CAME ATS-P5 Electric Gate Kit User Guide

June 4, 2024
CAME

CAME logo ATS-P5 Electric Gate Kit
User Guide

ATS-P5 kit
Complete kit for a pair of swing gates weighing
up to 400kg per leaf/max. width 5m
CAME ATS P5 Electric Gate KitTypical gate setup & geometry Gate motor manual release Kit wiring diagram Control panel guide & safety
TO BE READ IN CONJUNCTION WITH THE FULL

ATS-P5: KIT CONTENTS

CAME ATS P5 Electric Gate Kit - KIT CONTENTS

SAFETY INSTRUCTIONS

When correctly installed in compliance with installation instructions and adhering to all current electrical, mechanical, and manufacturer regulations, your automation system will provide a high degree of safety and problem-free operation.
CAME ATS P5 Electric Gate Kit - Fig Please take note of the following warnings that must be followed in order to prevent accidents during your gate operation:

  • Do not allow children to play near the gate.
  • Keep all remote control operating devices out of the reach of children.
  • Do not pass through the gate whilst in operation. Wait until they are fully open before passing through.
  • Do not stop unnecessarily when passing through the gate.
  • Keep feet away from the bottom of the gate during operation.
  • Do not operate the gate by remote control unless they are in view.
  • Do not attempt to block or interfere with the gate movement during operation.
  • Under no circumstances should you attempt to modify the gate automation system.
  • Ensure that your gate is serviced at 3 to 12-month intervals (dependent on the number of openings) by your installation/maintenance company.
  • Report any signs of malfunction to your installation/maintenance company immediately.
  • In the case of malfunction, isolate the power supply, release any additional locking mechanism, manually open the gate (see manual release instruction booklet) and call your installation/maintenance company.
  • If you are in any doubt regarding the operation of your gate, call your installation/maintenance company.

ATS: TYPICAL GATE SETUP

CAME ATS P5 Electric Gate Kit - GATE SETUP

  1. ATS Motor
  2. Control Panel
  3. Reception Antenna
  4. Flashing Light (optional)
  5. Selector Keypad (optional)
  6. Photocells (on the outside of gate posts)
  7. 2nd set of Photocells (optional)
  8. Mechanical End Stop (not supplied)
  9. Photocell column (optional accessory)

CONTROL PANEL

  • The control panel should be mounted in an accessible position and not directly behind the gates, to avoid a potential crushing hazard.
  • Use cable glands to connect the devices to the control panel. One of these must be used exclusively for the power supply cable.
  • All holes should be sealed to avoid ingression and maintain the IP54 protection rating.

Only a competent service provider should open the enclosure and adjust the settings.
PHOTOCELLS

  • The photocells are used in pairs, one transmitter, and one receiver.
  • They should be installed between 500-600mm from the ground, facing each other.
  • Power for the photocells is taken from the control panel 24v AC.
  • The maximum range of the photocell should always be observed.

When the photocell beam is broken, the control panel can be programmed on how to react. Please see the ‘Safety’ section for more information.

ATS50AGS: GEOMETRY

Preliminary checks

  1. Check that the gate structure is sturdy enough, the hinges work efficiently, and that there is no friction between the fixed and moving parts
  2. Make sure that measurement C does not exceed the value shown in the reference table
  3. Make sure that you have fitted opening and closing mechanical gate stops

Side hung gate GEOMETRY (5m)

Opening| A (mm)| B (mm)| E (mm)| F (mm)| C max. (mm)
---|---|---|---|---|---
90°| 200| 200| 1030| 1430| 150
90°| 200| 270| 1030| 1510| 200
120°| 200| 140| 1030| 1460| 70

CAME ATS P5 Electric Gate Kit - Fig 2

  • The greater the motor angle, the greater the opening speed and the slower the gear motor’s thrust.
  • The smaller the motor angle, the slower the opening speed and the greater the gear motor’s thrust.

OUTward OPENING gates
For outward opening gate geometry please refer to the full Installation Manual.

  • Lubricate the bushing and fit it into one of the holes on the post bracket.
  • The bracket holes allow the opening angle to be changed.

