Aeotec ZWA046-C Home Energy Meter User Guide
- June 30, 2024
- Aeotec
Table of Contents
Aeotec ZWA046-C Home Energy Meter
Specifications
Structural
- Product Identifier: AEOTEC Home Energy Meter 8
- Dimensions: Not specified
- Weight: Not specified
- Color: Blue
- Usage: Measure Watt (W or kVar), KWH or kVarh, Voltage, and Current Input power
- Operating Temperature: Not specified
- Relative Humidity: Not specified
Hardware
- Z-Wave Module: EFR32ZG23
- Z-Wave TX Power: Max 20dBm
- Z-Wave Antenna Distance: 40m (Indoor) / 150m (Outdoor)
- Indicator Light Color: Blue
- Buttons: Action Button x 1
- Input Voltage: 230V~50Hz
- Working Current: 30mA
- Standby Current: 5mA
- Maximum Standby Power Consumption: 1.1W
Software
- Wireless Technology: Z-Wave
- Certification Type: Not specified
- Z-Wave SDK Version: Not specified
- Z-Wave Library Type: Not specified
- Z-Wave Role Type: Not specified
- Generic Product Type: Not specified
- Specific Product Type: Not specified
- Security Class: Not specified
- SmartStart Compatible: Yes
- Over The Air (OTA): Not specified
- Multi Channel Product Association: Not specified
- Factory Reset: Yes
- Power-down Memory Meter State Report Control other product: Not specified
Home Energy Meter 8
REVISION RECORD
Version
1.0
| Date
2024.04.24
| Brief
First
| description
revision.
| of| changes
OVERVIEW
Aeotec Home Energy Meter 8 is a energy meter for the entire home. It can
wirelessly report instantaneous Power, KWH, Voltage and Amperage measurements
to Z-Wave ® gateway/controller. It can send Z-Wave REPORTS at any time when it
receives Z-Wave Get Commands.
The HEM can be setup to send automatic reports to any associated nodes in
association group 1 at an interval time. It can be included and operated in
any Z-Wave network with other Z-Wave/ Z-Wave Plus® certified devices from
other manufacturers and/or other applications. All non-battery operated nodes
within the network will act as repeaters regardless of vendor to increase
reliability of the network. The device supports the Z Wave Security S2
framework with authenticated and unauthenticated network keys. Please follow
the instructions on the central controller when including. The device also
supports SmartStart. It also supports the Over The Air (OTA) feature for the
product’s firmware upgrade. As soon as the HEM is removed from a Z-Wave
network it will be reset to default factory settings.
Terminology | Description |
---|---|
Action Button | Used for networking ,resetting and protecte the device. |
Led (blue) | Used for indicating the current state of the product. |
Clamps | get the measurement of Watt (W or kVar), KWH or kVarh, Voltage and |
Current
AC Input Wire| Input power
SPECIFICATIONS
Structural
Parameter | Value |
---|---|
Product Identifier | ZW046 |
Dimensions | 2 8x95x35mm |
Weight | 2 0g |
Color | White |
Usage | For indoor use. |
Operating Temperature | 32~104°F (0~40°C) |
Relative Humidity | 8%~80% |
Hardware
Parameter | Value |
---|---|
Z-Wave Module | EFR32ZG23 |
Z-Wave TX Power | Max: 20dBm |
Z-Wave Antenna Distance | 40m (Indoor) /150m (Outdoor) |
Indicator Light Color | blue |
Buttons | Action Button x 1 |
Input Voltage | 230V~50Hz |
Working Current | 30mA |
Standby Current | 5mA |
Maximum Standby Power Consumption | 1.1W |
Software
Parameter | Value |
---|---|
Wireless Technology | Z-Wave |
Certification Type | Z-Wave Plus v2 Certification |
Z-Wave SDK Version | 7.20.2 |
Z-Wave Library Type | Enhanced 232 Slave |
Z-Wave Role Type | Always On Slave [0x05] |
Generic Product Type | GENERIC_TYPE_METER [0x31] |
Specific Product Type | SPECIFIC_TYPE_NOT_USED [0x00] |
Security Class | Non-Security, S0, S2 Unauthenticated, and S2 Authenticated |
SmartStart Compatible | Support. After powering on, SmartStart is auto |
activated.
Over The Air (OTA)| Support. Firmware can be updated via RF.
Multi Channel Product| Yes
Association| Support. Refer to Section 4.8 Association Group Info.
Factory Reset| Support. Refer to Section 3.8 How to factory reset.
Power-down Memory| Support. All command settings will stay unchanged even
power down.
Meter State Report| Support. Send out meter report via Group 1.
