GE APPLIANCES 06 Gas Dryer Installation Guide
- July 10, 2024
- GE Appliances
Table of Contents
GE APPLIANCES 06 Gas Dryer
Product Information
Specifications
- Model : GE PTDS650GM0WT
- Manufacturer : Appliance Factory Parts
- Gas Dryer
- Certification : DESIGN CERTIFIED
Product Usage Instructions
Before You Begin
Make sure to read the instructions completely and carefully before starting
the installation process.
Tools and Materials Required
- (x2) 10 Adjustable Wrenches
- 8 Pipe Wrench Slip Joint Pliers
- Level Flat Blade Screwdriver
- Various ducts, clamps, tape, gas line connectors, safety glasses, gloves, etc. as mentioned in the manual
Installation Steps
- Verify Your Gas Installation
- Prepare the Area and Exhaust for the Installation of a New Dryer
- Check and Ensure the Existing External Exhaust is Clean and Meets Specifications
- Remove Foam Shipping Pads
- Move the Dryer to the Desired Location
- Level Your Dryer
- Connect the Gas Supply and check for leaks
- Connect the External Exhaust
- Connect the Power Supply
- Check the Operation of Power Supply, Gas Connections, and Venting
- Place the Owner’s Manual and Installation Instructions in a Noticeable Location
Minimum Clearance Requirements
Ensure minimum clearance to combustible surfaces and for air openings as
specified in the manual for safe installation and service access.
Disconnecting Gas
Turn off the gas shut-off valve and replace old flexible gas connectors and
transition ducting material with new CSA(AGA) approved components to prevent
leaks and personal injury.
Removing Lint from Wall Exhaust Opening
Regularly clean lint from the wall exhaust opening to maintain proper
airflow and prevent blockages.
BEFORE YOU BEGIN
Read these instructions completely and carefully.
- IMPORTANT- Save these instructions for local inspector’s use.
- IMPORTANT – Observe all governing codes and ordinances.
- Note to Installer – Be sure to leave these instructions with the customer.
- Note to Customer – Keep these instructions with your Use and Care Book for future reference.
- Before the old dryer is removed from service or discarded, remove the dryer door.
- Inspect the dryer exhaust outlet and straighten the outlet walls if they are bent.
- Service information and the wiring diagram are located in the control console.
- Do not allow children on or in the appliance. Close supervision of children is necessary when the appliance is used near children.
- Install the dryer where the temperature is above 50°F for satisfactory operation of the dryer control system.
WARNING RISK OF FIRE
- To reduce the risk of severe injury or death, follow all installation instructions.
- Clothes dryer installation must be performed by a qualified installer. Install the clothes dryer according to these instructions and in accordance with local codes. In the absence of local codes, installation must comply with the National Fuel Gas Code, ANSIZ223.1/NFPA 54 or the Canadian Natural Gas and Propane Installation Code, CSA B149.1.
- California Safe Drinking Water and Toxic Enforcement Act. This act requires the governor of California to publish a list of substances known to the state to cause cancer, birth defects or other reproductive harm and requires businesses to warn customers of potential exposure to such substances. Gas appliances cancause minor exposure to four of these substances, namely benzene, carbon monoxide, formaldehyde and soot, caused primarily by the incomplete combustion of natural gas or LP fuels. Properly adjusted dryers will minimize incomplete combustion. Exposure to these substances can be minimized further by properly venting the dryer to the outdoors.
- This dryer must be exhausted to the outdoors.
- Use only 4” rigid metal ducting for exhausting the clothes dryer to the outdoors.
- DO NOT install a clothes dryer with flexible plastic ducting materials. If a flexible metal (semi-rigid or foil-type) duct is installed, it must be UL-listed and installed in accordance with the instructions found in “Connecting The Dryer To House Vent” on page 6 of this manual. Flexible venting materials are known to collapse, be easily crushed, and trap lint. These conditions will obstruct dryer airflow and increase the risk of fire.
