damage, Please pay attention to the following before operating the air conditioner.

Checking before operation

  1. Make sure that the ground wire is connected safely and reliably.
  2. Make sure the filter net is properly fixed.
  3. Make sure that air outlet and inlet are not blocked.
  4. Please clean the filter before starting the air-conditioner referring to Cleaning for how to operate.
  5. Check to see whether the outdoor install bracket is damaged. If yes, please contact our Service center locally.

Safety tips

In order to use the air conditioner properly, please refer to its working temperature range. Otherwise, the indoor unit’s automatic protection function may be activated, and cooling or heating efficiency will be weakened.

The air-conditioner may turn in normal following under the mentioned table

Cooling

| Outdoor| 18
---|---|---
Indoor| 43

Heating

|

Outdoor

| 24
-7
Indoor| 27
Dehydrating| Indoor| 18

Care and Maintenance

Cleaning

Cleaning the indoor unit

  1. Turn offthe air-conditioner and remove the electrical plug from the outlet.
  2. Wipe the indoor unit with dry cloth or wet cloth which is dipped by cold water.

Note :

  • Don’t use water above 45°C to wash the panel, or it could cause deformation or depigment.
  • Don’t use thinner, polishing powder, benzene and other volatile chemicals.
  • Don’t use liquid or corrosive detergent to clean the appliance and don’t splash water or other liquid onto it, otherwise, it may damage the plastic components, even cause electric shock.

Cleaning air filterPremium-PAC-Series-Air-Conditioner-fig
\(6\)

  1. Raise up the front panel of indoor unit until it suddenly stops, then raise up the protruded part of filter, and then take it out.
  2. Use a vacuum cleaner or wash it with water, then dry it in the shade.
  3. Reinsert the air filter into the indoor unit until being entirely fixed, then close the front panel.

Maintenance

  1. Select “FAN” operation mode, and make the air conditioner run a long time to dry.
  2. Turn offthe air conditioner and cut off the power supply.
  3. Take out the batteries from the remote controller.
  4. Clean air filters and other parts.

Troubleshooting

Check the following before requesting on service centre if the malfunction occurs.

Phenomenon Troubleshooting

Air conditioner does not operate at all

| Has the power been shut down? Is the wiring loose?

Is the voltage higher than 1.1 times of max max-rated voltage or lower than 0.9 times of min rated voltage?

Is the fuse burnt?

Does it reach the set time for start up?

Phenomenon Troubleshooting

Remote controller is not available

| Is the remote controller out of effective distance to the indoor unit?

Is the battery exhausted?

Are there any obstructions between the controller and the signal receptor?

Cooling (Heating)efficiency is not good

| Is the setting temperature suitable? Is the air inlet or outlet obstructed? Are air filter dirty?

Is indoor fan speed set at low speed?

Is there any heat source in your room?

Indoor unit does not operate immediately when the air conditioner is restarted| Once the air conditioner is stopped, it will not operate in approximately 3 minutes to protect itself.

There is an unusual smell blowing from the outlet after the operation is started.

| This is caused by the odour in the room permeated from building material, furniture, or smoke.
The sound of water flow can be heard during cooling operation| This is caused by the refrigerant flowing inside the unit.

Mist is emitted during cooling operation.

| Because the air of the room is cooled down rapidly by the cold wind and it looks like the fog.
Mist is emitted during heating operation.| This generate due to moisture in the defrosting process.
| A low hissing sound is caused by
Low noise can be heard during operation| the refrigerant flowing.

A low squeak sound is caused by

the deformation of plastic due to

| temperature.

In case any of the following situations happen, please immediately stop all operations and cut off the power supply, then contact with service centre.

  • The fuse and switch often breaks.
  • Carelessly splash water or something into air conditioner.
  • Unusual noise can be heard during operation.
  • Electrical wiring and power plug are very hot.
  • Wind blowing from the outlet smells terrible during operation.
  • The Run light or other display flashes rapidly and keeps flashing after repluging.

Installation Guide

Guide for customer

  1. The installation must be done by a professional according to the “Installation instructions”
  2. The wiring must be did by a qualified electrician according to the electrical safety requirements.
  3. The customer should have a qualified power supply that coincides with the tag of air conditioner, the normal voltage should be in the range of 90-110% of its rated voltage.
  4. The air conditioner must be well grounded, the switch of the main power of air- the conditioner must be reliably grounded.
  5. If your air conditioner is not fitted with a supply cord and a plug, an all-pole switch must be installed in the fixed wiring and the distance between contacts should be no less than 3.0 mm.
  6. If your air conditioner is permanently connected to the fixed wiring and have a leakage current that may exceed 10 mA, a leakage protector must be installed in the fixed wiring.
  7. The power supply circuit should have a leakage protector and air switch of which the capacity should be more than 1.5 times of the maximum current.