Control other product| No
QUICK START
Important safety information
Please read this manual carefully. Failure to follow the recommendations in
this manual may be dangerous or may violate the law. The manufacturer,
importer, distributor and seller shall not be liable for any loss or damage
resulting from failure to comply with the instructions in this manual or any
other material. Use this equipment only for its intended purpose. Follow the
disposal instructions. Do not dispose of electronic equipment in a fire or
near open heat sources.
Optimally fixing the main body
It is now time to fix HEM’s main body onto a surface. Within each meter, there
is a low-frequency radio antenna for wireless communication. As such, thick
concrete walls, metals, or motor devices can negatively impact the wireless
performance of HEM and should be avoided. It is recommended to have the main
body installed outside of the circuit box if the home’s circuit box is made of
a metal, since placing the meter inside a metal circuit box could degrade the
quality of the radio signal and negatively impact its wireless range. As such,
HEM’s main body is weatherised to the IP44 standard making it resistant to
rain and snow when installed vertically.
How to install the product
How to add the product
The following will step you through adding the product to your Z-Wave network.
-
Fix Back-Mount Plate to the selected position with the provided screws. The plate should be installed vertically to make sure the connected cables naturally hanging and to fully ensure that the IP44 weatherized rating applies.
-
Set your Z-Wave gateway into its ‘add device’ mode in order to connect Home Energy Meter to your Z-Wave system. Refer to the gateway’s manual if you are unsure of how to perform this step.
-
Press Action Button on the back of main body; its LED will flash blue rapidly to indicate it has entered pair mode.
When Home Energy Meter successfully joins your Z-Wave network its LED will flash blue for several seconds and then turn solid blue. Should the LED keep blinking blue, it has been unable to join your Z-Wave network; repeat the above steps and please contact us for further support if needed. -
Attach the main body to the Back-Mount Plate.
If your Z-Wave gateway supports SmartStart: scan the QR code on Home Energy Meter using the gateway’s app. Your sensor will join your Z-Wave network automatically.
How to remove the product
- Set your Z-Wave gateway into its ‘remove device’ mode.
- Press Action Button on the back of main body; its LED will flash blue rapidly to indicate it has entered remove mode.
- When Home Energy Meter successfully remove, its LED will flash blue.
About SmartStart
SmartStart-enabled products can be added into a Z-Wave network by scanning the
Z-Wave QR Code present on the product with a controller providing SmartStart
inclusion. No further action is required and the SmartStart product will be
added automatically within 10 minutes of being switched on in the network
vicinity. You can find the QR code on the back of the product, like this:
The DSK information will be like this: 05065-41336-16018-47313-50335-02212-29424-38760
About Product
This product can be operated in any Z-Wave network with other Z-Wave-certified
devices from other manufacturers. All mains-operated nodes within the network
will act as repeaters regardless of vendor to increase reliability of the
network.
How to factory reset
This device also allows to be reset without any involvement of a Z-Wave
controller. This procedure should only be used when the primary controller is
inoperable.
Make sure the product is powered. To complete the reset process manually,
press and hold the Action Button for at least 10s. The Indicator Light will
become flash, which indicates the reset operation is successful. Otherwise,
please try again. Contact us for further support if needed.
SOFTWARE FUNCTION DEFINITION
User Behavior Interaction
Supported Command Classes
Root device
Command Class | Version | Not added | Non-secure added | Securely added |
---|---|---|---|---|
Non-secure | Secure S0/S2 | |||
ZWAVEPLUS_INFO | 2 | Support | Support | Support |
METER | 6 | Support | Support | |
MULTI_CHANNEL | 4 | Support | Support | |
CONFIGURATION | 4 | Support | Support | |
APPLICATION_STATUS | 1 | Support | Support | Support |
ASSOCIATION | 2 | Support | Support | |
MULTI_CHANNEL_ASSOCIATION | 3 | Support | Support | |
ASSOCIATION_GRP_INFO | 3 | Support | Support | |
TRANSPORT_SERVICE | 2 | Support | Support | Support |
VERSION | 3 | Support | Support | |
MANUFACTURER_SPECIFIC | 2 | Support | Support | |
DEVICE_RESET_LOCALLY | 1 | Support | Support | |
INDICATOR | 3 | Support | Support | |
POWERLEVEL | 1 | Support | Support | |
SECURITY | 1 | Support | Support | Support |
SECURITY_2 | 1 | Support | Support | Support |
SUPERVISION | 1 | Support | Support | Support |
FIRMWARE_UPDATE_MD | 5 | Support | Support | |
Command Class | Version | Not added | Non-secure added | Securely added |
--- | --- | --- | --- | --- |
Non-secure | Secure | |||
ZWAVEPLUS_INFO | 2 | Support | Support | Support |
METER | 6 | Support | Support | |
ASSOCIATION | 2 | Support | Support | |
MULTI_CHANNEL_ASSOCIATION | 3 | Support | Support | |
ASSOCIATION_GRP_INFO | 3 | Support | Support | |
SECURITY | 1 | Support | Support | Support |
SECURITY_2 | 1 | Support | Support | Support |
SUPERVISION | 1 | Support | Support | Support |
Multi Channel CC And Meter CC
The Multi Channel Command supports 8 end points, which corresponding to Phase
A/B/C. Endpoint 1= Phase A Import
The Multi Channel Command supports 8 end points, which corresponding to Phase A/B/C.