- Do not install or store this appliance in any location where it could be exposed to water and or weather.
- Dryers installed in residential garages must be elevated 18” (46 cm) above the floor.
- Save these instructions. (Installers: Be sure to leave these instructions with the customer).
In the state of Massachusetts, installation must be performed by a qualified or licensed contractor, plumber, or gasfitter qualified or licensed by the state.
TOOLS YOU WILL NEED
MATERIALS YOU WILL NEED
-
Step 1
Verify Your Gas Installation (see section 2). -
Step 2
Prepare the Area and Exhaust for the Installation of New Dryer (see section 1). -
Step 3
Check and Insure the Existing External Exhaust is Clean (see section 1) and Meets AttachedInstallation Specifications (see section 6). -
Step 4
Remove the Foam Shipping Pads (see section 1). -
Step 5
Move the Dryer to the Desired Location. -
Step 6
Level Your Dryer (see section 8). -
Step 7
Connect the Gas Supply (see section 3) and check for leaks (see section 4). -
Step 8
Connect the External Exhaust (see section 7). -
Step 9
Connect the Power Supply (see section 5). -
Step 10
Check the Operation of the Power Supply, Gas Connections, and Venting. -
Step 11
Place the Owners Manual and the Installation Instructions in a Location Where They Will Be Noticed By the Owner.
For Alcove or Closet Installation see section 9. For Bathroom or Bedroom Installation see section 10. For Mobile or Manufactured Homes see section 11.
Installation Instructions
Minimum Clearance Other Than Alcove or Closet Installation
Minimum clearance to combustible surfaces and for air opening are: 0 in.
clearance both sides and 1 in. rear.Consideration must be given to provide
adequate clearance for installation and service.
PREPARING FOR INSTALLATION OF NEW DRYER
TIP : Install your dryer before installing your washer. This will allow better access when installing dryer exhaust.
DISCONNECTING GAS
DISCONNECT AND DISCARD OLD FLEXIBLE GAS CONNECTOR AND OLD TRANSITION DUCTING MATERIAL. REPLACE WITH NEW CSA(AGA) APPROVED FLEXIBLE GAS LINE CONNECTOR AND UL APPROVED TRANSITION DUCT.
WARNING – NEVER REUSE OLD FLEXIBLE CONNECTORS.
The use of old flexible connectors can cause leaks and personal injury. Always use new flexible connectors when installing gas appliances
REMOVING LINT FROM WALL EXHAUST OPENING
Remove and discard existing plastic or metal foil transition duct and
replace with UL listed transition duct.
GAS REQUIREMENTS
WARNING
- Installation must conform to local codes and ordinances, or in their absence, the NATIONAL FUEL GAS CODE, ANSI Z223.
- This gas dryer is equipped with a Valve & Burner Assembly for use only with natural gas. Using conversion kit WE25X0217, your local service organization can convert this dryer for use with propane (LP) gas. ALL CONVERSIONS MUST BE MADE BY PROPERLY TRAINED AND QUALIFIED PERSONNEL AND IN ACCORDANCE WITH LOCAL CODES AND ORDINANCE REQUIREMENTS.
- The dryer must be disconnected from the gas supply piping system during any pressure testing of that system at a test pressure in excess of 0.5 PSI (3.4 KPa).
- The dryer must be isolated from the gas supply piping system by closing the equipment shut-off valve during any pressure testing of the gas supply piping of test pressure equal to or less than 0.5 PSI (3.4 KPa).
GAS SUPPLY
- A 1/8-in.National Pipe Taper thread plugged tapping, accessible for test gauge connection, must be installed immediately upstream of the gas supply connection to the dryer. Contact your local gas utility should you have questions on the installation of the plugged tapping.
- Supply line is to be 1/2-in. rigid pipe and equipped with an accessible shut-off within 6 ft. of, and in the same room with the dryer.
- Use pipe thread sealer compound or Teflon tape appropriate for natural or LP gas.