CAME ATS P5 Electric Gate Kit - Fig 3

ATS: MANUAL RELEASE

The ATS telescopic swing gate operators have a manual release lock beneath a hatch on the top of the motors.
To manually release the gates:

  1. Open the hatch covering lock A.
  2. Insert the release key into lock B and turn clockwise C.
  3. With your other hand firmly open the gate. The gate should be manually released. Now fully open the gate carefully at the same speed as the automatic operator.
  4. To re-engage, close the gate and turn the key back to its original position  D . Attempt to manually move the gate to ensure it is fully engaged.
    CAME ATS P5 Electric Gate Kit - Fig 4

ALWAYS isolate the power supply as instructed by your installer (even in a power cut).
Release any additional locking device fitted to the gate (eg. electric lock etc).
Basic Maintenance: Hints & Tips

  • Open manual release cover & spray locking mechanism with suitable penetrating lubricant.
  • Lubricate gate hinges.
  • Manually release the gates at least once per month.

ATS-P5: wiring diagram

CAME ATS P5 Electric Gate Kit - Control PanelATS50AGS
Gate motors
Cable/length
1m – 20m = 3 Core 1.5mm
20m – 30m = 3 Core 2.5mm

ZA3P: QUICK START GUIDE

Important!
The installation must be carried out by skilled and qualified personnel

Potentiometers Dip Switches

Ensure the wiring is complete (refer to the wiring diagram) & any required physical stops are set before commencing with programming

  1. Power on the control panel.

  2. Disable total stop – Permanent link wire between terminals 1 & 2.

  3. If no safety device has been connected to the C1 terminal then disable the safety input C1 – Permanent link wire between terminal 2 & C1.

  4. Disable safety input CX – Dip switch 8 on.

  5. Set all other dip switches off.

  6. Check the motor directions 
    Enable maintained action – Dip switch 6 on.
    Hold a wire between terminals 2 & 3.
    The gates should open, if not reverse the motor cables relating to the motor that is closing
    for motor 2 (Connections X, Y)
    for motor 1 (connections U, V)
    Disable maintained action – Dip switch 6 off

  7. Set the ATS microswitch end stops
    Unlock both motors on the manual release
    Adjust the TL potentiometer to the maximum clockwise position.
    Set both gates to their closed positions
    For each gate motor complete the following steps
    Send a closing command pulse using a link wire between terminals 2 & 4.
    While the motor is running, turn the rod marked C anticlockwise until the motor stops running.
    Set both gates to their open positions
    For each motor complete the following steps
    Send an opening command pulse using a link wire between terminals 2 & 3.
    While the motor is running, turn the rod marked A clockwise until the motor stops running.
    CAME ATS P5 Electric Gate Kit - Fig 5 Note. 20 complete turns of the rod are equal to 10mm of movement of the micro switch. By default, the motor run time is set to 120s, if the motor times out before the micro switch has been reached an additional command will need to be sent to start the motor running again so that the micro switch setup can be completed.

  8. Set the TRM2 potentiometer all the way to minus (Anticlockwise).

  9. Adjust the TL potentiometer to the 4 O’clock position

  10. Check the gate operation by pulsing across connections 2 & 4, the gate will close.

Safety inputs should now be configured and the gate force tested as required.
Please refer to the full manual to complete the commissioning.
Should the gates not operate as suggested above, call the CAME helpline at 0115 921 0430 for technical support.

ZA3P: transmitters

Ensure the AF card is fitted (refer to the wiring diagram).
CAME ATS P5 Electric Gate Kit - diagram

Add a transmitter button

  1. Press and hold the CH1 button, the PROG. The LED starts fl ashing rapidly.

  2. While keeping the CH1 button held down press and release a button on a transmitter
    The PROG. The LED goes solid to signal the successful saving of the code.

  3. Release the CH1 key.
    A maximum of 25 individual buttons can be saved.

Remove all transmitters
1. Press and hold the CH1 and CH2 buttons simultaneously until the PROG. LED stays lit All previously saved transmitter buttons will be removed from the memory of the control board
Should the transmitter not operate as suggested above, call the CAME helpline at 0115 921 0430 for technical support.

ZA3P: SAFETY

SAFETY INPUTS
FUNCTIONS > C1 Input, CX Input
C1 REOPENING DURING CLOSING

  • When the automation is in its closing cycle and the safety circuit is triggered the automation will stop and reverse its motion until it reaches its fully open position again.
  • If the auto-closing option is enabled and the safety is no longer triggered the auto-closing countdown will commence, once completed the automation will start the closing cycle again.
  • If the auto-closing option is not enabled the automation will return to the fully open position awaiting another activation from a command device.

CX RECLOSING DURING OPENING

  • When the automation is in its opening cycle and the safety circuit is triggered the automation will stop and reverse its motion until it reaches its fully closed position again.
  • Once the automation has reached the fully closed position it will require another activation from a command device to restart.