- Endpoint 1= Phase A Import
- Endpoint 2= Phase A Export
- Endpoint 3= Phase B Import
- Endpoint 4= Phase B Export
- Endpoint 5= Phase C Import
- Endpoint 6= Phase C Export
- Endpoint 7= algebraic sum of import current of all phases
- Endpoint 8= algebraic sum of export current of all phases
The Multi Channel CC encapsulates Meter Command Class, which can get the measurement of Watt (W or kVar), KWH or kVarh, Voltage and Current , kVah and factor from the Phases.
Meter | Function |
---|---|
Scale | Root device |
1
| Enpoint
2
| Enpoint
3
| Enpoint
4
| Enpoint
5
| Enpoint
6
| Enpoint
7
| Enpoint
8
V| 1.Average voltage of all phases are normal| Voltage of phase A| Voltage of
phase A| Voltage of phase B| Voltage of phase B| Voltage of phase C| Voltage
of phase C| Same as the root device| Same as the root device
| 2.Abnormal voltage when any phase is abnormal| | | | | | | |
| (Less than 90V or greater than 440V)| | | | | | | |
A| Import type:
algebraic sum of import current of all phases
Export type:
| Import current of phase A| export current of phase A| Import current of phase B| export current of phase B| Import current of phase C| export current of phase C| algebraic sum of import current of all
phases
| algebraic sum of export current of all
phases
| algebraic sum of export current of all phases| | | | | | | |
W| Import type:| Import power| export power| Import power| export power|
Import power| export power| algebraic sum of| algebraic sum of
| algebraic sum of import power of all phases
Export type:
| of phase A| of phase A| of phase B| of phase B| of phase C| of phase C|
import power of all phases| export power of all phases
---|---|---|---|---|---|---|---|---|---
algebraic sum of export power of all phases| | | | | | | |
KWh| Import type:
algebraic sum of import energy of all phases
Export type:
| Import energy of phase A| export energy of phase A| Import energy of phase B| export energy of phase B| Import energy of phase C| export energy of phase C| algebraic sum of import energy of all
phases
| algebraic sum of export energy of all
phases
| algebraic sum of export energy of all phases| | | | | | | |
KVar| Import type:
algebraic sum of import Kvar of all phases
Export type:
| import kVar of phase A| export kVar of phase A| import kVar of phase B|
export kVar of phase B| import kVar of phase C| export kVar of phase C|
algebraic sum of import Kvar of all phases| algebraic sum of
export Kvar of all phases
| algebraic sum of export Kvar of all phases| | | | | | | |
KVarh| Import type:
algebraic sum of import Kvarh of all phases
Export type:
algebraic sum of export Kvarh of all phases
| import Kvarh of phase A| export Kvarh of phase A| import Kvarh of phase B| export Kvarh of phase B| import Kvarh of phase C| export Kvarh of phase C| algebraic sum of import Kvarh of all phases|
algebraic sum of export Kvarh of all phases
kVAh| Import type:
algebraic sum of import kVAh of all phases
Export type:
| import kVah of phase A| export kVah of phase A| import kVah of phase B|
export kVah of phase B| import kVah of phase C| export kVah of phase C|
algebraic sum of import kVAh of all phases| algebraic sum of export
kVAh of all phases
| algebraic sum of export kVAh of all phases| | | | | | | |
Power Factor| Import type:| import factor of| export factor of| import factor|
export factor| import factor| export factor| Import Power /| Export Power /
| Import Power / (Import Current * Voltage)
Export type:
| phase A| phase A| of phase B| of phase B| of phase C| of phase C| (Import Current
- Voltage)
| (Export Current
- Voltage)
---|---|---|---|---|---|---|---|---|---
Export Power / (Export Current * Voltage)| | | | | | | |
Basic Command Class mapping
Basic Command Class is not mapped to any of the supported command classes.