- You must use with this dryer a flexible metal connectorlisted connector ANSI Z21.24 / CSA 6.10. The length of the connect shall not exceed 3 ft. • Connect flexible metal connector to dryer and gas supply.
- Open shut-off valve.
RECONNECTING GAS
Listed connector ANSI Z21.24 / CSA 6.10
Note : The connector and fittings are designed for use only on the original installation and are not to be reused for another appliance or at another location. Keep flare end of adaptor free of grease, oil and thread sealant. Caution: Use adapters as shown. Connector nuts must not be connected directly to pipe threads.
LEAK TEST
WARNING : NEVER USE AN OPEN FLAME TO TEST FOR GAS LEAKS
Check all connections for leaks with soapy solution or equivalent. Apply soap solution. Leak test solution must not contain ammonia which could cause damage to the brass fittings. If leaks are found, close valve, retighten the joint, and repeat the soap test.
ELECTRICAL CONNECTION INFORMATION
WARNING – TO REDUCE THE RISK OF FIRE, ELECTRICAL SHOCK, AND PERSONAL
INJURY:
DO NOT USE AN EXTENSION CORD OR AN ADAPTER PLUG WITH THIS APPLIANCE. Dryer
must be electrically grounded in accordance with local codes and ordinances,
or in the absence of local codes, in accordance with the NATIONAL ELECTRICAL
CODE, ANSI/NFPA NO. 70.
ELECTRICAL REQUIREMENTS
This appliance must be supplied with 120V, 60Hz, and connected to a properly
grounded branch circuit,protected by a 15- or 20- amp circuit breaker or
timedelayfuse. If electrical supply provided does not meet the above
specifications, it is recommended that a licensed electrician install an
approved outlet.
WARNING – THIS DRYER IS EQUIPPED A THREE-PRONG (GROUNDING) PLUG FOR YOUR PROTECTION AGAINST SHOCK HAZARD AND SHOULD BE PLUGGED DIRECTLY INTO A PROPERLY GROUNDED THREE-PRONG RECEPTACLE. DO NOT CUT OR REMOVE THE GROUNDING PRONG FROM THIS PLUG.
EXHAUST INFORMATION
WARNING – IN CANADA AND IN THE UNITED STATES, THE REQUIRED EXHAUST DUCT DIAMETER IS 4 IN (102mm). DO NOT USE DUCT LONGER THAN SPECIFIED IN THE EXHAUST LENGTH TABLE.
Using exhaust longer than specified length will:
- Increase the drying times and the energy cost.
- Reduce the dryer life.
- Accumulate lint, creating a potential fire hazard.
- The correct exhaust installation is YOUR RESPONSIBILITY. Problems due to incorrect installation are not covered by the warranty.
- Remove and discard existing plastic or metal foil transition duct and replace with UL listed transition duct.
- The MAXIMUM ALLOWABLE duct length and number of bends of the exhaust system depends upon the type of duct, number of turns, the type of exhaust hood (wall cap), and all conditions noted below. The maximum duct length for rigid metal duct is shown in the table below.
EXHAUST LENGTH
EXHAUST SYSTEM CHECK LIST
HOOD OR WALL CAP
- Terminate in a manner to prevent back drafts or entry of birds or other wildlife.
- Termination should present minimal resistance to the exhaust airflow and should require little or no maintenance to prevent clogging.
- Never install a screen in or over the exhaust duct. This could cause lint build-up.
- Wall caps must be installed at least 12 in. above ground level or any other obstruction with the opening pointed down.
SEPARATION OF TURNS
For best performance, separate all turns by at least 4 ft. of straight duct,
including distance between last turn and the exhaust hood.
TURNS OTHER THAN 90º
- One turn of 45º or less may be ignored.
- Two 45º turns should be treated as one 90º turn.
- Each turn over 45º should be treated as one 90º turn.
SEALING OF JOINTS
- All joints should be tight to avoid leaks. The male end of each section of duct must point away from the dryer.
