Scandia Series 1 Fraam Range Woodbox Owner’s Manual

July 2, 2024
SCANDIA

Scandia Series 1 Fraam Range Woodbox

SCANDIA FRAAM RANGE

Model Name

  • Fraam   Horizon SG010100011
  • Fraam Sheer SG010100021

INTRODUCTION

  • Congratulations on purchasing a genuine Scandia wood heater. When cared for properly, these high-quality, finely crafted wood heaters will offer many years of reliable performance.
  • This instruction manual has been developed to ensure optimum performance from your Scandia wood heater.
  • It’s very important that you thoroughly read and understand all instructions before using your new wood heater.

COUNCIL REQUIREMENTS

  • Check Local Council Requirements Eg. permits
  • When installing, operating and maintaining your wood heater, follow the guidelines presented in these instructions, and make them available to anyone using or servicing the wood heater.
  • Your cit_¼ town, state or territory may require a building permit to install a solid fuel-burning appliance.
  • Always consult your local building inspector or local council to determine what regulations apply in your area.

Please note: Your wood heater must be installed by a qualified person whose work conforms with local council regulations, Australian standards & manufacturers’ recommendations. Failure to do so will void your warranty and could void any home insurance.

WOOD HEATER SAFETY

When properly maintained and operated your wood heater should give you many years of service, however, there are important safety aspects of these products that you need to be aware of when operating a wood heater.

  1. This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge unless they have been given supervision or instruction concerning the use of the appliance by a person responsible for their safety.
  2. Children should be supervised to ensure that they do not play with the appliance.
  3. Never place combustible items such as but not limited to furniture, fabric or wood within the specified clearances to combustibles.
  4. The burning of wood gives off gases which can be extremely dangerous. Wood heaters are designed so that under normal operating circumstances these gases pass up the flue chimney system and cannot escape into your home, however, it is important that your flue system is properly installed and that you check all joints regularly to ensure that there are no cracks or gaps, check the door sealing rope and replace when damaged/worn. We recommend a smoke alarm be fitted in rooms where wood heaters are installed. Do not use your wood heater in a room where negative pressure conditions exist Negative pressure environments can cause products of combustion to be drawn from the fireplace into the room. Caution should be taken when using any form of extraction in a room where a wood heater is installed
  5. This appliance is designed to specifically bum dry hardwood Do not bum rubbish, driftwood, flammable liquids or any substance containing salts or corrosives.
  6. Creosote and soot may accumulate in your flue pipe and chimney. This may ignite, causing a chimney fire. If you suspect a chimney fire close down the air controls on the wood heater, if the fire persists evacuate people from the building and call the Fire Brigade. To prevent the accumulation of soot or creosote, check the flue and chimney regularly and clean as necessary. Good-burning, hot wood heaters will generally cause a lot less build-up than slow-burning wood heaters, likewise dry wood will cause less build-up than wet wood. We recommend a fire extinguisher be available where wood heaters are in operation. In the event of a chimney fire do not re-light the wood heater until the heater and the flue chimney system have been thoroughly checked and repaired/replaced as necessary.
  7. Wood heaters get extremely hot and should not be touched when lit. When young children are in the area, we recommend the use of a suitable fire guard around the wood heater. Always wear protective gloves when reloading the wood heater.
  8. Never over-fire your wood heater. If external parts of your wood heater are glowing red then the wood heater is over-firing and your draught settings should be reduced Never interfere with the draught mechanisms or adjust your air settings outside those limits set when the wood heater is manufactured Never use a secondary fan to supply or extract air to the wood heater.
  9. All users of the wood heater should be aware of the contents of this manual. Please leave this manual where it is accessible to wood heater users and do not allow anyone to use the wood heater who is unfamiliar with its correct operation.
  10. Never use the wood heater if any parts are missing or damaged, only use genuine parts as replacements. Never modify your wood heater.

BEFORE INSTALLING YOUR WOOD HEATER

You need to consider the following to ensure the safe operation of your wood heater:

  • Provision of adequate air to support efficient combustion of the fuel.
  • A well-sealed flue/ chimney system, hereinafter referred to as the “flue system”.
  • The protection of combustible materials in the proximity of the wood heater.
  • A suitable base on which to place your wood heater.u

ADEQUATE PROVISION AIR

  • It is essential for the safe and efficient use of your wood heater that you provide an adequate air supply to your wood heater.
  • This may mean the provision of an outside air supply to the room, especially if there are extraction units such as cooker hoods or clothes dryers in the vicinity. Failure to do so will mean that fuel is burned inefficiently causing smoke, blackening the glass and may also cause smoke to come back into the room. As a simple check for this open a door or window in the room and check if the wood heater bums more efficiently.