Z-Wave Plus Info
Parameter | Value |
---|---|
Z-Wave Plus Version | 0x02 |
Role Type | 0x05 (ZWAVEPLUS_INFO_REPORT_ROLE_TYPE_SLAVE_ALWAYS_ON) |
Node Type | 0x00 [ZWAVEPLUS_INFO_REPORT_NODE_TYPE_ZWAVEPLUS_NODE) |
Installer Icon Type | 0x1000 (ICON_TYPE_GENERIC_SUB_ENERGY_METER) |
User Icon Type | 0x1000 (ICON_TYPE_GENERIC_SUB_ENERGY_METER) |
Manufacturer Specific
Parameter | Value |
---|---|
Manufacturer ID 1 | 0x03 |
Manufacturer ID 2 | 0x71 |
Product Type ID 1 | 0x00 [EU], 0x01 [US], 0x02 [AU]] |
Product Type ID 2 | 0x03 [Power/Energy Controller] |
Product ID 1 | 0x00 |
Product ID 2 | 0x2E (46) |
Version
Parameter | Value |
---|---|
Z-Wave Protocol Library Type | 0x03 |
Z-Wave Protocol Version | 0x07 |
Z-Wave Protocol Sub Version | 0x14 |
Firmware 0 Version | 0x01 [Z-Wave Chip Firmware Version] |
Firmware 0 Sub Version | 0x00 [Z-Wave Chip Firmware Sub Version] |
Hardware Version | 0x2E (46) |
Number of firmware targets | 0x00 |
Association Group Info
Root ID | Name | Node count | Profile | Function |
---|
1
| ****
Lifeline
| ****
5
| ****
General: Lifeline (0x0001)
|
-
Product Reset Locally Notification:
Issued when Factory Reset is performed. -
Meter Report:
Root device / Endpoint Meter Report
Mark: Node does not support sending indicator reports through associated
groups.
Endpoint1:
ID | Name | Node count | Profile | Function |
---|---|---|---|---|
1 | Phase A consumption via Lifeline |
0
| Meter:Electric (0x3201)|
- when the power exceeds the threshold or percentage (configured via parameter 5/13)
- when time report group performed (configured via parameter 101/102/103) Issued the Meter Report via the Root device Lifeline group
Endpoint2
ID | Name | Node count | Profile | Function |
---|---|---|---|---|
1 | Phase A production via Lifeline | 0 | Meter:Electric (0x3201) |
- when the power exceeds the threshold or percentage (configured via parameter 9/17)
- when time report group performed (configured via parameter 104/105/106) Issued the Meter Report via the Root device Lifeline group
Endpoint3
ID | Name | Node count | Profile | Function |
---|---|---|---|---|
1 | Phase B consumption via Lifeline | 0 | Meter:Electric (0x3201) |
- when the power exceeds the threshold or percentage (configured via parameter 6/14)
- when time report group performed (configured via parameter 101/102/103)Issued the Meter Report via the Root device Lifeline group
Endpoint4:
ID | Name | Node count | Profile | Function |
---|---|---|---|---|
1 | Phase B production via Lifeline | 0 | Meter:Electric (0x3201) |
- when the power exceeds the threshold or percentage (configured via parameter 10/18)
- when time report group performed (configured via parameter 104/105/106)Issued the Meter Report via the Root device Lifeline group
Endpoint5:
ID | Name | Node count | Profile | Function |
---|---|---|---|---|
1 | Phase C consumption via Lifeline | 0 | Meter:Electric (0x3201) |
- when the power exceeds the threshold or percentage (configured via parameter 7/15)
- when time report group performed (configured via parameter 101/102/103)Issued the Meter Report via the Root device Lifeline group
Endpoint6:
ID | Name | Node count | Profile | Function |
---|---|---|---|---|
1 | Phase C production via Lifeline |
0
| Meter:Electric (0x3201)|
- when the power exceeds the threshold or percentage (configured via parameter 11/19)
- when time report group performed (configured via parameter 104/105/106) Issued the Meter Report via the Root device Lifeline
| | | | group
---|---|---|---|---
Endpoint7
ID | Name | Node count | Profile | Function |
---|---|---|---|---|
1 | Total consumption via Lifeline | 0 | Meter:Electric (0x3201) |
- when the power exceeds the threshold or percentage (configured via parameter 4/12)
- when time report group performed (configured via parameter 101/102/103) Issued the Meter Report via the Root device Lifeline group
Endpoint8
ID | Name | Node count | Profile | Function |
---|---|---|---|---|
1 | Total production via Lifeline | 0 | Meter:Electric (0x3201) |
- when the power exceeds the threshold or percentage (configured via parameter 8/16)
- when time report group performed (configured via parameter 104/105/106)
- Issued the Meter Report via the Root device Lifeline group
Indicator
Indicator ID | Property ID |
---|---|
Node Identify (blue Led) | 0x50 |
On Off Cycles | 0x04 |
On time within an On/Off period | 0x05 |
Meter CC
- Report consumed voltage:A1 64 ……
- Report produced voltage:C1 64 ……
- Report consumed current: A1 6C ……
- Report produced current: C1 6C ……
- Report consumed power:21 74 ……
- Report produced power: 41 74 ……
- Report consumed energy:21 64 ……
- Report produced energy: 41 64 ……
- Report consumed kvar:A1 7C ……00
- Report produced kvar: C1 7C ……00
- Report consumed kvarh:A1 7C ……01
- Report produced kvarh: C1 7C ……01
- Report consumed kVAh:21 6C ……
- Report produced kVAh: 41 6C ……
- Report consumed factor:A1 74 ……
- Report produced factor: C1 74 ……
Mark:
Meter Type: Electric meter
Rate Type: Root device supports Import and Export, Endpoint 1/3/5/7 supports
Import, Endpoint 2/4/6/8 supports Import.