- Do not assemble the ductwork with fasteners that extend into the duct. They will serve as a collection point for lint.
- Duct joints can be made air and moisture-tight by wrapping the overlapped joints with duct tape.
- Horizontal runs should slope down toward the outdoors ½inch per foot
INSULATION
The ductwork that runs through an unheated area or is near air conditioning
should be insulated to reduce condensation and light build-up.
EXHAUST CONNECTION
WARNING – TO REDUCE THE RISK OF FIRE OR PERSONAL INJURY:
-
This clothes dryer must be exhausted to the outdoors.
Use only 4” rigid metal ducting for the home exhaust duct. -
Use only 4” rigid metal or UL-listed flexible metal (semi-rigid or foil-type) duct to connect the dryer to the home exhaust duct. It must be installed in accordance with the instructions found in “Connecting The Dryer To House Vent” on page 6 of this manual.
-
Do not terminate exhaust in a chimney, a wall, a ceiling, gas vent, crawl space, attic, under an enclosed floor, or in any other concealed space of a building. The accumulated lint could create a fire hazard.
-
Never terminate the exhaust into a common duct with a kitchen exhaust system. A combination of grease and lint creates a potential fire hazard.
-
Do not use duct longer than specified in the exhaust length table. Longer ducts can accumulate lint, creating a potential fire hazard.
-
Never install a screen in or over the exhaust duct. This will cause lint to accumulate, creating a potential fire hazard.
-
Do not assemble ductwork with any fasteners that extend into the duct. These fasteners can accumulate lint, creating a potential fire hazard.
-
Do not obstruct incoming or exhausted air.
-
Provide an access for inspection and cleaning of the exhaust system, especially at turns and joints. Exhaust system shall be inspected and cleaned at least once year.
THIS DRYER COMES READY FOR REAR EXHAUSTING. IF SPACE IS LIMITED, USE THE INSTRUCTIONS IN SECTION 9 TO EXHAUST DIRECTLY FROM THE SIDES OR BOTTOM OF THE CABINET.
STANDARD REAR EXHAUST (Vented at floor level)
FOR STRAIGHT LINE INSTALLATION, CONNECT THE DRYER EXHAUST TO THE EXTERNAL
EXHAUST HOOD USING DUCT TAPE OR CLAMP.
STANDARD REAR EXHAUST (Vented above floor level)
NOTE : ELBOWS WILL PREVENT DUCT KINKING AND COLLAPSING.
LEVELING DRYER
CONNECTING THE DRYER TO HOUSE VENT
RIGID METAL TRANSITION DUCT
- For best drying performance, a rigid metal transition duct is recommended.
- Rigid metal transitions ducts reduce the risk of crushing and kinking. UL-LISTED FLEXIBLE METAL (SEMI-RIGID TRANSITION DUCT
- If rigid metal duct cannot be used, then UL-listed flexible metal (semi-rigid) ducting can be used (Kit WX08X10077).
- Never install flexible metal duct in walls, ceilings, floors or other enclosed spaces.
- Total length of flexible metal duct should not exceed 8 feet (2.4m).
- For many applications, installing elbows at both the dryer and the wall is highly recommended (see illustrations below). Elbows allow the dryer to sit close to the wall without kinking and or crushing the transition duct, maximizing drying performance.
- Avoid resting the duct on sharp objects. UL-LISTED FLEXIBLE METAL (FOIL-TYPE) TRANSITION DUCT
- In special installations, it may be necessary to connect the dryer to the house vent using a flexible metal (foil type) duct. A UL-listed flexible metal (foil-type)duct may be used ONLY in installations where rigid metal or flexible metal (semi-rigid) ducting cannot be used AND where a 4” diameter can be maintained throughout the entire length of the transition duct.
- In Canada and the United States, only the flexible metal(foiltype) ducts that comply with the “Outline for Clothes Dryer Transition Duct Subject 2158A” shall be used.
- Never install flexible metal duct in walls, ceilings, floors or other enclosed spaces.