WELL-SEALED FLUE SYSTEM

  • Under no circumstances should you use aluminium or galvanized steel pipes for your wood heater flue. Always fit pipes with the narrow crimped side down, this allows any creosote to run down the inside of the pipe and not to come out and cause an unsightly mess and possible fire hazard.
  • Pipe bends should be kept to a minimum and we do not recommend using more than 2 bends on any installation. Flues must not pass through ceilings, floors, attics, roofs, or combustible walls without adequate and approved insulation being provided to protect combustible materials.
  • The chimney and flue provide a means of taking combusted fuel from the wood heater, as well as a draught to enable the wood heater to work. It is essential that the flue system is kept in good condition and there are no breaks or cracks allowing contact with any other combustible materials in the house. It is also essential that the flue system is kept clean and seals are maintained to ensure the draught is not lost
  • The open end of the flue system must be above the height of the apex of the building and any other obstructions, such as trees, which are within 3 meters (10ft) of the flue system. Failure to do this will affect the efficiency of the wood heater and may cause down draughts which will mean dangerous products of combustion are emitted into the room.
  • Under no circumstances should the flue pipe be less than 611 (152mm) internal diameter.

CLEARANCES TO COMBUSTIBLES

  • It is extremely important that you respect required installation distances and that you respect local installation regulations.
  • This is for your safety! The manufacturer is not responsible for the product if it is not installed following these recommendations. These clearances may only be reduced by means approved by the regulatory authority.
  • A combustible surface is anything that can bum (i.e. plaster, wallpaper, wood, fabrics etc.) These surfaces are not limited to those that are visible and also include materials that are behind non-combustible materials. If you are not sure of the combustible nature of a material, consult your local fire officials.

UNIT DIMENSIONS

HORIZON

SHEER

**** HORIZON SHEER
Freestanding Heater  
A **** Appliance width 950mm 518mm
B          Rear of the appliance to centre of the spigot 255mm 252mm
C          Depth overall (including handle) 586mm 586mm
D         Depth of firebox casing 505mm 505mm
E          Firebox casing height 521mm 725mm
F          Firebox case including pedestal 828mm 1097mm

FIREBOX ASSEMBLY

HORIZON – FIRE BRICKS

1         Top Baffle- Qty 2

2       Vermiculite Side Liner – Qty 2
3       Vermiculite Base Liner – Qty 4
4       Vermiculite Rear Liner – Qty1
5       Vermiculite Retainer – Qty 2

SHEER- FIRE BRICKS

1 Top Baffle – Qty 3
2 Vermiculite Side Liner – Qty 2
3 Vermiculite Base Liner – Qty 6
4 Vermiculite Rear Liner – Qty 2
5 Vermiculite Retainer – Qty 3

FIREBRICKS REMOVAL

  1. Remove firebrick retainers
  2. Remove rear firebricks
  3. Remove side firebricks
  4. Remove base firebricks

INSTALLATION

  1. Install side firebricks
  2. Install rear firebricks
  3. Install firebrick retainers
  4. Install base firebricks

BAFFLE REMOVAL

Caution: Wood heater baffles can be heavy. It may be best to have an experienced wood heater installer perform this task.

  1. Remove firebricks. Refer to ‘REMOVAL’ in ‘FIREBRICKS’
  2. Place both hands under the baffle and lift the baffle upwards approximately 20mm
  3. Move the baffle towards the firebox door, just enough to clear the rear locating lugs
  4. Tilt the baffle so that the back of the baffle is under the rear locating lugs and the front of the baffle is clear of the front locating lugs
  5. Lower the baffle to the floor of the firebox
  6. Rotate the baffle almost 90 degrees from its normal resting position and remove the baffle from the firebox

INSTALLATION

MINIMUM INSTALLATION CLEARANCES

FREESTANDING INSTALLATION CLEARANCES TO COMBUSTIBLES FOR FREESTANDING INSTALLATION

  HORIZON SHEER
A **** Side of heater to side wall 500mm 450mm
B **** Centre of heater flue to the rear wall 505mm 377mm
C         Rear of heater to rear wall 250mm 125mm
D         Front of heater to hearth front 600mm 300mm
E         Minimum hearth width 1175 mm 740mm
F          Minimum hearth depth 1100mm 805mm
G **** Rear corner of heater to wall N/A 350mm
H **** Minimum corner hearth depth N/A 1155 mm

