Sea Breeze 12H43ZGX-18H43ZGX Mini Split Heat Pump Installation Guide

July 6, 2024
Sea Breeze

Sea Breeze 12H43ZGX-18H43ZGX Mini Split Heat Pump

Sea-Breeze-12H43ZGX-18H43ZGX-Mini-Split-Heat-Pump-product-
image

Specifications

  • Model: SEA BREEZE 18H43ZGX
  • System Type: Mini-Split Heat Pump
  • Capacity:
    • 12,000 BTU for 12H43ZGX
    • 18,000 BTU for 18H43ZGX
  • Power Supply: 208-230 VAC
  • SEER: 13

Product Usage Instructions

Select Installation Location
Ensure the installation location is suitable

  • Avoid locations exposed to machine oil, flammable or corrosive gases, and high-frequency waves.
  • Indoor and outdoor unit locations should be chosen carefully.

Electrical Safety Requirements
Follow grounding requirements and ensure proper electrical installation by a qualified technician.

Indoor Unit Installation

Mounting Rear Panel

  1. Mount the rear panel horizontally on the wall and ensure it is level.
  2. Mark screw locations, then fasten the rear panel securely using supplied screws.

Creating Piping Hole

  1. Select left or right-positioned hole based on the installation dimension diagram.
  2. Create a 2.5-inch diameter hole at a slight downward slant for proper drainage.
  3. Insert a piping-hole sleeve to protect piping and wiring.

Installing Drainage Hose Extension (Optional)
If needed, use the included extension for the drainage hose. Do not bend or wrench the hose during installation.

FAQ

  • Q: Can I install the indoor unit in damp locations?

    • A: No, do not install the indoor unit in damp or wet locations to prevent damage and ensure safety.
  • Q: What should I do if the drainage hose is not long enough?

    • A: You can use the included drainage hose extension if the attached drainage line is not long enough for your application.

This Owner’s Manual is provided and hosted by Appliance Factory Parts.

Appliance Factory Parts Experts in BBQ. Humidifier, & Appliance Parts
1-800-955-7075

SEA BREEZE 18H43ZGX Owner’s Manual
Shop genuine replacement parts for SEA BREEZE 18H43ZGX

Find Your SEA BREEZE Air Conditioner Parts – Select From 23 Models

Manual continues below

INSTALLATION INSTRUCTIONS

MINI-SPLIT
HEAT PUMP

FOR MODELS
12H43ZGX
18H43ZGX

TECHNICAL SUPPORT
IF YOU NEED TECHNICAL SUPPORT PLEASE CALL 1-(704)504-8590
SEA BREEZE Installation Kit is recommended. Catalog number can be located on page 17.

MODEL NUMBERS

Heat Pump

SYSTEM MODEL

12H43ZGX

| Indoor Unit       12H43ZIGX
---|---
Outdoor Unit    12H43ZOGX

12,000 BTU 208-230 VAC
13 SEER

SYSTEM MODEL

18H43ZGX

| Indoor Unit       18H43ZIGX
---|---
Outdoor Unit    18H43ZOGX

18,000 BTU 208-230 VAC
13 SEER

UNIT PARTS & FEATURES

Sea-Breeze-12H43ZGX-18H43ZGX-Mini-Split-Heat-Pump-image
\(3\)

INSTALLATION DIMENSION DIAGRAM

Sea-Breeze-12H43ZGX-18H43ZGX-Mini-Split-Heat-Pump-image
\(4\)

SAFETY WARNINGS

  • Use Copper Wires only for Power Supply.
  • Risk of electric shock can cause injury or death. Disconnect all electric power supplies before servicing or installation
  • Do not use excessive torque on flare nuts during connection of the refrigeration tubes, or service valve on discharge line may be damaged.
  • Do not install indoor unit in damp or wet locations.
  • Electrical installation must be done by a qualified technician according to the instruction manual and in accordance with local electrical standards.
  • Certified Power supply conductors must be used.

SELECT INSTALLATION LOCATION

CAUTION: The air conditioning unit must be installed by professional technicians.

BASIC REQUIREMENTS FOR INSTALLATION POSITION

  • Installation of Either unit in the following locations may cause malfunction. Locations exposed to:
  • Machine oil
  • Flammable or corrosive gasses
  • High frequency waves (i.e. from radio equipment, medical equipment, etc.)