OR
CX PARTIAL STOP

  • When the automation is in its opening cycle and the safety circuit is triggered the automation will stop.
  • If the auto-closing option is enabled and the safety is no longer triggered the auto-closing countdown will commence, once completed the automation will start closing the device.

The above sequence will be attempted 3 times before the automation is halted, the automation will then require activation from a command device to restart.
For more kit accessories please contact Sales on 0115 9210 430
If during the reverse motion a diff erent safety is triggered the automation will perform the appropriate action for the new triggered safety, should multiple safeties be triggered at the same time the automation will be halted at its current position?

ATS-P5: ACCESSORIES

| Code(s)| Description
---|---|---
RADIO KEYPAD SELECTORS
| 806SL-0170| SELT1W4G – Surface-mounted, 433.92 MHz radio-frequency keypad selector, 12-keys, with blue backlighting. 25 savable codes and passwords to access the programming mode. Settable in Rolling Code or Fixed Code mode. RAL7024 Grey color.
806SL-0180| SELT1W8G – Surface-mounted, 868.35 MHz radio-frequency keypad selector, 12-keys, with blue backlighting. 25 savable codes and passwords to access the programming mode. Settable in Rolling Code or Fixed Code mode. RAL7024 Grey color.
| 001AF868| Plug-in 868.35 MHz radio frequency control card.
Required for 806SL-0180.
BLUETOOTH SELECTORS
| 806SL-0210| SELB1SDG1 – Surface-mounted with blue backlighting, for 15 users. RAL7024 Grey color.
806SL-0240| SELB1SDG2 – Surface-mounted with blue backlighting, for 50 users. RAL7024 Grey color.
806SL-0250| SELB1SDG3 – Surface-mounted with blue backlighting, for 250 users. RAL7024 Grey color.
HARDWIRED KEYPAD SELECTORS
CAME ATS P5 Electric Gate Kit - SELECTORS 4| 806SL-0280| SELT1BDG – Surface-mounted 12-button Bus keypad with blue backlighting.
RAL7024 Grey color.
| 806SL-0290| SELT2BDG – Flush-mounted 12-button Bus keypad with blue backlighting.
RAL7024 Grey color.
CAME ATS P5 Electric Gate Kit - SELECTORS 6| 806SL-0370| S0002P – External, two-channel, 12 – 24 V AC – DC IP54 control card for keypads.
Required for 806SL-0280 and 806SL-0290.
TOP – FIXED CODE
| 8K06TS-002| TOPD4FXM – pack of 6 dual-frequency 4 button transmitters with self-learning function.
PHOTOCELLS
CAME ATS P5 Electric Gate Kit - PHOTOCELLS| Surface mounted. Synchronized beam, multiple pairs of photocells can be applied to the same system, even at double height and/or close to each other – with no interference issues (cross talk).
001DIR10| Pair of 12 – 24 V AC – DC outdoor photocells – range 10m.
001DIR20| Pair of 12 – 24 V AC – DC outdoor photocells – range 20m.
001DIR30| Pair of 12 – 24 V AC – DC outdoor photocells – range 30m.
PHOTOCELL column
| 001DIRL| Natural finish aluminum post. H = 500mm
| 001DIRLN| Black anodized aluminum post. H = 500mm
| 001DIRCG| Silver RAL9006, PVC post. H = 500mm

For more kit accessories please contact Sales on 0115 9210 430
CAME BPT – North
Unit 1B
Sills Road
Willow Farm Business Park
Castle Donington
DE74 2US
Tel: 0115 921 0430
CAME BPT – South
Liberta House
Maxted Road
Maylands Ind. Est.
Hemel Hempstead
Herts
HP2 7DX
Tel: 01442 230 800
CAME BPT – Ireland
Unit 9
The Westway Centre
Ballymount
Dublin 12
Tel: +353 (0)1 450 7442

CAME logo © ATSP5QS1021 – 2021 – EN
YOU MAY NOT EVEN PARTIALLY REPRODUCE THIS DOCUMENT CAME RESERVES THE RIGHT TO MAKE ANY CHANGES TO THIS DOCUMENT AT ANY TIME THE DATA AND INFORMATION SHOWN IN THIS CATALOGUE ARE SUBJECT TO CHANGE WITHOUT OBLIGATION TO GIVE PRIOR NOTICE BY CAME S.P.A, E&OE
CAME logo 2
CAME S.p.A.
Came cancelli automatic S.p.A. is certified for Quality and Environment
UNI EN ISO 9001
UNI EN ISO 14001
BS OHSAS 18001
CAME.COM/UK