All measurements are in ‘mm’

  • When using a Scandia decorative mesh flue kit. (Decorative flue is fitted with an additional heat shield)
  • “When using Scandia Sleek Black/ Graphite flue kit. (Sleek black/ Graphite flue is fitted with an additional heat shield)
  • Manufacturers recommendation: Keep all combustible materials at least 1.22 metres (4 feet) away from the appliance.
  • This includes rugs, fabrics, furnishings, papers, firewood, etc. NEVER dry clothing on or within 1.22 metres of the appliance.

FREESTANDING HEARTH REQUIREMENTS

  • Horizon:
    • A minimum 1100mm deep x 1175mm wide x 24mm thick floor protector (compressed board) should be used under and in front of the appliance base when installing the appliance (see joint AS/NZS 2918:2018 3.3.2).
    • The floor protector should extend 600mm in front of the appliance door and be placed centrally in the 1175mm width.
    • The Thermal resistivity of the floor protector is 0.0782m .K/W for 24mm thick compressed board sheets.
  • Sheer:
    • A minimum 805mm deep x 740mm wide x 6mm thick floor protector (compressed board) should be used under and in front of the appliance base when installing the appliance (see joint AS/NZS 2918:2018 3.3.2).
    • The floor protector should extend 300mm in front of the appliance door and be placed centrally in the 740mm width.
    • The Thermal resistivity of the floor protector is 0.026m2 .K/W for 6mm thick compressed board sheets.

FOR CONNECTING INTO A STANDARD FREESTANDING INSTALLATION USING SCANDIA FLUE KITS.

  • The following drawing is meant as a guide only. Your wood heater must be installed by a qualified person whose work conforms with local council regulations, Australian/New Zealand standards (AS/NZS 2918:2018) & manufacturers’ recommendations.
  • Scandia wood heaters are independently tested to Australian Standards using a Scandia-Aue kit, we always recommend using a Scandia-Aue kit when installing a Scandia wood fire.
  1. Locate the wood fire in its proposed position according to manufacturer recommendations.
  2. Use a plumb bob to mark the ceiling in line with the centre of the flue collar.
  3. Check that the outer casing will clear all combustible materials by 25mm. Determine positions of noggins to avoid cutting, otherwise, headers must be installed for strength.
  4. Cut a 305mm diameter hole in the ceiling. Directly above cut a hole in the roof to accommodate the outer casing.
  5. Fix the angle brackets to the joists so that the drop box (first length of located casing) is located in the centre of the hole.
  6. Position the drop box between the angle brackets, keeping a 25mm clearance to combustibles. The located end of the drop box must protrude no less than 150mm down from the ceiling or any combustible material. Fix the drop box to the angle brackets.
  7. Add the remaining casings to the required height Australian/New Zealand Standards state that “the flue pipe shall extend not less than 4.6m above the top of the floor protector”. If the flue pipe is within 3 metres of the ridge, the flue pipe must protrude at least 600mm above the ridge of the roof. If the distance from the ridge is more than 3 metres, the flue pipe must protrude at least 1000mm above roof penetration. Additional lengths of casing and flue may be required to achieve this. The flue pipe must be more than 6 metres from any nearby structure. Other clearances may be applicable, it is up to the installer to ensure compliance with all regulations. See Figures 1 and 2 on P7.
  8. Install roof flashing (Additional acceSSOf¼ not supplied in flue kit)
  9. Secure the Ceiling Collar in place using ceramic spacers and screws provided.
  10. Insert the crimped end of the upper decorative flue (without an internal stainless steel heat shield) up into the drop box. Then insert the crimped end of the lower decorative flue (with the internal stainless steel heat shield) up into the bottom of the upper decorative flue. The lower decorative flue features locating tags on the non-crimped end which rest on the heater flue collar. The solid heat shield section of the decorative mesh and stainless steel inner heat shield is to face the wall.
  11. Feed stainless steel flue through the decorative flue and drop the box through to the required height Assemble flue pipes tight as you go ensuring seams are straight Secure each joint with three stainless steel rivets or screws spaced equally. Clean any finger prints or oils off stainless steel flue with methylated spirits.
  12. Trim the inner flue to the same height as the outer casing. Place cover cone and cowl over stainless steel flue & push cover cone over gal casing. Fix the cover cone to the gal casing with stainless steel pop rivets or screws.