INDOOR UNIT LOCATION

  • Intake and outlet should not be obstructed.
  • The wall the unit is to be mounted on should allow for a clear hole for the condensation drain and the refrigeration lines.
  • The wall the unit is mounted on should be strong enough to bear the weight and vibration of the unit.
  • Allow for proper clearances around the unit – see installation dimension diagram.
  • Location should allow easy access for maintenance and removal of air filter.
  • Position unit and remote control at least 3 feet from electric appliances such as televisions, radios, etc.
  • Keep unit and remote out of direct sunlight and/or florescent lighting and away from any excessive heat source, steam, or flammable materials.

OUTDOOR UNIT LOCATION

  • Allow sufficient ventilation around the unit – see installation dimension diagram.
  • The air intake and outlet should not be obstructed.
  • Position unit so that noise and outlet airflow will not inconvenience neighbors.
  • Position unit on a solid foundation. Location should be able to withstand the full weight and vibration of the unit.
  • Installation should not be performed in the following locations exposed to: machine oil, flammable or corrosive gases, high – frequency waves (i.e. from radio equipment, medical equipment, etc.)
  • Installation location should beyond the reach of children.

ELECTRICAL SAFETY REQUIREMENTS

  • The power supply must be of rated voltage via special circuit for air-conditioner. The power supply wire gauge is specified in page 9.
  • Applicable voltage range: the normal operation range of voltage is 90%~110% of rated voltage.
  • Do not pull the power cable with excessive force.
  • System grounding to be completed by a licensed technician, using National Electrical Code procedures and UL materials. In the fixed line there must be an electrical leakage protection switch and an air
  • switch with sufficient capacity. The air switch shall also have the magnetic tripping and thermal tripping functions to achieve protection of both short-circuit and overload.
  • The minimum clearance between air conditioner and flammable surface is 5 ft.

GROUNDING REQUIREMENT

  • As air-conditioning unit is of Class I electrical appliance, reliable grounding measures must be taken
    for it.

  • The green cable inside the air conditioner is for grounding and shall not be used for other purposes nor can it be cut. Do not tighten with tapping screw; otherwise electric shock will be caused.

  • The ground resistance shall be in conformity with the requirements of state standard.

  • The user power supply shall have reliable grounding terminal. It is prohibited to connect the grounding wire to the following items:

  • Water Supply Pipe

  • Gas Pipe

  • Sewage Pipe

  • Other positions that are considered to be unreliable by professionals .

INDOOR UNIT INSTALLATION

INSTALL THE REAR PANEL-MOUNTING PLATE

  • Always mount rear panel horizontally.
  • Hold the rear panel on the wall where you want the unit to be located and ensure that it is level using a plumb line or level. Once leveled, mark the screw locations on the wall.
  • Fasten the rear panel to the wall at the location marked using the screws supplied with the unit. Insure that the panel has been mounted firmly to withstand the weight of the unit for about 132 lbs, with the weight being evenly distributed by each screw.

INSTALL THE PIPING HOLE

  • Select the location for the piping hole – either left-positioned or right-positioned (see installation dimension diagram).
  • Make piping hole in the wall approximately 2.5 inches in diameter at a slight downward slant (this ensures proper drainage).
  • Insert a piping-hole sleeve in the hole (i.e. PVC pipe) to prevent the connection piping and wiring from being damaged

INSTALL DRAINAGE HOSE EXTENSION (OPTIONAL)

  • Drainage hose extension is included with unit, for use if attached drainage line is not long enough for your application. ridge twist
  • Please note that the extension can be installed after existing drainage pipe is fed through wall later in the installation process, if it is determined later that it is necessary.
  • Do not wrench or bend drainage hose or extension.

WIRE THE INDOOR UNIT
CAUTION: All electrical wiring must be done by a qualified technician in accordance with local electrical codes.

  • A separate circuit breaker must be provided.
  • AC power for the indoor unit is provided by the power cable that runs between the outdoor unit and the indoor unit.
  • If a disconnect switch is required for the indoor unit, it must be properly rated. Disconnect switch may be installed by breaking the individual wires connected to pins (N1) and (3) of the control cable. See table 1 for recommended value.

MODEL| INTERCONNECTING WIRE GAUGE| POWER SUPPLY WIRE

GAUGE

| CIRCUIT BREAKER
---|---|---|---
12H43ZGX| 16 AWG| 14 AWG| 15 AMP
18H43ZGX| 16 AWG| 14 AWG| 20 AMP

-Table 1-

MODEL
12H43ZGX
18H43ZGX

NOTE
Power connection cable is provided in the installation kit (sold separately). If the cable is not of sufficient length, it will be necessary to purchase cable for this purpose.
Do not splice cable.

