better bathrooms Arissa Basin Mixer User Manual
- July 8, 2024
- Better Bathrooms
Table of Contents
better bathrooms Arissa Basin Mixer
Product Information
Specifications
- SKU Number: ARIMB001/ARIBB001/ARICH001/ARIMW009/ARIVRG001/AR2TCBM-2
- Minimum Working Pressure: 1.5 bar
- Maximum Working Pressure: 5 bar
Product Usage Instructions
Product
- Arissa Mini Cloakroom Basin Mixer Tap – ARIMB001, ARIBB001, ARICH001, ARIMW009, ARIVRG001, AR2TCBM-2
- Arissa Mono Basin Mixer Tap – ARIMB002, ARIBB002, ARICH002, ARIMW001, ARIVRG002, AR2TMBM
- Arissa Mono High Rise Basin Mixer Tap – ARIMB003, ARIBB003, ARICH003, AR2TTALLBM
- Single-person assembly
- Tools required
- We always recommend using professional tradespeople to install your product
Parts / Diagrams
Dimensions
Tools Required
- Screwdriver
Congratulations on your purchase
Welcome to our growing gang of savvy shoppers We’re on a mission to bring you
extraordinary bathroom products, for less. From modern to traditional style
ceramics, plus the gorgeous fixtures, fittings and furniture to match. So, you
can fall in love with your space every single day. As one of the UK’s largest
independent bathroom stores, we’ve received countless awards; including the
National Business Awards UK, the Digital Entrepreneur Awards and being placed
on The Sunday Times Fast Track 100. We hope your new product goes above and
beyond your expectations.
However, should any problems occur, please:
- log in to your account and contact our customer services team via your self-serve portal – betterbathrooms.com/CustomerAccount/Login
- contact us via betterbathrooms.com/content/contact-us
Installation
- Install the flexible hoses with inlets in the body(if the hoses were not preassembled). Remove the Screws, Locknut, Metal gasket, Rubber Washer from the mixer body . The flexible hoses are pre-assembled with the body from the factory.
- Ensure the o-ring is fitted between the base and basin/top. From above basin, push the inlet hoses through the hole on basin and position correctly. Do not allow the hoses to be kinked or twisted
- From underneath basin, secure mixer body by placing Rubber Washer, Metal gasket onto the leg, followed by fixing Locknut and screws. Tighten the Locknut and screws by screwdriver until mixer is secure, do not overtighten as this could crack the ceramic
- Connect the hot and cold flexible hoses to the isolation valves (not included), hot on the left, cold on the right. Turn on water supply and check for leaks.
Operation
By lifting the Lever Handle upwards, the valve will be activated. Water flow will increase by continuing to lift up the Lever Handle. By rotating the Lever Handle counter-clockwise, the water temperature will decrease. By rotating the Lever Handle clockwise, the water temperature will increase.
Important information
- Please read these instructions thoroughly and retain for future reference
- Installation must be carried out in compliance with The Water Fittings Regulations and Scottish Water Byelaws.
- The system must be flushed prior to installation.
SKU Number| Minimum working pressure| Maximum working pressure
---|---|---
ARIMB001/ARIBB001/ARICH001/ ARIMW009/ARIVRG001/ AR2TCBM-2|
1.5 bar
|
5 bar
ARIMB002/ ARIBB002/ ARICH002/ ARIMW001/ ARIVRG002/ AR2TMBM/ ARIMB003/ARIBB003/ARICH003/ AR2TTALLBM|
1 bar
|
5 bar
- Pressures must be equal for optimum performance
- Please do not connect hot and cold water supply lines in reverse. This could result in hot water flowing from cold line and cause scalding.
- The feed-water temperature of water shall not exceed 85°C. Exceeding 85°may cause scalding, the service life of faucets might be shortened, or the faucet might be damaged.
- After installation, please make sure the faucet is securely mounted and checked for leaks.
Troubleshooting
Issues | Inspection Item |
---|---|
Mini Cloakroom Basin Mixer Tap | Mono Basin Mixer Tap |
Poor water flow | • Is the mixer cartridge(4) free from debris |
• Is there blockage within the filter mesh on aerator(6)
• Is the flexible hose(12) kinked or twisted
• Was the system flushed prior to installation
| • Is the mixer cartridge(3) free from debris
• Is there blockage within the filter mesh on aerator(5)
• Is the flexible hose(11) kinked or twisted
• Was the system flushed prior to installation
Water leak| • Is the locknut(3) on top of cartridge fully tightened
• Is there damage or dirt within the O-rings of the cartridge(4)
• Is there damage or dirt with the rubber washer or O-ring of the aerator(6)
• Is the housing of aerator(6) fully tighten
• Is there damage with the rubber washer(7)
• Is there damage within the rubber washer inside the nuts of flexible hoses(12)
• Is there damage with the O- rings on the flexible hoses(12)
| • Is the locknut(2) on top of cartridge fully tightened
• Is there damage or dirt within the O-rings of the cartridge(3)
• Is there damage or dirt with the rubber washer or O-ring of the aerator(5)
• Is the housing of aerator(5) fully tighten
• Is there damage with the rubber washer(6)
• Is there damage within the rubber washer inside the nuts of flexible hoses(11)
• Is there damage with the O- rings on the flexible hoses(11)
Handle loose| • Is the screw inside the handle
(1) fully tightened
| • Is the screw inside the handle
(1) fully tightened
Body loose| • Are the locknut(10) and screw(11) underneath fully tightened| Are the locknut(9) and screw(10) underneath fully tightened
Maintenance
Replacement of Cartridge
Replacement of Aerator
Cleaning
To maintain the surface of your product, wipe with a clean damp cloth and
wipe dry, do not use any abrasive cleaning agents or materials. If any harsh
chemicals come into contact with the surface of the product, rinse and wipe
clean immediately.
For more information
- visit betterbathrooms.com
- email customerservices@buyitdirect.co.uk
- call 03303903062
- write to Trident Business Park, Neptune Way, Huddersfield, HD2 1UA
Frequently Asked Questions
-
Q: What should I do if I encounter any problems during installation?
A: If any problems occur during installation, please contact us via betterbathrooms.com/content/contact-us for assistance. -
Q: Can I connect hot and cold water supply lines in reverse?
A: Please do not connect hot and cold water supply lines in reverse as this could result in issues. -
Q: What are the recommended working pressures for the different SKU numbers?
A: The recommended minimum working pressure for ARIMB001/ARIBB001/ARICH001/ARIMW009/ARIVRG001/AR2TCBM-2 is 1.5 bar, while for ARIMB002/ARIBB002/ARICH002/ARIMW001/ARIVRG002/AR2TMBM/ARIMB003/ARIBB003/ARICH003/AR2TTALLBM is 1 bar. The maximum working pressure for both sets is 5 bar.