OPERATING YOUR WOOD HEATER

CONTROLS AND THEIR USE

AIR CONTROLS

  • Your wood heater needs air to bum the fuel. Scandia wood heaters draw air from multiple areas to maximize efficiency.
  • The air is supplied through an adjustable primary air slide at the front right side of the wood heater and secondary non-adjustable air through the rear of the firebox and air tube.
  • Primary air, as the name suggests, is used for the initial burning of the fuel and is also used to keep the stove glass clean. Secondary air is used for secondary combustion, which makes the stove more efficient and reduces emissions.
  • The settings of the primary air control very much depend on draught and local conditions and after a few fires, you should have a good idea of the best settings for your wood heater. The air slide control should be fully opened when lighting the fire.
  • Once the fire is established, the air slide control may be adjusted as required. Reducing the air intake will cause the wood heater to bum slower. This may cause some blackening of the stove glass, but this should bum off once the wood heater is burning brightly again.

FUEL
Your wood heater is designed to bum dry hardwood only.

It is NOT designed to bum the following:

  • Softwood
  • Treated or painted wood
  • Paper or cardboard, other than small amounts used to light the stove.
  • Plastics
  • Synthetic fuel or logs that are not approved for solid fuel stoves
  • Household rubbish
  • Liquid fuels

Burning these or other products for which the wood heater was not designed may damage the wood heater and cause a fire hazard or release toxic fumes. Fuel should be stored in a dry place; wood should be dried for at least 1 year and have a moisture content of less than 20%. Wet wood may cause serious creosote buildup, which may damage your flue system and even your wood heater. Therefore the use of green, sappy or wet wood is strongly discouraged.

WARNING: FIRST OPERATION OF STOVE

  • When operating, this unit will get extremely hot. Do Not Touch, use tools where necessary. You should begin using your wood heater by lighting small fires which get progressively larger.
  • We recommend lighting approximately 5 small fires before you put the wood heater into full service.
  • Allow the wood heater to fully cool between each of these fires. There may be some smell and a small amount of smoke from the wood heater during the initial operations.
  • This is perfectly normal and is merely the curing of the wood heater paint. Opening a window or door to provide additional ventilation will help alleviate this.

LIGHTING THE FIRE

  • Open the fire door, lay a few crumpled sheets of paper or firelighters on the firebox base then a few small dry pieces of sticks or kindling.
  • Open the air inlet controls. Now light the paper, close the fire door when the kindling has caught fire (allow about 10 minutes for this to happen) add larger pieces of dry wood, until the firebox is half filled.
  • When the larger pieces of wood have caught fire, add full-sized logs. Close the air controls to the point where the required bum rate is obtained.

REFUELING

  • Before refuelling your wood heater, turn the air supply to high for a few moments until there is a good fire in the heater.
  • This will ensure there is no build-up of harmful gases in the wood heater when the door is opened and will also get the new fuel burning quickly and not allow it to kill the fire. Open the door slowly in case any logs or coal have fallen against the glass.
  • Opening the door quickly may result in smoke being drawn into the room.
  • To reload the wood heater, open the door and feed the fuel in slowly always using either tongs or a small shovel along with protective gloves. Do not overfill the wood heater. It is always better to put in small loads often rather than big fills less frequently.
  • Wood should be loaded in a front-to-back direction, this helps air flow as well as reducing the risk of logs falling forward. Close the door gently after the wood heater is reloaded.

OVERNIGHT BURNING

  • Your wood heater is designed to maximise bum times. The best results are achieved when you establish a good fuel bed in the wood heater and allow it to bum for about 30 minutes before closing the air slide control fully.
  • When you return to your wood heater, fully open the air slide control until you have a good fire and then set it to normal operating levels.
  • Do not add fuel until the fire bed is hot and red Then add a little for the first time and allow that to ignite before adding more.
  • During overnight burning, the wood heater glass may blacken, but when a fire is established again this should bum off.