- Total length of flexible metal duct should not exceed 8 feet (2.4m).
- Avoid resting the duct on sharp objects.
- For best drying performance:
- Slide one end of the duct over the clothes dryer outlet pipe.
- Secure the duct with a clamp.
- With the dryer in its permanent position, extend the duct to its full length. Allow 2” of duct to overlap the exhaust pipe. Cut off and remove excess duct. Keep the duct as straight as possible for maximum airflow.
- Secure the duct to the exhaust pipe with the other clamp.
ALCOVE OR CLOSET INSTALLATION
- If your dryer is approved for installation in an alcove or closet, it will be stated on a label on the dryer back.
- The dryer MUST be vented to the outdoors. See the EXHAUST INFORMATION section.
- Minimum clearance between dryer cabinet and adjacent walls or other surfaces is: 0 in. either side 3 in. front and rear
- Minimum vertical space from floor to overhead cabinets, ceiling, etc. is 52 in.
- Closet doors must be louvered or otherwise ventilated and must contain a minimum of 60 sq. in. of open area equally distributed. If the closet contains both a washer and a dryer, doors must contain a minimum of 120 sq.in. of open area equally distributed.
- The closet should be vented to the outdoors to prevent gas pocketing in case of a gas leak in the supply line.
- No other fuel-burning appliance shall be installed in the same closet with the dryer.
BATHROOM OR BEDROOM INSTALLATION
- The dryer MUST be vented to the outdoors. See EXHAUST INFORMATION section 6.
- The installation must conform with local codes or, in the absence of local codes, with the NATIONAL FUEL GAS CODE, ANSI Z223.
MOBILE OR MANUFACTURED HOME INSTALLATION
- Installation must conform to the MANUFACTURED HOME CONSTRUCTION & SAFETY STANDARD, TITLE 24, PART 32-80 or, when such standard is not applicable, with AMERICAN NATIONAL STANDARD FOR MOBILE HOME, NO. 501B.
- The dryer MUST be vented to the outdoors with the termination securely fastened to the mobile home structure. (See EXHAUST INFORMATION section 6.)
- The vent MUST NOT be terminated beneath a mobile or manufactured home.
- The vent duct material MUST BE METAL.
- KIT 14-D346-33 MUST be used to attach the dryer securely to the structure.
- The vent MUST NOT be connected to any other duct, vent, or chimney.
- Do not use sheet metal screws or other refastening devices which extend into the interior of the exhaust vent.
- Provide an opening with a free area of at least 25 sq. in.or introduction of outside air into the dryer room.
DRYER EXHAUST TO RIGHT, LEFT OR BOTTOM CABINET
WARNING – BEFORE PERFORMING THIS EXHAUST INSTALLATION, BE SURE TO
DISCONNECT THE DRYER FROM ITS ELECTRICAL SUPPLY. PROTECT YOUR HANDS AND ARMS
FROM SHARP EDGES WHEN WORKING INSIDE THE CABINET. BE SURE TO WEAR GLOVES
Detach and remove the bottom, right or left side knockout as desired. Remove the screw inside the dryer exhaust duct and save. Pull the duct out of the dryer
Note : Only 4” round rigid metal ducting allowed inside dryer.
TAB LOCATION
Through the rear opening, locate the tab in the middle of the appliance base. Lift the tab to about 45º using a flat blade screwdriver.
ADDING NEW DUCT
Reconnect the cut portion (A) of the duct to the blower housing. Make sure that the shortened duct is aligned withthe tab in the base. Use the screw saved previously to secure the duct in place through the tab on the appliance base.
ADDING ELBOW AND DUCT FOR EXHAUST TO LEFT SIDE OF CABINET
- Preassemble 4” elbow with 4” duct. Wrap duct tape around joint.
- Insert duct assembly, elbow first, through the side opening and connect the elbow to the dryer internal duct.
CAUTION : Be sure not to pull or damage the electrical wires inside the dryer when inserting the duct.