INDOOR UNIT INSTALLATION

PREPARE REFRIGERATION LINES
Refrigeration lines and wiring can be routed from the indoor unit several different ways using the cut-out access pieces on the back of the unit.
Bend the refrigeration lines carefully to the position needed to align with the drilled piping hole.

Sea-Breeze-12H43ZGX-18H43ZGX-Mini-Split-Heat-Pump-image
\(9\)

HANG INDOOR UNIT
Bundle the refrigeration lines, drainage hose, and wiring conduit attached to the indoor unit and wrap them securely for enough length to extend through the piping hole to the exterior of the building.
Note: leave remainder unwrapped to allow for remaining step in installation of the outdoor unit and connecting the indoor unit to the outdoor unit. Carefully push bundled lines through the piping hole.
Hang the unit on the wall by hooking the mounting slots of the unit over the upper tabs of the rear panel.
Check to make sure the: unit is properly secured – it should feel firmly attached to the wall, and you should not be able to slide it to the right or left.

OUTDOOR UNIT INSTALLATION

CONNECT REFRIGERATION LINES
Align the center of the piping flare with the relevant valve.
Use standard A/C practices to attach the connection pipes to the proper pipes of the bundled lines coming through the wall from the indoor unit.
Tighten the flare nut of the connection pipes using a spanner and torque wrench. (see diagram)

Note
Do not over-tighten flare nuts, or the connection may be damaged. Unit is charged with enough R410A Refrigerants for a standard designed length. For longer line set lengths additional charge must be

WEIGHED in per Table 2.

Model Designed Length ft Refrigerants Charge oz/ft
12H43ZGX 19 .21
18H43ZGX 26 .26

-Table 2-

INSULATE/BUNDLE REFRIGERATION LINES AND WIRING
Individually insulate all refrigeration lines and condensation drainage hose to ensure that they do not sweat. This will help to maintain the unit at its proper capacities.
Once all lines have been properly insulated, bundle the refrigeration lines with the wiring conduit and wrap securely to complete the run to the outdoor unit.

Note
The condensation drainage hose should be left free of the bundled lines in order to drain properly.

INSTALL OUTDOOR CONDENSATION DRAINAGE HOSE
When the heat pump unit is heating or defrosting, wastewater forms in the outdoor unit. This can be drained off using the outdoor drain elbow and hose provided.
Insert the drain elbow into the hole on the base plate as shown.
Join the drain hose to the elbow and turn so that the water drains to the desired location.

WIRE THE OUTDOOR UNIT

CAUTION
Wrong wiring connection will cause electrical malfunction. Do not pull the wire when it is fixed with wire clamp. Sea-Breeze-12H43ZGX-18H43ZGX-Mini-
Split-Heat-Pump-image \(13\)

CAUTION: DO NOT CROSS WIRE

TESTING

NOTE
Installation MUST be complete prior to testing.
System MUST be tested prior to operation.

LEAKAGE TEST
Use standard A/C practices to properly check refrigeration tubes and connections for any leaks prior to system start up.

AIR PURGING AND PRESSURE TEST

  • Remove bonnet (cover) of gas valve on outdoor unit.
  • Charge system with Nitrogen to 100 PSI and check for leaks. Evacuate Nitrogen.
  • Connect the gas valves of a vacuum gauge, vacuum pump, and outdoor unit(see diagram). Start the vacuum pump and allow to run for at least 30 minutes at a level of 500 microns or less.
  • Shut off the vacuum and continue to monitor vacuum gauge for another 15 minutes. The pressure should not rise above 800 microns. lf a vacuum of 500 microns cannot be obtained, or if it rises above
  • 800 microns during the l5-minute monitoring period, pressurize the system with nitrogen and look for leaks. Repair any leaks that are found and repeat the vacuum testing.
  • Close the valves to the vacuum pump and gauge and disconnect from the outdoor unit.
  • Tighten bonnet (cover) of gas valve and open gas and liquid valves completely.