Scale: kWh, kVAh, W, V, A, Factor, kVar, kVarh
Configuration
Parameter | 0x03 (3) |
---|---|
Name | Threshold Check Enable/Disable |
Info | Enable/Disable threshold reporting |
Properties | Size |
Format | Enumerated |
Read-only | False |
Altering capabilities | False |
Description | Enable selective reporting only when power change reaches a |
certain threshold or percentage set in 4-19 below. This is used to reduce
network traffic.
Value| Function
0| Disable
1| Enable
Parameter| 0x04 (4)
---|---
Name| Import watt threshold (Total)
Info| Import watt threshold (Total)
Properties| Size| 2| Min Value| 5
Format| Unsigned Integer| Max Value| 60000
Read-only| False| Default Value| 50
Altering capabilities| False| Advanced| False
Description| Threshold change in import wattage to induce an automatic report
(Whole HEM).
Value| Function
0-60000| W
Parameter| 0x05 (5)
---|---
Name| Import watt threshold (Phase A)
Info| Import watt threshold (Phase A)
Properties| Size| 2| Min Value| 5
Format| Unsigned Integer| Max Value| 60000
Read-only| False| Default Value| 50
Altering capabilities| False| Advanced| False
Description| Threshold change in import wattage to induce an automatic report
(Phase A).
Value| Function
0-60000| W
Parameter 0x06 (6)
Name | Import watt threshold (Phase B) |
---|---|
Info | Import watt threshold (Phase B) |
Properties | Size |
Format | Unsigned Integer |
Read-only | False |
Altering capabilities | False |
Description | Threshold change in import wattage to induce an automatic report |
(Phase B).
Value| Function
0-60000| W
Parameter| 0x07 (7)
---|---
Name| Import watt threshold (Phase C)
Info| Import watt threshold (Phase C)
Properties| Size| 2| Min Value| 5
Format| Unsigned Integer| Max Value| 60000
Read-only| False| Default Value| 50
Altering capabilities| False| Advanced| False
Description| Threshold change in import wattage to induce an automatic report
(Phase C).
Value| Function
0-60000| W
Parameter| 0x08 (8)
---|---
Name| Export watt threshold(Total)
Info| Export watt threshold(Total)
Properties| Size| 2| Min Value| 5
Format| Unsigned Integer| Max Value| 60000
Read-only| False| Default Value| 50
Altering capabilities| False| Advanced| False
Description| Threshold change in export wattage to induce an automatic report
(Whole HEM).
Value| Function
0-60000| W
Parameter| 0x09 (9)
---|---
Name| Export watt threshold (Phase A)
Info| Export watt threshold (Phase A)
Properties| Size| 2| Min Value| 5
Format| Unsigned Integer| Max Value| 60000
Read-only| False| Default Value| 50
Altering capabilities| False| Advanced| False
Description| Threshold change in export wattage to induce an automatic report
(Phase A).
Value| Function
0-60000| W
Parameter 0x0A (10)
Name | Export watt threshold (Phase B) |
---|---|
Info | Export watt threshold (Phase B) |
Properties | Size |
Format | Unsigned Integer |
Read-only | False |
Altering capabilities | False |
Description | Threshold change in export wattage to induce an automatic report |
(Phase B).
