Digital Differential Manometer
ET180
P1, P2, AND DIFFERENTIAL PRESSURE
+/- 60 inH2O RANGE AND +/-1.5% FS ACCURACY
UNITS INCLUDE: bar, oz/in 2 , psi, mbar, kPa, inHg, mmHg, kg/cm 2 , inH2O,
ftH20, and cmH2O
MAGNET ON BACK FOR HANDS-FREE OPERATION
**
**GENERAL SPECIFICATIONS
Klein Tools ET180 is designed to measure the pressure for ports P1, P2, and the differential pressure individually for air and gas pressures. The meter features a magnet in back for hands-free operation.
- Environment: Indoors
- Sensor Type: Gauge manometer/dual sensors with temperature compensation
- Range: +/- 60 inH2O
- Accuracy: +/- 1.5% FS at 25°C
- Measurement units: bar, oz/in 2 , psi, mbar, kPa, inHg, mmHg, kg/cm 2 , inH2O, ftH20, and cmH2O
- Auto Power Off (APO): After 15 minutes of inactivity
- Tubing: 1/8″ ID × 6.56′ (3mm ID × 2m) silicon tubing included
- Batteries: 3× AAA alkaline
- Operating Altitude: 6562 ft. (2000 m)
- Relative Humidity: <85% non-condensing
- Operating Temp: 32° to 122°F (0° to 50°C)
- Storage Temp: 14° to 140°F (-10° to 60°C)
- Dimensions: 6.19″ × 2.47″ × 1.38″ (157 × 63 × 35 mm)
- Weight: 7.2 oz. (202 g) including batteries
- Standards: Conforms to EN 61326-1:2013; EN61326-2-3:2013
Specifications are subject to change.
WARNINGS
To ensure safe operation and service of the tester, follow these instructions.
Failure to observe these warnings can result in severe injury or death. Know
the characteristics of the gas you are working with and use proper precautions
to avoid hazardous conditions.
• Read, understand and follow all instructions to ensure safe operation.
• The meter is NOT insulated. Avoid contact with areas where energized
inductive elements may be present. Shut off power to the area before starting
measurements.
• Always wear approved eye protection.
SYMBOLS ON METER
FEATURE DETAILS
1. LCD Screen
A. Measurement
B. P1, P2, DIFF indicator
C. Units of Measure
D. Low battery indicator
E. Hold, Max, Min, and Avg icons
F. Auto Power Off (APO) icon
G. Zero icon
2. P1/P2 ports
3. P1/P2 button| 4. UNITS button
5. Power button
6. HOLD button
7. MAX/MIN button
8. Backlight button
9. ZERO button
10. Magnetic holder
11. Battery door
12. Battery door screw
---|---
FUNCTION BUTTONS
POWER BUTTON 5
Press and hold for two seconds to turn the meter on/off.
NOTE : To conserve battery life, the meter will automatically power off
after 15 minutes of inactivity.
Auto-Power Off (APO) Function While the unit is powered on, press and hold the
Zero button 9 for two seconds to turn on/off the APO function. NOTE: APO on is
the default setting.
P1/P2 BUTTON 3
Repeated presses will toggle between P1, P2, and differential (P1-P2)
measurements. NOTE: P1 is the meter default.
UNITS BUTTON 4
Repeated presses will toggle between bar, oz/in 2 , psi, mbar, kPa, inHg,
mmHg,kg/cm 2, inH2O, ftH20, and cmH2O options.
HOLD BUTTON 6
Press to lock the current reading on the display. Reading will remain on the
display until pressed again, or until the meter automatically powers off.
MAX/MIN BUTTON 7
Press to toggle between the Maximum, Minimum, and Average values. Press and
hold for two seconds to exit the selected mode.
BACKLIGHT BUTTON 8
Press to power backlight on/off.
ZERO BUTTON 9
Press to automatically zero the meter before starting measurements.
OPERATING INSTRUCTIONS
-
Press the Power button 5 for 2 seconds to power on the meter.
NOTE : The Auto-power off will automatically turn off the meter after 15 minutes of non-user activity to conserve battery life. -
Press the Zero button 9 before taking pressure readings, it will zero both P1 and P2 ports.
-
Connect a single hose to measure pressure relative to ambient pressure or attach both hoses for differential pressure (P1-P2).
-
Press the P1/P2 button 3 to toggle between the P1, P2, or Differential Pressure measurements on the display.
-
Press the Unit button 4 to change to the desired unit.
NOTE: “OL” is displayed on the LCD if the pressure is outside the
measurement range.
NOTE : “ERR” is displayed on the LCD if the sensor has been damaged. The
unit will no longer operate to measure pressure.
NO USER-SERVICEABLE PARTS INSIDE THE METER. DO NOT ATTEMPT TO
REPAIR. Discontinue use and contact Klein Tools Customer Service.
NOTE : To ensure the highest accuracy it is recommended to use the meter
at ambient temperature.
OPERATING INSTRUCTIONS
PRESSURE MEASUREMENT ACCURACY
UNIT OF MEASURE| ABBREVIATION ON LCD| RANGE|
RESOLUTION| ACCURACY
Bar| bar| ±0.150| 0.001| +/-1.5%
Full Scale
Ounces per square inch| ozin2| ±34.80| 0.01
Pounds per square inch| psi| ±2.175| 0.001
Millibar| mbar| ±150.0| 0.1
Kilopascal| hPa| ±15.00| 0.01
Inch of mercury| inHg| ±4.429| 0.001
Millimeter of mercury| mmHg| ±112.5| 0.1
Kilogram per square centimeter| kgcm2| ±0.152| **
0.001
Inch of water| inH20| ±60.32| 0.01
Foot of water| ftH20| ±5.026| 0.001
Centimeter of Water**| cmH20| ±152.9| 0.1
BATTERY REPLACEMENT
When the Low Battery Indicator D is blinking, the batteries must be replaced.
1. Loosen screw 12 and remove battery door 11.
2. Remove and recycle 3 spent AAA batteries.
3. Install 3 new AAA batteries, noting proper polarity.
4. Replace the battery door and tighten the screw securely.
CLEANING
Be sure the tester is turned off and wiped with a clean, dry lint-free cloth.
Do not use abrasive cleaners or solvents.
STORAGE
Remove the batteries when the tester is not in use for a prolonged period of
time. Do not expose to high temperatures or humidity. After a period of
storage in extreme conditions exceeding the limits mentioned in the General
Specifications section, allow the tester to return to normal operating
conditions before using.
WARRANTY