AVIGILON OP-CR-ACC Access Control Core
Specifications
- Model: OP-CR-ACC
- Includes: Access Control Core, Power cable, Bracket and push-in fasteners, Tamper sensor wire (optional)
- Ports: 1 USB, 2 Ethernet
- Indicators: Status LED, Power LED
Product Usage Instructions
Installing
Install the Access Control Core in the enclosure using the included bracket:
- Unscrew the retaining screw, slide the device into the bracket, and tighten.
- Secure the bracket to the enclosure using washers and fasteners.
Wiring
Connect the Access Control Core to an Ethernet cable with internet access.
Provisioning
- Create an Avigilon Alta Control Center user account.
- Follow the steps in Alta Control Center to create an organization and add devices.
- Connect devices to an organization using the Avigilon Alta Access app.
- Connect the Access Control Core to an Avigilon expansion board using the USB cable.
- Connect the Access Control Core to a power supply using the included power cable.
- Optional: Monitor tamper events by attaching the tamper wire to the enclosure and plug into the Access Control Core.
FAQ
What do the different Status LED indicators mean?
The Status LED indicators signify various states of operation:
- Solid green: Operating as expected
- Solid cyan: Booting up
- Solid yellow: Restoring software
- Blinking yellow: Updating software
- Solid blue: Not provisioned
- Solid purple: Connected to Avigilon Alta Access app
- Blinking purple: Ready to connect to Avigilon Alta Access app
- Blinking red: Not connected to internet
- Solid red: Error, see Alta Control Center on your computer
How should I address potential FCC Compliance concerns?
To ensure FCC compliance, refrain from making changes or modifications not approved by the responsible party. Maintain a minimum distance of 20 centimeters between the device and your body for safe operation.
For More Information
Scan the following QR codes:
Overview
Status LED Indicator
What’s Included
Installing
- Install the Access Control Core in the enclosure using the included bracket.
Wiring
- Connect the Access Control Core to an Ethernet cable with internet access.
- Connect the Access Control Core to an Avigilon expansion board (not included) using the USB cable.
- Connect the Access Control Core to a power supply using the included power cable.
Warning: Do not apply power during wiring. Ensure the power supply is unplugged until all wiring is complete.
- Optional. To monitor tamper events, attach the included tamper wire to the tamper switch on the enclosure and plug into the Access Control Core.
Provisioning
-
Before you start, you’ll need an Avigilon Alta Control Center user account. To create and register for an account, visit:
control.openpath.com/login
control.eu.openpath.com/login -
Follow the steps in Alta Control Center to create an organization and add devices.
-
To connect devices to an organization, use the Avigilon Alta Access app.
- In the app, tap Devices at the bottom.
- Tap Scan for Devices or button, and follow the instructions.
App Store® and the Apple logo® are trademarks of Apple Inc. Google Play and the Google Play logo are trademarks of Google LLC.
FCC Compliance
Any changes or modifications not expressly approved by the party responsible
for compliance could void your authority to operate the equipment.
This device complies with Part 15 of the FCC Rules. Operation is subject to
the following two conditions: (1) This device may not cause interference; and
(2) This device must accept any interference, including interference that may
cause undesired operation of the device.
Note: This equipment has been tested and found to comply with the limits
for a Class A digital device, pursuant to Part 15 of the FCC Rules. These
limits are designed to provide reasonable protection against harmful
interference when the equipment is operated in a commercial environment. This
equipment generates, uses, and can radiate radio frequency energy, and if it
is not installed and used in accordance with the instruction manual, it may
cause harmful interference to radio communications. Operation of this
equipment in a residential area is likely to cause harmful interference, in
which case the user will be required to correct the interference at his own
expense.
This equipment complies with FCC RF radiation exposure limits set forth for an
uncontrolled environment This equipment should be installed and operated with
minimum distance of 20 centimeters between the radiator and your body.
Industry Canada Notice and Marking
This device complies with the ISED radiation exposure limit set forth for an
uncontrolled environment. This device should be installed and operated with
minimum distance 20cm between the radiator & your body. This transmitter must
not be co-located or operating in conjunction with any other antenna or
transmitter.
This device contains licence-exempt transmitter(s) that comply with
Innovation, Science and Economic Development Canada’s license-exempt RSS(s).
Operation is subject to the following two conditions:
(1) this device may not cause interference, and 2) this device must accept any
interference, including interference that may cause undesired operation of the
device.
The frequency and the maximum transmitted power in EU is listed below.
Bluetooth LE (2402-2480MHz): 2 dBm
Certifications
CE, IC, FCC, UKCA, ANATEL, RoHS
QuickStartGuide-OP-CR-ACC-Rev4
© 2024, Avigilon Corporation. All rights reserved. AVIGILON, the AVIGILON
logos and AVIGILON ALTA are trademarks or registered trademarks of Avigilon
Corporation. HID and HID Mercury are trademarks or registered trademarks of
HID Global, ASSA ABLOY AB, or its affiliate(s) in the US and other countries.
All other trademarks are the property of their respective owners. Unless
stated explicitly and in writing, no license is granted with respect to any
copyright, industrial design, trademark, patent or other intellectual property
rights of Avigilon Corporation or its licensors.
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>