WOOD HEATER MAINTENANCE

CHECK YOUR WOOD HEATER REGULARLY

Initially, we recommend you check your flue system at least once per month. After the first few months, you will notice a pattern of soot and creosote build and you can then determine an inspection interval for checking soot and creosote build-up that is suitable for your wood heater installation. Other checks, as listed below should be carried out at least twice per year. If you notice anything wrong at any time it should be repaired immediately. Never use a wood heater that is in any way damaged or has a damaged flue.

  1. Check your flue system for build-up of soot or creosote and signs of damage to joints.
  2. To check the flue outlet remove the top of the baffle by lifting and pulling out at the end. Use a flashlight to check the flue outlet Clean and repair as necessary. Always replace the top baffle before relighting the stove.
  3. Check that the glass is not cracked or chipped and that the sealing rope is in good condition. Replace as necessary.
  4. When the room is dark, use a strong flashlight to check the sealing of the wood heater at the edge and comers for leaks. Any leaks or cracks found should be repaired with fire cement or damaged parts should be replaced with genuine spare parts.
  5. During periods of inactivity or infrequent use, regularly alternate the position of the flue damper. We also recommend placing a silica bag in the firebox to absorb any moisture which may cause rust
  6. Check that the wood heater door is tight and well-sealed when closed. Place a strip of paper into the wood heater and close the door, try to pull out paper. You should feel some resistance to your pull, and check several points around the door. If it pulls out too easily, replace the rope and seal in place with a suitable high-temperature sealant
  7. Check baffle plate and firebricks. Baffle plate should be replaced if a hole appears in the surface of the plate. Firebricks should be replaced when they start to crumble or the firebox is exposed.

ASH REMOVAL

  • When the stove is out and completely cold you may remove the ash using an ash vacuum or a steel bucket with a lid and shovel. Place a cover over the bucket so that when removing the bucket the ash does not blow about your house.

CARE OF GLASS

  • At times, especially when the air controls are turned to low settings or when damp wood is used, the wood heater glass will blacken. This is caused by fuel that is not completely burnt, but the build-up on the inside of the glass will normally bum off when a good fire is established in the wood heater.
  • There may be times however when you need to clean the glass. To do this, use a soft cloth and a non-abrasive glass cleaner.
  • Only ever clean the glass when the wood heater is cold For best results select from Scandia’s range of glass cleaning products. When loading fuel into the wood heater, always make sure it is not protruding out through the door opening, as this may break the glass when you close the door. This is especially relevant when loading logs. Always close the door gently.
  • If the glass does crack when the wood heater is lit, let the fire die out Do not open the door until the wood heater has fully cooled Replace the glass with the specified replacement part before re-using the wood heater.

REPLACING PARTS

  • Always use genuine replacement parts. Only ever make replacements when the wood heater is cold
  • All replacement parts can be ordered from www.scandiastoves.com.au.

SURFACE FINISH

  • To clean your heater wipe lightly with a damp cloth or dust with a duster. Some cleaning products may leave stains on the wood heater surface. Never use abrasive cloths as these may scratch the surface; take caution when using microfiber cloths as they can leave swirl marks if used in a circular motion. Painted wood heaters can be re-painted by using a good quality “t¼ high-temperature wood heater paint When re-painting, make sure there is plenty of ventilation and follow the manufacturer’s instructions.
  • Allow the paint to fully dry before lighting the stove and allow extra ventilation for the first couple of fires as some fumes may emit from the stove as the paint cures.
  • Scandia high-temperature enamel is available at your local Scandia retailer. Visit www.scandiastoves.com.au for details.

TROUBLESHOOTING

  • Many people underestimate the importance of using a professional installer with experience in wood heating who adheres to Australian Standards to install their wood fire.
  • If you are having issues with your wood fire not working the way you think it should, we implore you to speak to your installer first; they can help you with issues such as burning too much or too little wood, smoke in the room when you open the door; blackened glass or build-up of creosote during use. A professional installer can also guide whether the problem is a manufacturing issue; in this instance, we will work with the contractor to resolve any issues as soon as possible for you.
  • It is important to remember that all flue installations must be compliant with Australian Standards. A heater installed with a non-compliant flue configuration will not perform as advertised or as tested.

FIRE NOT BURNING

A wood heater not burning is generally caused by either a shortage of air and/ or incorrect or damp fuel.

If fuel is not the problem check:

  1. That the air controls are opened.
  2. There is no blockage in the flue system.
  3. That the open end of the flue is above the height of any nearby obstructions.
  4. That there is a sufficient air supply into the room and that this supply is not being taken by an extractor fan.

