MARTEC TLDD34523WD Discus 10W Tricolour 20W-30W LED Downlight Instruction Manual

June 3, 2024
martec

Discus 10W Tricolour 20W/30W LED Downlight
Model: TLDD34523WD
Instruction Manual

TLDD34523WD Discus 10W Tricolour 20W-30W LED Downlight

LEASE READ THESE INSTRUCTIONS CAREFULLY BEFORE INSTALLATION. PLEASE
RETAIN INSTRUCTIONS FOR FUTURE REFERENCE.
Martec Pty Ltd
6 Austool Pl | Ingleburn, NSW W 2565
P: 02 8778 7500
F: 02 8778 7555
E: customerservice@martecltd.com.au

INSTALLATION

  • This unit must be installed and wired by a qualified electrical contractor
  • Ensue power is off at mains before wiring and installation
  • For maximum number per circuit breaker, use the recommended quantities as for a standard mains 50W lamp (or 100W R80)
  • Ensure that the area that the unit is to be fitted has a minimum height clearance of 50mm
  • Cut a suitable hole in the ceiling for each unit ensuring no positions are under joists, cables, pipes etc
  • Terminate cables at primary side of driver ensuring cable clamp is in place
  • Feed springs through the ceiling hole slowly releasing the unit up to the ceiling. The springs will hold the fitting in place
  • Fixture control gear/driver must be mounted above any insulation covering the luminaire
  • For indoor use Ta = 25°C

WATTGE & COLOUR SWITCHING

INSULATION

Thermal insulation clearance class IC-4 and IC-F covered; meaning that the Prime LED downlight can be covered entirely by insulation abutting or is within 100mm horizontally of the luminaire. And must meet the following requirements:

  • Be of a type that can maintain its dimensions and structural integrity when exposed to a maximum surface temperature the class of the luminaire, being 90°C;
  • Be of a type that can withstand a 30 second needle flame test carried out in accordance with AS/NZS 60695.11 with a flame applied to all surfaces of the sample insulation types which should be used with this fitting are glass wool (pink batts) & polyester.

IMPORTANT NOTE
This fixture must not be installed with loose fill insulation (as defined in NZS 4246) such as macerated paper and wool.
Fixture control gear/driver must be mounted above any insulation covering the fixture.

Aust/NZ Approval No.
SAA192480
www.martecaustralia.com.au
02 8778 7500
sales@gmartecltd.com.au