Value| Function
0-60000| W
Parameter| 0x0B (11)
---|---
Name| Export watt threshold (Phase C)
Info| Export watt threshold (Phase C)
Properties| Size| 2| Min Value| 5
Format| Unsigned Integer| Max Value| 60000
Read-only| False| Default Value| 50
Altering capabilities| False| Advanced| False
Description| Threshold change in export wattage to induce an automatic report
(Phase C).
Value| Function
0-60000| W
Parameter| 0x0C(12)
---|---
Name| Import watt percent threshold (Total)
Info| Import watt percent threshold (Total)
Properties| Size| 1| Min Value| 1
Format| Unsigned Integer| Max Value| 100
Read-only| False| Default Value| 20
Altering capabilities| False| Advanced| False
Description| Percentage change in import wattage to induce an automatic report
(Whole HEM).
Value| Function
0-100| Unit: %
Parameter| 0x0D(13)
---|---
Name| Import watt percent threshold (Phase A)
Info| Import watt percent threshold (Phase A)
Properties| Size| 1| Min Value| 1
Format| Unsigned Integer| Max Value| 100
Read-only| False| Default Value| 20
Altering capabilities| False| Advanced| False
Description| Percentage change in import wattage to induce an automatic report
(Phase A).
Value| Function
0-100| Unit: %
Parameter 0x0E(14)
Name | Import watt percent threshold (Phase B) |
---|---|
Info | Import watt percent threshold (Phase B) |
Properties | Size |
Format | Unsigned Integer |
Read-only | False |
Altering capabilities | False |
Description | Percentage change in import wattage to induce an automatic report |
(Phase B).
Value| Function
0-100| Unit: %
Parameter| 0x0F(15)
---|---
Name| Import watt percent threshold (Phase C)
Info| Import watt percent threshold (Phase C)
Properties| Size| 1| Min Value| 1
Format| Unsigned Integer| Max Value| 100
Read-only| False| Default Value| 20
Altering capabilities| False| Advanced| False
Description| Percentage change in import wattage to induce an automatic report
(Phase C).
Value| Function
0-100| Unit: %
Parameter| 0x10(16)
---|---
Name| Export watt percent threshold (Total)
Info| Export watt percent threshold (Total)
Properties| Size| 1| Min Value| 1
Format| Unsigned Integer| Max Value| 100
Read-only| False| Default Value| 20
Altering capabilities| False| Advanced| False
Description| Percentage change in export wattage to induce an automatic report
(Whole HEM).
Value| Function
0-100| Unit: %
Parameter| 0x11(17)
---|---
Name| Export watt percent threshold (Phase A)
Info| Export watt percent threshold (Phase A)
Properties| Size| 1| Min Value| 1
Format| Unsigned Integer| Max Value| 100
Read-only| False| Default Value| 20
Altering capabilities| False| Advanced| False
Description| Percentage change in export wattage to induce an automatic report
(Phase A).
Value| Function
0-100| Unit: %
Parameter 0x12(18)
Name | Export watt percent threshold (Phase B) |
---|---|
Info | Export watt percent threshold (Phase B) |
Properties | Size |
Format | Unsigned Integer |
Read-only | False |
Altering capabilities | False |
Description | Percentage change in export wattage to induce an automatic report |
(Phase B).
Value| Function
0-100| Unit: %
Parameter| 0x13(19)
---|---
Name| Export watt percent threshold (Phase C)
Info| Export watt percent threshold (Phase C)
Properties| Size| 1| Min Value| 1
Format| Unsigned Integer| Max Value| 100
Read-only| False| Default Value| 20
Altering capabilities| False| Advanced| False
Description| Percentage change in export wattage to induce an automatic report
(Phase C).
Value| Function
0-100| Unit: %
Parameter| 0x64 (100)
---|---
Name| Set 101-106 to default
Info| Set 101-106 to default
Properties| Size| 1| Min Value| 0
Format| Enumerated| Max Value| 1
Read-only| False| Default Value| 0
Altering capabilities| False| Advanced| False
Description| Set 101-106 to default.
Parameter| 0x65 (101)
---|---
Name| Automatic Report list 1 (Import)
Info| Checklist 1 for automatic timed report
Properties| Size| 4| Min Value| 0
Format| Enumerated| Max Value| 0xFFFFFFFF
Read-only| False| Default Value| 0x03030303
Altering capabilities| False| Advanced| False
Description| Configure which report needs to be sent in Report group 1 (See
flags in import table below).