GLASS BLACKENS Glass usually blackens when:

  1. GLASS BLACKENS Glass usually blackens when:
  2. Bad quality or damp fuel is being used
  3. Please note: For optimum efficiency always use good quality dry hardwood.

FIRE BURNING TOO QUICKLY This is usually caused by too much draught or air.

  1. Firstly try reducing the air supply to the wood heater by closing down your air controls, if this fails then you may have to adjust the door or you may have damage to the sealing.
  2. Close a thin strip of paper in the door, check to see if the paper stays in place or pulls out If the paper pulls out easily you may need to adjust or replace the door seal.
  3. Check to see if the glass moves within the door frame. If it does you may need to tighten the glass retainer screws.
  4. Check the condition of the door sealing rope and the glass seal tape.

SMOKE IN ROOM

  • If the wood heater is properly installed it should not emit any smoke into your room. Should this happen, check that your room is not air tight This can easily be checked by opening a door or window.
  • If the smoking stops you need to provide an additional air supply into the room.
  • If this is not the problem, check if your chimney is blocked or obstructed and that you are not getting a down draught caused by the location of the open end of the flue pipe or chimney.
  • If the problem persists contact your installation company and ask them to get your chimney and stove installation checked

CHIMNEY FIRE

  • Chimney fires occur when soot and creosote that have built up in the flue system ignite. If the wood heater is operated properly and the flue checked and cleaned regularly then chimney fires should not occur.
  • These fires can be very dangerous and must be avoided Try to maintain good, hot fires in the wood heater whenever possible and at least once in every firing open the air controls and allow the wood heater to bum on full for a short while until the entire fire bed is glowing red Check your flue system regularly for build-up of soot and creosote and clean as necessary.
  • Chimney fires can be detected by sparks coming from the top of the chimney, a roaring sound coming from the area of the stove or chimney or vibration in the stove or chimney.
  • In the event of a chimney fire, close the air controls, evacuate the building and call the fire department Do not relight the stove after a chimney fire until the stove and flue have been checked and any necessary repairs have been carried out

WARRANTY

SCANDIA LIMITED WARRANTY

  • This limited warranty is given by Scandia Heating (Aust) Pty Ltd (ACN 005 868 093) (Scandia or we) to the original retail purchaser (you) of the wood heater to which this Warranty applies.
  • Our goods come with guarantees that cannot be excluded under the Australian Consumer Law. You are entitled to a replacement or refund for a major failure and for compensation for any other reasonably foreseeable loss or damage.
  • You are also entitled to have the goods repaired or replaced if the goods fail to be of acceptable quality and the failure does not amount to a major failure.
  • The benefits that this Warranty provides are in addition to other rights and remedies available to you under the Australian Consumer Law. This Warranty does not limit those rights and remedies.

SCOPE OF WARRANTY

If a defect in material or workmanship appears in the following parts within the corresponding warranty period after the date of the original purchase, such as to make the wood heater unfit for normal home use; and you comply with the requirements below regarding making a claim, then, subject to the exclusions below “¼ we will replace or repair the relevant part or (at our option) replace the entire wood heater with the same or comparable model.

To the extent permitted by la’¼, our liability under this Warranty is limited to this replacement or repair obligation.

IMPORTANT

For this Warranty to apply, you must fully complete the Warranty Registration Form via scandiastoves.com.au/warranty. Alternatively, you can complete the Warranty Registration Card and mail it to our mail address (below) within 30 days after the original purchase. By completing this form, you also agree that to the extent permitted by la\¼ our liability to you on any basis to the wood heater (other than under the Australian Consumer Law) is limited to our obligations under this Warranty.

EXCLUSIONS This Warranty does not apply:

  1. Where the defect is not due to the original design or manufacture of the part (including where the wood heater, part or accessory has been subject to accident, abuse, alteration, misuse or neglect or has been installed, inspected, operated or maintained negligently or not by applicable local laws and regulations and the manufacturer’s printed instructions, if any)
  2. Where the firebricks, top baffle or fibreglass seal have not been replaced after becoming damaged or worn
  3. To any accessories or optional parts
  4. To any glass, paint, firebrick, or fibreglass seal sold or used with the wood heater
  5. To any surface rust which may occur in transit, storage or use. This includes installations near coastal areas and salt water which may cause rust to the appliance.