Notices

  1. The air conditioner must be installed on well strong supporter.
  2. The appliance shall be installed in accordance with national wiring regulations.
  3. Fix the machine firmly, otherwise, it will produce abnormal noise and vibration.
  4. Install the outdoor unit in a place where it wouldn t disturb your neighbor.
  5. The method of connection of the appliance to the electrical supply and interconnection of separate components, please see the electric connection elements shart which stick on the machine.
  6. Is the power supply cord is damaged, it must be replaced by the manufacturer or its service agent or a similarly qualified person.
  7. After installation, the power plug should be easily reached.

Buttons description

Premium-PAC-Series-Air-Conditioner-fig
\(11\)

  1. “ON/OFF” button
    You can start the air-conditioner by pressing this button and stop its operation by pressing it again.

  2. “FRESH” button
    This button is invalidation.

  3. “SPEED” button
    You can select fan speed show as follows:

  4. “STRONG” button
    Only under the state of cooling or heating mode, press this button, the fan speed is adjusted to strong automatically and the LCD displays “high fan”, the “strong” function is started to reach the highest cooling or heating.

  5. “FEELING” button
    When it displays the “FEELING” button: Press this button can be used to set the feeling function. The LCD shows the actual room temperature when the function set and it shows the setting temperature when the function cancelled. This function is invalid when the appliance at the Fan mode.

  6. “DUST” button
    This button is invalidation.

  7. “TIMER” button
    Setting the “ON” timer time:

    • a. When remote controller is at off state, press “TIMER” button, the LCD displays “TIMER ON” and the timer time, the range of setting time is 0.5h to 24h.

    • b. You can press the “ ” or “ ” button to adjust the timer time, each touch will be set time to increase or reduce 0.5h before 10 hours ago, after ten hours will be set time to increase or reduce 1h per pressing, to enables your required timer.

    • c. Press the “TIMER” button again, to set the timer on function.

    • d. You can set another function to insure the suitable state after air conditioner turn on (including mode, temperature, swing, fan speed and etc). The LCD will displays all your setting and keep it, when the timer reach to the set time, the air conditioner will be working according to your set automatically.
      Setting the “OFF” timer time:

    • a. When remote controller is at on state, press “TIMER” button, the LCD displays “TIMER OFF” and the timer time, the range of setting time is 0.5h to 24h.

    • b. You can press the “ ” or “ ” button to adjust the timer time, each touch will be set time to increase or reduce 0.5h before 10 hours ago, after ten hours will be set time to increase or reduce 1h per pressing, to enables your required timer.

    • c. Press “TIMER” button again, to set the timer off function.

  8. “SCREEN” button You can let the LCD displays working or not by pressing this button.

  9. “ ” or ” ” button Press the “+” or “-” button, and you can set the temperature range from 16°C to 32°C, Display will change as you touch the button.

  10. “CLEAN” button
    a. When the remote controller is at the off state, press the “clean” button, the wind guiding bars turn to initial postions for cooling, the A/C runs “clean” function with max duration 35mins. The purpose of its function is to clean dust on evaporator and dry the inside water of the evaporator and to prevent the evaporator going moldy due to water deposition and boasting strange smell.
    b. After setting “clean” function, press the “clean” button again to cancel the “clean” function or press “ON/OFF” button to cancel “clean” function and start A/C.
    c. The clean function will not work after 35 minutes running without any operation. Note: “clean” function can be set in parallel with “time start” function; in this case, “time start” function will be executed after “clean” function.

  11. “MODE” button
    Which enables you to select different operation mode, after each pressing, the operation mode will be changed. It shows in the following display.
    AUTO→COOL-DRY-HEAT-FAN→AUTO
    Remark: cold wind type has no heating function.

  12. “SLEEP” button

  13. Press the SLEEP button, the sleeping indicator light of indoor unit flashes on.

  14. after the setting of sleeping mode, the cooling operation enables the set temperature to increase 1°C after 1hour and another 1°C automatically after 1 hour.

  15. after the setting of sleeping mode, the heating operation enables the set temperature to drop 2°C after 1 hour and another 2°C automatically after 1 hour.
    4. the air-conditioner runs in sleeping mode for 7 hours and stops automatically. Remark: press the MODE or ON/OFF button, the remote controller clears sleeping mode away.

  16. “SWING” button
    Press this button, the horizontal wind direction vanes can rotate automatically, when you have the desired vertical wind direction, press it again, the horizontal wind direction vanes will be stopped at the situation of your choice.

