SARGENT 6300 Large Format Interchangeable Cores Cylinder Installation Guide

October 30, 2023
SARGENT

Installation Instructions
6300, 11-6300 & 10-6300
LFIC (Removable Core) Cylinders

Installation Notes

The 6300 series LFIC (Removable Core) uses a control key whose bittings match the Top Master Key of the key system in positions 1, 2, 5 and 6. The control bittings in positions 3 and 4 are selected from the Key Bitting Array of the master key system.
This method signifi cantly reduces the bittings available in the Key Bitting Array of any Top Master Key. Increasing the levels in the master keying system and cross keying also has a signifi cant impact on the yield of keys at each selected level.
The chamber stack value for the 6300 series LFIC (removable core) is normally calculated by using a stack value of 15 in positions 1, 2, 5, and 6. This is the total value of the bottom pins, master splits and driver pins that would be required to pin the core (based on the keying levels).
In chambers 3 and 4 of the 6300 series LFIC (removable core), the stack value is 20. This is done to allow the control key to achieve a shear line in chambers 3 and 4 of the control sleeve.

Important: Cylinders master keyed at the factory use hollow drivers and SARGENT recommends their continued use. Hollow drivers must be used in chambers 3 and 4. A different spring is used in conjunction with the hollow drivers.
These special drivers and springs are included in a special pinning kit 437 RC. The drivers and springs  can also be ordered individually. The machined or hollow end of the hollow driver faces towards thespring.

  • 65-6300 or 1 bitted cylinders are supplied for fi eld keying and are provided with 2 key blanks
  • 65-6300 cylinders are shipped without pins and springs
  • 1 bitted cylinders supplied for fi eld keying have pins loaded only in chambers 3 and 4
  • 111111 bitted cylinders utilize a control key cut 113511

Installation Instructions

A Remove the retaining ring, then remove the barrel from the cylinder body and sleeve or load from the top using the Top Loading Kit (P/N 436-1).SARGENT
6300 Large Format Interchangeable Cores Cylinder

b With sleeve positioned correctly in cylinder body (as shown above), load barrel and cylinder body. Use the template on page 4 to determine pinning.
Note: The SARGENT rekeying kit 437 RC contains the hollow drivers and springs that must be used in chambers 3 and 4 for factory keyed cores prior to January 2009.

c  Finish assembling by installing the retaining ring to barrel. The barrel is designed to hold the ring in position.

Important: The retaining ring must clear keyway.SARGENT 6300 Large
Format Interchangeable Cores Cylinder - clear keyway

Template

The following is an example showing how to select the pin segments for each chamber of the SARGENT 6300 series LFIC (removable core). Use this as a template for calculating the correct pin loads.

List of Operating Keys

List of Operating Keys Sample  KEY SYMBOLS
 List Day Changes/MK’s GM’s etc GM “A”
 Do Not list bitting of MK “AA”
 the Control key in this area. CK “AA1”

SARGENT 6300 Large Format Interchangeable Cores Cylinder - clear
keyway3

2 Calculate Bottom Pins and Master Splits
Find correct size for Bottom and Master Splits from operating key’s list

(a) BOTTOM PINS
(Smallest number in each chamber)
(b) MASTER SPLITS *
(Difference in smallest and largest number in each chamber)SARGENT 6300
Large Format Interchangeable Cores Cylinder - clear keyway
4

3 Calculate Value of Control Splits
3.3 CONTROL KEY BITTING
(3.1) A number 8 appears on this line in positions 3 and 4
(3.2) Insert bitting of positions 3 and 4 of control key.
and add to number 8’s in positions 3 and 4
3.3 CONTROL PIN FACTOR
(3.4) Subtract largest number in positions 3 and 4 from list of operating keys from control pin factor
(c) CONTROL SPLITS SARGENT 6300 Large Format
Interchangeable Cores Cylinder - clear keyway 5 4 Calculate Top or Driver Pin
(Total Stack Value)
(4.1) Add value of: (a) Bottom Pins, + (b) Master Splits  + (c) Control Splits).Enter total here.
(4.2) Subtract total from TOTAL STACK VALUE above.
(d) (4.3) Enter values on this line. DRIVER SPLITS (Master Splits)SARGENT
6300 Large Format Interchangeable Cores Cylinder - clear keyway
65 P inning Assembly Matrix

Example of pinning matrix for above key bittings.
Transfer Values labeled (d) Driver Splits
(a), (b), (c), (d) from items
(c) Control Splits
2, 3, and 4 above. (b) Master Splits
(a) Bottom Pins
Stack Total
Limits
SARGENT 6300 Large Format Interchangeable Cores Cylinder - clear keyway
7

**WARNING**
This product can expose you to lead which is known to the state of  California to cause cancer and birthdefects or other reproductive harm. For more information go to  www.P65warnings.ca.gov.

WARNING
Attention Installer: Improper
installation may result in damage to the product and void the factory warranty.

Experince a safer and more open worid
1-800-727-5477
www.sargentlock.com
Copyright © 2009, 2011, 2016, 2022, SARGENT Manufacturing Company. All rights reserved.
Reproduction in whole or in part
without the express written permission of SARGENT Manufacturing Company is prohibited.
Patent pending and/or patent
www.assaabloydss.com/patents.

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

SARGENT User Manuals

Related Manuals