HOW TO MAKE A CLAIM

Any claim under this Warranty must be in writing to our mail address below. It must be sent within the applicable warranty period and must state:

  1. The model and serial number of the wood heater
  2. The place, price and date of purchase
  3. Reasonable details of the defect

To obtain replacement or repair under this Warran? the wood heater must be returned to the original place of purchase (and collected from there once the replacement or repair is complete) at your cost Scandia will not be responsible for any associated freight, disconnection or re-installation costs (including labour costs). Scandia will only be responsible for transport of the wood heater from the original place of purchase to Scandia’s premises (and back), and replacement or repair in accordance with this Warranty.

REGISTER YOUR PRODUCT

  • REGISTER ONLINE
    • Register your product warranty online by visiting: www.scandiastoves.com.au/warranty.
    • Your data will be used by Scandia to provide you with information about your purchase upon request
  • REGISTER BY MAIL
    • Alternatively, please complete the attached warranty card within 30 days of installation and return to:
    • Scandia Group Pty Ltd
    • 58 Access Way, Carrum Downs
    • Victoria, Australia, 3201.

FRAAM HORIZON SPARE PARTS

SPARE PARTS

LEGEND PART QTY SCANDIA PART NO.
1 Fraam Horizon Door Assy 1 SG031000157
2 Set Vermiculite Firebricks For Fraam H 1 SG030600041
3 Styliste 10 Brick Retainer Corner 2 SPSTY111
4 Door latch 2 SPMR512B
5 Fraam Horizon Ash Lip 1 SG030700496
6 Frame H Centre Baffle Support 1 SG030700503
7 SC Fraam Heater Fan 1 SG030700628
8 Fraam Baffle Plate 2 SG030700911
9 Fraam Horizon Air Slide 1 SG030700912
10 Kit Fasteners Air Slide 3 SG031300118
11 Frame Door Hinge 1 SG030700500
12 Brick Retainer Rear 1 SPSTY112

DOOR ASSEMBLY SPARE PARTS

LEGEND PART QTY SCANDIA PART NO.
1 Door Glass 871 mm x 410 mm x 5 mm Fraam Horizon 1 SG031000166
2 Glass Seal 20 mm x 3 mm x 2500 mm 1 SG030400030
3 Bottom Glass Retainer Fraam Horizon 1 SG030700928
4 RHS Glass Retainer Fraam Horizon 1 SG030700930
5 Door Locking Mechanism Fraam Horizon 1 SG031000167
6 Door Seal 20 mm Diameter x 2250 mm Length 1 SG030300026
7 Top Glass Retainer Fraam Horizon 1 SG030700929
8 LHS Glass Retainer Fraam Horizon 1 SG030700931

FRAAM SHEER SPARE PARTS SPARE PARTS

LEGEND PART QTY SCANDIA PART NO.
1 Fraam Sheer Door Assembly 1 SG031000155
2 Set Vermiculite Firebricks For Fraam SH 1 SG030600040
3 Door latch 2 SPMR512B
4 Brick Retainer Corner 2 SPSTY111
5 Fraam Sheer Ash Deflector 1 SG030700316
6 SC Fraam Heater Fan 1 SG030700628
7 Fraam Baffle Plate 1 SG030700911
8 Fraam Sheer Airslide 1 SG030700318
9 Kit Fasteners Air Slide 2 SG031300118
10 Frame Door Hinge 1 SG030700500
11 Brick Retainer Rear 1 SPSTY112

DOOR ASSEMBLY SPARE PARTS

LEGEND PART QTY SCANDIA PART NO.
1 Door Glass 6105 mm x 434 mm x 5 mm Fraam Sheer 1 SG031000179
2 Glass Seal 20 mm x 3 mm x 2000 mm 1 SG030400036
3 Bottom Glass Retainer Fraam Sheer 1 SG030700991
4 RHS Glass Retainer Fraam Sheer 1 SG030700993
5 Door Locking Mechanism Fraam Sheer 1 SG030700969
6 Rope Seal 20mm Diameter x1760 mm Length 1 SG030300023
7 Top Glass Retainer Fraam Sheer 1 SG030700992
8 LHS Glass Retainer Fraam Sheer 1 SG030700994

CONTACT

SERIES 1

  • Fraam Horizon SG010100011
  • Fraam Sheer SG010100021

Scandia Group Pty Ltd

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

SCANDIA User Manuals

Related Manuals