Parameter| 0x66 (102)
---|---
Name| Automatic Report list 2 (Import)
Info| Checklist 2 for automatic timed report
Properties| Size| 4| Min Value| 0
Format| Enumerated| Max Value| 0xFFFFFFFF
Read-only| False| Default Value| 0x0C0C0C0C
| Altering capabilities| False| Advanced| False
---|---|---|---|---
Description| Configure which report needs to be sent in Report group 2 (See
flags in import table below).
Parameter| 0x67 (103)
---|---
Name| Automatic Report list 3 (Import)
Info| Checklist 3 for automatic timed report
Properties| Size| 4| Min Value| 0
Format| Enumerated| Max Value| 0xFFFFFFFF
Read-only| False| Default Value| 0xF0F0F0F0
Altering capabilities| False| Advanced| False
Description| Configure which report needs to be sent in Report group 3 (See
flags in import table below).
Parameter
| 0x68 (104)
---|---
Name| Automatic Report list 1 (Export)
Info| Checklist 1 for automatic timed report
Properties| Size| 4| Min Value| 0
Format| Enumerated| Max Value| 0xFFFFFFFF
Read-only| False| Default Value| 0x03030303
Altering capabilities| False| Advanced| False
Description| Configure which report needs to be sent in Report group 1 (See
flags in export table below).
Parameter| 0x69 (105)
---|---
Name| Automatic Report list 2(Export)
Info| Checklist 2 for automatic timed report
Properties| Size| 4| Min Value| 0
Format| Enumerated| Max Value| 0xFFFFFFFF
Read-only| False| Default Value| 0x0C0C0C0C
Altering capabilities| False| Advanced| False
Description| Configure which report needs to be sent in Report group 2 (See
flags in export table below).
Parameter| 0x6A (106)
---|---
Name| Automatic Report list 3 (Export)
Info| Checklist 3 for automatic timed report
Properties| Size| 4| Min Value| 0
Format| Enumerated| Max Value| 0xFFFFFFFF
Read-only| False| Default Value| 0xF0F0F0F0
Altering capabilities| False| Advanced| False
Description| Configure which report needs to be sent in Report group 3 (See
flags in export table below).
Parameter| 0x6E (110)
---|---
Name| Set 111-116 to default
Info| Set 111-116 to default
Properties| Size| 1| Min Value| 0
Format| Enumerated| Max Value| 1
| Read-only| False| Default Value| 0
---|---|---|---|---
Altering capabilities| False| Advanced| False
Description| Set 111-116 to default.
Parameter| 0x6F (111)
---|---
Name| Automatic list 1 Interval Time (Import)
Info| Timing detection time of Checklist 1
Properties| Size| 4| Min Value| 10
Format| Unsigned Integer| Max Value| 0xFFFFFFFF
Read-only| False| Default Value| 3600
Altering capabilities| False| Advanced| False
Description| Set the interval time of sending report in Report group 1
Parameter| 0x70 (112)
---|---
Name| Automatic list 2 Interval Time (Import)
Info| Timing detection time of Checklist 2
Properties| Size| 4| Min Value| 10
Format| Unsigned Integer| Max Value| 0xFFFFFFFF
Read-only| False| Default Value| 7200
Altering capabilities| False| Advanced| False
Description| Set the interval time of sending report in Report group 2
Parameter| 0x71 (113)
---|---
Name| Automatic list 3 Interval Time (Import)
Info| Timing detection time of Checklist 3
Properties| Size| 4| Min Value| 10
Format| Unsigned Integer| Max Value| 0xFFFFFFFF
Read-only| False| Default Value| 7200
Altering capabilities| False| Advanced| False
Description| Set the interval time of sending report in Report group 3
Parameter| 0x72 (114)
---|---
Name| Automatic list 1 Interval Time (Export)
Info| Timing detection time of Checklist 1
Properties| Size| 4| Min Value| 10
Format| Unsigned Integer| Max Value| 0xFFFFFFFF
Read-only| False| Default Value| 3600
Altering capabilities| False| Advanced| False
Description| Set the interval time of sending report in Report group 1
Parameter| 0x73 (115)
---|---
Name| Automatic list 2 Interval Time (Export)
Info| Timing detection time of Checklist 2
Properties| Size| 4| Min Value| 10
Format| Unsigned Integer| Max Value| 0xFFFFFFFF
| Read-only| False| Default Value| 7200
---|---|---|---|---
Altering capabilities| False| Advanced| False
Description| Set the interval time of sending report in Report group 2
Parameter| 0x74 (116)
---|---
Name| Automatic list 3 Interval Time (Export)
Info| Timing detection time of Checklist 3
Properties| Size| 4| Min Value| 10
Format| Unsigned Integer| Max Value| 0xFFFFFFFF
Read-only| False| Default Value| 7200
Altering capabilities| False| Advanced| False
Description| Set the interval time of sending report in Report group 3
Parameter| 0xFC (252)
---|---
Name| Enable/disable to lock configuration setting
Info| Enable/disable to lock configuration setting
Properties| Size| 1| Min Value| 0
Format| Unsigned Integer| Max Value| 1
Read-only| False| Default Value| 0
Altering capabilities| False| Advanced| False
Description| Enable/disable to lock configuration parameters
Value| Function
0| Disable
1| Enable.