  17. “HEALTH” button
    Press this button, you can turn on or off the health function.

  18. “FUNGUSPROOF” button
    This A/C has a special dry and anti-mold function which has “yes” or “no” two selections. This function is controlled by the remote controller under cooling, dry and auto (cooling and dry) modes, the horizontal wind guiding bars are at the initial position for cooling. The A/C runs under heating mode(the cooling only A/C only runs under fan mode), the internal fan runs for three minutes with weak wind before stop. The purpose of this function is to dry the inside of the evaporator and to prevent the evaporator from going moldy due to water deposition and thus dispersing strange smell.

Note:

  1. This function has not been set in the factory. You may freely set and cancel this function. The setting method is: under “off” status of the A/C and the remote controller, point the remote controller toward the A/C and continuously press the “FUNGUSPROOF” pushbutton for one time, the buzzer keeps beeping five times again after five times beeps, indicating that this function is ready. In case this function has been set, unless the whole A/C is powered off or the function is manually cancelled, the A/C then has this function as a default;
  2. To cancel the function: 1. Power off the whole A/C; 2. Under “off” status of the A/C and the remote controller, point the remote controller toward the A/C and continuously press the “FUNGUSPROOF” pushbutton for one time, the buzzer keep beeps three times again after five times beeps, indicating that this function has been canceled;
  3. When this function is on, it is suggested not to restart the A/C before it is completely stopped;
  4. This function will not run in case of time stop or sleep stop.

Usage

Fix batteries

Premium-PAC-Series-Air-Conditioner-fig \(15\)

  1. Slide open the cover according to the direction indicated by an arrowhead.
  2. Put into two brand new batteries (7#), and position the batteries to right electric poles (+&-).
  3. Put back the cover.

Automatic operation mode

  1. Press the MODE button, select the automatic operation mode.
  2. Press the SPEED button, you can select fan speed. the air-conditioner starts to operate the automatic mode. Press the button again, the air-conditioner stops.

Cooling/Heating operation mode (cold wind type has no heating function)

  1. Press the MODE button, select the Cooling or Heating operation mode.
  2. Press the “ ” or “ ” button, set the temperature, temperature can be set at 1C difference range from 16-32°C.
  3. Press the SPEED button, you can select fan speed.
  4. Press ear sultan, the operation dictator is To, the air-conditioner starts to operate the automatic mode. Press the button again, the air-conditioner stops.

Fan operation mode

  1. Press the MODE button, and select the Cooling or Heating operation mode.
  2. Press the SPEED button, you can select fan speed. You can select fan speed from LOW, MID, HIGH.
  3. Press the ON/OFF button, the operation indicator is on, the air-conditioner starts to operate the automatic mode. Press the button again, the air-conditioner stops. Remark: In the circulation operation mode, to set the temperature is ineffective.

Drying operation mode

  1. Press the MODE button, and select the Dry operation mode.
  2. Press the “ ” or “ ” button, set the temperature, temperature can be set at 1°C difference range from 16-32°C.
  3. Press the SPEED button, you can select fan speed. You can select fan speed from LOW, MID, HIGH, AUTO.
  4. Press the ON/OFF button, the operation indicator is on, the air-conditioner starts to operate the automatic mode. Press the button again, the air-conditioner stops.

Night Luminous Function of Remote Controller(Only the remote controller with this function can be used) For your convenient use of the remote controller in the darkness without any lighting, this remote controller has blue background light and luminous pushbuttons. Function at you press on any of the pushbuttons, the background light will immediately release soft light so that you are easy to operate the remote controller. If you do not operate the controller within 10 seconds, the background light will automatically disappear.

Note:

All the figures above are the displays after being initially electrified or re-electrified after powering off. In actual operations, the remote controller screen displays related items only.

Attention

  1. Aim the remote controller towards the receiver on the air- conditioner.
  2. The remote controller should be within 8 meters away from the receiver.
  3. No obstacles between the remote controller and the receiver.
  4. Do not drop or throw the remote controller.
  5. Do not put the remote controller under the forceful sunrays or heating facilities and other heating sources.
  6. Use two 7# batteries, do not use the electric batteries.
  7. Take the batteries out of the remote controller before stop its use for long.
  8. When the noise of the transmitting signal can’t be heard indoor unit or the transmission symbol on the display screen doesn’t flare, batteries need be replaced.
  9. If a reset phenomenon occurs on pressing the button of the remote controller, the electric quantity is deficient and new batteries need to be substituted.
  10. The waste battery should be disposed properly.

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>