Congratulations on the purchase of your Scandia Ultra-Sauna electric
heater!
Since 1964, Scandia Manufacturing has been making the best sauna heaters in
the industry. Each heater is handcrafted and individually made by an expert
technician. They are not mass-produced; we consider each heater a work of art.
To ensure your satisfaction with our heater we suggest you read through this
guide and familiarize yourself with:
- Installation Instructions
- Electric Heater Component List
- Warranty Information
- Troubleshooting Guide
Safety First
You must consult a licensed electrician to assist you with the installation
and connection of your Scandia Ultra-Sauna. Self-installations will void your
warranty.
When you receive your heater, you should inspect it within 48 hours to verify
all parts, materials, and instructions are there. Scandia is not responsible
for replacing or warranting items that are not reported within 5 days of
receipt of your shipment.
If your shipment is damaged please retain all packaging and call us
immediately Prior to installation, the installer (licensed professional)
should check all connections and parts to ensure proper fitting. These items
may have come loose in shipping.
You can rest assured knowing that your unit was tested in our production
facility prior to shipping to ensure proper working order. Loose connections
and/or improper installation are the most common reasons for your unit not
heating up right away.
Do not call the manufacturer until a licensed professional has checked to
ensure proper connection.
The heater must be installed with a heater guard rail – see instruction for
proper clearances.
Caution signs are included for your safety.
The recommended ceiling height is 7 feet, ceiling height should never exceed 8
feet.
IMPORTANT! READ BEFORE YOU START
-
The heater and controls must be installed by a licensed electrician.
-
The heater must be installed according to local codes.
-
Heater controls must never be installed inside the sauna room.
-
Heater controls should never be placed near water.
-
Scandia heaters are wall-mount heaters and must be installed accordingly.
-
Ensure that the thermostat sensor is properly installed inside the room (except for T-model heaters).
-
Ensure all factory connections are tight as wires may have come loose in shipping.
Torque to proper specifications. -
Heater should not be operated without recommended amount of rocks. Use only Scandia’s supplied rocks.
-
The warning signs and sauna usage plaque must be displayed.
-
The sauna room must be vented according to the manufacturer’s specifications or Scandia’s Installation Instructions.
-
Plastic must be removed from the heater body before operating the heater.
-
The heater should not operate without a specified heater guard.
-
Plastic must be removed from the shell before operating the heater.
-
The sauna door must always open outward.
-
Sauna door can never include a lock
GENERAL SAUNA ROOM GUIDELINES
-
The sauna room must be properly constructed and well-insulated according to sauna kit installation guidelines, including the following recommendations:
-
Sauna room interior should be finished entirely with kiln-dry, softwoods such as Clear Western Red Cedar.
-
Sauna room walls should not include the following finishes: ceramic tile, rock, or any material that will retain heat in the walls as this can cause the heater to overheat.
-
The sauna room must be properly vented.
-
The sauna door must always open outward.
-
Sauna door can never include a lock.
-
The heater must have a heater guard made according to Scandia’s specifications.
Never put a heater in a cove where airflow is restricted. -
Industry-standard- Recommended sauna ceiling height is 7ft (84”). Anything above 8ft (96”) please inform us ahead of time to correctly size the heater based on the cubic feet.
-
GENER AL USAGE, CARE AND MAITENANCE
-
Do not touch the heater while in operation.
-
Do not cover the heater.
-
Do not hose down the sauna room or heater.
-
Check and clean rock tray monthly or as needed.
-
Refer to our complete usage, care, and maintenance guidelines available on Scandia’s website.
-
TROUBLESHOOTING GUIDELINES
-
Troubleshooting guidelines are available on Scandia’s website. If you need additional assistance, please consult your certified professional first, then submit a technical ticket via the website if further assistance is needed www.scandiamfg.com/contact.
BEFORE YOU START
- Heater and controls must be installed by a licensed electrician
- The heater must be installed according to local codes.
- Ensure all factory connections are tight. Wires may have come loose in shipping.
- Plastic must be removed from the shell before operating the heater.
- The sauna door must always open outward.
- Sauna door can never include a lock.
YOUR HEATER SHOULD INCLUDE
- Controls with complete Installation Instructions
- Main Heater Unit
- Sauna Rocks
- Thermostat sensor wall cover (not included with T-model heaters)
- Warning Sign
SAUNA HEATER SIZING
Ultra Sauna Heaters—Large (26″ W x 18″ D x 29″ H)
Model| Watts| Volts| Phase| Amps| Max Room Size
12240| 12000| 240| 1| 50| 980 cu ft (2775 cu m)
12240-3| 12000| 240| 3| 29| 980 cu ft (2775 cu m)
12208| 12000| 208| 1| 577| 980 cu ft (2775 cu m)
12208-3| 12000| 208| 3| 33.| 980 cu ft (2775 cu m)
15240| 15000| 240| 1| 63.| 1428 cu ft (40 cu m)
15240-3| 15000| 240| 3| 36.| 1428 cu ft (40 cu m)
15208| 15000| 208| 1| 72.| 1428 cu ft (40 cu m)
15208-3| 15000| 208| 3| 42.| 1428 cu ft (40 cu m)
18240| 18000| 240| 1| 75| 1680 cu ft (476 cu m)
18240-3| 18000| 240| 3| 43.| 1680 cu ft (476 cu m)
18208| 18000| 208| 1| 87.| 1680 cu ft (476 cu m)
18208-3| 18000| 208| 3| 50| 1680 cu ft (476 cu m)
18480-3| 18000| 480| 3| 22| 1680 cu ft (476 cu m)
SAUNA HEATER SIZING GUIDELINES
- Minimum and maximum room sizes are based on a 7-foot ceiling height
- A properly sized heater will bring the room temperature to desired level in approximately 30 to 60 minutes
- An undersized heater may experience instances of overheating
- The maximum room-sized is based on the heater bringing the room temperature from 60 to 180 in 60 minutes
- The sauna room must be properly vented for heater to work effectively
SAUNA ROOM VENTING GUIDELINES
The sauna room should be vented according to the manufacturer’s specifications or Scandia sauna room specification found in the Scandia sauna installation instructions. Improper ventilation is dangerous for the sauna user’s health. When the door is undercut, there is no other venting required in small sauna rooms. You should have between 3/4” to 1” between the finished floor and the bottom of the door. If further venting is preferred or required, the inlet vent should be below the heater, or near the base of the heater.
RECOMMENDED SAUNA ROOM VENTILATION
Proper venting and positioning of the sauna vent is going to result in a
more comfortable sauna experience.
The intake vent in the wall should be located immediately behind the heater as
low as possible to the floor. Whenever the heater is on, some outside fresh air
will be pulled into the low-pressure area under the heat. As the hot air rises
through the heater, new air must move to replace it under the heater.
The vents should be adjustable with louvers.
The sizes of vents may vary, the typical standard size that is found in most
hardware stores is a 4”x10” floor vent.
SAUNA HEATER GUARD R AIL PL PLACEMENT GUIDE
The minimum dimensions of the heater guard must be 27” W x 19” D x 36-1/4” H –
Top rail of the guard must be below heater vent.
SCANDIA ULTRA – SAUNA HEATER GUARD R AIL
Components for 3-sided heater guard:
• 2x 2×2 corner posts / legs
• 3x 1×4 rails long piece rails for the front
• 6x 1×4 short piece rails for each side
• 2x Wall brackets
• Misc. screws
2-sided heater guard will have 1 post and one side only.| Heater guard rail
installation:
• All components come ready to be assembled
• Observe distances around heater for guard rail, walls, benches, and other
obstructions
• Follow the heater manufacturer’s clearances recommendations.
• Do not cut down the heater guard to fit!
---|---
CONTROL PANEL MODELS AND SIZES
CONTROL PANEL LOCATION
All controls must be mounted on the outside of the sauna, NEVER inside the
room.
RESIDENTIAL INSTALLATION – For convenience, place the control box at eye
level by the door, approximately 12” from the door opening and 42”
from the floor (see fig. 1). For conduit and wire size, type and quantities, see
specific heater wiring diagram charts.
COMMERCIAL INSTALLATION – For a 60-min timer, follow the residential
installation recommendations. For a 24-hour timer, you may place the control
panel either in front of the sauna or in the mechanical or electrical room
away from the sauna room. Please note that the thermostat capillary tube is
only 4 ft long, therefore for controls placed away from the sauna, we
recommend T-model heaters, where the thermostat is built in the heater itself.
STANDARD HEATER/CONTROL CONFIGURATION
Note:
All Ultra-Sauna heaters can be ordered as T-model from the factory. T-model
heaters have the thermostat built into the heater, eliminating the need to
have the thermostat sensor in the wall.
Important Notes
- Heater must be installed by a licensed electrician.
- The heater must be installed inside the sauna room and mounted 10-12” from the floor.
- Controls must be installed outside of the sauna room.
- The thermostat capillary sensor bulb must be located inside the sauna room (horizontal position) approx. 10 inches from the ceiling.
- All wiring must comply with Local and State ordinances: all wiring in the sauna the room must be rated for at least 90 degrees Celsius (194 degrees Fahrenheit)
- The standard sauna ceiling height is 7 feet.
- Consult all local codes before installation.
- Warning signs must be installed at eye level on the door and above the heater.
- The door must always swing outward.
- An air intake vent must be installed below the heater.
- The thermostat should be placed behind the cover and out of reach from guests/members.
The setting should be no higher than 180° Fahrenheit (85 Celcius)
WIRING DIAGRAMS
B3 CONTROL
For supply connections and control panel to heater connections, use wires suitable for at least 194° F (90° C)
A3 CONTROL
E2 CONTROL-THREE PHASE
E2 CONTROL-SINGLE PHASE
E2T CONTROL
Converting the 60-minute timer to 24 hr programmable timer.
Control Box
- Line feeds from Contactor connect to L1 & L2 on a timer.
- T1 connects in series to the Thermostat and to the left coils of both contactors.
- T2 pig-tails connect to field high-limit wiring, which will return back to right side coils of both contactors.
SAUNA HEATER OPERATING INSTRUCTIONS
Installation steps:
- Remove the protective cover off the heater shell.
- Hang the heater in place or as specified by the manufacturer.
- Fill the heater rock tray with the sauna rocks. Note: This sauna heater should not be operated without the recommended quantity of rocks.
- ENSURE GOOD AIR CIRCULATION AROUND THE SENSOR BULB.
Install the heater guard rail around the heater. After installation is completed, the heater should be turned on to maximum temperature for one hour to break any rocks with fault lines and to burn off the protective coating on the heater elements.
Do not enter the sauna room during the initial start-up. The smell of smoke and cracking of rocks will not re-occur.
Sauna Timer:
Scandia’ Sauna controls come with a standard 60-minute timer (wall mounted
outside the sauna) and thermostat. For T models, the thermostat is located on
the heater.
To turn on the heater, turn the timer knob up at the desired time (up to the
60 min. mark).
Leave the knob at the setting and the sauna will operate for one hour before
shutting off automatically. Allow 30 minutes for the room to heat up to an
average sauna temperature.
The thermostat is marked with numbers 1 through 10. With 1 being the coolest
temperature and 10 the highest. Set the desired temperature.
Note: Make sure the thermostat is on before setting up the
time,otherwise the heater will not heat up.’’ For 24-hour timer operation, see
attached Operating Guidelines for the 24-hour digital timer.
Product Liability:
The buyer acknowledges that the goods sold to them by Scandia Manufacturing
can cause property damage and personal injury if not properly sized, handled
or installed.
The buyer further agrees to indemnify and hold harmless Scandia Manufacturing
from any or all claims for damage, loss and/or liability arising out of
improper handling, sizing, and/or installation of goods.
PROGR A MING INSTRUCTIONS
24 digital hour timer
To set or change the day and time:
To clear the entire memory, press the RESET key.
Hold down the CLOCK key while pressing either the DAY, HOUR, or MINUTE keys.
Continue pressing until the desired day or number is shown. Then simply lift
the finger off of the CLOCK key to set.
To set program ( ON/OFF times):
Press the TIMER key once to enter into program mode. The display will show “1
ON—-” press the DAY key to choosing any of 15 different day combinations for
the first ON time.
Note: days of the week with the same program should be copied by
selecting the desired combination of days.
Press the HOUR key and then the MINUTE key to select the desired first ON time.
Press the TIMER key once. The display will show “1 OFF—-”. Repeat the previous
step to select the desired OFF time. Repeat the entire sequence to complete up
to eight ON/OFF times as desired.
When programming is done, press the CLOCK key and then the MANUAL key
repeatedly until the indicator bar is above the word “AUTO”
To Review Program:
Press the TIMER key repeatedly. When done, press the CLOCK key to return to
the time of day.
To Cancel/Change Part of the Program:
Press the TIMER key repeatedly until the particular ON or OFF time appears,
then repeatedly press the DAY key until the display shows “ – – – – “ Set new
ON and OFF time. ( See: To Set Programs )
To Override Automatic Operation:
Press the MANUAL key to move the indicator bar to the desired ON or OFF
position.
Note: Timer will not resume automatic operation until the indicator bar is
repositioned above the word AUTO.
SAUNA MAINTENANCE
DAILY
- Wait for the sauna to cool before entering the sauna to conduct a cleaning
- Use a bucket of warm water with a mild detergent (a liquid soap is sufficient) and a clean sponge or rag to wipe the bench surfaces.
- Do not use petroleum-based detergents. They can discolor your wood and will leave a residue that could emit irritating fumes.
- Wet mop the tile or cement floor.
- If something unpleasant other than ladled water is applied to the heater’s rocks, clean them after they have completely cooled. Soak them in a soapy (light detergent) mixture of warm water. Wash off with a sponge, then rinse the heater trough. Clean the heater and trough of the foreign substance. Gradually build heat in the sauna to totally dry the rocks.
WEEKLY
Take a rag and soapy water and wipe down benches and heavily used wall areas.
(Do NOT take a hose to a sauna at any time.) Inspect benches for broken
boards, tighten loose screws, and make sure benches are firm.
There should be a thermometer/hygrometer in the sauna room at all times to
show temperature and humidity for members’ safety.
EVERY 6 MONTHS-ONE YEAR ( DEPENDING ON USAGE )
Take an orbital sander and lightly sand benches and walls to take off thin
layer of discolored wood. Directly after use Scandia Essential Wood Oil and
apply to sanded area. Wood oil comes in gallon jugs and can be purchased
through Scandia’s website.
HEATER CARE
WEEKLY
Remove and inspect all stones and clean the trough. If a stone is broken throw
it away.
If broken stones are allowed to remain in the trough they will break down into
a sandy grit.
That grit will eat a hole in the stainless steel. This damage is not covered
by the warranty.
MONTHLY
Wipe down the heater shell to clean up any water stains.
NEVER EVER TURN A HOSE ON THE SAUNA TO WASH IT DOWN. IT WILL DAMAGE THE HEATER’S ELECTRIC COMPONENTS.
ULTRA SAUNA-WARRANTY
Your Ultra Sauna heater has been engineered and built to the highest quality standards, and is backed by this warranty to assure your complete satisfaction:
- SCANDIA Mfg warrants on the terms and conditions set forth below for ten years to the Original Owner only, at the Original Installation site only, this equipment to be free from defect in material and/or workmanship under normal use as specified in the equipment’s instructions, FROM DATE OF PURCHASE and thereafter.
- A TEN YEAR LIMITED WARRANTY applies only on the heater unit as manufactured by and at SCANDIA, – Manufacturing Plant — and specifically excludes all components and/or parts which are accessories therein, namely: the gas valve; pilot generator, heating element, contactor, timer switch, thermostat, and, high limit, for which their respective manufacturer’s warranties apply. The TEN YEAR LIMITED WARRANTY does not apply for units that have been installed in commercial locations such as clubs, condominiums, apartments, spas, or military facilities. In commercial locations, Scandia will provide a one-year warranty on the unit.
- During the first year, SCANDIA will, at its option, repair or exchange at the Factory all parts that it finds have become inoperative during said warranty period due to a defect in material or workmanship, without cost to the customer except for freight and/or crating charges.
- For the period commencing with the second year and for the ten year warranty of the original purchaser only, at the original installation only, SCANDIA will, at its option, repair or exchange at the Factory, all parts which it finds have become inoperative during the said warranty period due to a defect in material or workmanship except the following parts which are excluded from this warranty: the gas valve, pilot generator, heating element, contactor, timer switch, thermostat, and, high limit.
- This warranty in its entirety becomes null and void if the unit is rented or to be used for rental purposes or installed in any mobile or fixed prefab rental room. If the original purchaser is a corporation then, the president of said corporation shall be construed as registered Original Owner for all purposes herein, otherwise, this warranty in its entirety becomes null and void.
- This warranty in its entirety becomes null and void if the unit has been installed by an unlicensed party by and/or in the city and/or county where installation is made. Furthermore, if the unit is disassembled and/or tampered with in any way possible by anyone (individual and/or company) then this warranty in its entirety becomes null and void.
SCANDIA reserves the right to substitute new equipment or parts on any orders for replacement hereunder, but shall not be obligated to do so. This warranty is solely for the benefit of the original purchaser and no one else, and only if the installation and operating instructions applicable to the model purchased are followed. These instructions are furnished with the unit and also are available by writing SCANDIA’s warehouse. These instructions are incorporated herein by reference as if set forth in full. This warranty does not cover damages that appear to SCANDIA to have resulted from neglect, alteration, abuse, misuse, accident, flood, fore or other act of force majeure, or other than normal use.
This warranty is expressly in lieu of other warranties, or liabilities, express or implied, by the Company or its representatives, and in lieu of all other obligations and liabilities for damage to persons or property caused in any manner by the heater or its component parts. More specifically, by not by way of limitation, SCANDIA assumes no liability for damages which may occur as a result of neglect or intentional misuse of the unit, and the purchaser or user of the unit agrees to assume all liability for the consequences of its use or misuse by such purchaser or user, and his, its or their respective employees and agents or another third person. THERE ARE NO WARRANTIES THAT EXTEND BEYOND THE DESCRIPTION ON THE FACE HEREOF. NO REPRESENTATION OR WARRANTIES ARE MADE, EXPRESSED OR IMPLIED, OTHER THAN THOSE EXPRESSLY HEREIN SET FORTH TO THE ORIGINAL PURCHASER ONLY.
To obtain the benefits of this Warranty, the inoperative parts and/or complete
heater must be sent to Scandia, all shipping and crating charges prepaid. And
all repaired or replaced parts or heaters will be returned freight collect.
This warranty is effective only when the attached Factory Registration Stub is
completed and returned to the manufacturer. Please contact Scandia for return
authorization at 877-467-2862 or via
e-mail at info@scandiamfg.com
Warranty stub must be mailed or completed online within thirty DAYS TO
REGISTER AND VALIDATE THIS WARRANTY, WHICH BECOMES the VALID ONLY IF THE
HEATER HAS BEEN PURCHASED DIRECTLY FROM SCANDIA MFG., AND/OR AUTHORIZED
DEALERS IN U.S.A., its territories or possessions.
TO VALIDATE WARRANTY VISIT
WWW.SCANDIAMFG.COM/PRODUCT_REGISTRATION.HTML
AND REGISTER YOUR PRODUCT. ALL PRODUCTS MUST BE REGISTERED PRIOR TO ANY
WARRANTY CLAIMS.
TECHNICAL SERVICE TICKET
TODAY’S DATE:
CUSTOMER NAME
CONTACT PHONE NUMBER
MODEL
SERIAL NUMBER
VOLTAGE SUPPLY
CIRCUIT BREAKER SIZE
AMPERAGE DRAW PER ELEMENT
PHYSICAL SIZE OF ROOM:
DEALER NAME
PURCHASE DATE
STATE PROBLEM AND/OR COMMENTS:
*Photo images of the control wiring, junction box wiring, heater placement, and thermostat may be required to complete the analysis.
SCANDIA ULTRA SAUNA ELECTRIC HEATERS TROUBLESHOOTING GUIDE
All service and repairs must be performed by certified personnel and must use
Scandia certified components.
In order to effectively troubleshoot your Scandia Ultra Sauna heater, it is
important to check the parameters of the installation first. Please check the
below points and proceed based on your answers. This guide should lead you to
the exact problem of your heater and suggest the most efficient resolution to
the problem.
Check the following:
-
If the appropriate breaker in the circuit panel is in the on position.
– If not: turn it on.
– If yes: check #2. -
Make sure the base of the heater is at least 10” from the floor of the sauna.
– If not: reposition the heater to the correct height.
– If yes: check #3. -
When turning the sauna on, with the timer on, turn the thermostat on and then off, and make sure you hear the thermostat engaging the heating system (you will hear a click or clunk sound).
– If no: go to Thermostat Section
– If yes: check #4. -
The heater guard-rail is not blocking airflow of the heater (at least 6” from out-vents)
– If no: realign heater guard-rail to appropriate parameters.
– If yes: check #5. -
The sauna room is vented with one intake vent located below the heater and one exhaust vent located on the other side of the room below the upper bench or at least knee-high.
– If not: install appropriate venting
– If yes: check #6. -
Fuses in the fuse box are blown (for 15 and 18 KW versions only).
– If fuses are blown: replace appropriate fuses
– If not: check #7. -
Check that each element is supplied by opposing phases (or leads).
A heater element cannot be supplied by the same phase. This will destroy the element.
– If not: contact an electrician or the original installer to correct the wiring sequence immediately. This condition can result is serious damage to your heater and possible fire hazard.
– If yes: Go to High-Limit Section
PLEASE PROVIDE THE FOLLOWING INFORMATION:
- Breaker amp rating:
- Heater distance from floor:
- Circle the sound made when engaging the heating system: Click/Clunk
- What is the guard rail distance from the heater:
- Describe ventilation:
- Fuse amp rating:
- Describe phase sequence:
HIGH LIMIT SECTION
Please check all seven parameters on page one of this guide before proceeding
to this section.
The high-limit switch is located at the base of the sauna heater body. The red
button protrudes from the bottom junction box. This red button resets the
high-limit switch when tripped. The high-limit switch is a safety feature that
shuts down your sauna when the timer and thermostat fail to shut down the
heater. If the high-limit switch is turning off your heater, this means your
thermostat is not controlling the temperature as it should – or – the high-
limit switch is turning off your heater prematurely (before the thermostat
turns it off).
Note: Before proceeding, make sure you have tested the thermostat as
described in step #3 on the cover page.
If your high-limit switch is prematurely shutting down your heater, therefore
not allowing your thermostat to regulate the heat, your high-limit sensor bulb
may need to be adjusted. Please call our technical support team to help with
this issue.
THERMOSTAT SECTION
Please check all seven parameters on page one of this guide before proceeding
to this section.
The thermostat can be located on the control panel outside of the sauna room
or directly at the base of the sauna heater. The thermostat controls the
temperature of the room. Because of varying room constructions, room sizes,
materials, and altitudes … the thermostat works on a 1 to 10 basis rather than
an actual temperature reading. The 10 setting on the temperature should be
equivalent to 180 – 190 degrees Fahrenheit. If the sauna heater is being
turned off (or controlled) by the high-limit (not thermostat), this does not
mean your thermostat is faulty, it could be that your high-limit switch must
be adjusted. If so, see the high-limit section of this guide.
Thermostat Integrity Check – to check thermostat functionality: reset high-
limit (only if tripped) and turn on the sauna timer (if equipped with a
24-hour timer, make sure it is on). When the sauna heater is on, turn up and
down the thermostat and determine at which number the thermostat engages the
system (you will hear a click or clunk sound).
Wait 10 minutes and check which number on the thermostat engages the system.
If the number increases as the room get warmer your thermostat is working
properly.
IF THE THERMOSTAT DOES NOT ENGAGE THE SAUNA SYSTEM:
-
Check all seven parameters on page one of this guide.
-
Check wires to make sure all connections to the thermostat, timer and contactors are snug.
– If not – tighten all connections
– If yes – go back to the first page of the guide and check step #3 -
Make sure the thermostat copper capillary wires are not crimped or bent.
– If crimped – the thermostat must be replaced
– If not crimped – go back to the first page of the guide and check step #4
CONFIRMING A FAULTY THERMOSTAT
Turn the sauna off and shut off all power connections, then bypass the
thermostat by connecting the two thermostat lead wires from the controls
together. Once done, restore power and turn on the timer. If the heater system
turns on, this confirms your thermostat is faulty.
This is to be done for testing purposes only and by a licensed electrician.
TIMER SECTION
Please check all seven parameters on page one of this guide before proceeding
to this section.
The Scandia Ultra Sauna heater comes with two types of timers, a 60-minute
timer, and a 24-hour timer. The timer works in partnership with the
thermostat. In order to operate the sauna heater, both the timer and
thermostat must be turned on in order to activate the heater. When on the
timer only allows the heater to be controlled by the thermostat. In other
words, the timer will not turn on the heater unless the thermostat is turned
up. Inversely, the thermostat cannot turn on the sauna without the timer being
turned on. If the timer and the thermostat are turned on and the sauna does
not turn on, this does not mean that your timer is faulty.
TIMER INTEGRITY CHECK
To check timer functionality: reset high-limit (only if tripped) and turn on
the sauna thermostat to the #10 setting. (if equipped with a 24-hour timer,
make sure it is off). Next, turn on the timer to see if it engages the system
(you will hear a click or clunk sound).
IF THE TIMER DOES NOT ENGAGE THE SAUNA SYSTEM:
-
Check all seven parameters on page one of this guide.
-
Check wires to make sure all connections to the thermostat, timer, and contactors are snug.
– If not – tighten all connections
– If yes – go back to the first page of the guide and check step #3 -
Make sure the thermostat copper capillary wires are not crimped or bent.
– If crimped – the thermostat must be replaced
– If not crimped – go back to the first page of the guide and check step #4
CONFIRMING A FAULTY TIMER
Turn the sauna off and shut off all power connections, then bypass the timer
by connecting the two-timer lead wires from the controls together. Once done,
restore power and turn on the thermostat. If the heater system turns on, this
confirms your timer is faulty. This is to be done for testing purposes only and
by a licensed electrician.
TEMPERATURE ADJUSTMENT SECTION
This section is for troubleshooting a heater that does not reach temperature.
The thermostat is the only switch that controls the temperature of your sauna
heater.
The thermostat only works when the timer is on. The thermostat will be
disabled and the heater will not turn on if the high-limit switch has been
tripped (see high-limit section). If the high-limit switch is turning and
shutting down your heater, this means your thermostat is not controlling the
temperature as it should – or – the high-limit switch is turning off your
heater prematurely (before the thermostat turns it off).
Note: It is very important to continuously monitor the room’s temperature progression during these steps.
-
First Cycle: turn the sauna timer on and turn the thermostat to 10 settings. (If the heater does not turn on, the high limit will need to be re-set).
-
Cool Down: With the heater still on, wait until the heater unit turns off notating time elapses (from the start), and the temperature at which the unit shut down.
-
Second Cycle: wait until the heater restarts (normally 10 – 15 minutes).
Notate time elapses (from when the heater turned off) and the temperature at which the unit restarted.
Note: if the heater unit did not restart, press the high-limit button and then consult the high-limit section of this guide. -
Contact Scandia Manufacturing Technical Service Department with the following data.
CYCLES | TEMPERATURE | TIME-LAPSE |
---|---|---|
FIRST CYCLE | ||
COOLDOWN | ||
SECOND CYCLE |
1•877467•2862