Apply duct tape as shown on the joint between the dryer internal duct and the elbow.
CAUTION :
Internal duct joints must be secured with tape, otherwise they may separate
and cause a safety hazard.
ADDING ELBOW FOR EXHAUST THROUGH BOTTOM OF CABINET
- Insert the elbow through the rear opening and connect it to the dryer internal duct.
- Apply duct tape on the joint between the dryer internal duct and elbow, as shown on page 7.
CAUTION :
Internal duct joints must be secured with tape, otherwise they may separate
and cause a safety hazard.
ADDING COVER PLATE TO REAR OF CABINET
Connect standard metal elbows and ducts to complete the exhaust system. Cover back opening with a plate (Kit WE1M454) available from your local service provider. Place dryer in final location.
WARNING -NEVER LEAVE THE BACK OPENING WITHOUT THE PLATE.
CHANGING DIRECTION OF DOOR OPENING
CONNECTING INLET HOSES
(on some models)
To produce steam, the dryer must connect to the cold water supply. Since the
washer must also connect to the cold water, a “Y” connector is inserted to
allow both inlet hoses to make that connection at the same time.
NOTE : Use the new inlet hoses provided; never use old hoses.
-
Turn the cold water faucet off. Remove the washer inlet hose from the washer fill valve connector (cold).
-
Ensure the rubber flat washer is in place and screw the female coupling of the short hose onto the washer fill valve connector. Tighten by hand until firmly seated.
-
Attach the female end of the ‘’Y’’ connector to the male coupling of the short hose. Ensure the rubber flat washer is in place. Tighten by hand until firmly seated.
-
Insert the filter screen in the coupling of the washer’s inlet hose. If a rubber flat washer is already in place remove it before installing the filter screen. Attach this coupling to one male end of the ‘’Y’’ connector. Tighten by hand until firmly seated.
-
Ensure the rubber flat washer is in place and attach the dryer’s long inlet hose to the other male end of the ‘’Y’’ connector. Tighten by hand until firmly seated.
-
Ensure the rubber flat washer is in place and attach the other end of the dryer’s long inlet hose to the fill valve connector at the bottom of the dryer back panel. Tighten by hand until firmly seated.
-
Using pliers, tighten all the couplings with an additional two–thirds turn.
NOTE: Do not overtighten. Damage to the couplings may result. -
Turn the water faucet on.
-
Check for leaks around the ‘’Y’’ connector, faucet and hose couplings.
WATER SUPPLY REQUIREMENTS
Hot and cold water faucets MUST be installed within 42 in. (107 cm) of your
washer’s water inlet. The faucets MUST be 3/4 in. (1.9 cm) garden hose-type so
inlet hosescan be connected. Water pressure MUST be between 10 and 120 pounds
per square inch. Your water department can advise you of your water pressure.
NOTE : A water softener is recommended to reduce buildup of scale inside the steam generator if the home water supply is very hard.
SERVICING
WARNING – LABEL ALL WIRES PRIOR TO DISCONNECTION WHEN SERVICING CONTROLS.
WIRING ERRORS CAN CAUSE IMPROPER AND DANGEROUS OPERATION AFTER SERVICING/
INSTALLATION.
For replacement parts and other information, refer to Owner’s Manual for servicing phone numbers.
TO REGISTER YOUR DRYER CALL TOLL-FREE
Prompt registration confirms your right to protection under the terms of your warranty.
For Questions on Installation, Call: 1-800-626-2000 (US) or 1-800-561-3344 (Canada).
FAQs
Q: Can I reuse old flexible gas connectors?
A: No, it is not recommended to reuse old flexible connectors as they can
cause leaks and pose a risk of personal injury. Always use new flexible
connectors when installing gas appliances.
Q: What should I do before beginning the installation process?
A: Before starting, make sure to read the instructions thoroughly, gather
all the required tools and materials, and follow each step carefully to ensure
a safe and proper installation.