Configuration Values for parameter 101-103:(Enpoint 1, Enpoint 3, Enpoint 5, Enpoint 7)
| 7| 6| 5| 4| 3| 2| 1| 0
---|---|---|---|---|---|---|---|---
Configuration Value 1(MSB)| import factor of phase A
(send through endpoint 1)
| import kVAh of phase A
(send through endpoint 1)
| import kVar of phase A (send through endpoint 1)| import kVarh of
phase A (send through endpoint 1)| import current of phase A (send through
endpoint 1)| import voltage of phase A (send through endpoint 1)| import watt
of phase A (send through endpoint 1)| import kwh of phase A (send through
endpoint 1)
Configuration Value 2| import factor of phase B
(send through endpoint 3)
| import kVAh of phase B
(send through endpoint 3)
| import kVar of phase B (send through endpoint 3)| import kVarh of
phase A (send through endpoint 3)| import current of phase B (send through
endpoint 3)| import voltage of phase B (send through endpoint 3)| import watt
of phase B (send through endpoint 3)| import kwh of phase B (send through
endpoint 3)
Configuration Value 3| import factor of phase C
(send through endpoint 5)
| import kVAh of phase C
(send through endpoint 5)
| import kVar of phase C (send through endpoint 5)| import kVarh of
phase C (send through endpoint 5)| import current of phase C (send through
endpoint 5)| import voltage of phase C (send through endpoint 5)| import watt
of phase C (send through endpoint 5)| import kwh of phase C (send through
endpoint 5)
Configuration| import| import kVah| import kVar| import| import| import|
import watt| import kwh
Value 4(LSB)| factor of
tatal
| of tatal
(send
| of tatal
(send
| kVarh of
tatal
| current of
tatal
| voltage of
tatal
| of tatal
(send
| of tatal
(send
---|---|---|---|---|---|---|---|---
| (send| through| through| (send| (send| (send| through| through
| through
endpoint 7)
| endpoint 7)| endpoint 7)| through
endpoint 7)
| through
endpoint 7)
| through
endpoint 7)
| endpoint 7)| endpoint 7)
Configuration Values for parameter 104-106:(Enpoint 2, Enpoint 4, Enpoint 6, Enpoint 8)
| 7| 6| 5| 4| 3| 2| 1| 0
---|---|---|---|---|---|---|---|---
Configuration Value 1(MSB)| export factor of phase A
(send through endpoint 2)
| export kVAh of phase A
(send through endpoint 2)
| export kVar of phase A (send through endpoint 2)| export kVarh of
phase A (send through endpoint 2)| export current of phase A (send through
endpoint 2)| export voltage of phase A (send through endpoint 2)| export watt
of phase A (send through endpoint 2)| export kwh of phase A (send through
endpoint 2)
Configuration Value 2| export factor of phase B
(send through endpoint 4)
| export kVAh of phase B
(send through endpoint 4)
| im export port kVar of phase B (send through endpoint 4)| export kVarh
of phase A (send through endpoint 4)| export current of phase B (send through
endpoint 4)| export voltage of phase B (send through endpoint 4)| export watt
of phase B (send through endpoint 4)| export kwh of phase B (send through
endpoint 4)
Configuration Value 3| export factor of phase C
(send through endpoint 6)
| export kVAh of phase C
(send through endpoint 6)
| export kVar of phase C (send through endpoint 6)| export kVarh of
phase C (send through endpoint 6)| export current of phase C (send through
endpoint 6)| export voltage of phase C (send through endpoint 6)| export watt
of phase C (send through endpoint 6)| export kwh of phase C (send through
endpoint 6)
Configuration Value 4(LSB)| export factor of tatal
(send through endpoint 8)
| export kVah of tatal
(send through endpoint 8)
| export kVar of tatal (send through endpoint 8)| export kVarh of tatal
(send through endpoint 8)
| export current of tatal
(send through endpoint 8)
| export voltage of tatal
(send through endpoint 8)
| export watt of tatal (send through endpoint 8)| export kwh of tatal (send through endpoint 8)
Mark:
When sending to the aggregation point, add sending to the root device.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>