GENERAL WARNINGS

  • Read the instructions carefully before starting the installation and proceed as specified by the manufacturer.
  • Installation, programming, commissioning and maintenance of the product must only be performed by qualified technicians who have been properly trained in compliance with current standards, including health and safety and packaging disposal regulations.
  • Control boards can be seriously damaged by electrostatic discharges: if you need to handle them, wear suitable antistatic clothing and footwear or at least make sure you have removed any residual charge beforehand by tapping your fingertips on a metal surface connected to the earthing system (e.g. the chassis of a household appliance).
  • Before performing any cleaning or maintenance operation, disconnect the power supply to the device.
  • The device must only be used for the purpose for which it was explicitly designed.
  • The manufacturer declines all liability for any damage as a result of impro-per, incorrect or unreasonable use.

The data and information provided in this manual are subject to change at any time without prior notice.
Measurements, unless otherwise indicated, are in millimeters.

DESCRIPTION

Video entry system power supply for X1 systems.

Technical data

CAME VA-01-Video-Entry-System-Power-Supply- \(2\)

Calculation of current draws

  • a Current draw of individual entry panels at rest
  • b With camera on
  • c With electric lock ‘active’

CAME VA-01-Video-Entry-System-Power-Supply- \(3\)\ CAME VA-01-Video-Entry-System-Power-Supply- \(4\)

Main components

CAME VA-01-Video-Entry-System-Power-Supply-
\(6\)

(*) The device is protected against overloads and short circuits. CAME VA-01
-Video-Entry-System-Power-Supply- \(7\) CAME VA-01-Video-Entry-System-Power-Supply- \(8\)

Dimensions

INSTALLATION

The device, with a connection for DIN rails, can be installed without terminal covers in closed cabinet or on the wall with a view to applying terminal covers.
Always position horizontally, as shown. If in a cabinet, check for air grilles.CAME VA-01-Video-Entry-System-Power-Supply-
\(10\)

SAMPLE SYSTEMS WITH VA/01

A multi-family system with a 4 indoor receivers.

CAME VA-01-Video-Entry-System-Power-Supply- \(11\)

SAMPLE SYSTEMS WITH VA/01
Multi-family system with a 3 entry panels. CAME VA-01-Video-Entry-System-
Power-Supply- \(12\)

SAMPLE SYSTEMS WITH VA/01
Multi-family system with a 2 entry panel and b 4 separate video cameras. CAME VA-01-Video-Entry-System-Power-Supply- \(13\)

PROGRAMMING INTERCOM GROUPS

The intercom group must be programmed after you have assigned the type of call button or call code to all the indoor receivers (see Programming Manual for the DC/01-DVC/01-DC/01ME-DVC/01ME entry panels, code FB00232).

Activating an intercom group
Press PROG ① on the power supply for at least 25 seconds until LED DL2 ② flashes quickly.
Then set the RFID PROG jumper ③ to the “+” position.

Go to an indoor receiver and press the button with which you wish to call: a beep will indicate successful activation.
Repeat the same steps on the indoor receivers to be added to the intercom group (max 4 per group).

To end the procedure, press ① and set the jumper ② to the neutral position.
If no action is performed, the procedure will automatically end after 30 minutes.

Once an indoor receiver has been included in an intercom group through the assignment of a call button, it can no longer be excluded from the group.
In order to change the call button for an indoor receiver that has already been programmed as an intercom, or to add new indoor receivers to the group, simply repeat the sequence of steps described.

Disabling an intercom group

Press PROG ① on the power supply for at least 25 seconds until LED DL2 ② flashes quickly.
Then set the RFID PROG jumper ③ to the “-” position for at least 20 seconds.
To end the procedure, press ① and set the jumper ② to the neutral position.CAME VA-01-Video-Entry-System-Power-Supply-
\(17\)

VA/01 allows a single intercom group.
If you need to add other intercom groups, it is necessary to install a VSE/310 selector downstream from the video distributor for each group. It is not possible to configure one intercom group with VA/01 and others with VSE/301 at the same time. CAME VA-01-Video-Entry-System-Power-Supply-
\(18\)

PROGRAMMING RECORD

CAME VA-01-Video-Entry-System-Power-Supply- \(19\)
CAME VA-01-Video-Entry-System-Power-Supply- \(20\) CAME VA-01-Video-Entry-System-Power-Supply- \(21\) CAME VA-01-Video-Entry-System-Power-Supply- \(22\) CAME VA-01-Video-Entry-System-Power-Supply- \(23\)

DISMANTLING AND DISPOSAL

CAME S.p.A. implements an EN ISO 14001 certified and compliant Environmental Management System at its plants, to ensure environmental protection.
Please continue our efforts to protect the environment, something that CAME considers to be one of the foundations in developing its business and market strategies, simply by observing brief recommendations as regards disposal:

DISPOSAL OF PACKAGING
Packaging components (cardboard, plastic etc.) can be disposed of together with normal household waste without any difficulty, by simply separating the different types of waste and recycling them.
Before proceeding, it is always advisable to check specific regulations in force in the place of installation.

DISPOSAL OF THE PRODUCT

  • Our products are made with different materials. Most of them (aluminum, plastic, iron, electrical cables) can be disposed of together with normal household waste. They can be recycled if collected, sorted and sent to authorized Centres.
  • They should therefore be removed and handed over to companies authorized to recover and recycle them.
  • Before proceeding, it is always advisable to check specific regulations in force in the place of disposal.

DECLARATION OF CONFORMITY

Declaration. CAME S.p.A. declares that this device complies with the essential requirements and other relevant provisions established in Directive 2004/108/EC. The original can be requested.

  • Via Martiri Della Libertà, 15
  • 31030 Dosson di Casier Treviso – Italy
  • Via Cornia, 1/b – 1/c
  • 33079 Sesto al Reghena Pordenone – Italy

www.came.com

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals