Marley 5200-11257-001 Recessed Trim Kit Instruction Manual
- June 30, 2024
- MARLEY
Table of Contents
Recessed Trim Kit Accessory for RP/RS IR Heaters
FINISH OPTIONS:
STAINLESS STEEL
WHITE
BRONZE
CUSTOM
Installation Instructions
IMPORTANT INSTRUCTIONS
Tools Recommended:
Power Drill
Bit Set: Phillips
6-inch Ext. Magnetic Bit Holder
Phillips (#2) Screwdriver
SAE Socket Wrench Set
7/16″ Socket
Tape Measure
Drill Bit Set
Pencil
1-1/8″ Hole Saw
Hardware Included: Bracket Kit
(1) L-bracket x 2
(2) U-bracket x 2
(3) Screw #8-18 x 3/8 x 8
(4) Washer-Lock 1/4 Zinc Ptd x4
(5) Screw 1/4-20 x 1.50 Hex Head Zinc Ptd x4
(6) SS #8 Round Head Screw x 1-in x11
(6B) Bronze Painted Head of (6) x11
(6W) White Painted Head of (6) x11
(6U) Custom Painted Head of (6) x11
Flexible Conduit Kit
(7) Flex Connector 1/2-in Straight x 1
(8) Flex Conduit-Length size differs w/ kit x 1
(9) Esh Elbow 1/2-in Flex Conduit x 1
Trim
(10) Trim ring width side x 2 Widths and Lengths
(11) Trim ring length side x 2 Vary by Kit
SAVE THESE INSTRUCTIONS
ECO-11574 5200-11257-001
WARNING
WHEN USING ELECTRICAL APPLIANCES, BASIC PRECAUTIONS SHOULD ALWAYS BE
FOLLOWED TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, AND INJURY TO PERSONS.
TO REDUCE THE RISK OF FIRE AND ELECTRIC SHOCK OR INJURY TO PERSONS, OBSERVE
THE FOLLOWING:
PRECAUTIONS:
1. Read all instructions before installing the trim kit or using the heater.
2. Do not install heaters near sprinkler heads.
3. It is the installer’s responsibility to make sure the heater and
recess frame are mounted securely.
4. Before IR heaters can be installed, the ceiling boxes must be made and
mounting brackets must be attached. See Figures 1 and 2.
If you have a problem or need help
DO NOT RETURN
This unit to place of purchase. Let us help.
For warranty, technical assistance and service parts please call:
1-800-642-4328
Visit our website www.marleymep.com
5. For wiring and element bulb information, please refer to main infrared
heater instruction manual.
6. Prepare ceiling cut out and ceiling box. Ceiling box internal dimensions
must be as shown in table.
Conduit can be routed out the top, or side through the C-bracket holes (Ø1.12)
See Figure 2 for side hole locations.
(“A” = Length, “B” = Width)
2 Bulb Enclosure Dimensions
Enclosure Length| “A” | “B”
24in| 27.5″| 20.75″
33in| 36.5″| 20.75″
46in| 49.5″| 20.75″
3 Bulb Enclosure Dimensions
Enclosure Length| “A” | “B”
24in| 27.5″| 20.75″
33in| 36.5″| 20.75″
46in| 49.5″| 20.75″
Figure 1
7. Install recessed C-brackets centered within ceiling box and flush with the ceiling as pictured. See mounting options below. (Hardware not provided). See Figure 2.
“C” Dimension
Enclosure Style| Length
2 Bulb| 10-3/8″
3 Bulb| 13-3/4″
C-Bracket Mounting Options
A. 3 vertical holes (Ø0.50″) on top flange
B. 4 horizontal holes (Ø0.27″) on side
– Optional conduit holes (Ø1.12″) for side routing
Figure 2
8. Install conduit before heater is mounted to the ceiling. Otherwise, the installer will not be able to attach the conduit to the heater once it is in the ceiling. If using conduit holes in the C-bracket, drill holes in wood box in line with C-bracket holes. Use C-brackets to mark holes. C-brackets may need to be removed for drilling. Reinstall brackets after and install conduit.
9. Prepare heater for installation by removing the screws used for the pre- installed mounting bracket. Once removed use these same screws to attach provided “L” bracket as pictured in Figure 3.
Figure 3
10. Install heater: (2-person task), during lifting, rest the L-bracket nearest the conduit side in the respective C-bracket first. Then rest the other L-bracket in its respective C-bracket. Secure with provided screws and lock washers. See Fig’s 4a, & 4b.
Figure 4a
Viewing from above
Figure 4b
Viewing from below
- 1/4-20 x 1.5 Hex Head Screw (4) & Lock Washer (4)
11. On a flat level surface, begin assembly of trim ring by fastening the 4
pieces together with the provided hardware as pictured below. See Figure 5.
For best results, start with the hole-to-hole alignment first; then the hole-
to-slot.
A large table and a second person are recommended.
Figure 5
- (3) Screw #8-18 x 3/8 x8
12. Lastly install trim ring flush with the ceiling using supplied hardware, after which, the installation is complete.
Figure 6
- Be sure to center the trim ring about the heater for best appearance. See Figure 6. # 8 Round Head Screw x 1-in, may require pre-drill 5/64″ pilot hole.
IR Recessed Service Kits Table
Trim Kits| Width P/N
Length| Finish| 2-Element| 3-Element
24in| Stainless| RS220TK-0| RS320TK-0
White| RP221TK-W| RP321TK-W
Bronze| RP222TK-S| RP322TK-S
Custom| RP223TK-U| RP323TK-U
33in| Stainless| RS230TK-0| RS330TK-0
White| RP231TK-W| RP331TK-W
Bronze| RP232TK-S| RP332TK-S
Custom| RP233TK-U| RP333TK-U
46in| Stainless| RS240TK-0| RS340TK-0
White| RP241TK-W| RP341TK-W
Bronze| RP242TK-S| RP342TK-S
Custom| RP243TK-U| RP343TK-U
Hardware Kits
IRK-RBKTHDWR | IRR Bracket & Hardware
IRK-RCOND24 | IRR Flex Conduit 24in
IRK-RCOND33| IRR Flex Conduit 33in
IRK-RCOND46| IRR Flex Conduit 46in
IRR-INST-BRK-KT| IRR Bracket Installation
IRR-PNS-SERV-KITS.XLSX
LIMITED WARRANTY
All products manufactured by Marley Engineered Products are warranted against defects in workmanship and materials for one year from date of purchase. This warranty does not apply to damage from accident, misuse, or alteration; nor where the connected voltage is more than 5% above the nameplate voltage; nor to equipment improperly installed or wired or maintained in violation of the product’s installation instructions. This warranty does not apply to refurbished products. All claims for warranty work must be accompanied by proof of the date of purchase.
The customer shall be responsible for all costs incurred in the removal or reinstallation of products, including labor costs, and shipping costs incurred to return products to Marley Engineered Products. Within the limitations of this warranty, inoperative units should be returned to Marley Engineered Products, and we will repair or replace, at our option, at no charge to you with return freight paid by Marley. It is agreed that such repair or replacement is the exclusive remedy available from Marley Engineered Products.
THE ABOVE WARRANTIES ARE IN LIEU OF ALL OTHER WARRANTIES EXPRESSED OR IMPLIED, AND ALL IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE WHICH EXCEED THE AFORESAID EXPRESSED WARRANTIES ARE HEREBY DISCLAIMED AND EXCLUDED FROM THIS AGREEMENT. MARLEY ENGINEERED PRODUCTS SHALL NOT BE LIABLE FOR CONSEQUENTIAL DAMAGES ARISING WITH RESPECT TO THE PRODUCT, WHETHER BASED UPON NEGLIGENCE, TORT, STRICT LIABILITY, OR CONTRACT.
Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above exclusion or limitation may not apply to you. This warranty gives you specific legal rights, and you may also have other rights which vary from state to state.
Contact Marley Engineered Products in Bennettsville, SC, at 1-800-642-4328. Merchandise returned to the factory must be accompanied by a return authorization and service identification tag, both available from Marley Engineered Products. When requesting return authorization, include all catalog numbers shown on the products.
HOW TO OBTAIN WARRANTY SERVICE AND WARRANTY PARTS PLUS GENERAL INFORMATION
- Warranty Service or Parts 1-800-642-4328
- Purchase Replacement Parts 1-800-654-3545
- General Product Information www.marleymep.com
Note: When obtaining service always have the following:
- Model number of the product
- Date of manufacture
- Part number or description
470 Beauty Spot Rd. East
Bennettsville, SC 29512 USA
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>