SYSTEM TESTING

  • Before testing the system, ensure that cut-off valves of the connection pipes are opened and that all debris (such as packing scraps, debris, etc.) are clear from the unit.
  • Switch on power to the system and press the ”ON/OFF” button on the remote control to activate the indoor unit.
  • Press ”MODE” button repeatedly, taking a moment on each setting to ensure that system functions in all modes.
  • If the remote control is lost, emergency run operation can be initiated by pressing the button in the upper right corner of the indoor unit under the cover panel. (see diagram) 

INSTALLATION VERIFICATION

  • Have both units been securely and firmly installed?
  • Are all piping connections secure?
  • Have the refrigeration lines been sufficiently insulated?
  • Have you verified the length of the connection pipes and the refrigerant capacity? Have you conducted all leakage and system tests?
  • Does the unit drain properly?
  • Are all electrical connections in compliance with local standards?
  • Has the unit been properly grounded?
  • Is the power cord as specified?
  • Are all air inlets and outlets free from obstruction?

PRINCIPLE

COOLING MODE

Principle
The air conditioner absorbs heat from indoor air and transmits it outdoors for discharge, hence to decrease the indoor ambient temperature. The cooling capacity decreases with the rise of outdoor ambient temperature.

Anti-freeze Function
If the air conditioner is running under low-temperature cooling mode, frost will appear on the surface of indoor heat exchanger. When the temperature of indoor heat exchanger is decreased to 32℉ or below, the microcomputer of indoor unit will stop the compressor to protect the complete unit.

HEATING MODE

Principle
The air conditioner absorbs heat from outdoor air and transmits it indoors for emission, hence to increase the air temperature in the room. The heating capacity decreases with the reduction of the outdoor ambient temperature.

It takes only a short time for this type of hot air circulating system to increase the indoor temperature.
Use this air conditioner with other heating equipment if the outdoor temperature is extremely low.

Defrost
When the outdoor temperature is low but the humidity is high, the heat exchanger of outdoor unit may frost after the air conditioner has run for a period of time. This will decrease the heating effect.
In this case, auto defrost function will be activated and the heating mode will temporarily stop for 8-10 minutes.
Both the indoor fan and outdoor fan will be stopped during auto defrost.
During defrost, the indicator on indoor unit will blink and steam might flow from the indoor unit. This is caused by the defrost mode.
Heating mode will automatically resume upon completion of defrost process.

Anti-Draft Protection
If the following conditions are present, the control circuitry in the unit will prevent the indoor fan from operating:

  1. Heat mode (delay 3 minutes).
  2. Auto defrost (delay 3 minutes after defrost cycle has completed).
  3. If the outdoor ambient temperature falls below 20 ℉, indoor fan will not operate.

Air Conditioner is Unable to Run Normally
Protection device might be activated within such temperature range as Table 3, so that the unit might be stopped.

| Heating Mode| Cooling Mode| Dehumidify Mode
---|---|---|---
Outdoor Temperature| ≥75°F or ≤20°F| ≥109°F| N/A
Room Temperature| ≥80°F| ≤70°F| ≤64°F

– Table 3 –

NOTE: If the unit operates in cooling or humidify mode for a long period that the relative humidity is higher than 80% (while door and windows open), dew might drop near the air outlet.

MINI-SPLIT SPECIFICATIONS

Model| 12H43ZGX| 18H43ZGX
Function| COOLING/HEATING| COOLING/HEATING
Rated Voltage| 208~230 VAC| 208~230 VAC
Rated Frequency| 60Hz| 60Hz
Cooling/Heating Capacity (BTU/h)| 12000/13000| 18000/20000
SEER| 13| 13
Cooling/Heating Power Input (W)| 1150/1250| 1720/1750
Cooling/Heating Rated Input (W)| 1100/1200| 1350/1800
Cooling/Heating Rated Current (A)| 5.5/6.5| 8.56-7.74/8.65-7.83
Minimum Circuit Ampacity (A)| 7| 10
Breaker Size (A)| 15| 15
Air Flow Volume (CFM)| 325| 470
Dehumidifying Volume (pt/h)| 2.7| 4.4
Indoor unit| Model of Indoor Unit| 12H43ZIGX| 18H43ZIGX
Fan Motor Speed (r/m) (L/M/H)| 1050/1100/1250| 1250/1300/1350
Output of Fan Motor (w)| 20| 21
Input of Heater (w)| None| None
Fan Motor Capacitor (uF)| 1| 1
Fan Motor RLA(A)| 0.152| 0.28
Fan Type-Piece| Cross flow fan-1| Cross flow fan-1
Diameter-Length (in)| 3.6-24.3| 3.8-31.4
Evaporator| Aluminum fin-copper tube| Aluminum fin-copper tube
Pipe Diameter (in)| 0.275| 0.275
Row-Fin Gap(in)| 2-0.055| 2-0.063
Coil length (L) x height (H) x coil width (L) (in)| 26.8×12.8×1.5| 30.1×13.4×1
Swing Motor Model| MP28EA| MP24GA
Output of Swing Motor (W)| 2| 2
Fuse (A)| PCB3.15A Transformer

0.2A

| PCB3.15A Transformer

0.2A

Sound Pressure Level dB (A)(L/M/H)| 38/39/43| 40/43/46
Sound Power Level dB (A)| 48/49/53| 50/53/56
Dimension (W/D/H)(approx in)| 33×9×11| 40×9×12
Dimension of Package (W/D/H)(approx in)| 34×12×15| 42×13×15
Net Weight /Gross Weight (lb)| 24/33| 31/41
Outdoor unit| Model of Outdoor Unit| 12H43ZOGX| 18H43ZOGX
Compressor Model| Sanyo C-6RZ092H1AB| Hitachi EU1013DD
Compressor Type| Rotary| Scroll
L.R.A. (A)| 33| 27
Compressor RLA(A)| 5| 6.54
Compressor Power Input(W)| 628| 1266
Overload Protector| Yes| Yes
Throttling Method| Capillary throttling| Capillary throttling
Starting Method| Transducer starting| Transducer starting
Outdoor Operating Range| 23°F to 109°F| 23°F to 109°F
Condenser| Aluminum fin-copper tube| Aluminum fin-copper tube
Pipe Diameter (in)| 3/8| 3/8
Rows-Fin Gap(in)| 2-0.055| 2-0.059
Coil length (L) x height (H) x coil width (L) (in)| 25.4×20×1.7| 28.8×26×1.7
Fan Motor Speed (rpm)| 830| 780/620
Output of Fan Motor (W)| 30| 60
Fan Motor RLA(A)| 0.3| 0.65
Fan Motor Capacitor (uF)| 2.5| 3
Air Flow Volume of Outdoor Unit (CFM)| 1200| 1600
Fan Type-Piece| Axial fan –1| Axial fan –1
Fan Diameter (in)| 15.75| 15.75
Defrosting Method| Auto defrost| Auto defrost
Climate Type| T1| T1
Isolation| Ⅰ| Ⅰ
Moisture Protection| IP24| IP24
Design Pressure High (Psig)| 500| 450
Design Pressure Low (Psig)| 450| 400
Sound Pressure Level dB (A)| 54| ≤56
Sound Power Level dB (A)| 64| ≤66
Dimension (W/D/H)(approx in)| 33×13×21| 37×13×27
Dimension of Package (W/D/H)(approx in)| 35×14×24| 43×18×30
Net Weight /Gross Weight (lb)| 99/110| 130/141
Refrigerant Charge (lb)| R410A/2.8| R410A/3.85
Extra Refrigerant Charge above design length (oz/ft)| 0.21| 0.26
Connection Pipe| Design Length (ft)| 19| 26
Outer Diameter Liquid Pipe (in)| 1/4| 3/8
Outer Diameter Gas Pipe (in)| 1/2| 5/8
Max Distance Height (ft)| 20| 31
Max Distance Length (ft)| 39| 59
Installation Kit Catalog Number| LS1412GHSB| LS3858GSB

WARRANTY

SEA BREEZE AIR warrants the accompanying split air conditioner or heat pump system to be free of defects in material and workmanship for the applications specified in the operation manual and installation manual for a period of one (1) year on parts and five (5) years on compressor, valid from the date of original retail purchase in the United States or Canada. Labor is not covered under warranty.
If the unit exhibits a defect in normal use and is determined to be within the warranty period, SEA BREEZE AIR will, at its option, either repair or replace the unit free of charge within a reasonable time after the unit is returned.

This warranty DOES NOT cover

  • Damage, accidental or otherwise, to the unit while in possession of the consumer that is not a result of a defect in material in workmanship.
  • Damage caused by consumer misuse, tampering, or failure to follow all care and maintenance instructions in the manuals.
  • Damage to the finish of the case or other parts caused by water.
  • Damage caused by repairs or alterations to the unit by anyone other than a qualified technician.
  • Filter.
  • Freight and Insurance cost for the warranty service.

Warranty Activation Card must be completed and sent in to activate the warranty for the accompanying unit.