KOHLER K-P8304-IPX Valve Body and Cartridge Kit Complete Owner’s Manual

July 6, 2024
Kohler

KOHLER K-P8304-IPX Valve Body and Cartridge Kit Complete

Features

  • Project pack: Supplied 12 per case
  • Includes valve body, pressure balance cartridge, rough-in guide, and mudguard
  • 1/2″ female NPT inlets and outlets
  • 5 gpm (18.9 l/min) maximum flow rate at 45 psi
  • Single lever design cycles from off through cold to hot
  • Antiscald protection
  • One-piece cartridge design simplifies installation and maintenance
  • Adjustable high-temperature limit stop to control maximum water temperature
  • Requires valve trim to complete installation (sold separately)
  • Pressure-balancing diaphragm technology maintains outlet temperature within +/-3°F during water pressure fluctuations

Material
Forged dezincification-resistant brass body provides long term reliability and resistance to aggressive water conditions

Installation

  • Designed for use in standard, back-to-back and thin wall installations
  • Valve body features integral mounting locations and symmetrical valve inlets to simplify installation
  • Cartridge is reversible for installations where hot and cold supplies are reversed
  • Rough-in guide designed for both standard and thin wall installations
  • Installed valve rough-in can be flushed and pressure-tested to 150 psi max (air or water) without cartridge by using test cap (sold separately)

Optional Products/Accessories

  • K-10350 Deep rough-in kit
  • K-10351 Test cap for K-8300 Series valve bodies

Codes/Standards
ASME A112.18.1/CSA B125.1
ASSE 1016/ASME A112.1016/CSA B125.16 IAPMO Certification

KOHLER® Faucet Lifetime Limited Warranty
See website for detailed warranty information.

Technical Information

All product dimensions are nominal.

Shower Valve:
Pressure: 45 psi (3.1 bar)
Maximum (Static) Pressure: 125 psi (8.6 bar)
Minimum (Operating) Pressure: 20 psi (1.4 bar)

Notes

  • Install this product according to the installation guide.
  • Avoid cross-flow conditions. Do not install a shut-off device on either valve outlet.
  • Cap the shower outlet if the deck-mounted spout, diverter, or hand shower is connected to the spout outlet.
  • Install straight pipe or tube drop of 7″ (178 mm) to 18″ (457 mm) with single elbow between the valve and the wall-mount spout.
  • For finished walls greater than 3/4″ (19 mm) and less than 1-1/2″ (38 mm), install support(s) 2″ (51 mm) from the stud face.
  • For finished walls greater than 1-1/2″ (38 mm), install support(s) 3″ (76 mm) from the face of the finished wall.

1-800-4KOHLER (1-800-456-4537)
Kohler Co. reserves the right to make revisions without notice to product specifications.
For the most current Specification Sheet, go to www.kohler.com USA or www.kohler.ca Canada 6-15-2024 20:55 – US